• Title/Summary/Keyword: Ge(001)

Search Result 116, Processing Time 0.02 seconds

The influence of internal ring beams on the internal pressure for large cooling towers with wind-thermal coupling effect

  • Ke, Shitang;Yu, Wei;Ge, Yaojun;Zhao, in;Cao, Shuyang
    • Wind and Structures
    • /
    • v.28 no.1
    • /
    • pp.1-17
    • /
    • 2019
  • Internal ring beams are primary components of new ring-stiffened cooling towers. In this study, numerical simulation of the internal flow field of a cooling tower with three ring beams under wind-thermal coupling effect is performed. The studied cooling tower is a 220-m super-large hyperbolic indirect natural draft cooling tower that is under construction in China and will be the World's highest cooling tower, the influence of peripheral radiators in operating cooling tower is also considered. Based on the simulation, the three-dimensional effect and distribution pattern of the wind loads on inner surface of the cooling tower is summarized, the average wind pressure distributions on the inner surface before and after the addition of the ring beams are analyzed, and the influence pattern of ring beams on the internal pressure coefficient value is derived. The action mechanisms behind the air flows inside the tower are compared. In addition, the effects of internal ring beams on temperature field characteristics, turbulence kinetic energy distribution, and wind resistance are analyzed. Finally, the internal pressure coefficients are suggested for ring-stiffened cooling towers under wind-thermal coupling effect. The study shows that the influence of internal stiffening ring beams on the internal pressure and flow of cooling towers should not be ignored, and the wind-thermal coupling effect should also be considered in the numerical simulation of cooling tower flow fields. The primary conclusions presented in this paper offer references for determining the internal suction of such ring-stiffened cooling towers.

Development of Biopsy Assist Device on Computed Tomography Using 3D Printing Technology (3D 프린팅 기술을 이용한 전산화단층영상 기반 조직 생검 보조기구 개발)

  • Jeong-Wan Kim;Youl-Hun Seoung
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.151-157
    • /
    • 2023
  • The purpose of this study was to develop an assist device that could correct and support patient position during biopsy on computed tomography (CT) using 3D printing technology. The development method was conducted in the order of 3D design, 3D output, intermediate evaluation for product, final assist device evaluation. The 3D design method was conducted in the order of prior research data survey, measurement, primary modeling, 3D printing, output evaluation, and supplementary modeling. The 3D output was the 3D printer (3DWOX 2X, Sindoh, Korea) with additive manufacturing technology and the polylactic acid (PLA) materials. At this time, the optimal strength was evaluated to infill degree of product as the 3D printing factors into 20%, 40%, 60%, and 80%. The intermediate evaluation and supplementation was measured noise in the region of interest (ROI) around the beam hardening artifact on the CT images. We used 128-channel MDCT (Discovery 75 HD, GE, USA) to scan with a slice thickness of 100 kVp, 150 mA, and 2.5 mm on the 3D printing product. We compared the surrounding noise of the final 3D printing product with the beginning of it. and then the strength of it according to the degree of infill was evaluated. As a result, the surrounding noise of the final and the early devices were measured at an average of 3.3 ± 0.5 HU and 7.1 ± 0.1 HU, respectively, which significantly reduced the noise of the final 3D printing product (p<0.001). We found that the percentage of infill according to the optimal strength was found to be 60%. Finally, development of assist devices for CT biopsy will be able to minimize artifacts and provide convenience to medical staff and patients.

Segmental Liver Stiffness Evaluated with Magnetic Resonance Elastography Is Responsive to Endovascular Intervention in Patients with Budd-Chiari Syndrome

  • Peng Xu;Lulu Lyu;HaitaoGe;Muhammad Umair Sami;Panpan Liu;Chunfeng Hu;Kai Xu
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.773-780
    • /
    • 2019
  • Objective: To assess segmental liver stiffness (LS) with MRI before and after endovascular intervention in patients with Budd-Chiari syndrome (BCS). Materials and Methods: Twenty-three patients (13 males and 10 females; mean age, 42.6 ± 12.6 years; age range, 31-56 years) with BCS as a primary liver disease were recruited for this study. Two consecutive magnetic resonance elastography (MRE) examinations were performed before the endovascular treatment. Fifteen patients who underwent endovascular intervention treatment also had follow-up MRE scans within three days after the procedure. LS was measured in three liver segments: the right posterior, right anterior, and left medial segments. Inter-reader and inter-exam repeatability were analyzed with intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Segmental LS and clinical characteristics before and after the intervention were also compared. Results: Within three days of the endovascular intervention, all three segmental LS values decreased: LS of the right posterior segment = 7.23 ± 0.88 kPa (before) vs. 4.94 ± 0.84 kPa (after), LS of the right anterior segment = 7.30 ± 1.06 kPa (before) vs. 4.77 ± 0.85 kPa (after), and LS of the left medial segment = 7.22 ± 0.87 kPa (before) vs. 4.87 ± 0.72 kPa (after) (all p = 0.001). There was a significant correlation between LS changes and venous pressure gradient changes before and after treatments (r = 0.651, p = 0.009). The clinical manifestations of all 15 patients significantly improved after therapy. The MRE repeatability was excellent, with insignificant variations (inter-reader, ICC = 0.839-0.943: inter-examination, ICC = 0.765-0.869). Bland-Altman analysis confirmed excellent agreement (limits of agreement, 13.4-19.4%). Conclusion: Segmental LS measured by MRE is a promising repeatable quantitative biomarker for monitoring the treatment response to minimally invasive endovascular intervention in patients with BCS.

Comparison of the Quantitative Values of C-14 and C-13 UBT to Reflect the Presence and Degree of Ongoing Helicobacter pylori Infection (Helicobacter pylori 감염 유무와 정도 반영에 대한 C-14와 C-13 요소호기검사 정량치 비교)

  • Lim, Seok-Tae;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.229-234
    • /
    • 2008
  • Purpose: A urea breath test (UBT) using C-14 or C-13 has been developed for identifying Helicobacter (H) pylori infection on the basis of urease production with release of labeled $CO_2$. We investigated if the C-14 and C-13 UBT have the difference to reflect the presence and degree of H. pylori infection detected by gastro-duodenoscopic biopsies (CBx) in the same patients. Materials and methods: Thirty eight patients (M:F = 28:10, age $53.4{\pm}13.0$ yrs) with upper gastrointestinal symptoms such as indigestion, gastric fullness or pain consecutively underwent C-14 UBT, GBx and C-13 UBT within one week before medications. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (37 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive (${\ge}$ 200 dpm), intermediate (50-199 dpm) or negative (50 dpm). For the C-13 UBT, the results were classified as positive (${\ge}2.5\%_{\circ}$) or negative ($<2.5\%_{\circ}$). The results of GBx with Giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT and C-13 UBT results with GBx grade as a gold standard. Results: The prevalence of H. pylori infection by GBx with Giemsa stain was 25/38 (65.8%). In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.0%, 92.3%, 95.8%, 91.7% and 92.1%, respectively. However, the C-13 UBT had sensitivity, specificity, PPV, NPV and accuracy of 96.0%, 84.6%, 92.3%, 91.7% and 92.1%, respectively. The more significant correlation in C-14 than C-13 UBT (r=0.948 vs r=0.819, p <0.001) was found between the value of UBT and the grade of distribution of H. pylori infection. Conclusion: We conclude that the diagnostic performance between C-14 and C-13 UBT to detect H. pylori infection is not significantly different, but the value of C-14 UBT more significantly reflects the degree of bacterial distribution.

Evaluation of Xerostomia Following 3 Dimensional Conformal Radiotherapy for Nasopharyngeal Cancer Patients (3차원 입체조형 방사선치료를 시행받은 코인두암 환자에서의 구강건조증 분석)

  • Park Young-Je;Park Won;Ju Sang-Gyu;Nam Hee-Rim;Oh Dong-Ryul;Park Hee-Chul;Ahn Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.24 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purose: This study is to evaluate the xerostomia following 3-dimensional conformal radiation therapy (3D CRT) in nasopharynx cancer patients using the xerostomia questionnaire score (XQS). Materials and Methods: Questionnaire study was done on 51 patients with nasopharynx cancer who received 3D CRT from Dec. 2000 to Aug. 2005. 3D CRT technique is based on 'serial shrinking field' concept by 3 times of computed tomography (CT) simulation. Total target dose to the primary tumor was 72 Gy with 1.8 Gy daily fractions. Xerostomia was assessed with 4-questions XQS, and the associations between XQS and time elapsed after RT, age, sex, stage, concurrent chemotherapy, and parotid dose were analyzed. Results: Concurrent chemotherapy was given to 40 patients and RT alone was given to 11 patients. The median time elapsed after 3D CRT was 20 ($1{\sim}58$) months and the mean XQS of all 51 patients was $8.4{\pm}1.9\;(6{\sim}14)$. XQS continuously and significantly decreased over time after 3D CRT ($X^2$=-0.484, p<0.05). There was no significant difference in XQS according to sex, age, and stag. However, XQS of concurrent chemotherapy patients was significantly higher than RT alone patients (P=0.001). XQS of patients receiving total mean parotid dose ${\ge}35 Gy$ was significantly higher than <35 Gy (p=0.05). Decreasing tendency of XQS over time after 3D CRT was observed. Concurrent chemotherapy and total mean parotid dose ${\ge}35 Gy$ were suggested to adversely affect radiation-induced xerostomia.

Effects of L-Carnitine with Different Lysine Levels on Growth and Nutrient Digestibility in Pigs Weaned at 21 Days of Age

  • Cho, W.T.;Kim, J.H.;Han, In K.;Han, Y.K.;Heo, K.N.;Odle, J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.5
    • /
    • pp.799-805
    • /
    • 1999
  • This study was conducted to investigate the effects of L-carnitine with different levels of lysine on performance of pigs weaned at 21 days of age. A total of 120 pigs were allotted into a $3{\times}2$ factorial design with three different levels of lysine (1.40%, 1,60% and 1.80%) and two levels of L-carnitine (0 and 1,000 ppm). Each treatment had 4 replications with 5 pigs per replicate. Pigs of $22{\pm}1$ days (5.9 kg of body weight) were grouped into a completely randomized block design. Treatments were 1) 1.4-Crt; 1.40% of lysine with 1,000 ppm of L-carnitine, 2) 1.4-N; 1.40% of lysine without L-carnitine, 3) 1.6-Crt; 1.60% of lysine with 1,000 ppm of L-carnitine, 4) 1.6-N; 1.60% of lysine without L-carnitine, 5) 1.8-Crt; 1.80% of lysine with 1,000 ppm of L-carnitine and 6) 1.8-N; 1.80% of lysine without L-carnitine. Growth performance was optimized in pigs fed 1.6% lysine regardless of carnitine addition. For the first 7 days of the experimental period, the best ADG and F/G were found in pigs within the 1.6-Crt group. Carnitine significantly improved (p<0.05) ADG of pigs when the lysine level in the diet was 1.6%. Only in the third week carnitine had a significant influence on growth performance of pigs. A lysine-sparing effect of L-carnitine was not detected in this study. The 1.6-Crt group showed the best proximate nutrient digestibility, and the crude fat and gross energy digestibility were higher when the L-carnitine was added in the diet. Lysine level significantly affected the digestibilities of DM (p<0.001), GE (p<0.001), CP (p<0.01) and C.fat (p<0.05). Carnitine also significantly improved digestibility of nutrients. Lysine level as well as carnitine level affected the amino acids digestibility, however, in 1.8% lysine diet carnitine did not influence on amino acids digestibility. Plasma carnitine content was significant higher (p<0.05) in pigs fed L-carnitine. This indicates the increased biological availability of carnitine within the body. L-carnitine supplementation tended to improve feed utilization during the third week (p<0.10) and during the entire period (p=0.10). Lysine level significantly affected feed utilization of pigs during the third week and entire period (p<0.05). As pigs grew, the lysine requirement was reduced.

Retinoid Receptors in Gastric Cancer: Expression and Influence on Prognosis

  • Hu, Kong-Wang;Chen, Fei-Hu;Ge, Jin-Fang;Cao, Li-Yu;Li, Hao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.1809-1817
    • /
    • 2012
  • Background: Gastric cancer is frequently lethal despite aggressive multimodal therapies, and new treatment approaches are therefore needed. Retinoids are potential candidate drugs: they prevent cell differentiation, proliferation and malignant transformation in gastric cancer cell lines. They interact with nuclear retinoid receptors (the retinoic acid receptors [RARs] and retinoid X receptors [RXRs]), which function as transcription factors, each with three subclasses, ${\alpha}$, ${\beta}$ and ${\gamma}$. At present, little is known about retinoid expression and influence on prognosis in gastric cancers. Patients and Methods: We retrospectively analyzed the expression of the subtypes RARa, $RAR{\beta}$, $RAR{\gamma}$, RXRa, $RXR{\beta}$, $RXR{\gamma}$ by immunohistochemistry in 147 gastric cancers and 51 normal gastric epithelium tissues for whom clinical follow-up data were available and correlated the results with clinical characteristics. In addition, we quantified the expression of retinoid receptor mRNA using real-time PCR (RT-PCR) in another 6 gastric adenocarcinoma and 3 normal gastric tissues. From 2008 to 2010, 80 patients with gastric cancers were enrolled onto therapy with all-trans-retinoic acid (ATRA). Results: RARa, $RAR{\beta}$, $RAR{\gamma}$ and $RXR{\gamma}$ positively correlated with each other (p < 0.001) and demonstrated significantly lower levels in the carcinoma tissue sections (p < 0.01), with lower $RAR{\beta}$, $RAR{\gamma}$ and RXRa expression significantly related to advanced stages (p < =0.01). Tumors with poor histopathologic grade had lower levels of RARa and $RAR{\beta}$ in different histological types of gastric carcinoma (p < 0.01). Patients whose tumors exhibited low levels of RARa expression had significantly lower overall survival compared with patients who had higher expression levels of this receptor (p < 0.001, HR=0.42, 95.0% CI 0.24-0.73), and patients undergoing ATRA treatment had significantly longer median survival times (p = 0.007, HR=0.41, 95.0% CI 0.21-0.80). Conclusions: Retinoic acid receptors are frequently expressed in epithelial gastric cancer with a decreased tendency of expression and RARa may be an indicator of a positive prognosis. This study provides a molecular basis for the therapeutic use of retinoids against gastric cancer.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Clinical and Polysomnographic Characteristics of REM Sleep-Dependent Obstructive Sleep Apnea (REM 수면 의존성 폐쇄성 수면무호흡증 환자의 임상적 특성과 수면 변인에 관한 연구)

  • Lee, Yu-Jin;Lee, Soon-Jeong;Kang, Dong-Jin
    • Sleep Medicine and Psychophysiology
    • /
    • v.15 no.2
    • /
    • pp.77-81
    • /
    • 2008
  • Introduction: REM sleep which shows characteristic muscle atonia and increased resistance of upper respiratory track is known to be vulnerable to sleep apnea. Previous studies reported that REM sleep-dependent (or related) obstructive sleep apnea syndrome (REM-dependent OSA) could be one of sleep disordered breathing. The present study aimed to investigate clinical findings and polysomnographic variables of REM-dependent OSA. Methods: Fifty-six patients diagnosed with mild to moderate obstructive sleep apnea by overnight polysomnography (5$53.7{\pm}16.7$ years, 42 males). REM-dependent OSA was defined as AHI-REM/AHI-NREM ratio>2. We compared clinical and polysomnographic findings between REM-dependent OSA and No REM-dependent OSA patients. Results: Among 56 patients, 37.5% (n=21, average age of $52.3{\pm}19.7$ years, 14 males) met the REM-dependent OSA criteria. There were no significant differences in age, sex and body mass index between two groups. After controlling for age, sex, body mass index and periodic leg movements index, REM-dependent OSA patients showed significantly lower AHI, lower number of oxygen desaturation events and higher stage 2 sleep proportion compared to No REM-dependent OSA patients (p=0.010, p=0.006, p=0.031, respectively). After controlling for age, sex, body mass index and periodic legs movements index, AHI-REM was positively correlated with the number of oxygen desaturation events in REM-dependent OSA group (p=0.002). Conclusion: Current results suggested that 37.5% of patients with mild to moderate severity of obstructive sleep apnea could be classified into REM-dependent OSA. REM-dependent OSA was more common in mild severity of OSA, equally prevalent in both sexes and accompanied with sleep architecture changes, i.e. increased proportion of stage 2. In addition, apneic events during REM sleep in REM-dependent OSA were related to oxygen desaturation.

  • PDF

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF