• 제목/요약/키워드: Gauss-Seidel method

검색결과 77건 처리시간 0.032초

Jacobian 행렬의 비 대각 요소를 보존시킬 수 있는 조류계산에 관한 연구 (A Study on the load Flow Calculation for preserving off Diagonal Element in Jacobian Matrix)

  • 이종기;최병곤;박정도;류헌수;문영현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권9호
    • /
    • pp.1081-1087
    • /
    • 1999
  • Load Flow calulation methods can usually be divided into Gauss-Seidel method, Newton-Raphson method and decoupled method. Load flow calculation is a basic on-line or off-line process for power system planning. operation, control and state analysis. These days Newton-Raphson method is mainly used since it shows remarkable convergence characteristics. It, however, needs considerable calculation time in construction and calculation of inverse Jacobian matrix. In addition to that, Newton-Raphson method tends to fail to converge when system loading is heavy and system has a large R/X ratio. In this paper, matrix equation is used to make algebraic expression and then to slove load flow equation and to modify above defects. And it preserve P-Q bus part of Jacobian matrix to shorten computing time. Application of mentioned algorithm to 14 bus, 39 bus, 118 bus systems led to identical results and the same numbers of iteration obtained by Newton-Raphson method. The effect of computing time reduction showed about 28% , 30% , at each case of 39 bus, 118 bus system.

  • PDF

Jacobian 행렬의 비 대각 요소를 보존시킬 수 있는 조류계산에 관한 연구 (A Study on a Load Flow calculation for Preserved Jacobian Matrix's elements except diagonal terms)

  • 문영현;이종기;최병곤;박정도;류헌수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.311-315
    • /
    • 1998
  • Load Flow calculation methods can usually be divided into Gauss-Seidel method, Newton-Raphson method and decoupled method. Load flow calculation is a basic on-line or off-line process for power system planning, operation, control and state analysis. These days Newton-Raphson method is mainly used since it shows remarkable convergence characteristics. It, however, needs considerable calculation time in construction and calculation of inverse Jacobian matrix. In addition to that, Newton-Raphson method tends to fail to converge when system loading is heavy and system has a large R/X ratio. In this paper, matrix equation is used to make algebraic expression and then to solve load flow equation and to modify above defects. And it preserve certain part of Jacobian matrix to shorten the time of calculation. Application of mentioned algorithm to 14 bus, 39 bus, 118 bus systems led to identical result and the number of iteration got by Newton-Raphson method. The effect of time reduction showed about 28%, 30%, at each case of 39 bus, 118 bus system.

  • PDF

풍력발전단지 관리·분석 시스템의 Real-Time Simulator 도입을 위한 계통모델 연동방안 연구 (A Study About Grid Impose Method On Real-Time Simulator For Wind-Farm Management System)

  • 정승민;유연태;김현욱;장길수
    • 조명전기설비학회논문지
    • /
    • 제29권7호
    • /
    • pp.28-37
    • /
    • 2015
  • Owing to the variability of large-scaled wind power system, the development of wind farm management technologies and related compensation methods have been receiving attention. To provide an accurate and reliable output power, certain wind farm adopts a specified management system including a wind prediction model and grid expectation solutions for considering grid condition. Those technologies are focused on improving the reliability and stability issues of wind farms, which can affect not only nearby system devices but also a voltage condition of utility grid. Therefore, to adapt the develop management system, an expectation process about voltage condition of Point of Common Coupling should be integrated in operating system for responding system requirements in real-time basis. This paper introduce a grid imposing method for a real-time based wind farm management system. The expected power can be transferred to the power flow section and the required quantity about reactive power can be calculated through the proposed system. For the verification process, the gauss-seidel method is introduced in the Matlab/Simulink for analysing power flow condition. The entire simulation process was designed to interwork with PSCAD for verifying real power system condition.

통계적 패킷 음성 / 데이터 다중화기의 성능 해석 (Performance Analysis of a Statistical Packet Voice/Data Multiplexer)

  • 신병철;은종관
    • 한국통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.179-196
    • /
    • 1986
  • 본 논문에서는 통계적 패킷 음성/데이터 다중화기의 성능을 연구하였다. 성능해석은 음성과 데이터가 서로 분리된 한정된 queue를 사용하고, 전송에 있어서 음성이 데이터보다 우선권을 갖는 것을 가정하고, 다중화기의 출력 link를 시간 slot단위로 나누고 음성은 (M+1)-state의 Markov Process로, 데이터는 Poisson process로 modeling 하여 수행하였다. 전송시 음성신호가 데이터 신호보다 우선권을 가지므로 음성의 queueing behavior는 data에 거의 영향을 받지 않는다. 다라서 본 연구에서는 음성의 queueing behavior를 먼저 해석한 다음 data의 queueing behavior를 해석하였다. 패킷 음성 다중화기의 성능 해석은 입력상태와 buffer의 점유를 2차원의 Markov chain을 가지고 formulation하였고, 집적된 음성/data의 다중화기는 data를 추가한 3차원 Markov chain으로 하였다. 이러한 model을 사용하여 Gauss-Seidel방법으로 결과를 얻고 simulation으로 입증하였다. 이들 결과로 부터 음성 가입자의 수, 출력 link용량, 음성의 queue크기, 음성의 overflow확률에서는 서로 trade-off가 있고 data에서도 비슷한 tradeoff가 있음을 알았다. 또한 입력 traffic량과 link의 용량에 따라서 음성과 데이타간의 성능에서 서로 tradeoff가 있고, TASI의 이득이 2이상이고 음성가입자의 수가 적을 경우 데이타의 평균 지연시간은 buffer의 최대길이 보다 길음을 알아내었다.

  • PDF

A New Fair Call Admission Control for Integrated Voice and Data Traffic in Wireless Mobile Networks

  • Hwang, Young Ha;Noh, Sung-Kee;Kim, Sang-Ha
    • Journal of Information Processing Systems
    • /
    • 제2권2호
    • /
    • pp.107-113
    • /
    • 2006
  • It is essential to guarantee a handoff dropping probability below a predetermined threshold for wireless mobile networks. Previous studies have proposed admission control policies for integrated voice/data traffic in wireless mobile networks. However, since QoS has been considered only in terms of CDP (Call Dropping Probability), the result has been a serious CBP (Call Blocking Probability) unfairness problem between voice and data traffic. In this paper, we suggest a new admission control policy that treats integrated voice and data traffic fairly while maintaining the CDP constraint. For underprivileged data traffic, which requires more bandwidth units than voice traffic, the packet is placed in a queue when there are no available resources in the base station, instead of being immediately rejected. Furthermore, we have adapted the biased coin method concept to adjust unfairness in terms of CBP. We analyzed the system model of a cell using both a two-dimensional continuous-time Markov chain and the Gauss-Seidel method. Numerical results demonstrate that our CAC (Call Admission Control) scheme successfully achieves CBP fairness for voice and data traffic.

Determination of Optimal Cell Capacity for Initial Cell Planning in Wireless Cellular Networks

  • Hwang, Young-Ha;Noh, Sung-Kee;Kim, Sang-Ha
    • Journal of Information Processing Systems
    • /
    • 제2권2호
    • /
    • pp.88-94
    • /
    • 2006
  • In wireless cellular networks, previous researches on admission control policies and resource allocation algorithm considered the QoS (Quality of Service) in terms of CDP (Call Dropping Probability) and CBP (Call Blocking Probability). However, since the QoS was considered only within a predetermined cell capacity, the results indicated a serious overload problem of systems not guaranteeing both CDP and CBP constraints, especially in the hotspot cell. That is why a close interrelationship between CDP, CBP and cell capacity exists. Thus, it is indispensable to consider optimal cell capacity guaranteeing multiple QoS (CDP and CBP) at the time of initial cell planning for networks deployment. In this paper, we will suggest a distributed determination scheme of optimal cell capacity guaranteeing both CDP and CBP from a long-term perspective for initial cell planning. The cell-provisioning scheme is performed by using both the two-dimensional continuous-time Markov chain and an iterative method called the Gauss-Seidel method. Finally, numerical and simulation results will demonstrate that our scheme successfully determines an optimal cell capacity guaranteeing both CDP and CBP constraints for initial cell planning.

비정렬 격자계에서 균질혼합 모델을 이용한 2차원 수중익형 주위의 캐비테이션 유동 해석 (CAVITATION FLOW SIMULATION FOR A 2-D HYDROFOIL USING A HOMOGENEOUS MIXTURE MODEL ON UNSTRUCTURED MESHES)

  • 안상준;권오준
    • 한국전산유체공학회지
    • /
    • 제17권1호
    • /
    • pp.94-100
    • /
    • 2012
  • In this paper, the cavitating flows around a hydrofoil have been numerically investigated by using a 2-d multi-phase RANS flow solver based on pseudo-compressibility and a homogeneous mixture model on unstructured meshes. For this purpose, a vertex-centered finite-volume method was utilized in conjunction with 2nd-order Roe's FDS to discretize the inviscid fluxes. The viscous fluxes were computed based on central differencing. The Spalart-Allmaras one equation model was employed for the closure of turbulence. A dual-time stepping method and the Gauss-Seidel iteration were used for unsteady time integration. The phase change rate between the liquid and vapor phases was determined by Merkle's cavitation model based on the difference between local and vapor pressure. Steady state calculations were made for the modified NACA66 hydrofoil at several flow conditions. Good agreements were obtained between the present results and the experiment for the pressure coefficient on a hydrofoil surface. Additional calculation was made for cloud cavitation around the hydrofoil. The observation of the vapor structure, such as cavity size and shape, was made, and the flow characteristics around the cavity were analyzed. Good agreements were obtained between the present results and the experiment for the frequency and the Strouhal number of cavity oscillation.

핵 융합로 제1벽의 냉각성능에 관한 수치해석적 연구 (Numerical analysis of the cooling effects for the first wall of fusion reactor)

  • 정인수;황영규
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.18-30
    • /
    • 1999
  • A heat transfer analysis for the two-dimensional (2-D) steady state using finite difference method (FDM) is performed to predict the thermal behavior of the primary first-wall (FW) system of fusion reactor under various geometric and thermo-hydraulic conditions, such as the beryllium (Be) armor thickness, pitch of cooling tube, and coolant velocity. The FW consists of authentic steel (type 316 stainless steel solution annealed) for cooling tubes, Cu for cooling tubes embedding material, and Be for a protective armor, based on the International Thermonuclear Experiment Reactor (ITER) report. The present 2-D analysis, the control volume discretized with hybrid grid (rectangular grid and polar grid) and Gauss-Seidel iteration method are adapted to solve the governing equations. In the present study, geometric and thermo-hydraulic parameters are optimized with consideration of several limitations. Consequently, it is suggested that the adequate pitch of cooling tube is 22-32mm, the beryllium armor thickness is 10-12mm, and that the coolant velocity is 4.5m/s-6m/s for $100^{\circ}C$ of inlet coolant temperature. The cooling tube should locate near beryllium armor. But, it would be better for locating the center of Cu wall, considering problems of material and manufacturing. Also, 2-D analysis neglecting the axial temperature distribution of cooling tube is appropriate, regarding the discretization error in axial direction.

  • PDF

배전계통에 적용된 조류계산 알고리즘 적용사례 및 미래형 연구 (Current Case & Future Study applied on Distribution System Load Flow Algorithm)

  • 이상성;송광재;손진만;한중교;이태용;박종근;문승일;김재철;이송근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.181-183
    • /
    • 2003
  • 본 연구에서는 현재 국내-외 논문을 참조하여 배전계통에 적용된 조류계산 알고리즘의 적용사례를 조사하였다. 배전계통에 적용된 조류계산알고리즘은 Power Summation Method와 Current Summation Method가 있다. 배전계통은 선로의 구조가 거의 대부분 방사상으로 성되어 있기 때문에 Newton Raphson, Gauss Seidel, Fast Decoupled 방법을 그대로 사용하기는 문제가 있다. 그래서 DistFlow, Forward/Backward sweeping 법 등이 주로 사용되어 왔다. 그러나 미래의 계통은 현재와는 또 다른 Topology로 방사상과 루프가 혼합된 형태로 다르게 구성되어야 할 것이다. 이러한 상황에서 미래의 배전계통에 대하여 적용 가능한 알고리즘을 전망하고져 한다.

  • PDF

TAPINS: A THERMAL-HYDRAULIC SYSTEM CODE FOR TRANSIENT ANALYSIS OF A FULLY-PASSIVE INTEGRAL PWR

  • Lee, Yeon-Gun;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • 제45권4호
    • /
    • pp.439-458
    • /
    • 2013
  • REX-10 is a fully-passive small modular reactor in which the coolant flow is driven by natural circulation, the RCS is pressurized by a steam-gas pressurizer, and the decay heat is removed by the PRHRS. To confirm design decisions and analyze the transient responses of an integral PWR such as REX-10, a thermal-hydraulic system code named TAPINS (Thermal-hydraulic Analysis Program for INtegral reactor System) is developed in this study. Based on a one-dimensional four-equation drift-flux model, TAPINS incorporates mathematical models for the core, the helical-coil steam generator, and the steam-gas pressurizer. The system of difference equations derived from the semi-implicit finite-difference scheme is numerically solved by the Newton Block Gauss Seidel (NBGS) method. TAPINS is characterized by applicability to transients with non-equilibrium effects, better prediction of the transient behavior of a pressurizer containing non-condensable gas, and code assessment by using the experimental data from the autonomous integral effect tests in the RTF (REX-10 Test Facility). Details on the hydrodynamic models as well as a part of validation results that reveal the features of TAPINS are presented in this paper.