• 제목/요약/키워드: Gaseous

검색결과 1,368건 처리시간 0.032초

Quantification of Total Mercury in Antarctic Surface Snow using ICP-SF-MS: Spatial Variation from the Coast to Dome Fuji

  • Han, Yeong-Cheol;Huh, Young-Sook;Hong, Sung-Min;Hur, Soon-Do;Motoyama, Hideaki;Fujita, Shuji;Nakazawa, Fumio;Fukui, Kotaro
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권12호
    • /
    • pp.4258-4264
    • /
    • 2011
  • The total mercury concentration ($Hg_T$) of surface snow samples collected along a ~1500 km transect in east Queen Maud Land was determined using inductively coupled plasma sector field mass spectrometry to address the behavior of Hg on the Antarctic Plateau. Due to the volatile nature of mercury, measures were taken against Hg loss from standard solutions by choosing appropriate container material and stabilizing agents. Glass bottles with Teflon-lined caps were superior to Teflon and polyethylene containers in protecting against Hg loss, but addition of gold chloride ($AuCl_3$) or bromine chloride (BrCl) was necessary to ensure preservation of Hg. As Hg loss was also observed in snowmelt samples, our analysis may underestimate the actual amount of HgT in the snow. Even so, the measured HgT was still very low (< 0.4-10.8 pg $g^{-1}$, n = 44) without a signal of depositional enhancement accompanying photo-oxidation of atmospheric elemental mercury in austral midsummer. Moreover, the dynamic variation along the traverse implies spatial and temporal heterogeneity in its source processes.

토양내 총 NAPL과 공기접촉 NAPL의 측정을 위한 분별 NAPL 분배 추적자 기술의 개발

  • 최경민;김헌기
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.29-32
    • /
    • 2004
  • Gaseous partitioning tracer test has been used for determining the volume and spatial distribution of residual non-aqueous phase liquid (NAPL) in the unsaturated soils. In this study, an experimental method for measuring the content of gas-exposed NAPL as well as that of total NAPL in a sand during air sparging was developed. Two different gaseous phase NAPL-partitioning tracers were used; n-pentane, with very low water solubility, was used as the tracer that partitions into NAPL that is only in contact with the mobile gas, and chloroform, with fairly good water solubility, was selected for detecting total NAPL content in the sand. Helium and difluromethanewere used as the non- reactive tracer and water-partitioning tracers, respectively. Using n-decane as a model NAPL (NAPL saturation of 0.018), 25.6% of total NAPL was detected by n-pentane at the water saturation of 0.68. Oniy 9.1% of total NAPL was detected by n-pentane at the water saturation of 0.84. This result implies that the quantity of gas-exposed NAPL increased about three times when the water saturation decreased from 0.84 to 0.68. At the water saturation of 0.68, more than 90% of total NAPL was detected by chloroform while 65.8% of total NAPL was detected by chloroform at the water saturation of 0.84. Considering that the removal rate of NAPL during air sparging for NAPL-contaminated aquifer is expected to be greatly dependent upon the spatial arrangement of NAPL phase with respect to the mobile gas, this new approach may provide useful information for investigating the mass transfer process during air-driven remedial processes fer NAPL-contaminated subsurface environment.

  • PDF

푸른길 공원의 대기 환경 특성에 관한 연구 (Air Environmental Characteristics of a Greenway Park in Gwangju)

  • 민경우;이경석;박옥현;윤관주;김도술;박세일;정원삼;이대행;조영관
    • 한국환경보건학회지
    • /
    • 제41권3호
    • /
    • pp.171-181
    • /
    • 2015
  • Objectives: This study aimed to survey the characteristics of air quality and meteorological conditions in a greenway park. Methods: We measured meteorological and health related factors, including noise, particulate matter ($PM_{10}$) and selected gaseous air pollutants at three locations in a greenway park and on a general roadside as comparison. The measurements were repeated four times from April to October 2014. Results: The average air temperature in the greenway park was $20.7^{\circ}C$ which was $1-2^{\circ}C$ lower than on the general roadside. The average $PM_{10}$ concentration in the greenway park was $85.0{\mu}g/m^3$, a level 2-3 times lower than that at the roadside. The noise level at the greenway site was 4.4 dB(A)- 23.0 dB(A) lower than at the roadside. The average CO, $CO_2$, $SO_2$ and NOx concentrations in the greenway park were lower than at the roadside. The average phytoncide and anions concentrations in the greenway park were higher than at the roadside. Conclusions: The urban forest of the greenway park may have some impact on air quality and meteorological conditions.

플라즈마 이온 방식의 공기정화기를 이용한 돈사내 공기오염물질 저감 효과 (Reduction Effect of Airborne Pollutants in Pig Building by Air Cleaner Operated with Plasma Ion)

  • 김윤신;김기연;조만수;고문석;고한종;정진원;오미석;윤백;김중호
    • 한국환경보건학회지
    • /
    • 제36권4호
    • /
    • pp.306-312
    • /
    • 2010
  • This field study was performed to evaluate the efficiency of a plasma ion-operated air cleaner in temporal reduction of airborne pollutants emitted from a pig housing facility. In the case of gaseous pollutants, the plasma ion air cleaner was not effective in reducing levels of ammonia, hydrogen sulfide, nitrogen dioxide, or sulfur dioxide (p>0.05). In the case of particulate pollutants, however, the air cleaner was effective in reducing levels of particulate matter ($PM_{2.5}$ and $PM_1$) by 79(${\pm}6.1$) and 78(${\pm}3.0$)%, respectively. Unlike the case of these fine particle fractions, the reduction of total suspended particles (TSP) and $PM_{10}$ following treatment was almost negligible. In the case of biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi were relatively low at 22(${\pm}6.6$) and 25(${\pm}8.7$)%, respectively. Taken together, these results indicate that in terms of air pollutants released from this pig housing facility, the plasma ion air cleaner was primarily effective in reducing levels of $PM_{2.5}$ and $PM_1$.

Effects of various densities and velocities on gaseous hydrocarbon fuel on near nozzle flow field under different laminar coflow diffusion flames

  • Ngorn, Thou;Jang, Sehyun;Yun, Seok Hun;Park, Seol Hyeon;Lee, Joo Hee;Chung, Suk Ho;Choi, Jae Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권2호
    • /
    • pp.102-106
    • /
    • 2016
  • An experimental study on the flow characteristics under various laminar coflow diffusion flames was conducted with a particular focus on the buoyancy force exerted from gaseous hydrocarbon fuels. Methane ($CH_4$), ethylene ($C_2H_4$), and n-butane ($C_4H_{10}$) were used as the fuels. A coflow burner and the Schlieren imaging technique were used to observe the flow field of each fuel near the nozzle exit as well as the flow characteristics in the flames. The results show that a vortex with a density heavier than air appeared in n-butane near the nozzle exit with a strong negative buoyancy on the fuel steam. As the Reynolds number increased through the control of the fuel velocity of the n-butane flame, the vortices were greater and the vortex tips were moved up from the nozzle exit. In addition, the heated nozzle affected the flow fields of the fuel steam near the nozzle exit.

수용원 모델을 사용한 대기 중 수은 오염원의 위치 추정에 대한 연구 (Source Identification of Gaseous Mercury Measured in New York State Using Hybrid Receptor Modeling)

  • 한영지
    • 한국대기환경학회지
    • /
    • 제22권2호
    • /
    • pp.179-189
    • /
    • 2006
  • Ambient gas phase mercury concentrations including elemental mercury ($Hg^0$) were measured at the Potsdam, Stockton, and Sterling sites in NY from 2000 to 2003. Also, concentrations of ambient reactive gaseous mercury (RGM; $Hg^{2+}$) were measured at the Potsdam site during one year. The contribution of RGM($4.2{\pm}6.4pg/m^3$) was about $0.2{\sim}3%$ of the total gas phase mercury concentration measured (TGM: $1.84{\pm}1.24,\;1.83{\pm}0.32,\;3.02{\pm}2.14ng/m^3$ in Potsdam. Stockton, and Sterling, respectively) at the receptor sites. Potential Source Contribution Function (PSCF), a hybrid receptor modeling incorporating backward trajectories was performed to identify source areas of TGM. Using PSCF, southern New York, North Carolina, and eastern Massachusetts were identified as important source areas in the United States, while the copper smelters and waste incinerators located in eastern Quebec and Ontario were determined to be significant sources in Canada. The Atlantic Ocean was suggested to be a possible mercury source. PSCF incorporating back-dispersion and deposition was applied for RGM , as well as PSCF based on 2-days back-trajectories. Two different approaches yielded considerably different results, primarily due to the consideration of dispersion rather than deposition. Using back-trajectory based PSCF, eastern Ohio, southern New York, and southern Pennsylvania where large coal -fired power plants area located were identified as the large sources in US. Metallurgical industry located in eastern Quebec was resolved as well. From the result of back-dispersion and deposition based PSCF, Pennsylvania, mining facilities around Lake Superior, Toronto, Boston, MA, Quebec, and coal power plants in NY were identified to be the significant source areas for Potsdam site.

GC-SCD를 이용한 가스연료 중 황화합물의 정량 (Determination of Sulfur Compounds in Gaseous Fuel by Gas Chromatography-Sulfur Chemiluminescence Detection)

  • 도이주;고재석;김호진
    • 대한화학회지
    • /
    • 제43권5호
    • /
    • pp.517-521
    • /
    • 1999
  • 가스연료 중의 부취제 농도를 기체 크로마토그래피법으로 분석하기 위해 황화합물에 대한 선택성, 직선성, 감도가 매우 우수한 황 화학광 검출기(SCD)를 이용하여 측정하였다. 그리고, 기존의 GC-SCD에 의한 황화합물 분석방법과는 달리 황화합물의 흡착으로 인한 반복성 및 재현성 문제를 해결하는 실험방법을 이용하였다. 이러한 방법에 의하여, 액화석유가스에 첨가하고 있는 황화이메틸, t-부틸메르캅탄, 황화에틸메틸에 대하여 얻은 검정 곡선은 직선성을 잘 보여주고 있다. 실제 시료 중 위의 세가지 황화합물에 대한 실험결과의 정밀성을 측정한 결과, 4일동안 각3회 반복실험하였을 때 높은 재현성을 보여주었고, 농도의 변동계수(coefficient of variation)가 3% 미만의 값을 나타내었다. 결과적으로, 본 연구에 의한 실험방법은 저유소 및 충전소의 액화석유가스 시료에 첨가된 황 함유 부취제의 농도를 신속, 정확하게 측정하는, 매우 정밀성이 높고 유용한 방법이다.

  • PDF

악취성 Carbonyl 화합물의 카트리지 채취 분석: 습도가 채취효율에 미치는 영향 (The effect of relative humidity on the performance of DNPH-cartridge sampling for odorous aldehydes)

  • 이민희;김기현
    • 분석과학
    • /
    • 제25권1호
    • /
    • pp.50-59
    • /
    • 2012
  • DNPH 카트리지 방식으로 카보닐성분들을 채취할 때, 습도변화에 따른 채취효율의 특성을 체계적으로 진단하였다. 6개의 카보닐성분(formaldehyde (FA), acetaldehyde (AA), propionaldehyde (PA), butyraldehyde (BA), isovaleraldehyde (IA), valeraldehyde (VA))을 함유한 기체상 표준시료를 DNPH카트리지로 흡수 후 용출하여 HPLC/UV 검출기로 분석하였다. 이 결과를 비슷한 수준으로 조제한 액상 혼합표준용액의 검정 결과와 비교하였다. 액상 표준시료와 대비하였을 때, 상대적으로 저분자 성분(폼알데하이드, 아세트알데하이드)에 비해 고분자 성분(프로피온알데하이드 이상)들의 회수율이 낮게 나타났다. 습도변화에 따른 기체상 표준시료의 채취효율을 0-80% 상대습도 범위에서 비교한 결과, 20~80%에서 저분자량과 고분자량 카보닐화합물들 간에 채취효율의 차이가 유지되었다. FA와 AA와 같은 저분자량 카보닐화합물의 경우, 습도의 변화에 대해 미미한 변화를 보였다. 그러나 PA 이상의 성분들은 회수율이 증가하는 경향을 보였다. 이러한 경향은 비교분석을 시도한 3개 제품에서 모두 유사한 경향을 보였으며, 고분자 카보닐화합물의 경우, 습도에 따른 회수율-변화를 적절히 보정할 필요가 있다.

건식세정기에서의 오염물 동시제거를 위한 고온3계평형 모델의 적용과 예비설계에의 응용 (Application of High-temperature 3-phase Equilibrium Distribution to Dry Scrubber for the Simultaneous Removal of $SO_2$ and Vinyl Chloride)

  • 구자공;백경렬
    • 한국대기환경학회지
    • /
    • 제6권1호
    • /
    • pp.85-96
    • /
    • 1990
  • Simultaneous removal efficiencies of hydrophilic and hydrophobic gaseous pollutants are experimentally determined, and the macroscopic removal mechanism of pollutants in a dry scrubber is analyzed using the extended model of three phase equilibrium distribution of pollutant at high temperatures that can describe the different morphological conditions of adsorbent and water at varying relative humidities. For the simplicity, the inside of spray dryer is divided into three regions of ; (1) absorption, (2) three-phase equilibrium, and (3) adsorption, and the removal efficiencies of each pollutants at three regions are observed at different experimental conditions to estimate the effects of important parameters of dry scrubber. The laboratory experiments simulate the three regions of spray dryer with the temperature control and thus evaporation rate of water from the slurry particle. $SO_2$ as a hydrophilic gaseous pollutant and vinyl chloride as a hydrophobic toxic gas are selected for the future field application to soid waste incineration, and the two types of slurry are made of the two sorbents ; 10 wt.% $Ca(OH)_2$, and 10 wt.% NaOH. Result of temperature effect shows the height of absorption plus three-phase region is decreased as the operation temperature is increased, which results in the lower removal efficiency of $SO_2$ but higher removal for vinyl chloride in the adsorption region of dry scrubber. The removal efficiency of $SO_2$ is higher by NaOH slurry than by $Ca(OH)_2$ slurry due to the hygroscopic nature of NaOH, while the removal of vinyl chloride is higher in $Ca(OH)_2$ case. From the analysis of redults using three-phase equilibrium distribution model, the effective two-phase partition coefficients can be obtained, and the possible extention in the application of the three-phase equilibrium model in a dry scrubber design has been demonstrated.

  • PDF

항산화 필터 제조 및 주류연중 free radicals 제거 효과 (The Manufacture of Antioxidant Filter and Removal Efficiency of the Free Radicals in Mainstream Smoke)

  • 김수호;차성제;심원택;정봉수;서만석;송인범;장행현;신창호;김종열;김정열;최윤주
    • 한국연초학회지
    • /
    • 제31권1호
    • /
    • pp.18-28
    • /
    • 2009
  • This study describes the manufacturing method of antioxidant filter and evaluate the reduction of free radical and biological activity from mainstream smoke. When we used spray-brush for the application of antioxidant solution to the filter, cv(coefficient of variation) levels of antioxidant added to filter ranged within 3 %, which means stable and constant feeding process. 0.3~0.5mg per cigarette of antioxidant were sprayed to acetate and active carbon part in the filter plug, respectively. It was considered that the use of antioxidant added filter resulted in the reduction of the gaseous compounds of free radicals from 17 % to 19 % in the mainstream smoke. Variation for removal efficiency of free radical in antioxidant filter added to acetate part was more pronounced than that of filter added to active carbon part. Smoking deliveries of tar, nicotine for the antioxidant added filters were similar when comparing to the non-antioxidant added filter, but the delivering amounts of isoprene were significantly reduced. The estimation of consumed GSH(glutathion) showed that the gaseous toxicity of the antioxidant added filter was 14 % ~ 23 % lower than that of non-antioxidant added filter. No significant differences were observed for the total taste quality in sensory evaluation.