• 제목/요약/키워드: Gas-generator

Search Result 757, Processing Time 0.789 seconds

LNGC용 Power Management System 시뮬레이터 모델링 및 특성분석 (Power Management System Simulator Modeling and Characteristics Analysis for Electric Propulsion Ship)

  • 김영민;전경원;정상용
    • 전기학회논문지
    • /
    • 제64권6호
    • /
    • pp.878-884
    • /
    • 2015
  • In this paper, Power Management System(PMS) simulator for Liquid Nature Gas Carrier(LNGC) is developed. Major components of power system for LNGC, such as generator, diesel engine and governor, transformer, circuit breaker, and 3 phase loads models are built based on MATLAB/SIMULINK. With these designed major parts, PMS simulator modeling is carried out. Based on MATLAB/Graphical User Interface, PMS simulator control for LNGC, and Human Machine Interface for monitoring is designed. PMS simulator for LNGC carries out simulation according to sequence of characteristics analysis. By comparing results of predicted simulation for each sequence to that of characteristics analysis, the reliability of PMS simulator for LNGC will be verified.

태양광에너지전원의 주간설비이용율 추정에 관한 연구 (A Study on the Weekly Capacity Factor Assessment of Solar Cell Generator)

  • 박정제;오량;최재석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.468_469
    • /
    • 2009
  • The application of renewable energy in electric power systems is growing rapidly in order to make provision for the inequality of the climate, the dwindling supplies of coal, oil and natural gas and a further rise in oil prices. Solar cell generators(SCG) is one of the fastest growing renewable energy. A study on the renewable energy is getting more important for the application of renewable energy. This paper presents the capacity factor of SCG by calculating the probabilistic production energy of SCG.

  • PDF

촉매연소기에서 2단 공급공기와 연료가 NOx 저감에 미치는 연구 (NOx Reduction with Secondary Air and Fuel in a Catalytic Combustor)

  • 정진도;이보영
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.541-549
    • /
    • 2003
  • A basic experimental study was conducted in order to find the optimum combustion control technology to decrease the thermal NO$_{x}$, by applying the catalytic combustion method with natural gas. NO$_{x}$ emission increased with increasing space velocity due to temperature rising in the furnace. In order to overcome the low resistance to high temperature, secondary air was supplied to the CST combustor. The following secondary fuel formed combustible mixture in part, which resulted in steep increase of the exiting temperature of the 2nd catalyst bed. It led to the more generator of NO$_{x}$, 30∼60% of the 1 st catalyst bed. It might be due to the potential increase of thermal NO$_{x}$.

복합사이클 발전플랜트 폐열회수 보일러의 열역학 제1법칙 및 제2법칙 해석 (Performance Evaluation of Heat Recovery Steam Generator in Combined Cycle Gas Turbine Power Plants Based on First and Second-Law Analysis)

  • 인종수
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2010년도 추계학술발표논문집 2부
    • /
    • pp.684-687
    • /
    • 2010
  • 본 논문은 복합사이클 발전플랜트의 폐열회수 보일러 최적운전 및 최적설계에 대한 새로운 접근 방법을 도출하기 위해 폐열회수 보일러에서 발생되는 증기로 증기터빈을 구동하는 하부사이클 효율을 검토하였다. 열역학 제1법칙 해석을 통해 하부사이클 에너지 평형을 검토하였고, 열역학 제2법칙을 통해 엑서지 평형을 검토하였다. 하부사이클 효율이 최대가 되는 폐열회수 보일러를 설계하기 위해서는 열역학 제1법칙을 해석할 경우 하부사이클 전체를 해석하여야 함을 알 수 있다. 하지만, 열역학 제2법칙을 통한 엑서지 해석을 행할 경우 하부사이클 효율이 최대가 되는 증발온도와 폐여회수 보일러에서 소모되는 엑서지가 최소가 되는 점이 일치함을 알 수 있었다. 따라서 본 논문을 통해 폐열회수 보일러에서 소모되는 엑서지 해석을 통해 하부사이클 효율이 최대가 되는 폐열회수 보일러 최적화가 가능함을 알 수 있다.

  • PDF

액체로켓엔진 비상보호시스템 연구 (Study on the Emergency Protection System of Liquid Rocket Engine)

  • 김승한;한영민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.97-103
    • /
    • 2011
  • 본 논문에서는 엔진 비상보호시스템 구성 시 주요 고려 사항과 엔진 선행 개발 시험에서의 적용사례를 제시하였다. 액체로켓엔진 선행 개발 시험을 위해 적용된 비상보호시스템은 시험 중 발생한 모든 오작동 상황에서 오류 없이 작동하여 시험을 중지함으로써 추가적인 오작동의 전파를 방지하여 시험시제와 시험설비를 안전하게 보호하는 역할을 성공적으로 수행하였다. 본 연구 결과는 향후 엔진시험을 위한 비상보호시스템 개발 시 유용하게 활용될 것이다.

  • PDF

Analytical and sensitivity approaches for the sizing and placement of single DG in radial system

  • Bindumol, E.K.;Babu, C.A.
    • Advances in Energy Research
    • /
    • 제4권2호
    • /
    • pp.163-176
    • /
    • 2016
  • Rapid depletion of fossil based oil, coal and gas reserves and its greater demand day by day necessitates the search for other alternatives. Severe environmental impacts caused by the fossil fire based power plants and the escalating fuel costs are the major challenges faced by the electricity supply industry. Integration of Distributed Generators (DG) especially, wind and solar systems to the grid has been steadily increasing due to the concern of clean environment. This paper focuses on a new simple and fast load flow algorithm named Backward Forward Sweep Algorithm (BFSA) for finding the voltage profile and power losses with the integration of various sizes of DG at different locations. Genetic Algorithm (GA) based BFSA is adopted in finding the optimal location and sizing of DG to attain an improved voltage profile and considerable reduced power loss. Simulation results show that the proposed algorithm is more efficient in finding the optimal location and sizing of DG in 15-bus radial distribution system (RDS).The authenticity of the placement of optimized DG is assured with other DG placement techniques.

광대역 과도전압 차단장치의 설계 및 제작 (Design and Fabrication of Wide-band Transient Voltage Blocking Device)

  • 송재용;이종혁;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1999년도 춘계종합학술대회
    • /
    • pp.330-334
    • /
    • 1999
  • This paper presents a new transient voltage blocking device (TBD) for commucation facilities with low power and high frequency bandwidth. Conventional protection devices have some problems such as low frequency bandwidth, low energy capacity and high remnant voltage. In order to improve these limitations, the new TBD, which consists of a gas tube, avalanche diodes and junction type field effect transistors (JFETs), was designed and fabricated JFETs were used as an active non-linear element and a high speed switching diode with low capacitance limits high current. Therefore the avalanche diodes with low energy capacity are protected from the high current, and the TBD has a very small input capacitance. From the performance test using surge generator, which can produce 1.2/50${\mu}\textrm{s}$ 4.2 k$V_{max}$, 8/20${\mu}\textrm{s}$ 2.1 kA$\sub$max/, it is confirmed that the proposed TBD has an excellent protection performance in tight clamping voltage and limiting current characteristics.

  • PDF

발전기(發電機)의 가능출력곡선(可能出力曲線)에 관한 연구(硏究) (A Study on the Generator Capability Curve)

  • 박성진;남시복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 전문대학교육위원 P
    • /
    • pp.35-42
    • /
    • 1999
  • As our power system has changed the past undeveloped model causing the lacked supply of power to the civilized model that the remained one makes the voltage and the frequency rise at the middle of the night, the leading power factor operation of generators, that is, the under-exited operation is essentially to be needed, so, at a viewpoint of the stability of the power system, it is a very important factor. In this investigation. the equation of curves for each area on the capability curve has been studied at the above-mentioned viewpoint. Also, each capability curve for the operating power stations (Nuclear P/S, Thermal P/S, Hydrolic & pumping-up P/S Gas turbine P/S) has, been presented, and studied whether the leading power factor operational area is able to be expanded or not.

  • PDF

합성시험법을 이용한 진상소전류 성능검증에 관한 고찰 (Review for verification of capacitive current performance by using synthetic testing method)

  • 박승재;김용식;박용환;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.466-467
    • /
    • 2006
  • Several synthetic testing methods have widely been used for the performance evaluation of ultra high-voltage circuit breaker. Among these synthetic method, in the paper, capacitance switching testing method which can meet the test requirements and increase the testing capacity has been proposed. This method is made up of two separated sources of short-circuit generator for current source and L-C resonance circuit for voltage source. By using this method, KERI will perform the performance evaluation of capacitive current switching performance for the 800kV GCB(Gas Circuit Breaker).

  • PDF

수냉형 직렬방식 2중효용 흡수식 냉방기의 열해석과 최적 설계 (Thermal Analysis and Optimum Design of Water-Cooled, Series-Flow Type, Double-Effect Absorption Heat Pump)

  • 오명도;김영률;김선창;김영인
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.332-341
    • /
    • 1992
  • An absorption heat pump cycle has been modeled and simulated to analyze the system performance of water-cooled, series-flow, double-effect absorption heat pump, which can be applied to a direct gas fired cooling system with the medium range of cooling capacity (15RT level). Effect of absorption cooling system parameters, such as concentration difference, inlet temperature of cooling water, 1st generator temperature, leaving temperature differences of condenser and evaporator and efficiency of solution heat exchanger, has been investigated in the view of system cooling performance.

  • PDF