• 제목/요약/키워드: Gas-Insulated Switchgear

검색결과 223건 처리시간 0.022초

GIS 예방진단 시스템을 위한 정시간성 보장형 통신기기 개발 (Development on Communication Device with Timeliness Guaranteed for "GIS Preventive and Diagnosis System")

  • 민병운;명희철;최호웅;박창선;김정한;이병호;박동호;김윤관;이동철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2032-2033
    • /
    • 2007
  • There has been increasing interests of condition monitoring and diagnosis for electric equipment, which lead to the development of this system domestic and abroad. In the past, operators' interest was how to quickly repair and restore the electric equipments after failure. But, due to the North American Blackout in 2003 and the aging of equipments, users have paid attention to the condition based monitoring of electric equipment to prevent a fault like outrage. GIS-PDS("GIS Preventive and Diagnosis System") requiresa large amount of measurement data with timeliness for monitoring and analysis of real-time state of GIS(Gas Insulated Switchgear). We developed the timeliness-guaranteed communication device for GIS-PDS.

  • PDF

GIS 스페이서 내장형 저전력 측정용 변압기의 설계 및 제작 (Design and Fabrication of an LPVT Embedded in a GIS Spacer)

  • 박성관;이경렬;김남훈;김철환;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제37권2호
    • /
    • pp.175-181
    • /
    • 2024
  • In electrical power substations, bulky iron-core potential transformers (PTs) are installed in a tank of gas-insulated switchgear (GIS) to measure system voltages. This paper proposed a low-power voltage transformer (LPVT) that can replace the conventional iron-core PTs in response to the demand for the digitalization of substations. The prototype LPVT consists of a capacitive voltage divider (CVD) which is embedded in a spacer and an impedance matching circuit using passive components. The CVD was fabricated with a flexible PCB to acquire enough insulation performance and withstand vibration and shock during operation. The performance of the LPVT was evaluated at 80%, 100%, and 120% of the rated voltage (38.1 kV) according to IEC 61869-11. An accuracy correction algorithm based on LabVIEW was applied to correct the voltage ratio and phase error. The corrected voltage ratio and phase error were +0.134% and +0.079 min., respectively, which satisfies the accuracy CL 0.2. In addition, the voltage ratio of LPVT was analyzed in ranges of -40~+40℃, and a temperature correction coefficient was applied to maintain the accuracy CL 0.2. By applying the LPVT proposed in this paper to the same rating GIS, it can be reduced the length per GIS bay by 11%, and the amount of SF6 by 5~7%.

72.5kV GIS 전력 장비의 KEPCO 기준 내진 및 응력 해석 (Seismic and Stress Analysis of 72.5kV GIS for Technical Specification of KEPCO)

  • 이재환;김영중;김소울;방명석
    • 한국전산구조공학회논문집
    • /
    • 제30권3호
    • /
    • pp.207-214
    • /
    • 2017
  • 국내의 72.5kV 이상, 주파수 60Hz의 송배전설비인 옥내 및 옥외용 가스절연개폐장치(GIS)는 내진 안전성에 대해 국가에서 정한 한전표준규격(ES-6110-0002)을 만족해야 한다. 이 규격에서 명시되지 않은 사항은 IEC 62271-203, 62271-207 등의 관련 기기 규격에 준한다. 한전표준규격에서 기기는 정상사용상태와 특수사용상태에서 건전성이 유지되어야 한다. 안전성 판단을 위해 ASME BPVC SEC.VIII 내압용기 설계 기준에 의해 A6061-T6 재질의 GIS에 대한 정상사용상태 기준과 국내 한전표준규격과 국외 IEC 62271-207에 의한 특수사용상태 기준(지진)에 대한 총체적 응력상태를 판단하였다. 한전표준규격 기준(0.22g) 적용시, 최종응력이 알루미늄인 Part A는 78.2MPa, Part D2의 경우 102.3MPa로, ASME 허용응력 값 181.5MPa를 만족하고 있다. IEC 62271-207 High 0.5g의 경우에도 최종응력은 Part A는 90.5MPa, Part D2는 103.8MPa이다. 본 연구 결과, 72.5kV GIS는 한전표준규격의 구조안전성과 내진성능을 충분히 만족함을 보이고 있다. 내진해석으로 내진시험을 수행할 수 없는 대형 전력기기의 내진성능 실증에 활용될 수 있을 것으로 기대된다.