• Title/Summary/Keyword: Gas safety

Search Result 2,926, Processing Time 0.027 seconds

Research for Detailed Technical Standards of Exposure Pipe (노출배관의 세부 기술기준 연구)

  • Kang, Byung-IK;Park, Woo-Il;Yim, Sang-Sik;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.13-19
    • /
    • 2018
  • The exposed pipe requires higher durability because is directly contacted with the outside air unlike the buried pipe. For this purpose, clear detailed technical standards are essential in the design and construction of piping systems. However, the existing technical standards were not able to evaluate the durability considering the characteristics of piping, so many questions were raised in the field. Therefore, through the present study, the existing detailed technical standards are revised to propose measures to secure the durability of exposed piping.

A Study on the Effectiveness of Gas Safety Devices for Domestic (가정용 가스안전기기의 실효성에 관한 연구)

  • Jo Young-Do;Lee Kyung-Sik;Jang Sung-Dong;Kim Ji-Yun
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.62-69
    • /
    • 2001
  • Gas safety devices are very effective to prevent catastrophic gas accident in domestic. The safety devices are included in domestic gas equipment such as extinguishing safety device and adapted at pipeline such as fuse cock, shut off device with gas alarm and so forth. In spite of using those safety devices, a few hundreds of gas accident was happened annually in residential house. In this study, we analysed systematically the domestic accidents which was happened in five years using fault tree analysis(FTA) method and analysed the effectiveness of individual safety device. And also, it was suggested that the rate of accident was decreased quantitatively by increasing safety device which is adapted in domestic. By analysis of 769 gas accidents in domestic, the order of effectiveness of safety device to prevent domestic gas accident was the multi-functional gas-safe-meter(micom-meter), fuse cock, gas leak alarm and CO alarm. If the above four kind of safety device are adapted to every house, about $59\%$ of accident will be reduced and the most of catastrophic gas accident will be Prevented in domestic.

  • PDF

A Study on the Safety Management Methods of Micro-Gas Engine Combined Heat and Power System (소형 가스엔진 열병합발전 시스템의 안전관리 방안에 관한 연구)

  • Kim, So-Hyun;Kim, Min-Woo;Lee, Eun-Kyung;Lee, Jung-Woon
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.76-89
    • /
    • 2018
  • The distribution of the combined heat and power system is active as a solution to the instability of energy supply and environmental pollution caused by continuous industrial development. In Korea, the safety standards for combined heat and power system using a gas engine are insufficient therefore the study on this is needed. In this study, the safety performance and structural/material assessment items of domestic and international standards applied to the combined heat and power system were analyzed to carry out a standardization study on safety performance applicable to 20 kW gas engine combined heat and power system. In addition, the safety performance assessment (plan) of the gas engine combined heat and power system was derived by performing risk analysis and risk assessment using HAZOP. Assessment items include engine ignition systems related to safety performance, piping tight performance, watering and temperature rise performance, combustion performance, electrical efficiency, thermal efficiency, overall efficiency and humidity performance. Gas and water pipes, gas control and shut-off valves, durability, heat resistance, and cold resistance of metal or non-metallic materials related to the structure and materials of the gas engine combined heat and power systems.

A Study on Installation of Carbon Monoxide Detector in a Building (건축물내 일산화탄소 경보기 설치에 관한 연구)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Oh, Jeong-Seok
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2008.04a
    • /
    • pp.217-222
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

A Study on Autonomic Analysis for Servicing Intelligent Gas Safety Management Based on RFID/USN (RFID/USN 기반 지능형 가스안전관리 서비스를 위한 자율적 분석 연구)

  • Oh, Jeong-Seok;Choi, Kyung-Seok;Kwon, Jeong-Rock;Yoon, Ki-Bong
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.51-56
    • /
    • 2008
  • As RFID/USN technology is used in the latest industry trend, the information analysis paradigm shifts to intelligence service environment. The intelligent service includes autonomic operation, which select activity by defining itself to the status of industry facilities. Furthermore, information analysis based on IT used to frequently data mining for detecting the meaning information and deriving new pattern. This paper suggest self-classifying of context-aware by applying data mining in gas facilities for serving the intelligent gas safety management. We modify data algorithm for fitting the domain of gas safety, construct context-aware model by using the proposed algorithm, and demonstrate our method. As the accuracy of our model is improved over 90%, the our approach can apply to intelligent gas safety management based on RFID/USN environments.

A Study on the Prediction of the Maximum Evaporation Rates from LPG Storage Tanks (소형저장탱크의 가스발생능력에 관한 연구)

  • Lee Kyung-Sik;Yu Kwang-Soo;Jo Young-Do;Park Kyo-Shik
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.1 s.30
    • /
    • pp.7-12
    • /
    • 2006
  • The quantity of gas which can be supplied by LPG storage tank become a standard of selection. In the absence of the maximum evaporation rates from LPG storage tanks by tank capacity, continuation using time, air temperature, it is in a problem for the dissemination of LPG Storage tanks. In this paper, we showed the maximum evaporation rates from LPG storage tanks by tank capacity, air temperature, continuous using time and remaining level.

  • PDF

Temperature Variations of Air Pocket in Type-3 Composite Vessel during Ambient Hydraulic Cycling Test (상온 수압반복시험 시 Type 3 복합재용기 내 공기층의 온도변화)

  • Cho, Sung-min;Kim, Kwang Seok;Kim, Chang Jong;Lyu, Geun-jun;Lee, Yeon-jae;Jo, Yun Seong;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.120-125
    • /
    • 2015
  • This research aims to increase the reliability and reproducibility of the ambient cycling test by properly making corrections to the test procedure. The vessel (106 L) is initially filled with 70 L of water and horizontally placed on a balance. The pressure range inside the vessel varies from 2.5 to 25.9 MPa at the frequency of 6 cycles per minute. After reviewing the results, there was a temperature difference of approximately $10^{\circ}C$ between the air pocket and the water, and the upper part of the liner faced a repeated temperature change of $40^{\circ}C$. It is possible for the aluminum liner of the composite vessel to be damaged by such a sharp change in temperature. Additionally, as a result, no pass having anything to do with the purpose of the test would occur. Therefore, it is suggested that the air pocket be completely removed.

An Experimental Study on Thermal Efficiency Characteristics with Propane-DME Mixture Ratio for Residential Gas Range (Propane-DME 혼합비율에 따른 가정용 가스레인지의 열효율 특성에 관한 실험적 연구)

  • Ahn, Jae-Uk;Hwang, Hyun-Cheol;Kim, Young-Gyu;Kwon, Jeong-Rock
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.81-84
    • /
    • 2008
  • In this paper, the research was applied the mixture gas of Propane-DME (dimethyl ether) for being commercialization to residential gas ranges. In order to examine a correspondence between Korean Standard and thermal efficiency characteristics at each burner, experiments were performed with 100% Propane and the mixture gas of 80% Propane-20% DME. The experimental results were shown that the higher a mixture ratio of DME was used, the lower a thermal efficiency was gained. Those were due to low caloric value of DME. With 80% Propane-20% DME mixture gas, one of residential gas ranges was not satisfied the condition for the thermal efficiency value, 40%, Korean Standard. Consequently, the research needs about the standard for being commercialization to the mixture gas of Propane-DME.

  • PDF

Development of the Safety Cabinet for Respiratory High-Pressure cylinder according to Consequence Analysis of Physical Explosion Damage (호흡용 고압용기 파열 피해영향 분석에 따른 안전충전함 개발)

  • Jang, Kap Man;Kim, Jeong Hwan;Jang, Yu Ri;Lee, Jin Han;Jo, Young Do
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.80-88
    • /
    • 2016
  • A fire station and scuba have operated filling facilities for respiratory high-pressure cylinder without getting authority or reporting according to High-Pressure Gas Safety Control Act. They need facility improvement and special management to make provision for the time of accident during filling process. The Government have strived to correct illegal operations and suggested an alternative, establishing and operating the safety cabinet. It insures a safety being distance from danger caused by overpressure and a safety provoked by the protective wall equals or superiors. The safety cabinet is required to have an internal structure that smoothly distribute overpressure at the time of rupture. Plus, it needs to minimize fragments. It is also equipped with the performance of protective wall that makes overpressure to outside vent on the place where there is no person (top or bottom). This study calculated the consequence of physical explosion damage and built a prototype of safety cabinet. In addition, through the gas burst test, it derives for the ways to mitigate the physical explosion damage.

A Study on the Influence of the Organic Matter Contents in Soil Deposited of Chlorine Gas (염소의 토양 침적특성에 미치는 토양 내 유기물 함량의 영향)

  • Song, Bo Hee;Lee, Kyung Eun;Yim, Sang Sik;Lee, Jin Han;Jo, Young Do
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.1
    • /
    • pp.1-5
    • /
    • 2017
  • In the event of toxic gas accidents, soil deposition is a main factor which has an effect on extent of the damage. In this study, it presents the influence of soil deposition properties according to the change of soil depth and the organic matter contents in soil. In this experimentation, the soil deposition device developed in Air Force Research Laboratory in USA is recreated. The tested samples of mixing soil have each value of the organic matter contents. After a variety of synthetic soil were exposed to constant Cl2 concentration, the chlorinity is measured using an anion exchange chromatography(ICS-1100) to quantify the mount of deposition. As the results, the increase of soil depth causes an decreased soil deposition and the increase of exposure time causes an increased soil deposition in surface. Also, the increase of soil deposition mainly depended on the organic matter contents in surface.