• 제목/요약/키워드: Gas removal efficiency

검색결과 557건 처리시간 0.03초

Removal of Hydrogen Sulfide and Methylmercaptan Using Thiobacillus in a Three Phase Fluidized Bed Bioreactor

  • KIM, KYUNG-RAN;KWANG-JOONG OH;KYUNG-YONG PARK;DONGUK KIM
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권3호
    • /
    • pp.265-270
    • /
    • 1999
  • A three phase fluidized bed bioreactor immobilized with Thiobacillus sp. IW was tested to remove hydrogen sulfide and methylmercaptan with high loading rate. In a single gas treatment, the bioreactor removed 92- 98% of hydrogen sulfide with loading rate of 15- 66 g/l/h and removed 87-98% of methylmercaptan with loading rate of 14-60 gl/sup -1/h/sup -1/. In the mixed gas treatment, the removal efficiencies of hydrogen sulfide and methylmercaptan maintained at 89-99% for various inlet loading rates and were not affected by the inlet loading ratio of both gases in low loading rates. When the inlet concentration of methylmercaptan increased 3.8 times and was maintained for 30 h to observe the response of the bioreactor to sudden environmental change, the removal efficiency of methylmercaptan was maintained at an average of 91%.

  • PDF

펄스 스트리머 방전을 이용한 NOx 제거 (Removal of NOx by Pulsed Streamer discharge)

  • 고희석;박재윤;김건호
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권8호
    • /
    • pp.807-811
    • /
    • 1997
  • In this paper we have investigated the removal characteristics of NOx by pulsed corona discharge with a multi-pointplane electrode where a magnetic field is applied in the discharge region. The efficiency of NOx removal was measured and analyzed as a function of pulse frequency gas flow rate NOx initial concentration magnetic flux density. In this result the highest removal efficiency of NOx was obtained at the following operating conditions; the frequency =400[Hz] gas flow =1[$\ell$/min] initial concentration= 400[ppm] and magnetic flux density=0.36[T].

  • PDF

이산화탄소 5 ton/day 흡수분리 Pilot Plant 운전 특성 (The Operational Characteristics of CO2 5 ton/day Absorptive Separation Pilot Plant)

  • 오민규;박소진;한근희;이종섭;민병무
    • Korean Chemical Engineering Research
    • /
    • 제50권1호
    • /
    • pp.128-134
    • /
    • 2012
  • 석탄화력 발전소의 연소 배가스를 시간당 1,000 $Nm^3$을 처리할 수 있는 이산화탄소 분리용 pilot plant를 설치하여 화학흡수제인 mono-ethanolamine(MEA)과 2-amino-2-methyl-1-propanol(AMP)를 이용해서 운전특성을 연소 배가스 유량과, 흡수용액 순환유량을 주 실험변수로 분석하였다. MEA 20 wt%를 기준으로 연소 배가스 유량이 100 $m^3/hr$ 감소할수록 이산화탄소 제거율이 평균 6.7% 증가하였으며 흡수용액 순환유량이 1,000 kg/hr 증가에 따라 이산화탄소 제거율은 약 2.8% 상승하였고 $110^{\circ}C$ 재가열기 온도에서 90% 이상의 이산화탄소 제거효율을 나타냈다. MEA가 AMP보다 높은 제거효율을 보였고 MEA(20 wt%) 실험에서 이산화탄소의 제거율이 75.5%인 ASPEN plus의 모사 결과보다 10% 높은 85.5%로 나타났다.

관성 충돌 방식의 액적 분리장치의 수분제거효율 평가 (Evaluation of Removal Efficiency of Water Contents using Inertial Impaction Separator)

  • 이신영;홍원석;신완호;김규진;송동근
    • 한국입자에어로졸학회지
    • /
    • 제9권1호
    • /
    • pp.23-29
    • /
    • 2013
  • Inertial impaction type mist eliminators are the most effective instruments to separate mist from the gas. In this work, the effect of the horizontal chevron type mist eliminators is characterized experimentally. Droplet size distribution and evaluation of removal efficiency of the chevron type mist eliminators at different gas flows were investigated using an aerosol particle size analyzer and a portable aerosol spectrometer, respectively. The experimental investigations showed that the mist removal efficiency in these instruments is dependent in the droplet size, and the pressure drop is nil.

실험실 규모 정전기 분무형 반건식 세정기의 SO2 제거효율 향상에 대한 계산 및 실험적 연구 (Numerical and Experimental Study on the Increase of Removal Efficiency of SO2 in a Laboratory Scale Electrostatic Spray Drying Absorber)

  • 변영철;황정호
    • 대한기계학회논문집B
    • /
    • 제22권8호
    • /
    • pp.1111-1120
    • /
    • 1998
  • Spray Drying Absorber(SDA) system, where the combustion product gas is mixed with atomized limestone-slurry droplets and then the chemical reaction of $SO_2$ with alkaline components of the liquid droplets forms sulfates, has been widely used to eliminate $SO_2$ gas from coal fired power plants and waste incinerators. Liquid atomization is necessary because it can maximize the reaction efficiency by increasing the total surface area and dispersion angle of the alkaline components. First, numerical calculations using FLUENT are carried out to investigate $SO_2$ concentration distribution and thus to calculate $SO_2$ removal efficiency. So to attain the optimized spray conditions, then an electrostatic spraying system is set up and spray visualization is performed to show the effect of an electric field on overall droplet size. Next, the effect of an electric field on the concentrations of $SO_2$ is experimentally examined. Field strength is varied from -10 kV to 10 kV and configurations of conduction charging and induction charging are utilized. Consequently, the electrostatic removal efficiency of 501 increases about 30% with the applied voltage of ${\pm}10kV$ but is independent of polarity of the applied voltage. It Is also found that the conduction charging configuration results in higher efficiency of $SO_2$ removal that the induction charging configuration. Finally, the effect of slurry temperature on $SO_2$ removal is studied. The temperature influences on the electrostatic removal efficiency of $SO_2$.

다공성 세라믹 Biofilter를 이용한 Toluene 가스 제거 (Removal of Toluene Vapor by Porous Ceramic Biofilter)

  • 임재신;구자공;박상진
    • 한국대기환경학회지
    • /
    • 제14권6호
    • /
    • pp.599-606
    • /
    • 1998
  • Removal of toluene vapor from airstreams was studied in a biological reactor known as a biofilter. The biofilter was packed porous ceramic inoculated with thickened activated sludge (MLVSS 17,683 mg/L). The lab-scale biofilter was operated for 42 days under various experimental conditions including inlet toluene concentrations and flow rates of the contaminated air streams. Removal efficiency reached up 96.6% after 4 days from start up. Nutrient limitation was proposed as a reason for the decrease in biofilter performence. Biofilter performance decreased substantially, coincident with the buildup of back pressure due to accumulation of excess VSS within the medium bed. Practically, the bed needs to be backwashed when the overall pressure drop is greater than 460.6 Pa at SV (Space Velocity) 100 h-1. Periodic backwashing of the biofilter was necessary for removing excess biomass and attaining stable long -term high removal efficiency The removal efficiency of toluene in the biofilter decreased as the gas velocity and toluene concentration in the inlet gas increased. The maximum elimination capacity of ceramic biofilter could reach up to 444.85 g/m3. hr. When the loading of toluene exceed this critical value, substrate inhibition occurred.

  • PDF

액상 균일질 촉매를 이용한 $SO_2/NO$ 동시 처리 기술 개발 (Simultaneous Removal of $SO_2/NO$ using liquid Homogeneous Catalyst)

  • 정승호;배진열;박돈희;정경훈;차진명
    • 대한환경공학회지
    • /
    • 제29권1호
    • /
    • pp.62-67
    • /
    • 2007
  • 본 연구의 목적은 액상 균일질 촉매를 이용하여 연소가스 중에 포함되어 있는 $SO_2/NO$의 동시제거 기술 개발에 있다. 연구는 bench scale/소규모 pilot scale에서 이루어졌으며 연구 결과는 다음과 같다. 1) $SO_2$는 실험조건에 상관없이 높은 제거효율을 가지는 것으로 확인되었다. 그러나 NO의 경우 충진층 높이가 증가할수록, 농도가 낮을수록, 촉매 분사량이 증가할수록 제거효율이 증가하는 것으로 나타났다. 2) Fe(II)-EDTA를 이용한 $SO_2/NO$ 동시처리 기술 개발을 위한 최적의 설계 인자는 충진 높이 =0.5 m, 액체-기체비 = 20 $L/m^3$, 반응기 단수=3단, 반응기 단면적 = 0.025 $m^2$로 결정하였다. 3) 연구 결과를 기초로 $SO_2/NO$의 동시처리 효율을 실험한 결과 각각 95%, 81% 이상 제거가 가능했다. 4) 높은 HTU는 NO의 제거에 있어 유리하지만 과도한 HTU는 스크러버의 운전효율을 감소시키므로 최적의 HTU를 결정하는 것이 필요하다.

실험계획법을 이용한 가스 혼합-순환식 플라즈마 공정의 최적화 (Optimization of Gas Mixing-circulation Plasma Process using Design of Experiments)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.359-368
    • /
    • 2014
  • The aim of our research was to apply experimental design methodology in the optimization of N, N-Dimethyl-4-nitrosoaniline (RNO, which is indictor of OH radical formation) degradation using gas mixing-circulation plasma process. The reaction was mathematically described as a function of four independent variables [voltage ($X_1$), gas flow rate ($X_2$), liquid flow rate ($X_3$) and time ($X_4$)] being modeled by the use of the central composite design (CCD). RNO removal efficiency was evaluated using a second-order polynomial multiple regression model. Analysis of variance (ANOVA) showed a high coefficient of determination ($R^2$) value of 0.9111, thus ensuring a satisfactory adjustment of the second-order polynomial multiple regression model with the experimental data. The application of response surface methodology (RSM) yielded the following regression equation, which is an empirical relationship between the RNO removal efficiency and independent variables in a coded unit: RNO removal efficiency (%) = $77.71+10.04X_1+10.72X_2+1.78X_3+17.66X_4+5.91X_1X_2+3.64X_2X_3-8.72X_2X_4-7.80X{_1}^2-6.49X{_2}^2-5.67X{_4}^2$. Maximum RNO removal efficiency was predicted and experimentally validated. The optimum voltage, air flow rate, liquid flow rate and time were obtained for the highest desirability at 117.99 V, 4.88 L/min, 6.27 L/min and 24.65 min, respectively. Under optimal value of process parameters, high removal(> 97 %) was obtained for RNO.

박용디젤기관의 대기오염 저감을 위한 습식 다단 임팩션 시스템의 집진특성 (Collection characteristics of wet-type multi-staged impaction system for air pollutants removal of marine diesel engines)

  • 여석준;권준형
    • 수산해양기술연구
    • /
    • 제52권3호
    • /
    • pp.248-256
    • /
    • 2016
  • The main purpose of this paper was to analyze the removal characteristics of gas/particulate phase pollutants for the present system. Experimentally, we performed to estimate the pressure drop and air pollution removal efficiency with physical variables such as stage number, tube velocity, tube diameter, water spray ($NH_4OH$), and so on. It was concluded that the pressure drop was shown below $111mmH_2O$ lower than that of the existing scrubber (centrifugal spray chamber, over 200 mmAq) at inlet velocity 3.46 m/s and 5 stage. The particular removal efficiency of this system was to be significantly higher at 99.8% in comparison with that of the existing scrubber for 5 stage, inlet velocity 3.46 m/s and $NH_4OH$ (aq) 300 mL/min. It was estimated that the removal efficiencies of $SO_2$ and $NO_2$ were 80% and 70% at system inlet velocity 2.07 m/s and $NH_4OH$ (aq) 300 mL/min respectively. Additionally, the present collection system was to be considered as an effective compact system for simultaneous removal of air pollutants (gas/particulate) due to much higher removal efficiency and appropriate pressure drop without a demister.

충격식 코로나 방전 플라즈마를 이용한 배연가스로부터 먼지제거에 대한 특성 (The Characteristics of Dust Removal in Flue Gas by the Plasma of Impulse Streamer Corona)

  • 김은호
    • 한국환경과학회지
    • /
    • 제12권12호
    • /
    • pp.1261-1267
    • /
    • 2003
  • On the basis of the distribution of particle size measured by laser diffraction spectrometers, this research was carried out to investigate the characteristics of mist removal with the change of operating condition in the plasma reactor of impulse streamer corona. The operating parameters in this experiment were power of impulse streamer corona, gas velocity, impulse generation time, gas temperature, and SOx/NOx concentration. The collection efficiency T(d) was estimated by the distribution of particle size in the collection zone through the advanced model.