• Title/Summary/Keyword: Gas pycnometer

Search Result 6, Processing Time 0.023 seconds

New Method of Volume Measurement for Reference Weights of a Pressure Balance Using a Gas Pycnometer (기체용적계를 이용한 분동식 압력계용 기준분동의 새로운 부피측정 방법)

  • Lee, Yong Jae;Lee, Woo Gab;Mohammed, Mohammed Abdurahman;Park, Yon-Kyu;Oh, Chae Yoon
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.231-237
    • /
    • 2013
  • New method of volume measurement for reference weights of a pressure balance using a gas pycnometer is proposed. The result of volume measurement of proposed method shows the uncertainties of approximately 0.2% at the level of confidence of 95% for reference weights in the ranges of 1 kg, 2 kg, and 5 kg. This measuring system consists of a sample chamber, an expansion chamber, a precision pressure gage, a precison thermometer, a vacuum pump, and helium as a medium gas. The measurement principle of this proposed method is based on Boyle's law. This method will contribute a reliability of the volume measurements of reference weights for a pressure balance to the national measurement standard.

Development of Standard Analysis Methods for Physical Properties on Korean bedsoil 1. Particle density and Bulk density (우리나라 상토의 물리적 표준분석법 설정 연구 1. 입자밀도 및 용적밀도)

  • Kim, Lee-Yul;Cho, Hee-Kee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.35 no.6
    • /
    • pp.327-334
    • /
    • 2002
  • Method of besoil analysis were difficult to be applied universally since the use and the source material of bedsoils are diverse from country to country. Korean Standard Methods for Bedsoil Analysis was developed to measure the particle and bulk density. Fifty-three samples for horticultural bedsoil and nine samples for paddy rice bedsoil in the current market were collected. Particle density was measured by electrical pyconometer with He gas, and bulk density by the sandbox method, free fall method, plunger compaction method, free fall and plunger method, and sample weight compaction method. While the use of glass pycnometer which measures particle density to fill blank space with water was inappropriate due to floating organic and calcined inorganic materials in the water, the electrical pycnometer with gas type was suitable considering speed and accuracy. For bulk density, the sandbox method recommended as European Standard Method was more reasonable in principle than other methods. However, this method requires expensive apparatus and intricate process. Plunger compaction method was proposed as standard method, since it had higher consistence with the sandbox method than other methods, as well as an advantage of easy and prompt measurement. Particle density of bedsoil ranged $1.48{\sim}2.67Mg\;m^{-3}$(mean $1.93Mg\;m^{-3}$) for horticultural bedsoil and $2.33{\sim}2.67Mg\;m^{-3}$ (mean $2.43Mg\;m^{-3}$) for paddy rice bedsoil by the electrical pycnometer with He gas. Bulk density of bedsoil ranged $0.11{\sim}0.40Mg\;m^{-3}$ (mean $0.22Mg\;m^{-3}$) for horticultural bedsoil and $0.84{\sim}1.26Mg\;m^{-3}$(mean $1.01Mg\;m^{-3}$) for paddy rice bedsoil by plunger compaction method.

A Study on Comparison of Density Test Methods for Quality Control of Cement and Mineral Admixture (시멘트 및 혼화재의 품질관리를 위한 밀도 시험방법 비교 연구)

  • Jae-Seung, Lee;Sang-Kyun, Noh;Cheol, Park;Hong-Chul, Shin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.435-442
    • /
    • 2022
  • In this study, the density of KS L 5110 was compared with that of gas pycnometer and electronic densimeter for efficient density management of cement, blast furnace slag powder and fly ash. Correlation and usability according to the test method were reviewed, and based on the results of the experiment, the availability of alternative test methods was analyzed. As a result of the density test according to test methods, the density of cement, blast furnace slag powder and fly ash tended to decrease in the order of gas pycnometer, KS L 5110 and electronic densimeter. Because the volume range of the sample to be evaluated is different depending on test methods. The coefficient of determination R2 was in the range of 0.71 to 0.93, and the correlation according to test methods showed a relatively good correlation. If correction is applied through correlation, it is analyzed that alternative test methods can be used. As a result of the usability review considering the test procedure, measurement time and coefficient of variation, the gas pycnometer had the simplest test procedure and good reliability. In addition, it is expected that the reproducibility between the testers is relatively high because the skill is not greatly required.

Pycnometric and Spectroscopic Studies of Red Phosphors Ca2+(1-1.5x)WO4:Eu3+x and Ca2+(1-2x)WO4:Eu3+x,Na+x

  • Cho, Seon-Woog
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2769-2773
    • /
    • 2013
  • Red phosphors $Ca_{(1-1.5x)}Eu_xWO_4$ and $Ca_{(1-2x)}Eu^_xNa_xWO_4$ were synthesized with various concentrations x of $Eu^{3+}$ ions by using a solid-state reaction method. The crystal structure of the red phosphors were found to be a tetragonal scheelite structure with space group $I4_1/a$. X-ray diffraction (XRD) results show the (112) main diffraction peak centered at $2{\theta}=28.71^{\circ}$, and indicate that there is no basic structural deformation caused by the vacancies ${V_{Ca}}^{{\prime}{\prime}}$ or the $Eu^{3+}$ (and $Na^+$) ions in the host crystals. Densities of $Ca_{(1-1.5x)}Eu_xWO_4$ were measured on a (helium) gas pycnometer. Comparative results between the experimental and theoretical densities reveal that $Eu^{3+}$ (and $Na^+$) ions replace the $Ca^{2+}$ ions in the host $CaWO_4$. Also, the photoluminescence (PL) emission and photoluminescence excitation (PLE) spectra show the optical properties of trivalent $Eu^{3+}$ ions, not of divalent $Eu^{2+}$. Raman spectra exhibit that, without showing any difference before and after the doping of activators to the host material $CaWO_4$, all the gerade normal modes occur at the identical frequencies with the same shapes and weaker intensities after the substitution. However, the FT-IR spectra show that some of the ungerade normal modes have shifted positions and different shapes, caused by different masses of $Eu^{3+}$ ions (or $Na^+$ ions, or ${V_{Ca}}^{{\prime}{\prime}}$ vacancies) from $Ca^{2+}$.

Pore Characterization in Cross Section of Yellow Poplar (Liriodendron tulipifera) Wood

  • Jang, Eun-Suk;Kang, Chun-Won;Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.8-20
    • /
    • 2019
  • This study was conducted to analyze the pore structure of Yellow poplar. Cross-sectional surfaces of heartwood and sapwood of Yellow poplar (Liriodendron tulipifera) were observed by SEM, and the true density of the heartwood, intermediate wood and sapwood were measured by gas pycnometery, while gas permeability and pore size of heartwood, intermediate wood and sapwood were measured by capillary flow porometery. The pores were classified as through pore, blind pore and closed pore. It was determined that the permeability was increased due to the content and size of through pore being increased although the total porosity of specimen showed slight difference from pith to bark. The content of through pore porosity was 33.754 % of heartwood and 47.810 % of sapwood, showed an increasing trend from pith to bark, however, those for the blind pore porosity and closed pore porosity were 27.890 % and 19.492 % for heartwood and 19.447 % and 4.660 % for sapwood, showed a decreasing trend from pith to bark. The max pore size of specimens was increased by about 5 times from $5.927{\mu}m$ to $31.334{\mu}m$, and mean flow pore size was increased by about 315 times from $0.397{\mu}m$ to $12.437{\mu}m$ from pith to bark.

Study on the Granulation Behavior of TiO2-PVA Composite Powders Prepared Via Spray Drying Technique

  • Avcioglu, Celal;Ozkal, Burak
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.5
    • /
    • pp.443-452
    • /
    • 2019
  • In this study, TiO2-polyvinyl alcohol (PVA) composite granules were prepared via spray drying technique. To investigate the effects of solid content and binder/powder ratio in the slurry on the granulation behavior of TiO2 powders, the feed compositions were designed to vary over a wide range. The morphology, actual densities, and average granule size and size distribution of the TiO2-PVA composite granules were characterized by using scanning electron microscopy technique, a gas pycnometer, and an image analyzing program (Image-J), respectively. The results indicate that solid content and the amount of PVA in the feedstock slurry are the dominant factors determining the granule morphology, size, and size distribution of TiO2-PVA composite. Moreover, it was observed that increasing the solid content and the amount of PVA in the slurry improved the granulation process and reduced the granule defects. For the preparation of spherical TiO2-PVA composite granules with the minimum amount of non-granulated powders, the optimized composition of the feedstock slurry was found to be 35 wt.% solid and 3 wt.% PVA.