• 제목/요약/키워드: Gas loop

검색결과 232건 처리시간 0.027초

브레이징식 동세관내 CO2의 냉각 열전달 특성 (Cooling Heat Transfer Characteristics of CO2 in a Brazing Type Small Diameter Copper Tube)

  • 오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.827-834
    • /
    • 2009
  • The cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a $CO_2$ compressor, a mass flow meter, an evaporator and a brazing type small diameter tube as a test section. The mass flux of $CO_2$ is $400{\sim}1600$ [kg/$m^2s$], the mass flowrate of coolant were varied from 0.15 to 0.3 [kg/s], and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The cooling heat transfer coefficients of the brazing type small diameter copper tube is about $4{\sim}11.7%$ higher than that of the conventional type small diameter copper tube. In comparison with test results and existing correlations, correlations failed to predict the cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter copper tube. therefore, it is necessary to develope reliable and accurate predictions determining the cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter copper tube.

건물 에너지 상세 해석을 통한 소형 열병합 발전 및 히트펌프 복합 시스템의 경제성 분석 (Energy and Economic Analysis of Heat Recovery Cogeneration Loop Integrated with Heat Pump System by Detailed Building Energy Simulation)

  • 서동현;고재윤;박률
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.71-78
    • /
    • 2009
  • Up until recently, the energy and the economic analysis of a cogeneration system have been implemented by a manual calculation that is based on monthly thermal loads of buildings. In this study, a cogeneration system modeling validation with a detail building energy simulation, eQUEST, for a building energy and cost prediction has been implemented. By analyzing the hourly building electricity and thermal loads, it enables users to decide proper cogeneration system capacity and to estimate more accurate building energy consumption. eQUEST also verified the energy analysis when the heat pump system is integrated with the cogeneration system. The mechanical system configuration benefits from the high efficiency heat pump system while avoiding the building electricity demand increase. Economic analysis such as LCC (Life Cycle Cost) method is carried out to verify economical benefits of the system by applying actual utility rates of KEPCO(Korea Electricity Power COmpany) and KOGAS(KOrea GAS company).

누설변압기 1차측의 스위칭 제어에 의한 펄스형 $CO_2$레이저에 관한 연구 (A Study on the Pulsed $CO_2$ Laser by the Switching Control of Leakage Transformer Primary)

  • 정현주;이동훈;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권9호
    • /
    • pp.541-545
    • /
    • 2000
  • We propose a pulsed $CO_2$laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantages of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5 Hz to 60 to Hz control laser output. In this laser a low voltage open loop control for high voltage pulse discharge circuit is employed to aviod the Hv sampling or switching and high voltage leakage transformer is used to convert low voltage pulse rectified from AC to high voltage one. A ZCS(Zero Crossing Switch) circuit and a PIC(programble one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leadkage inductance. The maximum laser output was about 23 W at pulse repetition rate of 60Hz total gas mixture of $CO_2$ : $N_2$ : He=1: 9: 15 and total pressure of 18 Torr

  • PDF

방향성 규소강판에서 열화특성이 자기적 성질에 미치는 영향 (Korean Institute of Electrical and Electronic Materials)

  • 김형욱;김인성;정순종;민목기;송재성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.245-246
    • /
    • 2006
  • 방향성 규소강판을 tape-wound core 형태로 제작하여 $N_2$ gas 분위기에서 $760^{\circ}C$ 4 시간동안 열처리후 자기적 특성을 조사 하였다. 그 결과 1차, 2차 권선수가 85 turns 시료에서 보자력(Hc)과 포화자속밀도(Bs)는 최대값을 나타내었고, 보자력은 0.019Oe, 포화자속밀도는 1.92T 이었다. 현재 국내에서 생산되고 있는 방향성 규소강판의 자속밀도값 보다 더 우수한 값을 나타내었으며, 열화특성이 자기적 특성에 미치는 영향을 통해 고효율 방향성 규소강판 개발의 가능성을 확인하였다.

  • PDF

Uncertainty analysis of ROSA/LSTF test by RELAP5 code and PKL counterpart test concerning PWR hot leg break LOCAs

  • Takeda, Takeshi;Ohtsu, Iwao
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.829-841
    • /
    • 2018
  • An experiment was conducted for the OECD/NEA ROSA-2 Project using the large-scale test facility (LSTF), which simulated a 17% hot leg intermediate-break loss-of-coolant accident in a pressurized water reactor (PWR). In the LSTF test, core uncovery started simultaneously with liquid level drop in crossover leg downflow-side before loop seal clearing, and water remaining occurred on the upper core plate in the upper plenum. Results of the uncertainty analysis with RELAP5/MOD3.3 code clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges. For studying the scaling problems to extrapolate thermal-hydraulic phenomena observed in scaled-down facilities, an experiment was performed for the OECD/NEA PKL-3 Project with the Primarkreislaufe Versuchsanlage (PKL), as a counterpart to a previous LSTF test. The LSTF test simulated a PWR 1% hot leg small-break loss-of-coolant accident with steam generator secondary-side depressurization as an accident management measure and nitrogen gas inflow. Some discrepancies appeared between the LSTF and PKL test results for the primary pressure, the core collapsed liquid level, and the cladding surface temperature probably due to effects of differences between the LSTF and the PKL in configuration, geometry, and volumetric size.

다점계류식 FPSO의 해양환경별 계류선 각도와 최대 장력에 대한 연구 (Mooring Layout Angle and Maximum Tension for Spread Moored FPSOs in Various Metocean Conditions)

  • 박성부;이승재;정윤석;이민경;정광효
    • 한국해양공학회지
    • /
    • 제30권4호
    • /
    • pp.253-259
    • /
    • 2016
  • This study demonstrates the result of mooring analysis for five spread-moored FPSOs having different length-to-breadth (L/B) ratios from 4.5–6.5. FPSOs are subjected to four metocean conditions, ones from the Gulf of Mexico (Hurricane/Loop current condition), West Africa, Nigeria, and Brazil Campos Basin, which are amongst the most typical offshore oil and gas fields. With change in design parameters of OBA (Outer bundle angle) and IBA (Inner bundle angle) combinations, a change in the line tension is demonstrated and the OBA-IBA combinations having the smallest line tension are presented for each L/B ratio and sea, respectively. This study is expected to influence the preliminary design layout of an FPSO spread-mooring system as a function of the L/B ratio and metocean conditions.

Extended Injectant Mole-Fraction Imaging of Supersonic Mixing using Acetone PLIF

  • Takahashi, Hidemi;Ikegami, Shuzo;Hirota, Mitsutomo;Masuya, Goro
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.781-789
    • /
    • 2008
  • The fluorescence ratio method for processing planar laser induced fluorescence(PLIF) data was generalized for quantitative imaging of the injectant mole-fraction in supersonic mixing flowfields. The original fluorescence ratio approach was introduced by Hartfield et al. for tests in a special closed-loop wind tunnel to eliminate the effects of thermodynamic property variations in compressible flowfields and to provide a quantitative means of mole-fraction measurement. However, they implicitly assumed that the tracer molecules were seeded at the same fraction in both main and secondary flows. In the present study, we proposed generalizing the Hartfield method by considering differences in the tracer seeding rates. We examined the generalized method in a mixing flowfield formed by sonic transverse injection into a Mach 1.8 supersonic air stream. The injectant molefraction distribution obtained from PLIF data processed by our new approach showed better agreement with the gas chromatograph than one based on the Hartfield method.

  • PDF

LNGC용 Power Generator 모델링 및 시뮬레이션 (Power Generator Modeling and Simulation for LNGC)

  • 황준태;홍석윤;권현웅;이광국;송지훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.297-299
    • /
    • 2016
  • 본 논문에서는 MATLAB/SIMULINK 기반의 LNG 선박용 Power Generator 모델링을 수행하고 시뮬레이션 결과 모니터링이 가능한 인터페이스를 구현하였다. Power Generator의 주요 구성은 기계적 동력을 공급하는 엔진부(Diesel 엔진, Turbine 엔진)와 기계적 동력을 받아 전력을 생산 및 공급을 하는 동기발전기가 있다. 또한, 단일 용량을 초과하는 전체 부하를 공유하기 위해 병렬 연결된 Generator의 Load Sharing과 선박의 가상 부하에 따른 시뮬레이션을 수행하였다. 시뮬레이션 결과와 가상 부하에 따른 예상 결과의 비교를 통해 Power Generator 모델링의 신뢰성을 검증하였다.

  • PDF

부하추종 냉각수 시스템의 온도 제어를 위한 유전알고리즘 기반 비선형 PID 제어기 설계 (Genetic algorithm-based design of a nonlinear PID controller for the temperature control of load-following coolant systems)

  • 이유수;황순규;안종갑
    • 수산해양기술연구
    • /
    • 제58권4호
    • /
    • pp.359-366
    • /
    • 2022
  • In this study, the load fluctuation of the main engine is considered to be a disturbance for the jacket coolant temperature control system of the low-speed two-stroke main diesel engine on the ships. A nonlinear PID temperature control system with satisfactory disturbance rejection performance was designed by rapidly transmitting the load change value to the controller for following the reference set value. The feed-forwarded load fluctuation is considered the set points of the dual loop control system to be changed. Real-coded genetic algorithms were used as an optimization tool to tune the gains for the nonlinear PID controller. ITAE was used as an evaluation function for optimization. For the evaluation function, the engine jacket coolant outlet temperature was considered. As a result of simulating the proposed cascade nonlinear PID control system, it was confirmed that the disturbance caused by the load fluctuation was eliminated with satisfactory performance and that the changed set value was followed.

RF 마그네트론 스퍼터링법으로 증착된 Multiferroic BiFeO3 박막의 미세구조 및 자기적 특성 (Microstructures and Magnetic Properties of Multiferroic BiFeO3 Thin Films Deposited by RF Magnetron Sputtering Method)

  • 송종한;남중희;강대식;조정호;김병익;최덕균;전명표
    • 한국자기학회지
    • /
    • 제20권6호
    • /
    • pp.222-227
    • /
    • 2010
  • RF 마그네트론 스퍼터링법을 이용하여 Pt/Ti/$SiO_2$/Si(100) 기판위에 $BiFeO_3$ 박막을 증착하였고, 스퍼터링 공정에서 산소량이 $BiFeO_3$ 박막에 미치는 영향을 조사하였다. $BiFeO_3$ 박막은 XRD 회절패턴의 결과를 통하여 소량의 불순물상이 존재하는 페로브스카이트 구조로 결정화되었다. $O_2$ 가스의 유량은 박막의 미세구조 및 자기적 특성에 많은 영향을 끼친다. $O_2$ 가스의 유량이 증가함에 따라 박막의 표면 거칠기 및 grain size가 증가하였다. $BiFeO_3$ 박막은 상온에서 약자성적인 거동을 보였으며, PFM 측정을 통하여 박막의 미세구조와 압전계수와의 상관관계를 조사하였다.