• 제목/요약/키워드: Gas introduction

검색결과 303건 처리시간 0.026초

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제23권E2호
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

디젤 예혼합 압축착화 엔진에서 EGR 및 수소농후가스의 영향 (The Effects of EGR and Hydrogen Enriched Gas on Diesel HCCI Engine)

  • 박철웅;조준호;오승묵
    • 한국자동차공학회논문집
    • /
    • 제19권1호
    • /
    • pp.1-8
    • /
    • 2011
  • In recent years, there has been an interest in early-injection diesel engines as it has the potential of achieving a more homogeneous and leaner mixture close to TDC compared to standard diesel engine. The more homogeneous mixture may result in reduced NOx and soot emissions and higher efficiency in homogeneous charge compression ignition engines. While earlier studies have shown that a reduction in NOx emissions from HCCI engine is possible, there are some significant problems including the control of ignition timing and combustion rate. In order to investigate the effect of EGR and hydrogen enriched gas on combustion characteristics and emissions, an experiments with single cylinder CRDi engine were carried out concerning the formation of various premixed charge, which can achieved by early injection, EGR and hydrogen enriched gas. EGR was not effective to further reduce NOx and PM emissions. It was found that NOx emissions were decreased with an introduction of hydrogen enriched gas and an adequate diesel fuel amount.

Gas Dynamical Evolution of Central Regions of Barred Galaxies

  • 서우영;김웅태
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.55.1-55.1
    • /
    • 2011
  • We investigate dynamical evolution of gas in barred galaxies using a high-resolution, grid-based hydrodynamic simulations on two-dimensional cylindrical geometry. Non-axisymmetric gravitational potential of the bar is represented by the Ferrers ellipsoids independent of time. Previous studies on this subject used either particle approaches or treated the bar potential in an incorrect way. The gaseous medium is assumed to be infinitesimally-thin, isothermal, unmagnetized, and initially uniform. To study the effects of various environments on the gas evolution, we vary the gas sound speed as well as the mass of a SMBH located at the center of a galaxy. An introduction of the bar potential produces bar substructure including a pair of dust lane shocks, a nuclear ring, and nuclear spirals. The sound speed affects the position and strength of the bar substructure significantly. As the sound speed increases, the dust lane shocks tend to move closer to the bar major axis, resulting in a smaller-size nuclear ring at the galactocentric radius of about 1 kpc. Nuclear spirals that develop inside a nuclear ring can persist only when either sound speed is low or in the presence of a SMBH; they would otherwise be destroyed by the ring material with eccentric orbits. The mass inflow rates of gas toward the galactic center is also found to be proportional to the sound speed. We find that the sound speed should be 15 km/s or larger if the mass inflow rate is to explain nuclear activities in Seyfert galaxies.

  • PDF

Physicochemical Characterization of Mo Films at Various Oxygen Ratio

  • 빈준형;박주연;강용철
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.88-88
    • /
    • 2010
  • We synthesized molybdenum thin films deposited by RF magnetron sputtering and physicochemical analysis was performed. The physical and chemical properties of these films were examined with X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The obtained film at the oxygen ratio of 0% showed crystallinity of cubic Mo(110) phase. After the oxygen ratio increased more than 5% in the sputter gas, the molybdenum films were formed as an amorphous phase. The thickness of the Mo thin film was drastically decreased from 1000 nm to ca 70 nm after introduction of oxygen in the sputter gas confirmed by spectroscopic ellipsometer (SE) and scanning electron spectroscopy (SEM). The calculated band gap of the film deduced from SE data increased from 3.17 to 3.63 eV by addition of oxygen in the sputter gas. The roughness of the Mo film was examined with atomic force microscopy (AFM) and it was dramatically decreased by introducing of oxygen during sputtering. XPS results revealed that the ratio of metallic Mo species in the film decreased by the contents of Mo(VI) species increased at the ratio of oxygen increased in the sputter gas and fully oxidized at low content of oxygen in the sputter gas.

  • PDF

철도노선의 환경부하 평가를 위한 LCA 도입방안 연구 (A study on the Introduction of Life Cycle Assessment (LCA) for Railroad lines)

  • 김용기;이철규;이지하;이재영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.168-172
    • /
    • 2008
  • Due to sustainable development, international environmental regulations have been reinforced continuously. As Kyoto protocol has been effective in 2005, the reduction of $CO_2$ emission is a global urgent problem. Especially, Kyoto protocol related to energy consumption affects to national production system seriously. In 2013, Korea greenhouse gas reduction obligations as the country is almost certain measures to respond steps to prepare a plan to reduce $CO_2$ emission of industry. Also, the Environmental impacts with a fundamental review for railroad lines do not yet come true. Therefore, the introduction of LCA will be required to decrease environmental impacts released from railroad lines in the future

  • PDF

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • 신재생에너지
    • /
    • 제2권3호
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

희박 예혼합 가스터빈 연소기에서의 화염 전달 함수 소개 (Introduction to Flame Transfer Function in Lean Premixed Gas Turbine Combustor)

  • 김대식
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.975-979
    • /
    • 2011
  • 희박 예혼합 가스터빈 연소기는 강화되는 NOx 배출가스 규제를 만족시키기 위한 가장 현실적인 방법으로 인식되고 있다. 그러나 이러한 희박 예혼합 연소기에서는 열발생파와 시스템 내부의 압력파 사이의 상호 피드백 관계에 의한 연소 불안정 현상으로 인하여 그 적용이 제한되거나, 이를 회피하기 위한 기술의 적용으로 인하여 설계 비용의 상승이 불가피하다. 본 논문에서는 연소 불안정 현상이 발생하는 기본 메커니즘을 소개하고, 연소 불안정 원인 규명의 일환으로 최근 활발히 연구되고 있는 화염전달 함수 측정이 실험적으로 규명되었고, 주요 측정 결과가 소개되었다.

외면부식 직접평가법 개발 및 국내 도입 연구 (The Development and Introduction of External Corrosion Direct Assessment Measures for Urban Gas Pipelines)

  • 류영돈;이진한;윤영기;임호석
    • 한국가스학회지
    • /
    • 제18권5호
    • /
    • pp.12-19
    • /
    • 2014
  • 매설배관의 부식위험성을 최소화하고 음극방식의 효율극대화를 위해 다양한 비굴착 간접검사기법들이 수십년 전부터 이용되고 있으며, 미국에서는 굴착을 통한 매설배관 외면부식 직접평가법을 CFR 코드에서 규정하고 있다. 국내의 경우에는 도시가스사업법 관련 4개의 기준(KGS Code)에서 배관의 손상여부를 측정할 수 있는 장비를 이용하여 배관의 상태를 점검, 측정하고 이상부위에 대하여 누출검사를 한 경우 매설배관의 기밀시험을 한 것으로 보고 있을 뿐 배관외면부식 직접평가에 대한 규정은 없다. 본 논문에서는 미국, 영국 등 국외의 매설배관 건전성 관리 기준 및 방법을 조사하고, 국내의 매설배관 방식관리 실태 및 피복손상탐지 장치 이용실태 등을 조사한 후 국내 실정에 맞는 매설배관 외면부식 직접평가법을 제시하였다. 본 논문에서 제시한 매설배관 외면부식 직접 평가법은 국내에서 중압배관의 정밀안전진단 제도를 도입하는데 기초 자료로 활용되었다.

동해 가스하이드레이트 탐사에 적용한 지구물리탐사 방법 (Geophysical Methods applied for Gas Hydrate Exploration in the East Sea)

  • 이호영;박근필;유동근;구남형;김원식;김병엽;강동효;김한준
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 특별 심포지엄 논문집
    • /
    • pp.53-62
    • /
    • 2007
  • Preliminary gas hydrate surveys were carried out From 2000 to 2004 in the East Sea. Research results showed the geophysical evidence of gas hydrate existence. In 2005, Gas Hydrate R&D Organization was established and 10 year gas hydrate development program was initiated. In the $1^{st}$ stage of the program from 2005 to 2007, 6,600 L-km 2-D seismic survey was conducted in the $1^{st}$ year 2005, and $400\;km^2$ 3D survey was conducted in the $2^{nd}$ year 2006. Acquired seismic data were processed and seismic section and 3D cube were produced. By geophysical interpretation and velocity analysis, prospective areas were mapped and candidate drilling sites were recommended. For the precise interpretation, velocity was analyzed using AVO method, and BSR signal was analyzed using deconvolution method. For the prospective area, OBS and high-resolution seismic surveys were conducted. This presentation shows the introduction and examples of the research results of the geophysical methods applied for the gas hydrate exploration in the East Sea.

  • PDF

산업단지 고압매설배관 안전관리 고찰 (A Study on the Safety Management of High Pressure Underground Pipeline in Industrial estate)

  • 최현웅;정세광;김진준
    • 한국가스학회지
    • /
    • 제21권6호
    • /
    • pp.30-38
    • /
    • 2017
  • 1960년대에 설립된 울산 및 여수 산업단지 고압가스매설배관은 누출 시 피해가 큰 독성가스는 물론 도시가스보다 무겁고 연소범위가 낮은 가연성가스가 그물망처럼 매설사용 중에 있다. 특히, 산업단지 배관의 경우 20년 이상 노후된 배관이 과반이상으로 점유하고 있다. 이와 같이 산업단지 배관은 상주시공감리제도 도입이전에 매설설치 되었으나, 도시가스 매설배관과 달리 법적 의무 없이 자율적으로 배관관리를 하고 있다. 본 연구에서는 산업단지 고압매설배관과 도시가스 매설배관의 안전관리 실태현황, 법을 비교, 피해영향범위 분석 하고 이를 산업단지 고압매설배관의 배관점검모델 마련에 활용하여 산업단지 고압매설배관의 안전성 향상에 기여하고자 한다.