345kV 승압용 변전소의 뇌격에 의한 이상전압 해석 (Analysis of Transient Voltage by Lightning Stroke at 345kV Step-up Transformer)

  • 조만영;신호전;허재선;김재철
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.95-101
    • /
    • 2012
  • Typically, large scale power generation facilities are linked to 345kV transmission line through a step-up transformer. If the value of transient voltage by generating lightning stroke is large more than electric equipment's BIL, devices insulation is destroyed. LA(Lighting Arrester) is used as a main means of prevention. However, the installation of LA takes the constraints of installation place and expensive installation costs. Therefore, we need to carefully study whether installation of installation can be omitted and the most efficient place of installation. In this paper, we simulated the transient voltage detected by lightning stroke at each equipments in the 345kV transmission power grid by using EMTP-RV program.

공랭식 가스터빈 발전기의 운전중 부분방전 분석 (Analysis of On-Line Partial Discharge in Air-Coolded Gas Turbine Generator)

  • 이은춘;공태식;김재철;김희동
    • 조명전기설비학회논문지
    • /
    • 제28권7호
    • /
    • pp.41-47
    • /
    • 2014
  • The on-line partial discharge (PD) in stator windings of air-cooled gas turbine (GT) generator (119.2MVA, 13.8kV) is measured and analyzed in this paper. This generator was designed by global vacuum pressure impregnation (VPI). The generator failed two times at top bar (16T) of phase B in the stator slot. Six epoxy-mica capacitors were installed in three phases of GT generator. On-line PD test was performed on GT generator using turbine generator analyzer (TGA). TGA showed that the normalized quantity number (NQN) and the PD magnitude($Q_m$) were high in phase B. Internal discharges were generated in phases A, B and C. The trend analysis of NQN and $Q_m$ value are obtained in order to monitor the insulation condition in GT generator stator windings. Phases A and C were in good condition. But phase B had deteriorated significantly

온도변화에 따른 SF6/N2 혼합가스의 임펄스 절연파괴특성 (Impulse breakdown Characteristics in SF6/N2, Gas Mixtures with a Temperature Variation)

  • 이봉;이복희
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.79-86
    • /
    • 2008
  • 본 논문은 온도변화에 따른 $SF_6/N_2$ 혼합가스 중에서 높은 불평등전계의 임펄스절연파괴특성에 대한 실험적인 결과를 기술하였다. 온도범위는 $-25{\sim}25[^{\circ}C]$로 정하여 실험을 수행하였다. 임펄스 전구방전진전은 방전전류와 방전 광신호의 측정에 의해 분석되었다. 결과로써, 절연파괴전압은 정극성보다 부각성에서 온도변화에 대한 의존성이 강하게 나타났다. 온도가 상승함에 따라 부극성에서의 리더진전 스텝핑시간이 정극성보다 더 길게 나타났다. 본 연구 결과는 뇌서지에 대하여 우수한 성능을 가지는 가스절연선로의 설계에 유용한 정보가 될 것이다.

광섬유 Mach-Zehnder 간섭계를 이용한 부분방전 초음파 검출특성 (Detecting Characteristics of Ultrasonics Generated by Partial Discharge in Insulating Oil Using the Optical Fiber Mach-Zehnder Interferometer)

  • 이상훈;심승환;이광식;김달우
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.50-56
    • /
    • 2003
  • 본 논문에서는 유입변압기 진단을 목적으로 부분방전시 발생하는 여러 가지 물리적 화학적 현상중 초음파를 검출하기 위하여 광섬유 Mach-Zehnder 간섭계를 구성하였다. 구성된 광섬유 센서의 초음파 검출 평가 실험을 실시하고, 절연유 중에 배치한 침-평판전극에 교류 고전압을 인가하여 방전시 발생하는 초음파를 측정하고 퓨리에 변환 및 wavelet 변환을 이용한 데이터 분석 결과를 나타냈다.

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.

가스분석을 이용한 변압기의 이상진단 알고리즘 연구 (A Study of the Preventive Diagnostic Algorithm of Gas in Oil for Power Transformer)

  • 최인혁;권동진;정길조;유연표;선종호;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1903-1905
    • /
    • 2000
  • Power transformers have a tendency of ultra-high voltage capacity as power demand increases day after day KEPCO also will have plan to supply transmission power from 345KV to 765KV in the early of 2000. Therefore, the fault by insulation destruction gives rise to large area of power failure in huge capacity transformers. On-line predictive diagnostics is very important in power transformers because of economic loss and its spreading effect. This study presents the algorithm for transformer oil analysis used KEPCO code, IEC code, gas pattern method and Dornenburg & Roger Ratio method. We also describe the MMI display of expert system programmed by Element Expert Tool(Neuron Data Inc.).

  • PDF

절점망 해석프로그램을 이용한 해저터널 내 고전압 전력케이블에 의한 가스배관의 안전성 평가 연구 (A Study on the System Integrity of Gas Pipeline by High Voltage Power Line in Submarine Tunnel)

  • 배정효;하태현;이현구;김대경
    • 한국가스학회지
    • /
    • 제5권4호
    • /
    • pp.21-26
    • /
    • 2001
  • 최근 국내에서는 효율적인 공간활용을 위해 해저터널을 이용하여 전력을 공급하는 것이 시도되고 있으며, 해저터널 내에 에너지 공급 기간시설물(진력케이블, 가스배관, 송유관, 지역난방배관 등)들이 같이 포설될 수 있으면 공사비 절감의 효과는 엄청날 것이므로 관심도가 높아지고 있다. 최근, 국내에서도 해저터널 내에 가스배관과 전력선이 병행 시공되는 경우가 발생하여 가스배관에 대한 안전성에 대한 평가가 요구되고 있다. 따라서 본 논문에서는 해해저터널 내 고전압 전력케이블에 의한 가스배관의 교류부식, 가스배관의 코팅과 용융. 절연 플랜지, 전기방식용 정류기 등의 전기방식설비의 안정성에 대하여 검토함으로써, 최종적으로 가스배관의 안전성을 평가$\cdot$연구하였다.

  • PDF

OF 케이블 절연유의 특성 변화에 따른 경년열화진단 (The Aging Diagnosis of OF Cable Insulation Oil by Characteristic Change)

  • 윤구섭;정우성;김철운;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.35-40
    • /
    • 1997
  • As demand of electric power are growing and transmission line limited owing to enlargement of the downtown area The eonfidence of underground transmission cable which shows gradual growth are high. It is found whether insulating ability is good or not. In this paper, The exper iment result is shown that the fall of insulating ability and take preventive measure through the analysis of tans, water content, dielectric breakdown voltage, total acid number, volume resistivity , and gas in the oil in an accordance with the characteristic change of oil used very much for insulating oil of cable.

  • PDF

Environmently Friendly Glass Fiber and Nanoclay Reinforced Polyurethane Foam

  • Lee, Sung-Ho;Kim, Sung-Hee;Lim, Ho;Kim, Byung-Kyu
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.373-373
    • /
    • 2006
  • Rigid polyurethane foams(PUFs) are widely used in most areas of insulations such as storage tank and pipe line for transporting liquefied gas. Glass fiber and nanoclay are used for improvement in mechanical property and thermal insulation of rigid PUF at very low temperature(<$-150^{\circ}C$). These rigid PUFs have been characterized in terms of thermal, mechanical, dynamic mechanical properties and cell morphology. It was found that mechanical properties, thermal conductivity and dimensional stability of rigid PU foams were improved by glass fiber and nanoclay.

  • PDF

발전기 회전자 권선의 건전성 평가 (Assessment of Insulation Condition for Generator Rotor Windings)

  • 이영준;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.59-60
    • /
    • 2006
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line shorted-turn diagnosis system. The permanent flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.