Development of Fuel Conditioning System for 30 kW-class LFG Gasturbine Power Generation (30kW급 LFG 가스터빈 발전용 연료화 정제시스템 개발)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Gyu;Lee, Jung-Bin
    • New & Renewable Energy
    • /
    • v.6 no.1
    • /
    • pp.29-37
    • /
    • 2010
  • Biogas is a carbon neutral energy and consists of mostly methane and carbon dioxide, with smaller amounts of water vapor, and trace amounts of $H_2S$, Siloxane and other impurities. Hydrogen sulfide and Siloxane usually must be removed before the gas can be used for generation of electricity or heat. The goals of this project are to develope the Fuel conditioning system of Land Fill Gas for 30kW-Micro Gas Turbine co-generation system. The fuel conditioning system mainly consists of $H_2S$ removal system, Land Fill Gas compressor, Siloxane removal system and many filtering systems. The fuel requirement of 30kW MGT is at least 32% of $CH_4$, $H_2S$ (<30 ppm), Siloxane (<5ppb) and supply pressure (> 0.6 MPa) from LFG compressor. Main mechnical charateristics of Micro Gas Turbine system by using LFG have the specific performance; 1) high speed turbine speed (96,000 rpm) 2) very clean emmission NOx (<9 ppm) 3) high efficiency of energy conversion rate. This paper focuses on the development of design technology for LFG fuel conditioning system. The study also has the plan to replace the fuel of gas turbine and other distributed power systems. As the increase of Land Fill Gas (LFG), this system help to contribute to spread more New & Renewable Energy and the establishment of Renewable Portfolio Standards (RPS) for Korea.

Scenario Analysis of Natural Gas Demand for Electricity Generation in Korea (전력수급기본계획의 불확실성과 CO2 배출 목표를 고려한 발전용 천연가스 장기전망과 대책)

  • Park, Jong-Bae;Roh, Jea Hyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1503-1510
    • /
    • 2014
  • This study organizes scenarios on the power supply plans and electricity load forecasts considering their uncertainties and estimates natural gas quantity for electricity generation, total electricity supply cost and air pollutant emission of each scenario. Also the analysis is performed to check the properness of government's natural gas demand forecast and the possibility of achieving the government's CO2 emission target with the current plan and other scenarios. In result, no scenario satisfies the government's CO2 emission target and the natural gas demand could be doubled to the government's forecast. As under-forecast of natural gas demand has caused the increased natural gas procurement cost, it is required to consider uncertainties of power plant construction plan and electricity demand forecast in forecasting the natural gas demand. In addition, it is found that CO2 emission target could be achieved by enlarging natural gas use and demand-side management without big increase of total costs.

Testing a Commercial Gas Engine using Synthetic Biogas (합성 바이오가스를 이용한 상용 가스엔진 발전기의 구동 특성)

  • Shim, Jae-Hoon;Hong, Seong-Gu;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.592-597
    • /
    • 2005
  • Biogas is widely accepted as one of renewable energy. Raw biogas can be used in internal combustion engines either spark ignition or diesel engines. Since the gas has relatively low calorific values, engine power also is lower than rated power values. Modified engines or biogas-specific engines have been utilized in order to increase efficiency. Recently, gas engine/generators are provided for various purposes. They are mostly for LPG or natural gas. When biogas is fueled to the gas engines, de-rating is inevitable due to its lower calorific values. Meanwhile, massively produced commercial gas engines are more competitive in terms of initial investment for engines, compared to biogas-specific engines. Then, the characteristics of the commercial engine and power generation should be understood for better operation. A 5kW gas engine/generator(natural gas) was tested for determining an allowable maximum concentration of $CO_2$ in synthetic biogas, with respect to engine stating, power generation. Experimental results indicated that about 65% of methane concentration is required to start the gas engine. At this condition, the power generated was about 3 kW. It is about 60% of the nominal power, which is similar to the ratio of calorific values.

  • PDF

Potential of gas generation and natural gas hydrate formation in the near seafloor sediment of the Ulleung Basin (울릉분지 천부 퇴적층에서의 가스 생성과 천연가스 하이드레이트 형성 잠재력)

  • Ryu, Byong-Jae;Lee, Young-Joo;Kim, Ji-Hoon;Kim, Il-Soo;Park, Myong-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.419-423
    • /
    • 2006
  • Basic studies on natural gas hydrates in the East Sea were been carried out by the Korea Institute of Geoscience and Mineral Resources (KIGAM) from 2000 to 2004 involving 2D multichannel seismic lines and piston coring. 27 piston cores recovered from the deed-water Ulleung Basin of the East Sea were analyzed in this study. In piston cores cracks generally developed parallel to bedding suggest significant gas content. The core analyses showed high total organic carbon (TOC) content, sedimentation rate and heat flow of sediments. The cores recovered from the southern study area show also high residual hydrocarbon gas concentrations for the formation of natural gas hydrates. This study indicates that there is the potential for the generation of biogenic gas and the formation of natural gas hydrates in the near seafloor sediments of the study area.

  • PDF

Life cycle analysis on correlation relationship between GHG emission and cost of electricity generation system for energy resources (전과정을 고려한 에너지 자원별 전력생산의 온실가스 배출량과 비용의 상관관계 분석)

  • Kim, Heetae;Ahn, Tae Kyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.136.2-136.2
    • /
    • 2011
  • In this work, we analyzed correlations between life-cycle greenhouse gas (GHG) emissions and life-cycle cost of energy resources. Energy resources studied in this paper include coal, natural gas, nuclear power, hydropower, geothermal energy, wind power, solar thermal energy, and solar photovoltaic energy, and all of them are used to generate electricity. We calculated the mean values, ranges of maximum minus minimum values, and ranges of 90% confidence interval of life-cycle GHG emissions and life-cycle cost of each energy resource. Based on the values, we plotted them in two dimensional graphs to analyze a relationship and characteristics between GHG emissions and cost. Besides, to analyze the technical maturity, the GHG emissions and the range of minimum and maximum values were compared to each other. For the electric generation, energy resources are largely inverse proportional to the GHG emission and the corresponding cost.

  • PDF

A Study on the Model of Competitive Electricity Market Considering Emission Trading (온실가스 배출권 거래제도를 고려한 경쟁적 전력시장 모형 연구)

  • Kim, Sang-Hoon;Lee, Kwang-Ho;Kim, Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1496-1503
    • /
    • 2009
  • The United Nations Framework Convention on Climate Change (UNFCCC) is an international environmental treaty to stabilize greenhouse gas concentrations in the atmosphere. In order to fulfil the commitments of the countries in an economically efficient way, the UNFCCC adapted the emission trading scheme in the Kyoto Protocol. If the UNFCCC's scheme is enforced in the country, considerable changes in electric power industry are expected due to the imposed greenhouse gas emission reduction. This paper proposes a game theoretic model of the case when generation companies participate in both competitive electricity market and emission market simultaneously. The model is designed such that generation companies select strategically between power quantity and greenhouse gas reduction to maximize their profits in both markets. Demand function and Environmental Welfare of emission trading market is proposed in this model. From the simulation results using the proposed model the impact of the emission trading on generation companies seems very severe in case that the emission prices are significantly high.

Generation and fluorescence measurement of HF* molecules excited by combustion of fluorine and hydrogen (불소-수소 연소 열을 이용한 들뜬 상태 HF* 분자의 생산 및 형광 측정)

  • 최윤동;권성옥;김택숙;김성훈;김응호;김철중
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.3
    • /
    • pp.153-157
    • /
    • 2001
  • Operation conditions for the generation of an HF laser driven by fluorine-hydrogen combustion were discussed by mc:asuring the intensities of excited HF* molecules. Optimum injection quantities of fluorine gas for the generation of fluorine atoms was two times the injection mole number of hydrogen fuel. Slit nozzles with two dimensional configuration were used for the production of excited HF* molecules. When the injection mole number of secondary hydrogen gas is 1.3 times the injection mole number of fluorine gas, the fluorescence intensities of excited HF* molecules show maximum values. alues.

  • PDF

Performance Test of MGT Combined Heat & Power System (마이크로 가스터빈 열병합 발전시스템 성능평가)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

Analysis of Axial Compressor Design Characteristics in Large Class Gas Turbine for Power Generation (발전용 대형 가스터빈 축류압축기 설계 특성 분석)

  • Lee, Sung-Ryong;Song, Jae-Wook;Kim, Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.1
    • /
    • pp.64-69
    • /
    • 2012
  • Currently axial flow compressor is used primarily in a large power generation gas turbine. In this paper,the main factors to be considered when designing a axial flow compressor were compared to those of a small power generation gas turbine(DGT-5). The main design parameters was examined in the aspect ratio, solidity, as well as reaction, diffusion factor, incidence angle, etc. The results in case of a small compressor are showed a regular pattern but there were not found any specific design patterns for a large class compressor.