• 제목/요약/키워드: Gas generation

검색결과 1,702건 처리시간 0.028초

산소분리기술을 사용한 연료전지/순산소연소 발전시스템 해석 (Analysis of Solid Oxide Fuel Cell/Oxy-fuel Combustion Power Generation System Using Oxygen Separation Technology)

  • 박성구;김동섭;손정락;이영덕
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.51-54
    • /
    • 2008
  • This study aims to devise and analyze a power generation system combining the solid oxide fuel cell and oxy-fuel combustion technology. The fuel cell operates at an elevated pressure, a constituting a SOFC/gas turbine hybrid system. Oxygen is extracted from the high pressure cathode exit gas using ion transport membrane technology and supplied to the oxy-fuel power system. The entire system generates much more power than the fuel cell only system due to increased fuel cell voltage and power addition from oxy-fuel system. More than one third of the power comes out of the oxy-fuel system. The system efficiency is also higher than that of the fuel cell only system. Recovering most of the generated carbon dioxide is major advantage of the system.

  • PDF

A Study on the Applicability of MELCOR to Molten Core-Concrete Interaction Under Severe Accidents

  • Kim, Ju-Youl;Chung, Chang-Hyun;Lee, Byung-Chul
    • Nuclear Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.425-432
    • /
    • 2000
  • It has been an essential part for the safety assessment of nuclear power plants to understand various phenomena associated with the molten core-concrete interaction(MCCI) under severe accidents. In this study, the severe accident analysis code MELCOR was used to simulate the MCCI experiments such as SWISS and SURC test series which had been performed in Sandia National Laboratories(SNL). The calculation results were compared with corresponding experimental data such as melt temperature, concrete ablation distance, gas generation rate, and aerosol release rate. Good agreements were observed between MELCOR calculation and experimental data. The melt pool was sustained within the range of high temperature and the concrete ablation occurred continuously. The gas generation and aerosol release were under the influence of melt temperature and overlying water pool, respectively.

  • PDF

발전용 가스터빈 연소기의 천연가스 연소유동 해석 (Natural Gas Combustion Analysis in Power Generation Gas Turbine)

  • 김태호;최정열
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.156-161
    • /
    • 2005
  • Two and Three dimensional numerical simulations have been carried out to understand the combustion characteristics of LNG-fueled gas turbine combustor for power generation. Focus of the study was given to the influences of different fuel composition of imported and domestic natural gases with the flow conditions selected from the gas turbine operation data. Reacting flow characteristics of the swirl stabilized natural gas combustor were understood from the comparison of the two-dimensional and three-dimensional results. The thermal influences of different natural gases were very small and the fuel composition and flow rate were considered to be tuned well.

  • PDF

열병합발적용 Dual Fuel Engine의 질소산화물 배출저감에 관한 연구 (A Study on the Reduction of $NO_x$ Emission from Dual Fuel Engine for Co-generation System)

  • 정일래;김용술;심용식
    • 한국대기환경학회지
    • /
    • 제7권1호
    • /
    • pp.31-40
    • /
    • 1991
  • This study shows the correlation between $NO_x$ emission in the exhaust gas and various operation factors of dual fuel engine for Co-generation system. General tendency was shown that the thermal efficiency was lowered by the change of operation factors. However these were not confirmed on this experiment. Increasing T4 temperature (exhaust gas temperature at turbo-charger inlet) reduces $NO_x$ emission rate. The higher T4 temperature requires lower excess air as the excess air ratio is controlled by T4 temperature on gas mode operation. Another tendency was that $NO_x$ emission rate is reduced in case of increasing boost air temperature, quantity of pilot oil or bypassing flue gas through the exhaust gas boiler. The diameter of the fuel injection nozzle was changed smaller than design value and the injection timing was readjusted. Thus $NO_x$ emission rate could be reduced as retarding injection timing and changing hole diameter of fuel injection nozzle, however maxium engine out-put was decreased by changing fuel nozzle on the diesel mode operation.

  • PDF

발전용 가스터빈 Rotor 정지조건별 최적 Turning 운전시간 고찰: 501기종 현장실험 중심으로 (A Study on Optimal Turning Operation Time for Rotor Stop Condition in Gas Turbine: Based on Field Test of W501 Machines)

  • 유원주;이창열
    • 대한안전경영과학회지
    • /
    • 제25권3호
    • /
    • pp.1-7
    • /
    • 2023
  • As the capacity of renewable power generation facilities rapidly increases, the variability of electric power system and gas turbine power generation is also increasing. Therefore, problems may occur that require urgent repair while the gas turbine rotor is stopped. When the gas turbine rotor turning is stopped and then restarted, if the turning period is not appropriate, severe vibration may occur due to rotor bending. As a result of the experiment, it was confirmed that normal operation is possible when the gap data measured at the start of rotor turning after maintenance work is similar to the existing value. And the vibration value at the start of rotor turning was lower as the rotor temperature was lower or the stop period was shorter.

기체분리용 고분자 멤브레인의 최근 개발 동향 (A Numerical Analysis of Direct Contact Membrane Distillation for Hollow Fiber Membrane)

  • 김태헌;정종채;박종만;우창화
    • 멤브레인
    • /
    • 제20권4호
    • /
    • pp.267-277
    • /
    • 2010
  • 가스분리막을 이용한 분리공정은 기존의 분리공정을 대체할 공정으로서 수십 년간 발전이 되어 왔다. 특히 분리막 공정은 가스분리에 있어서 기존공정에 비해서 에너지 소모가 적고 설치에 필요한 공간이 간소하며, 스케일업이 간단한 장점이 있다. 최근에는 기체분리막 공정은 질소발생장치, 수소발생장치, 막제습기, 선박이나 항공기용 불활성기체충진장치, 천연가스 정제, 바이오가스 정제, 연료전지분야에서 널리 사용이 되고 있으며, 향후에는 이산화탄소의 분리에도 강력한 대체공정으로 사용이 될 수 있다. 이러한 가스분리막 공정을 좀 더 널리 보급하기 위해서는 로베슨 플롯의 한계를 넘어설 수 있는 새로운 소재의 개발이 절실하며, 이러한 한계를 돌파하기 위하여 많은 연구자와 회사들이 카도그룹이나 스피로 구조를 가지는 고분자나 PIMs 같은 소재의 개발에 박차를 가하고 있다.

화력발전의 신재생에너지 전환에 따른 경제적 파급효과 분석 (An Analysis of the Economic Effects of the New and Renewable Energy Transformation of Thermal Power Generation)

  • 임상수
    • 자원ㆍ환경경제연구
    • /
    • 제32권2호
    • /
    • pp.127-147
    • /
    • 2023
  • 본 연구는 정부의 탄소중립 정책 중 하나인 화력발전을 신재생에너지로 대체하는 경우 에 대한 경제적 파급효과를 분석하는 것을 목적으로 한다. 이러한 분석을 위해 화력발전을 신재생에너지로 100% 대체하는 경우를 시나리오 A로 설정하고, 60%로 대체하는 경우를 시나리오 B로 설정한다. 또한 이렇게 화력발전을 신재생에너지로 대체할 때 비용이 발생하게 되는데 현행과 동일한 비용인 경우를 시나리오 1, 현행보다 비용이 120% 증가한 경우를 시나리오 2로 설정한다. 따라서 화력발전을 신재생에너지로 전환할 때 시나리오는 크게 이와 같이 4가지 경우로 정리된다. 화력발전을 신재생에너지로 전환하는 경우, 화력발전의 생산유발계수는 시나리오와 관계없이 현행 수준보다 감소하는 것으로 나타났다. 그러나 화력발전을 신재생에너지로 100% 전환하는 경우 부가가치유발계수와 온실가스배출량 유발계수는 현행 수준보다 감소한 반면 화력발전을 신재생에너지로 60% 대체하는 경우 부가가치유발계수와 온실가스배출량 유발계수는 현행 수준보다 증가했다. 또한 대부분의 업종의 온실가스배출량 유발계수는 감소하는 것으로 나타난 반면 생산유발계수와 부가가치유발계수는 증가하는 것으로 나타났다. 정부 정책의 목적은 화력발전을 신재생에너지로 전환시켜 온실가스배출량을 축소시키는 것이기 때문에 시나리오 화력발전을 신재생에너지로 100% 전환하는 경우가 더 적합한 것으로 보인다. 다만, 이로 인해 일부 업종의 생산유발계수와 부가가치유발계수가 감소하는 부작용이 발생하므로 이를 해결하기 위한 정부의 지원 정책이 필요하다.

매립가스 자원화를 위한 가스엔진 발전의 수익성에 관한 연구 (A Study on Profitability of Power Plant for Landfill Gas)

  • 김오우;이정일
    • 한국산학경영학회:학술대회논문집
    • /
    • 한국산학경영학회 2006년도 춘계학술발표대회 발표논문집
    • /
    • pp.147-170
    • /
    • 2006
  • 재생에너지로서의 매립가스는 매립된 폐기물의 분해과정에서 생성되는 부산물로서 악취와 환경오염을 유발하는 유해한 가스로 여겨져 왔으나, 최근 들어 매립가스를 대체에너지 자원으로 이용하려는 추세가 나타나고 있음은 매우 고무적인 현상이라 하겠다. 발열량이 $5,000kcal/m^3$에 달하는 매립가스의 특성은 에너지원으로써의 활용가치가 탁월한데다 지구온난화의 주범으로 떠오르면서 그 회수 필요성이 더욱 강조되고 있는 실정이다. 현재 우리나라의 매립가스자원화 사업은 가스엔진을 이용한 전력생산이 대부분을 차지차고 있으며, 부분적으로 중질가스와 고질가스의 활용에도 관심을 보이고 있다. 가스발전기의 가동률과 전력단가의 변동을 고려하여 매립가스의 경제성을 분석해본 결과, 초기 투자비 회수와 지속적인 수익성 확보를 위해서는 최소한 10년 이상의 발전사업 운영 및 전력판매 단가의 현실화가 요구되고 있다.

  • PDF

배열 이용도를 고려한 가스터빈 발전시스템의 부분부하 성능 비교분석 (Comparative Part Load Performance Analysis of Gas Turbine Power Generation Systems Considering Exhaust Heat Utilization)

  • 김동섭
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.290-297
    • /
    • 2002
  • This paper presents analysis results for the effect of power control strategies on the part load performance of gas turbine based power generation systems utilizing exhaust heat of the gas turbine such as cumbined cycle power plants and regenerative gas turbines. For the combined cycle, part load efficiency variations were compared among different single shaft gas turbines representing various technology levels. Power control strategies considered were fuel only control and IGV control. It has been observed that gas turbines with higher design performances exhibit superior part load performances. Improvement of part load efficiency by adopting air flow modulation was analyzed and it is concluded that since the average combined cycle performance is affected by the range of IGV control as well as its temperature control principle, a control strategy appropriate for the load characteristics of the individual plant should be adopted. For the regenerative gas turbine, it is likewise concluded that maintaining exhaust temperature as high as possible by air flow rate modulation is required to increase part load efficiency.

  • PDF