• Title/Summary/Keyword: Gas exchange

Search Result 648, Processing Time 0.032 seconds

A study on the Valve Overlap Period and Valve Lift on the SI Engine Characteristics (밸브오버랩기관과 양정변화가 엔진특성에 미치는 영향에 관한 연구)

  • 황재원;김응혁;황화자;한정희;채재우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.28-36
    • /
    • 2001
  • In this study, a zero-dimensional two zone model is developed to investigate the effects of valve overlap period and valve lift on combustion and gas exchange process in SI engine. The simulation results show that the predicted data has good agreements with experimental ones. The useful information of combustion and gas exchange process such as residual gas fraction, cylinder pressure, mass flow rate and volumetric efficiency can be obtained and the effects of engine variables on combustion processes and performances can be evaluated.

  • PDF

Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct (열회수장치에 의한 열교환 성능 분석(농업시설))

  • 서원명;강종국;윤용철;김정섭
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.333-339
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas funnel connected to combustion chamber of greenhouse heating system. The experiment heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas funnel, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amount by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air pipes and exhaust air passages crossing the pipes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through funnels.

  • PDF

Stack Performances of Proton Exchange Membrane Fuel Cell

  • Kho, Young-Tai;Cho, Won-Ihl;Park, Yong-Woo-
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.14-16
    • /
    • 1994
  • The development of proton exchange membrane fuel cells(PEMFCs) with high energy efficiencies and high power densities is gaining momentum because their performance characteristics are attractive for terrestrial(power sources for electrical vehicles, stand-by power), space and underwater application[1]. Fuel cells are capable of running on non-petroleum fuels such as methanol, natural gas or hydrogen and also have major impact on improving air quality. They virtually eliminate particulates, NO$_{x}$, SO$_{x}$, and significant reduce hydrocarbons and carbon monoxide. Especially, fuel cell-battery hybrid power sources appear to be well suited to overcome both the so-called battery problem(low energy density) and the fuel cell problem(low power density)[2].[2].

  • PDF

An Experimental Study of Ventilation Effectiveness in Mechanical Ventilation systems using a Tracer Gas Method

  • Lee, Jae keun;Kang, Tae-Wook;Lee, Kam-Gyu;Cho, Min-Chul;Shin, Jin-Hyuk;Kim, Seong-Chan;Koo, Jeong-Hwan;Lee, Jong ho
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.11
    • /
    • pp.1286-1295
    • /
    • 2000
  • The ventilation effectiveness is evaluated as a function of air exchange rate and supply / extract locations in a simplified model chamber using a tracer gas technique of CO$_2$ gas injected into a supply duct. Ventilation systems consist of supply and extract fans, a CO$_2$gas generator, a CO$_2$gas analyzer and a test chamber. The ventilation effectiveness is evaluated using a step-down method based on ASTM Standard E741-83. The room mean age of the model chamber is decreased with increasing air exchange rate fanged from 6to 10 air changes per hour. The ventilation effectiveness of the mechanical inlet/natural extract system is better than that of the mechanical extract system.

  • PDF

The Impact of Social Media on Firm Value: A Case Study of Oil and Gas Firms in Indonesia

  • NUR D.P., Emrinaldi
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.3
    • /
    • pp.987-996
    • /
    • 2021
  • The development of Internet technology can affect firm value through the use of social media by business people. Nowadays, social media affect businesses of all sizes in several different ways. Despite the various benefits obtained by using social media, research at the organizational level and its impact on business performance have not grown as fast as desired. This research aims to examine the effect of social media on oil and gas firms' value. The research sample consists of 9 oil and gas firms listed on the Indonesian Stock Exchange 2013-2018. Social media proxies are firms' social media, other social media mentions, and social media sentiment. Firm value is measured by the market value to assets ratio. Data analysis uses a random-effect regression test. Based on the analysis, the social media account of a firm has a positive effect on firm value. It indicates that social media give advantages for oil and gas firms to give a signal of business prospect, make use of opportunities related to industry alliances, recruit employees globally, and c. On the other hand, the positive sentiment on social media has no effect on oil and gas firms' value.

Development of Novel Techniques for Determining the Oxygen Tracer Diffusion Coefficients in Oxides II - Measurements of the Depth Profiles of $^{18}O$ Concentration in the solid Samples by Raman Spectroscopy (산화물에서의 산소추적자확산계수를 결정하는 새로운 방법의 개발 II - 라만분광법에 의한 고체시료 중의 시간에 따른 $^{18}O$ 농도변화 측정 -)

  • 김병국;마하구찌히로오;박순자
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.12
    • /
    • pp.1459-1466
    • /
    • 1994
  • A novel technique for determining the oxygen tracer diffusion coefficients in oxides was developed. After the 16O-18O solid-gas exchange reactions between 16O in the oxides and 18O in the ambient gas, Raman spectra of the cross sections of oxide samples were measured in a spatial resolution of 5 ${\mu}{\textrm}{m}$. From thus obtained Raman spectra, depth profiles of 18O concentration in the oxide samples were calculated. The oxygen tracer diffusion coefficients and the surface exchange coefficients were determined under the assumptions that samples are semi-infinite slab and that the surface exchange reactionsare not negligible. The oxygen tracer diffusion coefficient of 2.8 mol% Y2O3-containing tetragonal ZrO2 polycrystals, 8 mol% Y2O3-containing ZrO2 polycrystals, and 10 mol% Y2O3-containing cubic ZrO2 single crystals (along the a axis) are as follows.

  • PDF

Theoretical Studies Gas Phase Reaction of Alkoxide-Exchange at Silicon and Carbon Centers$^\dag$

  • Lee, Ik-Choon;Yang, Ki-Yull;Park, Byong-Seo;Lee, Kae-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.3
    • /
    • pp.231-235
    • /
    • 1986
  • MNDO and ab initio calculations for gas phase reactions of alkoxide-exchange at silicon and carbon centers have been performed. Results show that MNDO values of ${\Delta}$E's of these reactions closely parallel those of the STO-3G method. The alkoxide-exchange at silicon is shown to be facile due to the formation of stable five-coordinate intermediate while the reaction at carbon is predicted to proceed with high barrier; the difference in this substitution behavior between carbon and silicon is shown to be due to an easy valence shell expansion of silicon in accommodating an extra bond in the formation of stable five-coordinate intermediates.

Study on Transient Response of a Unit Proton Exchange Membrane Fuel Cell with an Aged Gas Diffusion Layer (내구성능저하된 기체확산층이 고분자전해질 연료전지의 과도응답성능에 미치는 영향 연구)

  • Cho, Junhyun;Ha, Tahun;Park, Jaeman;Oh, Hwanyeong;Min, Kyoungdoug;Jyoung, Jy-Young;Lee, Eunsook
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.76.2-76.2
    • /
    • 2010
  • The gas diffusion layer is the key component of the proton exchange membrane fuel cell because it directly affect to the mass transport mechanism and dynamic behavior of the cell. In this study, the effects of GDL aging on the transient response of the PEM fuel cell is systematically investigated using current step transient response analysis under different stoichiometric ratios and humidity conditions. With GDLs aged by the accelerated stress test, the effects of hydrophobicity and structural changes due to carbon loss in the GDL on the transient response of PEM fuel cells are determined. The degraded GDLs that had uneven hydrophobicity distributions cause local water flooding inside the GDL and induce lower and unstable voltage responses after load changes.

  • PDF

Evaluation of Structural Integrity and Heat Exchange Efficiency for Dimpled Tube Type EGR Cooler (딤플 튜브형 EGR Cooler 구조건전성 및 열효율 평가)

  • Seo, Young-Ho;Lee, Hyun-Min;Park, Jung-Won;Ku, Tae-Wan;Kim, Jeong;Kang, Beom-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.554-559
    • /
    • 2008
  • Most of vehicle manufacturers have applied exhaust gas recirculation (EGR) system to the development of diesel engines in order to obtain the high thermal efficiency without $NO_X$ and Particulate Matter (PM) emitted from the engine. EGR system, which reflow a cooled exhaust gas from vehicles burning diesel as fuel to a combustion chamber of engine, has been used to solve this problem. In order to confirm the safety of the EGR system, finite element analysis was carried out. The safety of EGR system against temperature variation in the shell and tubes was evaluated through the thermal and structural analysis, and the modal analysis using ANSYS was also performed. Finally, the performance of EGR system was verified through the experiment and numerical simulation using effectiveness-NTU method. Program for the estimation of the heat exchange efficiency of the EGR system with regard to the dimpled tube shape was developed.

  • PDF

A study on Characteristics of Airborne Dusts in Seoul Subway Stations (서울 지하철 내 공기 중 먼지의 특성에 관한 연구)

  • 김진경;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.154-160
    • /
    • 2004
  • The purpose of this study was to evaluate airborne concentrations and characteristics of TSP, IPM, TPM and RPM in Seoul subway stations. Sampling was performed at 14 stations from April 11 to 29, 2002. Size-selective dust concentrations and metal concentrations were measured by gravimetric method and ICP-AES, respectively. The geometric mean of TSP, IPM, TPM and RPM concentrations in Seoul subway stations were 176$\mu\textrm{g}$/㎥, 348$\mu\textrm{g}$/㎥, 158$\mu\textrm{g}$/㎥ and 104$\mu\textrm{g}$/㎥, respectively. Dust concentrations in pathway were the highest and those in lobby were the lowest. The size distribution of dusts was significantly different by location of collection. When the deposition rate into pulmonary gas exchange region was estimated by size distribution, the deposition rate of dust collected from platform was higher than those of dust collected from lobby and pathway. The lower the basement levels were, the higher the deposition rates of dusts into tracheobronchial region and gas exchange region were. Copper and iron concentrations measured in platform higher were than those in other areas.