• 제목/요약/키워드: Gas discharges

검색결과 119건 처리시간 0.026초

Analysis of flat fluorescent lamp discharges for LCD backlight unit by using two-dimensional fluid simulation code

  • Yoon, Hyun-Jin;Ha, Chang-Seung;Lee, Hae-June
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1569-1572
    • /
    • 2007
  • A two-dimensional fluid simulation code has been developed in order to investigate discharge phenomena and to improve plasma luminous efficiency in a Hg flat fluorescent lamp (FFL) for an LCD backlight unit. In this study, the method of a two-dimensional fluid simulation for FFL is explained and the simulation results of Hg-Ar-Ne mixture gas are presented for the enhancement of the luminance efficiency. The effects of various parameters, such as driving voltage, frequency, and gas mixture ratio, are investigated. The luminance efficiency increased with increasing fraction of mercury but the increasing fraction of argon did not affect the efficiency much.

  • PDF

UHF 이중대역법을 이용한 GIS PD 분석 (GlSPD Analysis Using UHF Dual-Band Method)

  • 이상화;최재구;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.63-66
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD defecting system in which PD signals are defected into the dual UHF band. Thc UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High hand to Full band increases with gas pressure.

  • PDF

Detection of the Ultrasonic Signals due to Partial Discharges in a 154kV Transformer

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권6호
    • /
    • pp.297-303
    • /
    • 2002
  • We have developed an on-line ultrasonic detector to monitor partial discharge in an operating transformer. The ultrasonic sensor has 150[KHz] resonance frequency and contains a pre-amplifier with 60[㏈] gain. The on-line ultrasonic detector has 50~300[KHz] frequency band-pass filter to remove electrical and mechanical noises from the transformer. This detector has an ultrasonic signal discrimination algorithm which discriminates ultrasonic signals due to partial discharge in a transformer. A moving average method of ultrasonic signal number was employed to effectively monitor the increasing trend of the partial discharge. This paper describes an experience of partial discharge detection in a 154[㎸] operating transformer using an ultrasonic detector. With regards to gas analysis in oil, C2H2 gas was produced with a warning level in this transformer We detected ultrasonic signals on the transformer steel wall, and estimated the position of partial discharge. With further inspection, we found carbonized marks due to partial discharge on the supporting bolt which fastens the windings.

After-glows in $N_2$ RF Flowing Plasma

  • 이민욱;오수기
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.489-489
    • /
    • 2012
  • The vibrational distribution of $N_2$ (B, v') in after-glows in $N_2$ RF flowing plasma was investigated. The optical emission of the after-glow was studied as function of distance from plasma. In a tube 2.1 cm, the gas pressure varied 8 Torr with 1000sccm nitrogen gas flowing late.. The discharges were excited by two ring-electrode powered by RF 13.56 MHz 100 Watt. $N_2$ (B, v') vibrational distribution was analyzed to see depends of position in after-glow. Dissociation rate of $N_2$ varied showing maximum in the late after-glow region. We studied $N_2$ RF capacitive flowing plasmas and afterglows by emission spectroscopy and by NO titration to determine the density of N-atoms.

  • PDF

Townsend 방전영역의 불꽃전압에 미치는 음극표면상태의 영향 (The Influence of the Cathode Surface State on the Spark Voltage in the Townsend Discharge Domain)

  • 백용현
    • 전기의세계
    • /
    • 제28권1호
    • /
    • pp.73-82
    • /
    • 1979
  • There are a great number of papers on the Townsend discharge in gases, and many of them are concerned with the effect of the cathode. It has been regarded that there are two kinds of effect of the electrodes, especially of the cathode; (a) the effect caused by the difference of the cathode material and (b) the effect by the change of the cathode surface state even in the same material. Both of them may change the secondary coefficient following after the change of the work function, and the atter may further change the primary ionization coefficient as foreign atoms on the surface may be dseorbed in sparks to decrease the purity of the gas. Thus the two effects must be investigated independently to study the roles of the cathode in gas discharges. In this report the effect of the cathode material on the sparking voltage is described. The experiment is also carried out under the condition that the desorption of impurities from the cathode be negligible. From these the new correlativity between the work function of the cathode and the sparking voltage is obtained. In addition, the interesting character of the minimum point of the Paschen's curve can be found.

  • PDF

초고압 GIS의 CT 단자부를 이용한 Semi-내장형 UHF PD 센서 개발 및 적용 (Development and application of the semi-internal type UHF PD sensor for Gas Insulated Switchgear)

  • 강원종;이도훈;이용희;신양섭;김영근;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2038-2039
    • /
    • 2007
  • In this work, a novel semi-internal type UHF PD sensor has been proposed and related investigations has been performed in order to detect the partial discharges that could be possibly produced at the insulation system of the gas insulated switchgear(GIS). This sensor was designed to mount on the CT terminal hole of GIS using the spiral antenna theory. Therefore this type sensor can be install on GIS during the power apparatus has been operation and better sensitivity compare to the commercial external type UHF PD sensor.

  • PDF

EXHAUST GAS HEAT RECOVERY SYSTEM FOR PLANT BED HEATING IN GREENHOUSE PRODUCTION

  • Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.;Kang, G.C.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.639-646
    • /
    • 2000
  • Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season in Korea. However, since the heat efficiency of the heater is about 80%, considerable unused heat in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust gas heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The system consists of a heat exchanger made of copper pipes, ${\phi}\;12.7{\times}0.7t$ located inside the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tame The total heat exchanger area is $1.5m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to performance test it can recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690{\ell}$/hr from the waste heat discharged. The exhaust gas temperature left from the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{circ}C$ from $21^{circ}C$ at the water flow rate of $690{\ell}$/hr. And, the condensed water amount varies from 16 to $43m{\ell}$ at the same water circulation rates. This condensing heat recovery system can reduce boiler fuel consumption amount in a day by 34% according to the feasibility study of the actual mimitomato greenhouse. No combustion load was observed in the hot air heater.

  • PDF

무성-연면 복합방전형 오존발생기의 오존생성 및 NO 가스 제거특성 (Ozone Generation and NO Gas Removal Characteristics a Silent-Surface Hybrid Discharge Type Ozonizer)

  • 송현직;이광식
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.32-38
    • /
    • 2005
  • 본 논문에서는 대기오염물질인 Nitrogen Oxides(NO) 가스를 제거하기 위하여 3개의 전극이 장착된 하나의 방전 공간에 무성방전과 연면방전을 동시에 발생가능한 복합방전형 오존발생기를 설계 제작하였다. 전압인가 방식에 따라 3가지 형태의 오존발생기로 구성가능한 복합방전형 오존발생기에 유입하는 산소원료가스의 유량, 방전전력 및 오존발생기의 종류에 따른 방전 및 오존생성특성을 연구 검토한 결과, 8334[ppm] 및 3249[mg/h]의 오존을 얻을 수 있었다. 또한 NO(1200[ppm])/$N_2$ 가스의 입력방식에 따른 NO 가스 제거특성을 방전전력 및 오존발생기의 종류에 따라 연구 검토한 결과, 최대 100[%]의 제거율을 얻을 수 있었다.

SOFC/가스터빈 혼합발전을 위한 SOFC 생성물의 연소특성 (Combustion Characteristics of the SOFC Products for SOFC/Gas Turbine Hybrid Power Generation System)

  • 이병준;배철한
    • 한국연소학회지
    • /
    • 제19권3호
    • /
    • pp.44-52
    • /
    • 2014
  • Solid oxide fuel cell(SOFC) makes electric power using hydrogen or reformed from methane and emits high temperature products that contain flammable species like hydrogen, carbon monoxide and methane which varies with operation condition. SOFC/gas turbine integrated system which uses thermal and chemical energy of the discharges is more efficient than SOFC itself. Burning character of the SOFC products will affect the efficiency and stability of the system. Experiments were conducted to know the characteristics of the flame for two typical composition of SOFC products, i.e. start-up and steady state composition. When coflowing air temperature was higher than $600^{\circ}C$, auto-ignitin occurred for both fuels. Though start-up fuel has higher contents of hydrogen, it makes longer flame than steady state composition. It was inferred that the amount of oxidizer necessary to burn makes this phenomenon. Steady state composition fuel was unstable since it contains lots of water. Nozzle that had 6 holes, distance between each hole was 16.7 times of hole diameter, improved the stability of the flame.

저기압희유 gas중에서 불꽃전압에 미치는 음극표면상태의 영향 (The Influence Of The Cathode Surface State On The Spark Voltage In The Low Pressure Gare Gas)

  • 백용현
    • 전기의세계
    • /
    • 제23권4호
    • /
    • pp.46-52
    • /
    • 1974
  • Generally, it has been regarded that there are two kinds of the effect of the electrodes, especially of the cathode in the gas discharge, (a) the effect caused by the difference of the cathode meterial and (b) the effect by the change of the cathode surface state even in the same meterials. Thus the two effects must be investigated independently to study the roles of the cathode in gas discharges. This paper measured sparking voltage in Rare gas (Ar, He) for the change of sparking voltage in repeating sparks and for the effect of (a) and (b) mentioned above, under the condition that the desorption of impurities from the cathod can be nigligible, and it is obtained that the correlative relations of the work function, sparking voltage and secondary coefficient are comparatively simple. In addition, the interesting character of the minimum point of the paschen's curves is found. The results were as follows; 1) The value of (pd)min with minimum pint of sparking voltage, (Vs)min, is 0.7-0.9 Torr. cm in Argon, but is 5.6-7.1 Torr. cm in Helium, and Paschen's curve in Helium shows slow curve than in Argon. 2) The minimum point of the Paschen's curve is satisfied actually Townsend's self sustaining criterion in Argon, but non-satisfaction in Helium, and the Townsend's secondary coefficient .gamma. action have compound property (.gamma.$_{i}$, .gamma.$_{p}$, .gamma.$_{m}$) in Helium. 3) The dependenting character of work function in Helium is less than in Argon. 4) The minimum point of sparking voltage increase under oxidized electrode than clear electrode in Au and Ag, but minimum point decrease in Ni and Cu.

  • PDF