• Title/Summary/Keyword: Gas diagnosis

Search Result 392, Processing Time 0.028 seconds

Characterisrics of Dissolved Gas Distribution in Oil with Thermal and Electrical Degradation in Oil Imersed Paper Insulation (유침 절연에서 전기적 및 열적 열화에 따른 유중가스분포특성)

  • Sun, Jong-Ho;Yi, Sang-Hwa;Kim, Kwang-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.136-144
    • /
    • 2004
  • Dissolved gas in oil analysis has been used for fault diagnosis of oil immersed insulation. In this paper to improve the reliability in deciding the degradation causes of the oil immersed insulation, we carried out electrical and thermal degradations for the insulations, and analyzed the characteristics of dissolved gases distribution on each situation. As a result more reliable faults discrimination is possible if we use the interrelation of factors like key gases and gas compositions of hydrocarbon gases and ratios of CO/$CO_2$.

A study on Defect Diagnosis of Gas Turbine Engine Using Hybrid SVM-ANN in Off-Design Region

  • Seo, Dong-Hyuck;Choi, Won-Jun;Roh, Tae-Seong;Choi, Dong-Whan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.72-79
    • /
    • 2008
  • The weak point of the artificial neural network(ANN) is that it is easy to fall in local minima when it learns too much nonlinear data. Accordingly, the classification ratio must be low. To overcome this weakness, the hybrid method has been proposed. That is, the ANN learns data selectively after detecting the defect position by the support vector machine(SVM). First, the SVM has been used for determination of the defect position and then the magnitude of the defect has been measured by the ANN. In off-design condition, the operation region of the engine is wide and the nonlinearity of learning data increases. The module system, dividing the whole operating region into reasonably small-size sections, has been suggested to solve this problem. In this study, the proposed algorithm has diagnosed the defects of triple components as well as single and dual components of the gas turbine engine in off-design condition.

  • PDF

Redesigning Taguchi Sensor

  • Hossein-Babaei Faramarz;Park, Won-Kyu
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.1
    • /
    • pp.11-15
    • /
    • 2005
  • The configuration of the main components and the physical structure of the Taguchi sensor, the first ceramic gas sensor mass produced, has remained virtually unaltered since its appearance 40 years ago. This device owns an excellent combination of the quality factors but is non-selective. The research efforts carried out to enhance the selectivity in this resistive gas sensor are briefly reviewed. A novel design, Capillary-attached Gas Sensor (CGS), is introduced, which employs the same ceramic components used for the fabrication of a classical Taguchi sensor but in altered geometries. CGS presents remarkable advantages from the view point of selectivity over the original design. While the steady state response of a CGS has the same significance as that of the Taguchi sensor, its transient response presents valuable diagnostic information. Fabrication and test of a prototype CGS is reported.

Performance Verification of Gas Insulated Switchgear using UHF Partial Discharge Diagnosis Method (UHF법 부분방전 진단기법에 의한 가스절연 개폐장치의 성능검증)

  • Kim, J.S.;Park, K.S.;Song, Y.P.;Kim, D.K.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.37-39
    • /
    • 2002
  • UHF method is very effective to diagnosis for partial discharge of GIS. In generally, inner UHF sensor can be attached on sheath cover of GIS under construction for periodic inspection. However, there is no inner UHF sensor for GIS of the domestic substation. We used the outer UHF sensor attached on spacer for GIS of existing substation. In this paper, we report the diagnosis result of partial discharge on 800kV GIS in domestic substation. From these results, we can find the quantity, reason and location of PD and certificate the performance of UHF method for partial discharge diagnosis of GIS.

  • PDF

Suspecting Intussusception and Recurrence Risk Stratification Using Clinical Data and Plain Abdominal Radiographs

  • Oh, Ye Rim;Je, Bo Kyung;Oh, Chaeyoun;Cha, Jae Hyung;Lee, Jee Hyun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.2
    • /
    • pp.135-144
    • /
    • 2021
  • Purpose: Although ultrasonography is the gold standard of diagnosing intussusception, plain abdomen radiograph (AXR) is often used to make differential diagnosis for pediatric patients with abdominal pain. In intussusception patients, we aimed to analyze the AXR and clinical data to determine the characteristics of early AXR findings associated with diagnosis of intussusception and recurrence after reduction. Methods: Between January 2011 and June 2018, 446 patients diagnosed with intussusception based on International Classification of Diseases-10 code of K56.1 were admitted. We retrospectively reviewed medical records of 398 patients who received air reduction; 51 of them have recurred after initial reduction. We evaluated six AXR features including absent ascending colon gas, absent transverse colon gas, target sign, meniscus sign, mass, and ileus. Clinical data and AXR features were compared between single episode and recurrence groups. Results: Two groups did not show significant differences regarding clinical data. Mean time to recurrence from air reduction was 3.4±3.2 days. Absent ascending colon gas (63.9%) was the most common feature in intussusception, followed by mass (29.1%). All of six AXR features were observed more frequently in the recurrence group. Absent transverse colon gas was the most closely associated AXR finding for recurrence (odds ratio, 2.964; 95% confidence interval, 1.327-6.618; p=0.008). Conclusion: In our study, absence of ascending colon gas was the most frequently seen AXR factor in intussusception patients. Extended and careful observation after reduction may be beneficial if such finding on AXR is found in intussusception patients.

A Monitoring System Based on an Artificial Neural Network for Real-Time Diagnosis on Operating Status of Piping System (가스배관망 작동상태 실시간 진단용 인공신경망 기반 모니터링 시스템)

  • Jeon, Min Gyu;Cho, Gyong Rae;Lee, Kang Ki;Doh, Deog Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.2
    • /
    • pp.199-206
    • /
    • 2015
  • In this study, a new diagnosis method which can predict the working states of a pipe or its element in realtime is proposed by using an artificial neural network. The displacement data of an inspection element of a piping system are obtained by the use of PIV (particle image velocimetry), and are used for teaching a neural network. The measurement system consists of a camera, a light source and a host computer in which the artificial neural network is installed. In order to validate the constructed monitoring system, performance test was attempted for two kinds of mobile phone of which vibration modes are known. Three values of acceleration (minimum, maximum, mean) were tested for teaching the neural network. It was verified that mean values were appropriate to be used for monitoring data. The constructed diagnosis system could monitor the operation condition of a gas pipe.

Measurement Technology of the Dissolved Hydrogen Gas Due to Partial Discharge in Oil using Gas Sensor (가스센서를 이용한 부분방전특성에 따른 유중수소가스 측정연구)

  • Heo, Jong-Cheol;Sun, Jong-Ho;Kang, Dong-Sik;Jeong, Joo-Young;Choo, Y.B.;Park, Jung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1784-1789
    • /
    • 2009
  • This paper describes the measurement technology of the dissolved hydrogen gas due to partial discharge in oil using gas sensor. For higher resolution and less error in measurement of the dissolved hydrogen gas in oil, the sensor outputs with ambient temperature which affect the sensor output characteristics should be considered. The sensor output trends with ambient temperature and the properties of the dissolved hydrogen gas in oil with partial discharge characteristic were analyzed through the test results. It was indicated that the sensor peak and the base voltage with measuring time were affected by ambient temperature and the measurement errors of the sensor output by temperature were reduced by using the difference between the peak and the base voltage rather than just the peak voltage. In addition, the hydrogen gas sensor outputs were increased with the increase of partial discharge energy.

A study of Partial Discharge Condition Monitoring Equipment In the Ultra High Voltage Gas-Insulated Switchgear(GIS) for Digital Sub-station application (디지털 변전소 적용을 위한 초고압 GIS 부분방전 상태감시장치 개발 연구)

  • Kim, Young-Noh;Cho, Young-Jun;Choi, Chul-Gang;Hwang, Chul-Min;Choi, Jae-Ok;Gang, Chang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1380-1381
    • /
    • 2008
  • By applying the digital sub-station, the change of various protect and measuring equipments has been applying. This paper is analyzed that the development of GIS partial discharge condition monitoring equipment is suited to the electricity IT technology and digital sub-station. It's constitution apply to be able to suit the data to high rank for GIS partial discharge condition monitoring equipment that is suited digital sub-station and Watch-dog module that be able to monitor the inner communication of the GIS partial discharge equipment. And then it also be able to apply of GIS partial discharge equipment when digital sub-station is applied.

  • PDF

Evaluation of Popping Performance of Safety Valves in City Gas Facilities (도시가스시설에서 안전밸브의 분출성능에 관한 평가 연구)

  • 김영규;김청균
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.104-108
    • /
    • 1998
  • In order to evaluate the performances of safety valves for low pressure, the popping pressure and flow rate of the natural gas have been investigated. The measured results of the popping pressure show that there is a big scattering depending on the manufacture year of a safety valve. And sample A showed the ideal popping pressure mode compared to other B and C samples. The popping flow rate of the safety valve is proportional to the seat size as the inlet pressure increases. These results may be used as a guideline for a design and diagnosis of the safety valve.

  • PDF

A Study on the integrity assessment of the high voltage transformer with Dissolved Gas Analysis (특고압 변압기 건전성 평가에 관한 연구)

  • Lee, Il-Moo;You, Sang-Bong;Joung, Hea-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1463-1464
    • /
    • 2015
  • This paper describes for the diagnosis insulating oil for transformers integrity assessment. The high-capacity oil transformer has several insulators are entered for the purpose of insulation, such as insulating oil, insulating paper and press board. Irradiated with a gas component dissolved in the insulating oil can analyze the status of the transformer, and can prevent a sudden accident in advance.

  • PDF