• Title/Summary/Keyword: Gas detection

Search Result 1,207, Processing Time 0.024 seconds

Comparison of Volatile Flavor Compounds in Meat of the Blue Crab Using V-SDE and SPME Methods (V-SDE와 SPME법에 의한 꽃게(Portunus trituberculatus)육의 휘발성 향기성분 비교)

  • Cha, Yong-Jun;Cho, Woo-Jin;Jeong, Eun-Jeong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.39 no.6
    • /
    • pp.441-446
    • /
    • 2006
  • Volatile flavor compounds in meat of the blue crab Portunus trituberculatus were compared using vacuum simultaneous steam distillation-solvent extraction (V-SDE) and solid phase microextraction (SPME)/ gas chromatography (GC)/ mass selective detection (MSD) methods. A total of 100 volatile flavor compounds were identified by both methods: 77 by V-SDE and 59 by SPME. These compounds were composed of 17 aldehydes, 12 ketones, 19 alcohols, 5 esters, 4 sulfur-containing compounds, 6 nitrogen-containing compounds, 23 aromatic compounds, 6 hydrocarbons, 2 terpenes, and 6 miscellaneous compounds. Although more compounds were detected using V-SDE than using SPME, the levels of all groups detected, except esters, were higher using SPME than using V-SDE. In addition to trimethylamine, aldehydes, and aromatic compounds, the S- and N-containing compounds with low thresholds are thought to have positive roles for flavors in the meat of the blue crab.

Effects of Preparation Method and Evaluations on Structural Integrity in Model Antigen-Containing Biodegradable Microspheres for Vaccine Delivery

  • Cho Seong-Wan;Kim Young-Kwon
    • Biomedical Science Letters
    • /
    • v.12 no.3
    • /
    • pp.177-183
    • /
    • 2006
  • To demonstrate the effect of formulation conditions and evaluations of structural integrity from ovalbumin containing poly lactide glycolide copolymer (PLGA) microspheres for Vaccine delivery, OVA microspheres were prepared by a W/O/W multiple emulsion solvent extraction technique. Dichloromethan (DCM) and Ethyl acetate (EA) were applied as an organic phase and poly vinyl alcohol (PVA) as a secondary emulsion stabilizer. Microspheres were characterized for particle size, morphology (optical microscopy and Scanning Electron Microscope (SEM)). Protein denaturation was evaluated by size exclusion chromatography (SEC), SDS-PAGE and isoelectric focusing (IEF). Residual organic solvent was estimated by gas chromatography (GC) and differential scanning calorimetry (DSC). Optical photomicrograph and SEM revealed that micro spheres were typically spherical but various morphologies were observed. Mean particle size $(d_{vs})$ of microspheres were in the range of $3{\sim}50{\mu}m$. Also, The protein stability was not affected by the fonnulation process and residual organic solvent was beyond the detection below 0.1ppm. These results demonstrated that micro spheres might be a good candidate for the parenteral vaccine delivery system.

  • PDF

Development of Fast-Response Portable NDIR Analyzer Using Semiconductor Devices

  • Kim, Woo-Seok;Lee, Jong-Hwa;Park, Young-Moo;Yoo, Jai-Suk;Park, Kyoung-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2099-2106
    • /
    • 2003
  • In this paper, a novel fast response NDIR analyzer (FRNDIR), which uses an electrically pulsed semiconductor emitter and dual type PbSe detector for the PPM-level detection of carbon dioxide (CO$_2$) at a wavelength of 4.28 $\mu\textrm{m}$, is described. Modulation of conventional NDIR energy typically occurs at 1 to 20 Hz. To achieve real time high-speed measurement, the new analyzer employs a semiconductor light emitter that can be modulated by electrical chopping. Updated measurements are obtained every one millisecond. The detector has two independent lead selenide (PbSe) with IR band pass filters. Both the emitter accuracy and the detector sensitivity are increased by thermoelectric cooling of up to -20 degrees C in all semiconductor devices. Here we report the use of semiconductor devices to achieve improved performance such that these devices have potential application to CO$_2$ gas measurement and, in particular, the measurement of fast response CO$_2$ concentration at millisecond level.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

Condition Monitoring of Rotating Machine with a Change in Speed Using Hidden Markov Model (은닉 마르코프 모델을 이용한 속도 변화가 있는 회전 기계의 상태 진단 기법)

  • Jang, M.;Lee, J.M.;Hwang, Y.;Cho, Y.J.;Song, J.B.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.5
    • /
    • pp.413-421
    • /
    • 2012
  • In industry, various rotating machinery such as pumps, gas turbines, compressors, electric motors, generators are being used as an important facility. Due to the industrial development, they make high performance(high-speed, high-pressure). As a result, we need more intelligent and reliable machine condition diagnosis techniques. Diagnosis technique using hidden Markov-model is proposed for an accurate and predictable condition diagnosis of various rotating machines and also has overcame the speed limitation of time/frequency method by using compensation of the rotational speed of rotor. In addition, existing artificial intelligence method needs defect state data for fault detection. hidden Markov model can overcome this limitation by using normal state data alone to detect fault of rotational machinery. Vibration analysis of step-up gearbox for wind turbine was applied to the study to ensure the robustness of diagnostic performance about compensation of the rotational speed. To assure the performance of normal state alone method, hidden Markov model was applied to experimental torque measuring gearbox in this study.

Heat Effects for the Volatile Organic Compounds emitted from Garlic and Kimchee (열처리가 마늘과 김치에서 발생되는 휘발성 유기화합물에 미치는 영향)

  • 김병순;양성봉
    • Journal of Environmental Science International
    • /
    • v.7 no.5
    • /
    • pp.615-622
    • /
    • 1998
  • The volatile organic compounds(VOCs) emitted from raw garlic and Kimchee were analyzed with thermal desorption or purge & trap/gas chromatography/mass selective detection method. Very offensive compounds such as methyl allyl sulfide, dimethyl sulfide, dimethyl disulfide, diallyl sulfide, methyl allyl disulfide, diallyl disulfide and dimethyl trisulfide were detected, and among them, dimethyl disulfide and dimethyl trisulfide were confirmed to be generated during the precocity of Kimchee or emitted from the stuff of Kimchee other than the garlic. Malodorous compounds emitted from the garlic or Kimchee were detected in the breath of a Korean and the refregirator keeping Kimchee. It was confirmed that the disufides emitted from the garlic or Kimchee were major components of offensive odor in the alveolar air and the refregirator. It was clarfied that heat process is very effective to reduce odorous VOCs in garlic or Kimchee.

  • PDF

An Experimental Investigation into the Characteristics of Sampling Module for East-Response Co2 Concentration Analyzer with NDIR (비분산 적외선 분광법을 이용한 Co2농도 고속 분석기의 Sampling Module 특성에 관한 실험적 연구)

  • Kim, Woo-Seok;Shon, Deok-Young;Park, Young-Moo;Yoo, Jae-Suk;Lee, Jong-Hwa
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.398-405
    • /
    • 2003
  • A fast response analyzer for measuring carbon dioxide concentration has been developed for transient characteristic and researches tested on internal combustion engine. The analyzer uses the well known NDIR(Non-Dispersive Infrared) method with miniaturized detection system, giving a time constant of approximately 30 microsecond, and sampling module consists of capillary tube. Since the transit time and the time constant of the sampling system depend on the sampling conditions, it is necessary to investigate the characteristics of sampling system before applied to exhaust gas measurement in engine. A unique method was designed to study the influence of the diameter of transfer sample line and operating conditions of the FRNDIR on transit time and time constant. A database of transit time and time constant was built up for different measured and simulated pressure conditions. The database can be used for correcting eventual $CO_2$ concentration measurement.

Determinaton of Chloride Ion Captured into Strong NaOH Solution from Chimney by Capillary Electrophoresis (모세관 전지영동법에 의한 굴뚝에서 포집된 NaOH 용액속의 염소이온의 측정)

  • 임인덕;성용익;김양선;임흥빈
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.3
    • /
    • pp.327-333
    • /
    • 1999
  • Determination of chloride ion in concentrated NaOH solution by capillary electrophoresis has been studied. The analysis was performed by indirect UV absorption detection using chromate buffer at 254nm. The matrix effect of the sample has been observed so that the sensitivity in strong NaOH solutaion has decreased up to 10% of that in distilled water. The pH effect of the sample on the sensitivity of CE peaks has been investigated. The method for increasing the sensitivity have been investigated and the optimum pH and concentration of the buffer were 7.5 and 10mM, respectively. A cationic surfactant cetyltrimethylammonium bromide(CTAB), was added to a buffer solution in order to reverse the electroosmotic flow(EOF) in the capillary. This results in a short analysis time and better peak shapes. Using this optimum condition, the determination of chloride ion in real environmental sample has been performed, which is captured in strong NaOH absorbent prepared for absorbing gas from chimney. The standard addition method has been applied for the quantitative analysis, and it was obtained the good reproducibility.

  • PDF

Decolorization of a Sulfonated Azo Dye, Congo Red, by Staphylococcus sp. EY-3

  • PARK, EUN-HEE;JANG, MOON-SUN;CHA, IN-HO;CHOI, YONG-LARK;CHO, YOUNG-SU;KIM, CHEORL-HO;LEE, YOUNG-CHOON
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.221-225
    • /
    • 2005
  • A Staphylococcus sp. EY-3 with the capability of decolorizing Congo Red was isolated from soil at an effluent treatment plant of a textile and dyeing industry. This strain was able to almost completely decolorize a high concentration of Congo Red in 48 h under aerobic conditions. Optimal color removal (more than 96%) was achieved at 30- 40oC, and no noticeable effects of different pH values (5.5- 8.0) on decolorization were observed. This strain also exhibited a remarkable decolorization capability against azo dyes under aerobic conditions, even at a high concentration (dyes 1 g/l) of dye. The metabolic product of Congo Red degradation by this strain was identified by gas chromatography with mass selective detection (GC/MSD) to be an amine derivative benzidine.

Simple Measurement of Livestock Foul Smells by Gas Detector Tube (검지관을 이용한 축산 악취 간이 측정방법 연구)

  • Jung, Jae-Chil;Ahn, Min-Ho;Jeong, Jong-Won;Choi, Hee-Seon;Kim, Tai-Jin
    • KSBB Journal
    • /
    • v.24 no.5
    • /
    • pp.420-424
    • /
    • 2009
  • The present study was aimed for the fetor in the livestock facilities. Simple detection systems for ammonia and hydrogen sulfide were examined to see the mechanism making the discoloration length of malodorous substance concentration. Detector tube for ammonia showed a good linearity of 99.6% while hydrogen sulfide detector tube gave 99.7% linearity with reproductivity of 95%.