• 제목/요약/키워드: Gas detection

검색결과 1,196건 처리시간 0.031초

Rock physics modeling in sand reservoir through well log analysis, Krishna-Godavari basin, India

  • Singha, Dip Kumar;Chatterjee, Rima
    • Geomechanics and Engineering
    • /
    • 제13권1호
    • /
    • pp.99-117
    • /
    • 2017
  • Rock physics modeling of sandstone reservoir from gas fields of Krishna-Godavari basin represents the link between reservoir parameters and seismic properties. The rock physics diagnostic models such as contact cement, constant cement and friable sand are chosen to characterize reservoir sands of two wells in this basin. Cementation is affected by the grain sorting and cement coating on the surface of the grain. The models show that the reservoir sands in two wells under examination have varying cementation from 2 to more than 6%. Distinct and separate velocity-porosity and elastic moduli-porosity trends are observed for reservoir zones of two wells. A methodology is adopted for generation of Rock Physics Template (RPT) based on fluid replacement modeling for Raghavapuram Shale and Gollapalli Sandstones of Early Cretaceous. The ratio of P-wave velocity to S-wave velocity (Vp/Vs) and P-impedance template, generated for this above formations is able to detect shale, brine sand and gas sand with varying water saturation and porosity from wells in the Endamuru and Suryaraopeta gas fields having same shallow marine depositional characters. This RPT predicted detection of water and gas sands are matched well with conventional neutron-density cross plot analysis.

Spray Characterization of Gas-Centered Swirl Coaxial Injectors Using an Optical Probe

  • ;홍문근;;;이수용
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.172-177
    • /
    • 2011
  • In order to investigate spray characteristics of gas-centered swirl coaxial injectors, a phase detection optical probe is employed to obtain the spatial evolution of the drop size and velocity. From the study on the optical probe responses under various impact angles, it is demonstrated that the drop size and velocity can be measured with an uncertainty less than 15% when the probe axis remains within about ${\pm}15^{\circ}$ of the drop velocity direction. This typical uncertainty is in good agreement with a previous study. It is also shown that the drop sizes measured by the optical probe are in accord with those evaluated by image processing techniques. Finally, the experiments with the optical probe are performed in dense sprays, as it were, in the near field of gas-centered swirl coaxial injectors. Some experimental results are presented and discussed to be of help to understanding of spray characteristics of the injectors.

  • PDF

지하상가 가스누출 사고 환자들에 대한 임상적 고찰 - 일산화탄소 중독 - (Clinical Evaluation of Patients Intoxicated by a Gas Leak at an Underground Shopping Center - Carbon Monoxide Poisoning -)

  • 안지영;고영길
    • 대한임상독성학회지
    • /
    • 제4권2호
    • /
    • pp.122-127
    • /
    • 2006
  • Purpose: It is not easy to detect carbon monoxide (CO) leakage, and CO-intoxicated patients do not show a specific set of symptoms. The aims of this study are to clinically evaluate patients with CO gas intoxication from a CO leak at an underground shopping center, and to discuss the establishment of a disaster prevention plan. Methods: A total of 51 patients intoxicated by CO gas exposure in a gas disaster at a underground shopping center in Seoul on September 8, 2006 were enrolled in this study, and the patients' medical records were retrospectively reviewed. Results: The mean patient age was $29.4{\pm}6.3$. The initial mean COHb level was $14.98{\pm}6.97%$. The number of patients with COHb greater than 25% was three, and six patients experienced a syncopal attack. Only one patient-was treated with hyperbaric oxygen therapy. However, none of the patients complained of severe neurologic or cardiovascular symptoms. Conclusion: The symptoms of CO intoxication are non-specific and difficult to define, and the detection of CO leak-age is difficult. Thus, workplaces should be equipped with leakage sensors and automatic alarm systems and should have develop disaster prevention plans.

  • PDF

기체크로마토그래피를 이용한 잔류농약 동시다성분 분석법 (Determination of Simultaneous Analytical Method of Residual Pesticides by Gas Chromatography)

  • 최원조;최계선;이희정;원영준;박흥재;김우성
    • 한국환경과학회지
    • /
    • 제18권12호
    • /
    • pp.1369-1381
    • /
    • 2009
  • The simultaneous determination of residual pesticides was developed using a gas chromatography. In this study, a simple and reliable methodology was improved to detect 175 kinds of residual pesticides by a liquid-liquid extraction procedure, followed by chromatographic analysis by gas chromatography. The 175 kinds of residual pesticides was classified into 4 groups according to the chemical structure, column type, resolution and sensitivity. The soybean sample selected for recovery experiment was not detected any pesticides. The recovery rates were ranged from 70.6% to 119.7% in most pesticides. The relative standard deviation (RSD 0.3~5.6%) was lower than 5.6% in all cases. The limits of detection (LOD) was lower than the maximum residue levels established by Korean legislations. The method has been successfully applied to the analysis of approximately 130 real samples.

Structural and Electrical Properties of WOx Thin Films Deposited by Direct Current Reactive Sputtering for NOx Gas Sensor

  • Yoon, Young-Soo;Kim, Tae-Song;Park, Won-Kook
    • 한국세라믹학회지
    • /
    • 제41권2호
    • /
    • pp.97-101
    • /
    • 2004
  • W $O_{x}$-based semiconductor type thin film gas sensor was fabricated for the detection of N $O_{x}$ by reactive d.c. sputtering method. The relative oxidation state of the deposited W $O_{x}$ films was approximately compared by the calculation of the difference of the binding energy between Ols to W4 $f_{7}$2/ core level XPS spectra in the standard W $O_3$ powder of known composition. As the annealing temperature increased from 500 to 80$0^{\circ}C$, relative oxygen contents and grain size of the sputtered films were gradually increased. As the results of sensitivity ( $R_{gas}$/ $R_{air}$) measurements for the 5 ppm N $O_2$ gas, the sensitivity was 110 and the sensor showed recovery time as fast as 200 s. The other sensor properties were examined in terms of surface microstructure, annealing temperature, and relative oxygen contents. These results indicated that the W $O_3$ thin film with well controlled structure is a good candidate for monitoring and controlling of automobile exhaust.haust.t.t.t.

Pt/Ti 발열체가 내장된 TMA 가스 측정용 ZnO 박막 가스 센서 (ZnO thin film Gas sensors for detection of TMA gas with Pt/Ti thin film heater)

  • 류지열;박성현;최혁환;권태하
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.127-135
    • /
    • 1996
  • To increase the sensitivity and the selectivity of the sensors to TMA gas, the composition ratio and the growth conditions of the ZnO films are studied. Annealing of the ZnO films in the various time ranges and temperatures in the oxygen is carried out to enhance the stbility of the electrical resistance. Pt/Ti heater deposited on backside of the substrates in used to control the operating temperature of th esensor. The ZnO thin film sensors doped to 4.0 wt% $Al_{2}$O$_{3}$ 1.0wt.% TiO$_{2}$ and 0.2wt.% V$_{2}$O$_{5}$ exhibited a high sensitivity and an excellent selectivity for TMA gas. The sensors made with the thin films annealed at 700$^{\circ}$C for 60 minutes in the oxygen atmosphere had a good stability and linearity. The heater deposited in the ratio of 1 to 1 (Pt:Ti) had a good heating properties. The sensors fabricated using above conditions showed a good response to the actual gases of a mackerel at a step of deterioration after death.

  • PDF

안드로이드 기반 산업용 가스터빈 원격 모니터링 시스템 구현 (Android-based Implementation of Remote Monitoring System for Industrial Gas Turbines)

  • 최준혁;이동익
    • 한국전자통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.369-376
    • /
    • 2018
  • 본 논문은 안드로이드 기반으로 구현된 실시간 원격 모니터링 시스템을 제안한다. 원격 모니터링 기술은 모니터링에 필요한 비용의 절감과 비정상 상태의 빠른 발견에 이점이 있다. 제안된 모니터링 시스템은 민감한 정보를 보호하기 위해 RSA(Rivest Shamir Adleman) 알고리즘을 이용하는 보안 통신을 사용한다. 가스터빈의 이상 상황이 발생하였을 때, 원격 모니터링 시스템은 사용자의 주의를 끌기 위해 푸시 메시지를 이용한 경고를 한다. 제안된 시스템은 가상 데이터 발생기를 포함하는 실험 환경에서의 실험으로 검증되었다.

지하철 역내 가스 검출 원격 모니터링 시스템 구현 (Development of a remote monitoring system for gas detection at the subway station)

  • 박용만;김희식;김규식;이문규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

마비성 장폐색증에 병발된 간문맥 내 가스 (Hepatic portal venous gas in paralytic ileus)

  • 이지은;손민수;허준호;조선영;최선택;성영호
    • Journal of Yeungnam Medical Science
    • /
    • 제31권1호
    • /
    • pp.56-60
    • /
    • 2014
  • Hepatic portal venous gas (HPVG) is a rare radiographic finding associated with severe intra-abdominal disease and fatal outcome. Most cases of HPVG are historically related to mesenteric ischemia accompanied by bowel necrosis. The current spread of computed tomography scan promotes not only the early detection of related severe diseases but also the identification of other causes of HPVG. It has been reported in many non-fatal conditions, such as inflammatory bowel disease, intra-abdominal abscess, bowel obstruction, paralytic ileus, endoscopic retrograde cholangiopancreatography and endoscopic sphincterotomy, and gastric dilatation. Among these, paralytic ileus is a very rare condition, with no case yet reported in South Korea. Reported herein is a case of HPVG in paralytic ileus, which was treated well internally and was promptly resolved.

산화구리 나노선 센서의 황화수소 감지특성 (Detection of H2S Gas with CuO Nanowire Sensor)

  • 이동석;김도진;김효진
    • 한국재료학회지
    • /
    • 제25권5호
    • /
    • pp.238-246
    • /
    • 2015
  • $H_2S$ is a flammable toxic gas that can be produced in plants, mines, and industries and is especially fatal to human body. In this study, CuO nanowire structure with high porosity was fabricated by deposition of copper on highly porous singlewall carbon nanotube (SWCNT) template followed by oxidation. The SWCNT template was formed on alumina substrates by the arc-discharge method. The oxidation temperatures for Cu nanowires were varied from 400 to $800^{\circ}C$. The morphology and sensing properties of the CuO nanowire sensor were characterized by FESEM, Raman spectroscopy, XPS, XRD, and currentvoltage examination. The $H_2S$ gas sensing properties were carried out at different operating temperatures using dry air as the carrier gas. The CuO nanowire structure oxidized at $800^{\circ}C$ showed the highest response at the lowest operating temperature of $150^{\circ}C$. The optimum operating temperature was shifted to higher temperature to $300^{\circ}C$ as the oxidation temperature was lowered. The results were discussed based on the mechanisms of the reaction with ionosorbed oxygen and the CuS formation reaction on the surface.