• 제목/요약/키워드: Gas detection

검색결과 1,196건 처리시간 0.033초

마이크로 플랫폼 상에 나노 감지 재료를 이용한 저전력 NOX 센서의 설계 및 제조 (Design and Fabrication of a Micro Gas Sensor Using Nano Sensing Materials on Multi-layer Type Micro Platform with Low Power Consumption)

  • 박상일;박준식;이민호;박광범;김성동;박효덕;이인규
    • 대한임베디드공학회논문지
    • /
    • 제2권2호
    • /
    • pp.76-81
    • /
    • 2007
  • A novel multi-layer type micro gas sensor for $NO_X$ detection was designed and fabricated. Micro platform defined as type II-1 in this article for micro gas sensor was fabricated using the MEMS technology to meet the demanding needs of lower power consumption. Nano composite materials were fabricated with nanosized tin oxide powder and $\underline{m}$ulti-$\underline{w}$all $\underline{c}$arbon $\underline{n}$ano $\underline{t}$ube (MWCNT) to improve sensitivity. We investigated characteristics of fabricated multi-layer type micro gas sensor with $NO_2$ concentration variations at constant 2.2 V. Sensitivity (S) of micro gas sensor were observed to increase from 2.9, to 7.4 and 11.2 as concentrations of $NO_2$ gases increased from 2.4 ppm, to 3.6 ppm and 4.9 ppm. When 2.4 ppm of $NO_2$ gas was applied, response time and recovery time of micro gas sensor were recorded as 101 seconds and 142 seconds, respectively.

  • PDF

산화물 반도체를 이용한 최신 호기센서 기술 동향 (Recent Developments in Metal Oxide Gas Sensors for Breath Analysis)

  • 윤지욱;이종흔
    • 세라미스트
    • /
    • 제22권1호
    • /
    • pp.70-81
    • /
    • 2019
  • Breath analysis is rapidly evolving as a non-invasive disease recognition and diagnosis method. Metal oxide gas sensors are one of the most ideal platforms for realizing portable, hand-held breath analysis devices in the near future. This paper reviewed the recent developments in metal oxide gas sensors detecting exhaled biomarker gases such as nitric oxides, acetone, ammonia, hydrogen sulfide, and hydrocarbons. Emphasis was placed on strategies to tailor sensing materials/films capable of highly selective and sensitive detection of biomarker gases with negligible cross-response to ethanol, the major interfering breath gas. Specific examples were given to highlight the validity of the strategies, which include optimization of sensing temperature, doping additives, utilizing acid-base interaction, loading catalysts, and controlling gas reforming reaction. In addition, we briefly discussed the design and optimization method of gas sensor arrays for implementing the simultaneous assessment of multiple diseases. Breath analysis using high-performance metal oxide gas sensors/arrays will open new roads for point-of-care diagnosis of diseases such as asthma, diabetes, kidney dysfunction, halitosis, and lung cancer.

복합 유해 가스 센서 기반의 조기 경보 시스템을 위한 재난 전조 감시 기준에 관한 연구 (A Study on the Monitoring Criteria of Disaster Signs for Early-warning System based on Multiple Hazardous Gas Sensor)

  • 한규상;박소순;윤인섭
    • 한국가스학회지
    • /
    • 제17권2호
    • /
    • pp.28-35
    • /
    • 2013
  • 대도시 내에 밀집하여 증가하고 있는 대형 복합 건축물은 그 규모와 복잡성으로 인해 유해가스 관련 사고발생시 대형 재난으로의 확대 가능성이 상존한다. 이에 대한 대응책으로, 다종의 유해가스를 감지하는 복합 가스 센서와 이로부터 수집한 정보를 활용한 조기 경보 시스템이 연구되고 있다. 이와 같은 센서 기반 재난 전조 감시 시스템의 효과적인 적용과 운영을 위해서는 적합한 기준이 먼저 마련되어야 한다. 본 연구에서는 유해가스의 감지와 조기 경보 발령을 위한 경보 기준 농도를 제시하고, 각 경보 단계별로 대응 활동과 정보 전파 등 재난 대응 체계를 제안하였다. 재난 감시 기준을 통해 유해가스 관련사고 발생 시 조기에 위험을 감지하여 사고의 경과에 따라 효과적인 대응을 이끌어 낼 수 있다.

Pt, Ni, Cr이 도포된 튜브형 SnO2 나노섬유의 합성과 가스 감응특성 (Preparation of Pt-, Ni- and Cr-Decorated SnO2 Tubular Nanofibers and Their Gas Sensing Properties)

  • 김보영;이철순;박준식;이종흔
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.211-215
    • /
    • 2014
  • The Pt-, Ni- and Cr-decorated tubular $SnO_2$ nanofibers for gas sensors were prepared by the electrospinning of polyvinylpyrrolidone (PVP) nanofibers containing Pt, Ni, and Cr precursors, the sputtering of $SnO_2$ on the electrospun PVP nanofibers, and the removal of sacrificial PVP parts by heat treatment at $600^{\circ}C$ for 2 h. Pt-decorated tubular $SnO_2$ nanofibers showed high response ($R_a/R_g=210.5$, $R_g$: resistance in gas, $R_a$: resistance in air) to 5 ppm $C_2H_5OH$ at $350^{\circ}C$ with negligible cross-responses to other interference gases (5 ppm trimethylamine, $NH_3$, HCHO, p-xylene, toluene and benzene). Cr-decorated tubular $SnO_2$nanofibers showed the selective detection of p-xylene at $400^{\circ}C$. In contrast, no significant selectivity to a specific gas was found in Ni-decorated tubular $SnO_2$ nanofibers. The selective and sensitive detection of gases using Pt-decorated and Cr-decorated tubular $SnO_2$ nanofibers were discussed in relation to the catalytic promotion of gas sensing reaction.

압력값 모니터링을 통한 배관 내 가스누출감지에 대한 실험적 연구 (An Experimental Study on Detection of Gas Leakage Position by Monitoring Pressure Values at City Gas Pipeline)

  • 진경민;최규홍;이송규;정태용;신동훈;황승식;오정석
    • 에너지공학
    • /
    • 제20권4호
    • /
    • pp.292-297
    • /
    • 2011
  • 도시가스 배관망의 안전관리 및 위험예측은 매우 중요한 문제로 인식되고 있으며 가스 누출지점을 실시간으로 감지함으로써 안전사고 예방을 위한 노력은 필수적이다. 따라서, 본 연구에서는 가스누출 시, 압력변화에 따른 상관관계(correlation)를 통해 실시간 누출지점감지를 목적으로 연구를 진행하였다. 본 연구에서는 총 378 m의 배관에 5개의 누출밸브를 설치하여 실험하였고, 시뮬레이터를 통해 누출지점을 감지함으로서 실제 누출지점과 비교해 보았다. 실험결과, 실험을 통한 누출지점과 실제 누출지점은 6 m 내의 차이를 보였으며 향후, 본 기술의 적용이 필요한 위험구역에서의 실증을 통한 상용화가 수반되어야 할 것이다.

$\cdot$무선 데이터 통신을 이용한 천연가스 정압소의 안전방재 시스템 개발 (Development of Anti-disaster System for Natural Gas Governor Station Using Wire and/or Wireless Communication)

  • 유휘룡;박대진;구성자;박승수;노용우
    • 한국가스학회지
    • /
    • 제3권2호
    • /
    • pp.17-23
    • /
    • 1999
  • 본 연구는 전국에 산재된 천연가스 정압소를 위한 안전방재 시스템 개발을 위하여 수행되었다. 정압소에서 발생할 수 있는 사고를 미연에 방지하기 위하여 정압소의 안전상황을 수집/전송하는 RTU(Remote Terminal Unit)를 개발하여 정압소의 운전원의 역할을 대신하게 하였다. 그리고 전송된 각 정압소의 안전상황을 효과적으로 통제소 운전원에게 전달하며 추후 안전에 대한 분석을 위하여 데이터베이스 및 MMI(Man Machine Interface)를 개발하였다. 안정적인 천연가스 공급의 모든 프로세스을 제어하며, 각종 파라미터를 감시하는 원방 감시 제어 시스템(이하 SCADA 시스템)의 유선 통신 설비가 사고에 의해 무용화 될 경우, 정압소의 상황을 통제실로 전송하기 위하여 유선 및 무선 데이터 통신을 혼합한 유$\cdot$무선 자동 전환 시스템을 개발하였다. 한편 GPS(Global Position System) 및 GIS(Geometric Information System) 기술을 이용한 순찰차량 관리 시스템을 개발하여 정압소에서 이상 징후를 보일 경우 통제소 및 순찰차량에서 동시에 정압소의 상황을 파악할 수 있게 하여 능동적인 대처가 가능하게 하였다. 그리고 3축 가속도 센서를 이용하여 지진을 감지하고 전송하는 지진 감지 및 전송 시스템을 개발하였다. 지진 발생시 ESV(Emergency Shutoff Valve)를 차단할 수 있도록 최대 지반 가속도 및 SI(Spectrum Intensity)값의 크기를 전송해 줌으로서 대형사고를 방지하도록 하였다.

  • PDF

A novel ceramic GEM used for neutron detection

  • Zhou, Jianrong;Zhou, Xiaojuan;Zhou, Jianjin;Jiang, Xingfen;Yang, Jianqing;Zhu, Lin;Yang, Wenqin;Yang, Tao;Xu, Hong;Xia, Yuanguang;Yang, Gui-an;Xie, Yuguang;Huang, Chaoqiang;Hu, Bitao;Sun, Zhijia;Chen, Yuanbo
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1277-1281
    • /
    • 2020
  • A novel ceramic Gas Electron Multiplier (GEM) has been developed to meet the demand of high counting rate for the neutron detection which is an alternative to 3He-based detector at China Spallation Neutron Source (CSNS). An experiment was performed to measure the neutron transmittance of ceramic-GEM and FR4-GEM at the small angle neutron scattering (SANS) instrument. The result showed the ceramic-GEM has higher transmittance and less self-scattering especially for cold neutrons. One single ceramic GEM could give a gain of 102-104 in the mixture gas of Ar and CO2 (90%:10%) and its energy resolution was about 27.7% by using 55Fe X ray of 5.9 keV. A prototype has been developed in order to investigate the performances of the ceramic GEM-based neutron detector. Several neutron beam tests, including detection efficiency, spatial resolution, two-dimensional imaging, and wavelength spectrum, were carried out at CSNS and China Mianyang Research Reactor (CMRR). The results show that the ceramic GEM-based neutron detector is a good candidate to measure the high intensity neutrons.