• 제목/요약/키워드: Gas detection

검색결과 1,196건 처리시간 0.027초

An ITO/Au/ITO Thin Film Gas Sensor for Methanol Detection at Room Temperature

  • Jeong, Cheol-Woo;Shin, Chang-Ho;Kim, Dae-Il;Chae, Joo-Hyun;Kim, Yu-Sung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권2호
    • /
    • pp.77-80
    • /
    • 2010
  • Indium tin oxide (ITO) films with a 5 nm thick Au interlayer were prepared on glass substrates. The effects of the Au interlayer on the gas sensitivity for detecting methanol vapors were investigated at room temperature. The conductivity of the film sensor increased upon exposure to methanol vapor and the sensitivity also increased proportionally with the methanol vapor concentration. In terms of the sensitivity measurements, the ITO film sensor with an Au interlayer shows a higher sensitivity than that of the conventional ITO film sensor. This approach is promising in gaining improvement in the performance of ITO gas sensors used for the detection of methanol vapor at room temperature.

배관계의 가스누설탐지를 위한 음향모델 연구 (A Study on an Acoustical Model for Gas Leak Detection in a Pipeline)

  • 양윤상;이동훈;고재필
    • 설비공학논문집
    • /
    • 제26권2호
    • /
    • pp.91-96
    • /
    • 2014
  • An acoustical model for detecting the leak location in a buried gas pipeline has been developed. This model is divided into an experimental model for sound diagnosis, and a theoretical model for sound prediction, which is based on the transfer matrix method, representing the sound pressure and the volume velocity as state variables. The power spectrum is measured by attaching only one microphone to the closed end pipe. It has been shown that the response magnitude of acoustic pressure signals calculated by the acoustical model depends upon the thickness and diameter of a pinhole. The validity for the acoustical model has been verified through a comparison between the measured and calculated results.

유체배관 오염 검출장치 개발에 관한 연구 (A Study of the Device Development for the Contamination Detection in the Delivery Line)

  • 정이하;김병한;홍주표
    • 반도체디스플레이기술학회지
    • /
    • 제14권1호
    • /
    • pp.45-49
    • /
    • 2015
  • Process gases with vapor or liquid phase as well as gas phase may experience alteration in itself or be contaminated in the fluid pipe to the process chamber. And thus it result in as particles or defects on the substrates in semiconductor, LCD, LED manufacturing. Purifiers and filters are used for control of contamination. However, none of detection device is available in the delivery line. In this paper, we propose simple device with lighting and sensing in order to predict contamination of the fluid or the tube wall. For some general purpose gases, it showed constant voltage output regardless of the flow rates. But, the smoke and the moisture in the air lowered the figure due to its concentration. Numerical values for several solid and liquid media were obtained. And, the operating temperature tendency was investigated.

원통형 Microwave Cavity를 이용한 기체크로마토그라프 원자발광 검출기의 특성에 관한 연구 (Characterization of Atomic Emission Detector for Gas Chromatography Using Cylindrical Microwave Cavity)

  • 박영주;유희수
    • 분석과학
    • /
    • 제5권3호
    • /
    • pp.263-268
    • /
    • 1992
  • 원통형 microwave cavity를 이용한 플라즈마 발생장치를 기체크로마토그라프에 연결하여 원자발광 검출기로 사용하였다. 이 장치를 이용하여 몇 가지 원소에 대한 검출한계를 결정하였다. 브롬과 황에 대한 검출한계는 각각 0.46 pg/s 와 0.51 ng/s였으며, 운반기체의 유량이 10~20 mL/min에서 안정한 플라즈마를 얻을 수 있었다.

  • PDF

가스절연개폐장치용 UHF 부분방전검출장치의 새로운 감도 측정방법 (A Novel Sensitivity Verification Method for the UHF Partial Discharge Detection System in Gas Insulated Switchgear (GIS))

  • 구선근;박기준;윤진열
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.450-455
    • /
    • 2001
  • We proposed a new sensitivity verification method for the UHF partial discharge(PD) detection system. Initially, we measure the UHF power induced by 5 pC PD which takes place near UHF sensor. Subsequently, we inject the swept UHF signal from a network analyzer into the GIS and measure the attenuation of the signal along the 71S Both the UHF power by 5 pC PD and the attenuation make it possible to verify the sensitivity and spatial coverage of the PD detection system. This method doesn\`t require the calibration of injected pulse type UHF signal into the GIS and makes us precisely measure the attenuation in frequency domain.

  • PDF

식품 중 다환방향족탄화수소 분석법 연구 (A study on analytical methods for polycyclic aromatic hydrocarbons in foods)

  • 김용연;신한승
    • 식품과학과 산업
    • /
    • 제55권1호
    • /
    • pp.45-57
    • /
    • 2022
  • This study was proceeded the analytical methods using various analytical instruments for polycyclic aromatic hydrocarbons (PAHs) in food products. Various analytical methods were developed to determine levels of PAHs including benzo[a]pyrene, benzo[a]anthracene, benzo[b]fluoranthene, and chrysene formed in various food products using gas chromatography-mass spectrometry (GC-MS), enzyme-linked immunosorbent assay (ELISA) and raman spectroscopy. Recently, the rapid on-site response for the detection of hazardous substances in food aims to develop an onsite rapid detection of a simplified technical analysis method to reduce the time and cost required for analysis of PAHs. Current PAHs detection methods have been reviewed along with new raman spectroscopy analytical method.

nfrared Weak-lensing Detection of an Emerging Galaxy Cluster SpARCSJ1049+56 at z=1.71

  • Finner, Kyle;Jee, Myungkook
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.29.4-29.4
    • /
    • 2020
  • Structure in the universe forms hierarchically with the small scales forming first and merging into larger scales. Galaxy clusters are at the pinnacle of the formation process. Peering far into the universe, we can observe galaxy clusters early in their evolution. SpARCSJ1049+56 is a galaxy cluster located at a redshift of 1.71. It has been shown to be rich in cluster galaxies, to have intense star formation, and to have a significant amount of molecular gas. Through careful control of systematics, we detected the weak-lensing signal from this distant galaxy cluster. I will present our HST infrared weak-lensing detection of the cluster with a focus on the method. Our lensing analysis found that the cluster is massive and is rare in a LambdaCDM universe. I will also present the Chandra X-ray discovery of cold gas coincident with the intense star formation and discuss the implications of the detection.

  • PDF

NDIR 방법을 이용한 복합 가스 측정 시스템 (Composite Gas Measurement System using NDIR Method)

  • 어익수
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.624-629
    • /
    • 2018
  • 본 논문은 NDIR(Non Dispersive Infra Red) 방식을 적용하여 $CO_2$$CH_4$의 두 가지 가스를 하나의 휴대용 장치에서 측정이 가능하도록 제작된 복합 가스 측정 장치에 대한 연구이다. 측정 장치의 구성은 적외선램프에서 적외선이 방출되면 방출된 파장이 광학창을 거치면서 흡수로 인하여 빛이 줄어들게 되고 이 감소량(흡수도)을 검출기에서 검출하고 이를 전기적 신호로 변환 증폭하여(3.5V~6V) 정확한 측정이 가능함을 보여준다. 기존의 Single Sensor 방식은 적외선에서 특수파장을 흡수하여 상대 측정량을 검출하는 방식으로 가스의 경우 $4.26{\mu}m$파장의 빛만을 검출하여 측정하는 방식으로 센서의 값을 보정할 수 있는 기준센서가 없어 오차가 발생하는 문제가 발생하였다. 본 연구에 적용된 Dual Sensor 방식은 다른 가스의 영향을 받지 않는 $3.91{\mu}m$의 기준치와 가스의 $4.26{\mu}m$의 두 파장을 검출하여 비교측정 함으로써 오차가 적어 신뢰도가 높은 방식으로, 휴대형으로 소형화하여 저 전력화가 가능하며, $CO_2$$CH_4$의 2가지 가스농도를 복합적으로 측정 할 수 있다는 특징이 있다. 측정 범위는 $CO_2$의 경우 0ppm~5,000ppm이고 $CH_4$의 경우는 0~5%의 부피 농도로 실내 공기량 1,000ppm을 측정 할 수 있도록 제작되어 휴대용이나 주택의 Home automation과 연동하여 소화연동이 가능함으로 화재예방에 매우 효과적일 것으로 확인하였다.

Natural gas hydrate occurrence and detection in the Sea of Okhotsk

  • 진영근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.47-49
    • /
    • 2006
  • The Sea of Okhotsk is the unique area providing the highest methane production rate of the northern hemisphere. The area of focused fluid venting offshore the NE Sakhalin continental slope was investigated during the CHAOS (Hydro-Carbon Hydrate Accumulations in the Okhotsk Sea) expeditions onboard of RV "Akademik Lavrentyev" In 2003, 2005 and 2006. The International Research Project CHAOS (Russia-Korea-Japan) aimed at the study of gas hydrate formation processes associated with the fluid venting in the Sea of Okhotsk. Several new gas hydrate accumulations were discovered during the cruise. Hydrate-associated structures have been named as KOPRI, VNIIOKeangeologia, POI and KIT (the names of cruise participant institutes) Some of hydrate-bearing cores contain big amount of gas hydrates: massive gas hydrate layers (up to 35cm thick) were recovered. The shallowest submarine gas hydrate accumulations in the world (at the depth less then 400m) were discovered during the cruise.

  • PDF

LNG 저장탱크용 작업안전 환경 센싱 모듈의 특성연구 (A Study on the Characteristics of the Work Safety Environment Sensing Module for LNG Storage Tanks)

  • 박병진;김민성
    • 한국멀티미디어학회논문지
    • /
    • 제25권2호
    • /
    • pp.189-196
    • /
    • 2022
  • We have developed an embedded based environment sensing module with high-resolution temperature, humidity and gas sensors to detect gas leakage under the condition of LNG injection. The developed sensing module have linearity with gas concentration. We have confirmed the developed sensing module could detect LNG gas concentration of 5 cmol/mol and 15 cmol/mol, which are gas concentration at risk of explosion. The response time of the developed module was fast within 8 seconds. Therefore it can be used to detect LNG gas leakage.