• Title/Summary/Keyword: Gas detection

Search Result 1,189, Processing Time 0.027 seconds

Comparative Evaluation between Administrative and Watershed Boundary in Carbon Sequestration Monitoring - Towards UN-REDD for Mt. Geum-gang of North Korea - (탄소 저장량 감시에서 배수구역과 행정구역의 비교 평가 - 금강산에 대한 UN-REDD 대응 차원에서 -)

  • Kim, Jun-Woo;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.5
    • /
    • pp.439-454
    • /
    • 2013
  • UN-REDD (United Nations programme on Reducing Emissions from Deforestation and forest Degradation) is currently being emerged as one of important mechanism to reduce carbon dioxide in relation to the deforestation. Although administrative boundary has already gained world-wide recognition as a typical method of monitoring unit in the process of GHG (Greenhouse Gas) reduction project, this approach did not provide a realistic evidence in the carbon sequestering monitoring in terms of UN-REDD; the meaningful comparison of land use patterns among watershed boundaries, interpretation for distribution trends of carbon density, calculation of opportunity cost, leakage management, etc. This research proposes a comparative evaluation framework in a more objective and quantitative way for carbon sequestering monitoring between administrative and watershed boundary approaches. Mt. Geumgang of North Korea was selected as a survey objective and an exhaustive and realistic comparison of carbon sequestration between the two approaches was conducted, based on change detection using TM satellite images. It was possible for drainage boundary approach to identify more detailed area-wide patterns of carbon distribution than traditional administrative one, such as estimations of state and trends, including historical trends, of land use / land cover and carbon density in the Mt. Geumgang. The distinctive changing trends in terms of carbon sequestration were specifically identified over the watershed boundary from 4.0% to 34.8% while less than 1% difference was observed in the administrative boundaries, which were resulting in almost 21-22%. It is anticipated that this research output could be used as a valuable reference to support more scientific and objective decision-making in introducing watershed boundary as carbon sequestering monitoring unit.

Domestic Efforts for SFCL Application and Hybrid SFCL (국내 초전도 한류기 요구와 하이브리드 초전도 한류기)

  • Hyun, O.B.;Kim, H.R.;Yim, Y.S.;Sim, J.;Park, K.B.;Oh, I.S.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • We present domestic efforts for superconducting fault current limiter (SFCL) application in the Korea Electric Power Corporation (KEPCO) grid and pending points at issue. KEPCO's decision to upgrade the 154 kV/22.9 kV main transformer from 60 MVA to 100 MVA cast a problem of high fault current in the 22.9 kV distribution lines. The grid planners supported adopting an SFCL to control the fault current. This environment friendly to SFCL application must be highly dependent upon the successful development of SFCL having specifications that domestic utility required. The required conditions are (1) small size of not greater than twice of 22.9 kV gas insulated switch-gear (GIS), (2) sustainability of current limitation without the line breaking by circuit breakers (CB) for maximum 1.5 seconds. Also, optionally, recommended is (3) the reclosing capability. Conventional resistive SFCLs do not meet (1) $\sim$ (3) all together. A hybrid SFCL is an excellent solution to meet the conditions. The hybrid SFCL consists of HTS SFCL components for fault detection and line commutation, a fast switch (FS) to break the primary path, and a limiter. This characteristic structure not only enables excellent current limiting performances and the reclosing capability, but also allows drastic reduction of HTS volume and small size of the cryostat, resulting in economic feasibility and compactness of the equipment. External current limiter also enables long term limitation since it is far less sensitive to heat generation than HTS. Semi-active operation is another advantage of the hybrid structure. We will discuss more pending points at issues such as maintenance-free long term operation, small size to accommodate the in-house substation, passive and active control, back-up plans, diagnosis, and so on.

  • PDF

Comparative Analysis between Direct-reading Meter of PID and GC-FID using the Active Type Air Sampler for VOCs Measurement (직독식 측정기 PID와 능동식 시료채취기에 의한 GC-FID 정량분석법의 VOCs 농도 비교 연구)

  • Yeo, Jin-Hee;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.301-306
    • /
    • 2016
  • Objectives: Direct-reading instrument(Photoionization detectors, PID) and quantitative analysis using active type air sampling (Gas chromatography-flame ionization detector, GC-FID) were tested to evaluate their ability to detect volatile organic compounds(VOCs) in a semiconductor manufacturing plant. Methods: The organic compounds used were acetone and ethanol which are normally used as cleaning solutions in the semiconductor manufacturing. The evaluation was based on the preparation of test solutions of known acetone and ethanol concentration in a chamber($600{\times}600{\times}1150mm$). Samples were prepared that would be equivalent to 5~100 ppm for acetone and 10~ 200 ppm ethanol. GC-FID and PID were evaluated simultaneously. Quantitative analysis was performed after sampling and the direct-reading instrument was checked using real-time data logging. Results: Positive correlations between PID and GC-FID were found for acetone and ethanol at 0.04~2.4% for acetone(TLV: 500 ppm) and 0.1~8.3% for ethanol(TLV: 1000 ppm). When the sampling time was 15 min, concentration of test solution was the most similar between measurement methods. However, the longer the sampling time, the less similar the results. PID and GC-FID had similar exposure patterns. Conclusions: The results indicate that PID and GC-FID have similar exposure pattern and positive correlation for detection of acetone and ethanol. Therefore, PID can be used for exposure monitoring for VOCs in the semiconductor manufacturing industry. This study has significance in that it validates measuring occupational exposure using a portable device.

A Survey on Benzo(a)pyrene Contamination in Amomum Tsao-ko Fruit of Medicinal Herbs (유통 한약재 초과(草果) 중 벤조피렌 오염실태 조사)

  • Whang, Kyoung-Hwa;Yeom, Mi-Sook;Lee, Hee-Jeong;Jo, A-Reum;Choi, Eun-Jeong;Heo, Myong-Je;Kwon, Mun-Ju
    • Korean Journal of Pharmacognosy
    • /
    • v.51 no.2
    • /
    • pp.146-150
    • /
    • 2020
  • Amomum Tsao-ko used as a traditional oriental herbal medicine, is indigenous to several Asia countries. This study was carried out to investigate the contamination by Benzo(a)pyrene in Amomum Tsao-ko Fruit of Medicinal Herbs. 20 samples of Amomum Tsao-ko Fruit were evaluated for the Benzo(a)pyrene contamination. They were analyzed for Benzo(a)pyrene using high-performance liquid chromatogrphy(HPLC)-fluorescence detection and the positive samples were confirmed using gas chromatography tandem mass spectrometry. The levels of Benzo(a)pyrene were from 9.2 to 95.5 ㎍/kg and the average was 40.6 ㎍/kg. There are no Benzo(a)pyrene standards for Amomum Tsao-ko Fruit of Medicinal Herbs. These data will be used as a basic data for the future legislation on the regulation and control of benzo(a)pyrene of Amomum Tsao-ko Fruit of Medicinal Herbs.

Reduced sulfur gas loss in the bag sampling procedure - Comparison by calibration slope values (악취황 성분의 채취와 샘플백 내부의 시료 유실율 비교: 검량선의 기울기를 이용한 평가)

  • Kim, K.H.;Choi, Y.J.;Ahn, J.W.
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.338-343
    • /
    • 2005
  • In this work, sample loss of reduced sulfur compounds (RSC) was investigated with respect to bag sampling techniques. For comparison purpose, calibration slopes were obtained by analyzing standards prepared by 'within syringe dilution' (WSD) method against those made either by 'Tedlar bag dilution' (TBD) or by 'polyester aluminum bag dilution' (PBD) method. The results indicated that the recovery rate of TBD showed the mean values of about 87%, while those of PBD about 77%. Despite the fact that sample loss is inevitable, precise sampling of reduced sulfur compounds may still be possible, if one acknowledges and be prepared for such loss rates of bag sampling methods.

The Extraction and Derivatization of Organotins in Water Sample by Gas Chromatograph/Mass Spectrometer (기체크로마토그래프/질량분석기에 의한 물시료 중 Organotin의 추출 및 유도체 반응에 관한 연구)

  • Hong, Jee-Eun;Lee, Kang-Jin;Pyo, Hee Soo;Park, Song-Ja;Lee, Won
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.636-645
    • /
    • 2000
  • A method is described for the determination of organotins in water samples by GC/MS. Optimized derivatization methods for ethylation and hydrogenation of organotins were surveyed according to various reaction conditions such as time, pH and concentration of reagents. The organotins were extracted with n-hexane in presence of 0.1% tropolone and hydrogenated with sodium borohydride. Extraction recoveries of organotins with hydrogenation were in the range of 61-112%. After ethylation, organotins in water samples were extracted by liquid-liquid extraction (LLE) and solid-phase extraction (SPE). Using LLE, extraction recoveries were in the range of 74-113%. The recoveries ranged from 61-97% in the case of SPE with styrene-divinylbenzene copolymers. Method detection limits of hydrogenated and ethylated organotins ranged from 0.05 to 0.5 ng/ml and from 0.02 to 0.05 ng/ml, respectively.

  • PDF

Organic Material Analysis of a Lacquered Wooden Sheath of Long Sword with Ring Pommel Excavated in Imdang Ancient Tomb (경산 임당고분 출토 철제 고리자루칼 칠의 유기물 분석)

  • Park, Jongseo;Cho, Ha-nui;Lee, Jae-sung
    • Journal of Conservation Science
    • /
    • v.34 no.5
    • /
    • pp.369-377
    • /
    • 2018
  • In order to examine the constituents and weathered state of a lacquer specimen, analysis of the organic materials was conducted using py/GC/MS(pyrolysis-gas chromatography-mass spectrometry). The samples were obtained from the lacquered wooden sheath of a long ring-pommel sword excavated in the Imdang No.1 ancient tomb constructed around the Proto-Three Kingdoms period. In direct py/GC/MS, the sample and the dried Asian lacquer showed similar chromatograms, while the characteristic compounds of Asian lacquer such as 1,2-dimethoxy-3-pentadecylbenzene were observed in THM(thermally assisted hydrolysis and methylation)-py/GC/MS. In addition, compounds like dimethyl nonanedioate, which presumably originated from drying oil, were also detected. Furthermore, the detection of oxidized catechols in considerable amount indicated that the degradation of lacquer is estimated to result from the oxidation of urushiol. Therefore, it is suggested that the lacquered wooden sheath was prepared using Asian lacquer and drying oil, and that the lacquer layer was considerably oxidized over the long burial time.

Qualitative Analysis of the Major Constituents in Traditional Oriental Prescription Bang-poong-tong-sung-san by Liquid Chromatography/Ultraviolet Detector/Ion-Trap Time-of-Flight Mass Spectrometry

  • Eom, Han Young;Kim, Hyung-Seung;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.1
    • /
    • pp.24-29
    • /
    • 2014
  • An advanced and reliable high performance liquid chromatography (HPLC)/ultraviolet detector (UV)/ion-trap time-of-flight (IT-TOF) mass spectrometry was developed for the simultaneous quantification of 19 marker compounds in Bang-poong-tong-sung-san (BPTS), a traditional oriental prescription. Various parameters affecting HPLC separation and IT-TOF detection were investigated, and optimized conditions were identified. The separation was achieved on a Capcell PAK C18 column ($1.5mm{\times}250mm$, $5{\mu}m$ particle size) using a gradient elution of acetonitrile and water containing 0.1% formic acid at a flow rate of 0.1 mL/min. The column temperature was maintained at $40^{\circ}C$ and the injection volume was $2{\mu}L$. IT-TOF system was equipped with an electrospray ion source (ESI) operating in positive or negative ion mode. The optimized electrospray ionization parameters were as follows: ion spray voltage, +4.5 kV (positive ion mode), or -3.5 kV (negative ion mode); drying gas ($N_2$), 1.5 L/min; heat block temperature, $200^{\circ}C$. Automatic $MS^n$ (n = 1~3) analyses were carried out to obtain structural information of analytes. Elemental compositions and their mass errors were calculated based on their accurate masses obtained from a formula predictor software. The marker compounds in BPTS were identified by comparisons between $MS^n$ spectra from standards and those from extracts. Moreover, the libraries of $MS^2$ and $MS^3$ spectra and accurate masses of parent and fragment ions for marker compounds were constructed. The developed method was successfully applied to the BPTS extracts and identified 17 out of 19 marker compounds in the BPTS extracts.

Photocatalytic Degradation of Chlorothalonil using TiO2 Supported in Matrices (TiO2 고정화 지지체를 이용한 Chlorothalonil의 광촉매분해)

  • Kim, Jong-Hyang;Nam, Chon-Dong;Kim, Byung-Kwan
    • Applied Chemistry for Engineering
    • /
    • v.7 no.4
    • /
    • pp.750-756
    • /
    • 1996
  • $TiO_2$ was dispersed in zeolite and glass filter by soaking them in isopropanol solution of titanium tetraisopropoxide and drying in the air, followed by calcination at $500^{\circ}C$. The analysis of chlorothalnoil was carried out by gas chromatograph with an electron capture detector. Chlorothalnoil was degraded photocatalytically over the matrix-supported $TiO_2$ efficiently and could be completely photodegraded after 3hrs. Production were 5.0ppm of $Cl^-$ for $TiO_2$ supported zeolite, 7.5ppm of $Cl^-$ for $TiO_2$ supported glass filter and 2.0ppm of $Cl^-$ for $TiO_2$ powder. But, $CN^-$ was lower than the detection limit irrespective of matrices.

  • PDF

Development of Decision Model and Management System to minimize Pavement Utility Cut for Road Facility (도로시설 재굴착 방지를 위한 의사결정모델 및 관리시스템 개발)

  • Cho, Jin-Young;Jang, Oun-Sung;Lee, Min-Jae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.4
    • /
    • pp.164-171
    • /
    • 2013
  • In urban planning, road facility is used not only for the transportation purpose but also for the utility line space purpose such as electrical, gas, tele communication, heating, water, sewer, and so on. However, since these utilities are built by many different groups, it becomes very difficult to communicate each other. Delay in one party can cause another party's schedule delay but they don't commuicate often. Also, some delay in utility work can cause frequent pavement cut. And, this will impact on construction cost, schedule delay, low quality, user complain and cost. This study developed spatiotemporal decision model to prevent prequent utility cut for mega project such as new urban development project. In addition, this study developed utility cut management system to manage utility cut schedule under pavement. Finally, developed system was applied to new urban development project and verified there effectiveness.