• 제목/요약/키워드: Gas Turbine-Generator

검색결과 207건 처리시간 0.085초

수중방사소음 저감을 위한 함정용 개스터빈 발전기의 순음 저감 분석 (Analysis of Reducing Tonal Noise of the Gas Turbine Generator in order to Reduce Underwater Radiated Noise of a Naval Vessel)

  • 한형석;최기용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.155-162
    • /
    • 2009
  • Because the tonal sound of the underwater noise in a naval vessel can be identified from the sub-marine of the enemy, it should be reduced sufficiently. This kind of the noise usually comes from the structure-borne noise of the onboard machine and transfers to the sea through the hull of the ship. The vibration at the high frequency can be reduced sufficiently with damping material. In this paper, the damping coefficient of the steel plate with damping sheet is evaluated by experiment. Using these evaluated properties, the numerical analysis is performed in order to evaluate how much vibration of the generator can be reduced applying damping sheet on the encloser and base of it.

  • PDF

가스터빈 발전기 회전자 권선의 절연상태 평가 (Assessment of Rotor Winding Insulation Condition for Gas Turbine Generators)

  • 김희동;김병래
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1818-1821
    • /
    • 2008
  • Several off-line diagnostic tests which include the insulation resistance(IR), polarization index(PI), low-voltage AC, and recurrent surge oscillograph(RSO) tests were performed to assess the condition of generator rotor windings. The low-voltage AC and the RSO tests were performed on the gas turbine generator rotor winding to detect shorted turns. Before intentionally applying artificial shorted faults, it was confirmed by the low voltage AC and the RSO tests that the winding was in sound condition. For simulated shorted rotor winding turns, the RSO test detected the fault in the winding. The RSO test was capable of identifying the number and pole location of the shorted turns for a number of simulated shorted coils.

수중방사소음 저감을 위한 함정용 개스터빈 발전기의 순음 저감 분석 (Analysis of Reducing Tonal Noise of the Gas Turbine Generator in order to Reduce Underwater Radiated Noise of a Naval Vessel)

  • 한형석;최기용
    • 한국소음진동공학회논문집
    • /
    • 제19권12호
    • /
    • pp.1329-1337
    • /
    • 2009
  • Because the tonal sound of the underwater noise in a naval vessel can be identified from the sub-marine of the enemy, it should be reduced sufficiently. This kind of the noise usually comes from the structure-borne noise of the onboard machine and transfers to the sea through the hull of the ship. The vibration at the high frequency can be reduced sufficiently with damping material. In this paper, the damping coefficient of the steel plate with damping sheet is evaluated by experiment. Using these evaluated properties, the numerical analysis is performed in order to evaluate how much vibration of the generator can be reduced applying damping sheet on the encloser and base of it.

발전기 회전자 권선의 운전중 층간단락 탐지 (On-Line Detection of Shorted Turn in Generator Rotor Windings)

  • 김희동;이영준;박종정;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권3호
    • /
    • pp.192-199
    • /
    • 1999
  • During start up and shut down, the generator is rotating at a low speed and copper dusts cause arcing between the turns in the slot. Shorted turns occurred primarily by the movement of these copper dusts between individual windings in the generator rotor. Detection of shorted turns was performed in five gas turbine generators in two combined cycle power plants. Two types of permanent and temporary flux probes were used in this paper. These flux probes have been used to develop a methodology for detecting shorted turns in an operating generator's rotor. The flux probes sense the rotor winding slot leakage flux and produce a voltage proportional to the rate of change of the flux. This pattern of flux variation is the signature unique to each rotor winding. An appropriate waveform analysis technique canidentify the pole location, the slot number, and the number of shorted turns within each slot. Shorted turns in field winding of gas turbine generator(125.7 MVA) were detected to twelve turns on al total 190 turns.

  • PDF

마이크로 가스터빈 발전시스템의 운전성능 분석 (Analysis of Operation Performance of a Micro Gas Turbine Generator System)

  • 이종준;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제8권5호
    • /
    • pp.13-21
    • /
    • 2005
  • This study aims to analyze operating performance of a micro gas turbine with the aid of detailed measurements of various system parameters. In addition to embedded measurements, parameters such as exhaust temperatures, engine inlet temperatures and fuel flow rates are measured. Variations in measured data and estimated performance parameters are analyzed. Those data are processed to calculate losses along the power transmission line and the net gas turbine performance (power and efficiency based on the gas turbine shaft end) is isolated from the overall system performance. A method to estimate characteristic parameters such as component efficiencies, based on the comparison between measured and predicted performance data, is suggested and exemplified for the full load condition.

마이크로 가스터빈 발전시스템의 운전성능 분석 (Analysis of Operation Performance of a Micro Gas Turbine Generator System)

  • 이종준;김동섭
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.132-139
    • /
    • 2004
  • This study aims to analyze operating performance of a micro gas turbine with the aid of detailed measurements of various system parameters. In addition to embedded measurements, parameters such as exhaust temperatures, engine inlet temperatures and fuel flow rates are measured Variations in measured data and estimated performance parameters are analyzed. Those data are processed to calculate losses along the power transmission line and the net gas turbine performance (power and efficiency based on the gas turbine shaft end) is isolated from the overall system performance. On the basis of the measured data, analytical approach is tried to estimate design characteristic and performance parameters such as component efficiencies and unmeasured temperatures.

  • PDF

충격파관을 이용한 DISK형 MHD발전기에 관한 연구 (A Study on the Disk Type MHD Generator Using a Shock Tube)

  • 배철오;신명철;김윤식;길경석
    • 한국정보통신학회논문지
    • /
    • 제3권2호
    • /
    • pp.447-453
    • /
    • 1999
  • In MHD power generation system, enthalpy of the working gas is convened to electric power directly through expansion in generator channel. It means that electric power can be generated without a moving mechanical linkage such as turbine blades. The principle of MHD generation is based on Faraday'law of induction that eletromotive force(u$\times$B) is generated when the working gas of velocity u flows a channel in which magnetic field of strength(B) exists. In this paper, helium gas seeded with cesium is used as working gas. There are two types of generator in MHD generation; linear type faraday and disk type hall generator. Rogowski coils having the bandwidth of the 100(Hz) ~ 20(kHz) were used for measuring current flowing MHD disk channel. Optimum load resistor value of the MHD generator studied was 2.5[$\Omega$]. Disk type hall generator's generation performance is the main target of this paper, which superiors to linear type Faraday generator in many points. Isentropic efficiency and enthalpy extraction rate of disk type shock tube driven hall generator is discussed here.

  • PDF

터빈 결합 환경의 가스발생기 동적 연소 특성 (Combustion Dynamics of a Gas Generator Assembled with a Turbine Manifold)

  • 서성현;임병직;안규복;이광진;김종규;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제30회 춘계학술대회논문집
    • /
    • pp.121-124
    • /
    • 2008
  • 본 논문에서 연료 과농 가스발생기의 동적 연소 특성을 수록하였다. 연소실과 추진제 매니폴드 내에서 발생하는 압력 섭동을 계측하여 데이터 분석을 실시하였다. 단독 연소 시험에서는 연소압에 관계없이 연소가 안정적으로 이루어졌으나 터빈 매니폴드 장착의 경우, 산소 임계 압력에 해당하는 50 bar이하의 저압 조건에서 저주파 연소 불안정이 발생하는 것을 확인하였다. 이는 연소실 특성 길이 증가에 의한 축방향 연소 불안정으로 여겨지며, 연소압 증가에 따라 압력 섭동이 증가함을 확인하였다.

  • PDF

충돌형 분사기 형태의 액체로켓엔진용 가스발생기 연소성능시험 (Combustion Performance Tests of Fuel-Rich Gas Generator for Liquid Rocket Engine Using an Impinging Injector)

  • 한영민;김승한;문일윤;김홍집;김종규;설우석;이수용;권순탁;이창진
    • 한국추진공학회지
    • /
    • 제8권2호
    • /
    • pp.10-17
    • /
    • 2004
  • 본 논문에서는 액체로켓엔진용 160 kW급 터보펌프의 터빈을 구동하고, 액체산소와 케로신을 추진제로 사용하는 연료 과잉 가스발생기의 설계점 연소성능시험 결과에 대해 논의하였다. 충돌형 F-O-F 분사기로 구성된 헤드부, 물냉각 채널 연소실, torch igniter, turbulence ring 그리고 측정 링을 갖는 가스발생기에 대해 기술하였고, 설계점에서의 연소시험 및 turbulence ring 장착여부. 연소실 길이 변화에 따른 연소시험의 결과들에 대해 기술하였다. 연소시험 결과 가스발생기는 설계점에서 안정된 작동성을 보여주었고. 연소압력 및 온도 등의 성능은 예측치에 근접하는 결과였다. Turbulence ring은 출구에서의 가스온도를 균일하게 분포시켜 효과적인 혼합 장치임을 보여 주었고, 4∼6msec 정도에서의 연소가스 잔류시간은 연소효율에 큰 영향을 주지 않았다. 가스발생기 출구에서의 온도는 공급되는 추진제의 O/F ratio에 따라 매우 민감하게 변화하였다.

Gas Generator를 이용한 액체 로켓 터보펌프 엔진 시스템의 동특성 해석

  • 정영석;임석희;이한주;조기주;오승협
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2003년도 한국우주과학회보 제12권2호
    • /
    • pp.88-88
    • /
    • 2003
  • 로켓 엔진 시스템에는 가압가스로 추진제를 엔진으로 공급하는 가압 시스템과 터보펌프를 이용해 엔진으로 고압의 추진제를 공급하는 터보펌프 시스템으로 나눌 수 있으며 터보펌프 시스템은 다시 Gas Generator를 이용하는 개방형 엔진과 Prebumer를 이용한 폐쇄형 엔진인 다단 엔진으로 구분할 수 있다. 로켓의 엔진 시스템은 Turbine, Turbopump, Gas Generator, Thrust Chamber, Tube, Valve, Propellant Tank 등 각 구성품 간에 서로 상호간섭이 매우 심한 공정이다 로켓 엔진 시스템은 이와 같은 상호간섭에 의해 추력 제어 및 혼합비 제어, 추진제 소진 제어 적용 시 정확하고 강인한 제어를 수행하여야 한다. 이를 위해 정확한 동특성 모델을 구축하는 것이 중요하며 모델을 통해 적절한 제어 시스템을 선택하여야 한다. 그러나 현재 국내에는 이에 대한 연구가 미미하며 해외의 경우 로켓은 특수 분야에 속함으로 공개되어 있지 않다. 로켓에 대한 개발 연구에 있어서는 위와 같은 작업이 선행되어야 하며 이에 대한 선행 연구로 한국항공우주연구원에서 Gas Generator를 이용한 개방형 터보펌프 엔진 시스템에 대한 연구를 진행하고 있다. 본 논문에서는 Gas Generator를 이용한 개방형 터보펌프 엔진시스템에 대한 동특성 모델을 구성하였다. 배관부, 터빈, 펌프, 밸브, Gas Generator, 재생냉각, 추력연소실 등 엔진 시스템을 구성하는 구성품에 대한 동특성 모델을 구성하였으며 이를 matlab의 simulink를 통해 각 구성품을 연결하여 최종 엔진시스템의 동특성 모델을 구성하였다. 구성된 동특성 모델을 통해 각종 변화(추진제 밀도 변화, 추력 변화, 혼합비 변화 등)에 대한 엔진 시스템 변화를 예측하여 정확한 엔진 시스템에 대한 이해를 넓혔으며 추력 제어 및 혼합비, 추진제 소진 제어를 최적으로 할 수 있는 제어 시스템 구축을 위한 기초 자료로 이용할 수 있을 것이다.

  • PDF