• Title/Summary/Keyword: Gas Combustion

Search Result 3,050, Processing Time 0.027 seconds

Development of Adsorbent for Vapor Phase Elemental Mercury and Study of Adsorption Characteristics (증기상 원소수은의 흡착제 개발 및 흡착특성 연구)

  • Cho, Namjun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.1-6
    • /
    • 2021
  • Mercury, once released, is not destroyed but accumulates and circulates in the natural environment, causing serious harm to ecosystems and human health. In the United States, sulfur-impregnated activated carbon is being considered for the removal of vapor mercury from the flue gas of coal-fired power plants, which accounts for about 32 % of the anthropogenic emissions of mercury. In this study, a high-efficiency porous mercury adsorption material was developed to reduce the mercury vapor in the exhaust gas of coal combustion facilities, and the mercury adsorption characteristics of the material were investigated. As a result of the investigation of the vapor mercury adsorption capacity at 30℃, the silica nanotube MCM-41 was only about 35 % compared to the activated carbon Darco FGD commercially used for mercury adsorption, but it increased to 133 % when impregnated with 1.5 % sulfur. In addition, the furnace fly ash recovered from the waste copper regeneration process showed an efficiency of 523 %. Furthermore, the adsorption capacity was investigated at temperatures of 30 ℃, 80 ℃, and 120 ℃, and the best adsorption performance was found to be 80 ℃. MCM-41 is a silica nanotube that can be reused many times due to its rigid structure and has additional advantages, including no possibility of fire due to the formation of hot spots, which is a concern when using activated carbon.

Greenhouse Gas Emission Reduction and Economic Benefit Evaluation of Carbon Mineralization Technology using CFBC Ash (순환유동층 석탄재를 이용한 탄소광물화 기술의 온실가스 배출 저감량 및 경제성 분석)

  • Jung, Euntae;Kim, Jeongyun
    • Resources Recycling
    • /
    • v.31 no.3
    • /
    • pp.40-52
    • /
    • 2022
  • This study analyzed the amount of carbon dioxide reduction and economic benefits of detailed processes of CO2 6,000 tons plant facilities with mineral carbonation technology using carbon dioxide and coal materials emitted from domestic circulating fluidized bed combustion power plants. Coal ash reacted with carbon dioxide through carbon mineralization facilities is produced as a complex carbonate and used as a construction material, accompanied by a greenhouse gas reduction. In addition, it is possible to generate profits from the sales of complex carbonates and carbon credits produced in the process. The actual carbon dioxide reduction per ton of complex carbonate production was calculated as 45.8 kgCO2eq, and the annual carbon dioxide reduction was calculated as 805.3 tonCO2, and the benefit-cost ratio (B/C Ratio) is 1.04, the internal rate return (IRR) is 10.65 % and the net present value (NPV) is KRW 24,713,465 won, which is considered economical. Carbon mineralization technology is one of the best solutions to reduce carbon dioxide considering future carbon dioxide reduction and economic potential.

A Study on a Method for Fire Suppression in a Central Area inside the Roof of a Wooden Cultural Property using a Gas Extinguishing Apparatus (가스소화설비를 이용한 목조 문화재 적심부 화재진압 방법에 관한 연구)

  • Kim, Hyunsung;Kim, Byung Sean;Cho, Woncheol;Lim, Yun Mook
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.65-71
    • /
    • 2010
  • This study was conducted to provide a method for fire suppression in a central area inside the roof of a wooden cultural property using a gas extinguishing apparatus, which is used as one of fire suppression methods with view to preventing valuable wooden properties inherited from ancestors from being destructed by fire. For a wooden property, it is very difficult to suppress fire when combustion spreads to a central area inside its roof, so it is impossible to put out a fire without destructing it. Such a fire fighting apparatus as a sprinkler, etc., installed in modern structures, is very effective, but the possibility of damaging a cultural property is highly probable after installment and operation, which leads to its low adaptability to a wooden property. Thus, the necessity of developing a fire suppress ion apparatus was raised to minimize the said problem and to obtain the desired results, and the need of making a plan on the installment was also raised based on the results of a test whose validity was proven. The central area inside a roof is a traditional - architectural style which is found in Korean wooden structures only, so it is impossible to discover similar cases in foreign countries. For this reason, this study was conducted to verify the effectiveness by developing a fixed fire suppression apparatus designed considering the speed and effectiveness in fire suppression. This study was sequentially carried out in the following steps. First, a frame for this study was made and the specific plan on a fire suppression method was established. Then, a fire suppression apparatus was installed. In the first step, the effectiveness for fire suppression was tested by installing valve open - punched - main water pores, and in the second step, the same effectiveness was tested by valve opened - punched - injection ports. For a wooden property similar to "Sungnyemun"(Gate of Exalted Ceremonies), its central area of the roof decides whether the fire suppression is successful or not, so the opinions on how to put out a fire were presented in this study, and thus the objective data to establish a method on fire suppression in a wooden structure(cultural property) was secured. Lastly, a scientific verification in the effectiveness for fire suppression measures was presented by installing a gas - fixed fire suppression apparatus.

  • PDF

Study on the Indoor-Outdoor $NO_2$ Levels and Related Factors in Urban Apartments (도시아파트의 실내외 $NO_2$ 농도와 관련요인에 관한 연구)

  • Suh, Byung-Seong;Kim, Sung-Hwan;Kim, In-Shik;Hur, Yun-Young;Do, Sou-Young;Kim, Jung-Man;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.609-622
    • /
    • 1997
  • Nitrogen dioxide $(NO_2)$ has been regarded as one of the main elements among air pollutants, and we measured $NO_2$ levels of near gas range, kitchen, living room and outdoor on 489 apartments in Pusan area. $NO_2$ were sampled by using Palmes tubes (diffusion tube sampler) during August 16-25, 1995 (summer) and January 15-29, 1996 (winter), respectively. Authors wanted to know comparison of $NO_2$ levels in summer and winter, $NO_2$ levels categorized by variables, and variables affected to $NO_2$ levels. According to this study, we conducted to establish the degree of indoor-outdoor air pollution of urban apartments in Korea and methods to reduce indoor air pollution. The results of this study were summarized as follows: 1) Mean $NO_2$ levels of near gas range, kitchen, living room, and outdoor were $25.9{\pm}10.0ppb,\;23.3{\pm}8.0ppb,\;19.9{\pm}6.1ppb,\;and\;19.0{\pm}6.0ppb$ in summer, and $34.5{\pm}16.8ppb,\;28.2{\pm}13.4ppb,\;25.3{\pm}12.5ppb,\;21.8{\pm}9.8ppb$ in winter, respectively. 2) Mean $NO_2$ levels according to the floor levels were not significantly different in summer, and in winter, $NO_2$ levels were decreased as the floor levels were increasing, but those were increased above 16th floor. 3) Variables showing significant correlation(p<0.05) with $NO_2$ levels were as follows; Summer: floor level, family size, number of family during a meal, number using gas range during rice cooking per day, and natural ventilation. Winter: floor level, family size, number of person who have been respiratory disease in a house, number of family during a meal, total number of meals, and number using gas range during rice or side-dish cooking per day. 4) We suggest that the methods of reducing indoor $NO_2$ levels are ventilation during cooking, complete combustion, decreasing number and time of cooking, and substitution of fuels.

  • PDF

Nonthermal Plasma-assisted Diesel Reforming and Injection of the Reformed Gas into a Diesel Engine for Clean Combustion (디젤의 청정연소를 위한 저온 플라즈마 연료개질 및 개질가스의 디젤엔진 첨가에 관한 연구)

  • Kim, Seong-Soo;Chung, Soo-Hyun;Kim, Jin-Gul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.394-401
    • /
    • 2005
  • A nonthermal plasma-assisted fuel reformer was developed and the effects of operating variables on the performance of this reformer were studied. The $H_2$-rich reformed gas from the reformer was injected into a diesel engine under an idle condition and the effects of the amount of injected gas on the NO and soot reduction were investigated. It was found that with increasing electric power consumption, the degree of facility of ignition of the reforming reaction in the reformer could be enhanced. The performance of the reformer including $H_2$ concentration, $H_2$ recovery, and energy conversion was affected only by the O/C mole ratio. This was because the equilibrium reaction temperature was governed by the O/C mole ratio. With increasing O/C mole ratio, the $H_2$ recovery and energy conversion passed through the maximum values of 33.4% and 66%, respectively, at an O/C mole ratio between 1.2 and 1.5. The reason why the $H_2$ recovery and energy conversion increased with increasing O/C mole ratio when the O/C mole ratio was lower than $1.2{\sim}1.5$ appeared to be that the complete oxidation reaction occurred more enough with increasing O/C mole ratio in this low O/C mole ratio range and accordingly the reaction temperature increased. Whereas the reason why the $H_2$ recovery and energy conversion decreased with increasing O/C mole ratio when the O/C mole ratio was higher than $1.2{\sim}1.5$ appeared to be that the complete oxidation reaction was further advanced and the $H_2$ recovery and energy conversion decreased. As the weight ratio of reformed diesel to total diesel which entered the diesel engine was increased to $18.2{\sim}23.5%$, NO and soot reduction efficiencies increased and reached as values high as 68.5% and 23.5%, respectively.

Characterisitics of Redox Reaction of the Magnetite Powder Prepared by Hydrothermal Synthesis (수열합성법으로 합성된 마그네타이트 분말에 대한 산화.환원 특성)

  • Park, Sung Youl;Kang, Min Pil;Rhee, Young Woo;Nam, Sung Chan
    • Korean Chemical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.751-755
    • /
    • 2005
  • Carbon dioxide, included in the flue gas from the combustion of fossil fuel, was known as a representative green house gas and various removal and utilization technologies of it has been studied for the prevention of global warming. This study was performed as an effort to find out a method to reuse carbon dioxide separated from flue gas by magnetite powder. Magnetite powder was synthesized using various oxidizers and alkalinity controlled aqueous solutions of $FeSO_4{\cdot}7H_2O$ and NaOH at 50, 80, 90, $100^{\circ}C$ and analyzed by XRD and SEM. The analysis results showed that magnetite powder synthesized at higher alkalinity and temperature had crystalline spinel and cubic structure. The reduction by hydrogen and the oxidation by carbon dioxide of synthesized powder were studied by TGA. The results showed that magnetite powder synthesized at low alkalinity and temperature was non-cubical amorphous but crystalline and cubical at high alkalinity and temperature. Comparing magnetite powders synthesized using oxidants(air and oxygen) and nitrogen, magnetite powder using more oxygen containing oxidant synthesized more crystalline magnetite powder. The experimental results of redox reaction of the synthesized magnetite powder showed that the reduction by hydrogen and the oxidation by carbon dioxide were seldom observed below $400^{\circ}C$ and observed well at $500^{\circ}C$. Magnetite powder synthesized at $100^{\circ}C$ and alkalinity(molal concentration ratio of $FeSO_4{\cdot}7H_2O$ to NaOH) of 2.0 using $O_2$ showed the highest reduction of 27.15 wt% and oxidation of 26.73 wt%, especially at reaction temperature of $500^{\circ}C$.

Simultaneous Removal of NO and SO2 using Microbubble and Reducing Agent (마이크로버블과 환원제를 이용한 습식 NO 및 SO2의 동시제거)

  • Song, Dong Hun;Kang, Jo Hong;Park, Hyun Sic;Song, Hojun;Chung, Yongchul G.
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.341-349
    • /
    • 2021
  • In combustion facilities, the nitrogen and sulfur in fossil fuels react with oxygen to generate air pollutants such as nitrogen oxides (NOX) and sulfur oxides (SOX), which are harmful to the human body and cause environmental pollution. There are regulations worldwide to reduce NOX and SOX, and various technologies are being applied to meet these regulations. There are commercialized methods to reduce NOX and SOX emissions such as selective catalytic reduction (SCR), selective non-catalytic reduction (SNCR) and wet flue gas desulfurization (WFGD), but due to the disadvantages of these methods, many studies have been conducted to simultaneously remove NOX and SOX. However, even in the NOX and SOX simultaneous removal methods, there are problems with wastewater generation due to oxidants and absorbents, costs incurred due to the use of catalysts and electrolysis to activate specific oxidants, and the harmfulness of gas oxidants themselves. Therefore, in this research, microbubbles generated in a high-pressure disperser and reducing agents were used to reduce costs and facilitate wastewater treatment in order to compensate for the shortcomings of the NOX, SOX simultaneous treatment method. It was confirmed through image processing and ESR (electron spin resonance) analysis that the disperser generates real microbubbles. NOX and SOX removal tests according to temperature were also conducted using only microbubbles. In addition, the removal efficiencies of NOX and SOX are about 75% and 99% using a reducing agent and microbubbles to reduce wastewater. When a small amount of oxidizing agent was added to this microbubble system, both NOX and SOX removal rates achieved 99% or more. Based on these findings, it is expected that this suggested method will contribute to solving the cost and environmental problems associated with the wet oxidation removal method.

Time-Series Analysis and Estimation of Prospect Emissions and Prospected Reduction of Greenhouse Gas Emissions in Chungbuk (온실가스 배출량 시계열 분석과 전망 배출량 및 감축 감재량 추정 - 충북을 중심으로 -)

  • Jung, Okjin;Moon, Yun Seob;Youn, Daeok;Song, Hyunggyu
    • Journal of the Korean earth science society
    • /
    • v.43 no.1
    • /
    • pp.41-59
    • /
    • 2022
  • In accordance with the enactment of 'the Paris Agreement' in 2015 and 'the Framework Act on Carbon Neutrality and Green Growth for Response to the Climate Crisis' in 2021, each local government has set appropriate reduction target of greenhouse gas to achieve the nationally determined contribution (NDC, the reduction target of 40% compared to 2018) of greenhouse gas (GHG) emissions in 2030. In this study, the current distribution of GHG emissions was analyzed in a time series centered on the Chungbuk region for the period from 1990 to 2018, with the aim of reducing GHG emissions in Chungbuk by 2030 based on the 2030 NDC and scenario. In addition, the prospected reduction by 2030 was estimated considering the projected emissions according to Busines As Usual in order to achieve the target reduction of GHG emissions. Our results showed that GHG emissions in Chungbuk and Korea have been increasing since 1990 owing to population and economic growth. GHG emissions in 2018 in Chungbuk were very low (3.9 %) relative to the national value. Moreover, emissions from fuel combustion, such as cement and lime production, manufacturing and construction industries, and transportation industries, were the main sources. Furthermore, the 2030 target of GHG emission reduction in Chungbuk was set at 40.2% relative to the 2018 value, in accordance with the 2030 NDC and 2050 carbon-zero national scenario. Therefore, when projected emissions were considered, the prospected reduction to achieve the target reduction of GHG emissions was estimated to be 46.8% relative to 2018. The above results highlight the importance of meeting the prospected reduction of GHG emissions through reduction means in each sector to achieve the national and local GHG reduction target. In addition, to achieve the 2030 NDC and 2050 carbon zero, the country and each local government, including Chungbuk, need to estimate projected emissions by year, determine reduction targets and prospect reductions every year, and prepare specific means to reduce GHG emissions.

Air Pollution and Its Effects on E.N.T. Field (대기오염과 이비인후과)

  • 박인용
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.6-7
    • /
    • 1972
  • The air pollutants can be classified into the irritant gas and the asphixation gas, and the irritant gas is closely related to the otorhinolaryngological diseases. The common irritant gases are nitrogen oxides, sulfur oxides, hydrogen carbon compounds, and the potent and irritating PAN (peroxy acyl nitrate) which is secondarily liberated from photosynthesis. Those gases adhers to the mucous membrane to result in ulceration and secondary infection due to their potent oxidizing power. 1. Sulfur dioxide gas Sulfur dioxide gas has the typical characteristics of the air pollutants. Because of its high solubility it gets easily absorbed in the respiratory tract, when the symptoms and signs by irritation become manifested initially and later the resistance in the respiratory tract brings central about pulmonary edema and respiratory paralysis of origin. Chronic exposure to the gas leads to rhinitis, pharyngitis, laryngitis, and olfactory or gustatory disturbances. 2. Carbon monoxide Toxicity of carbon monoxide is due to its deprivation of the oxygen carrying capacity of the hemoglobin. The degree of the carbon monoxide intoxication varies according to its concentration and the duration of inhalation. It starts with headache, vertigo, nausea, vomiting and tinnitus, which can progress to respiratory difficulty, muscular laxity, syncope, and coma leading to death. 3. Nitrogen dioxide Nitrogen dioxide causes respiratory disturbances by formation of methemoglobin. In acute poisoning, it can cause pulmonary congestion, pulmonary edema, bronchitis, and pneumonia due to its strong irritation on the eyes and the nose. In chronic poisoning, it causes chronic pulmonary fibrosis and pulmonary edema. 4. Ozone It has offending irritating odor, and causes dryness of na sopharyngolaryngeal mucosa, headache and depressed pulmonary function which may eventually lead to pulmonary congestion or edema. 5. Smog The most outstanding incident of the smog occurred in London from December 5 through 8, 1952, because of which the mortality of the respiratory diseases increased fourfold. The smog was thought to be due to the smoke produced by incomplete combustion and its byproduct the sulfur oxides, and the dust was thought to play the secondary role. In new sense, hazardous is the photochemical smog which is produced by combination of light energy and the hydrocarbons and oxidant in the air. The Yonsei University Institute for Environmental :pollution Research launched a project to determine the relationship between the pollution and the medical, ophthalmological and rhinopharyngological disorders. The students (469) of the "S" Technical School in the most heavily polluted area in Pusan (Uham Dong district) were compared with those (345) of "K" High School in the less polluted area. The investigated group had those with subjective symptoms twice as much as the control group, 22.6% (106) in investigated group and 11.3% (39) in the control group. Among those symptomatic students of the investigated group. There were 29 with respiratory symptoms (29%), 22 with eye symptoms (21%), 50 with stuffy nose and rhinorrhea (47%), and 5 with sore thorat (5%), which revealed that more than half the students (52%) had subjective symptoms of the rhinopharyngological aspects. Physical examination revealed that the investigated group had more number of students with signs than those of the control group by 10%, 180 (38.4%) versus 99 (28.8%). Among the preceding 180 students of the investigated group, there were 8 with eye diseases (44%), 1 with respiratory disease (0.6%), 97 with rhinitis (54%), and 74 with pharyngotonsillitis (41%) which means that 95% of them had rharygoical diseases. The preceding data revealed that the otolaryngological diseases are conspicuously outnumbered in the heavily polluted area, and that there must be very close relationship between the air pollution and the otolaryngological diseases, and the anti-pollution measure is urgently needed.

  • PDF

Characteristics on De-CH4/NOx according to Ceramic and Metal Substrates of SCR Catalysts for CNG Buses (CNG 버스용 SCR 촉매의 세라믹과 메탈 담체에 따른 De-CH4/NOx 특성)

  • Seo, Choong-Kil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.18-24
    • /
    • 2018
  • The policy-making and technological development of eco-friendly automobiles designed to increase their supply is ongoing, but the internal combustion engine still accounts for about 95% of the automobiles in use. Also, in order to meet the stricter emission regulations of internal combustion engines based on fossil fuels, the proportion of after-treatments for vehicles and (ocean going) vessels is gradually increasing. Natural gas is a clean fuel that emits few air pollutants and has been used mainly as a fuel for city buses. In the long term, we intend to develop a new NGOC/LNT+NGCO/SCR combined system that simultaneously reduces the toxic gases, $CH_4$ and NOx, emitted from CNG buses. The objective of this study is to investigate the characteristics of $de-CH_4/NOx$ according to the ceramic and metal substrates of the SCR (Selective Catalytic Reduction) catalysts mounted downstream of the combined system. The V and Cu-SCR catalysts did not affect the $CH_4$ oxidation reaction, the two NGOC/SCR catalysts each coated with two layers began to oxidize $CH_4$ at $400^{\circ}C$, and the amount of $CH_4$ emitted was reduced to about 20% of its initial value at about $550^{\circ}C$. The two NGOC/SCR catalysts each coated with two layers showed a negative (-) NOx conversion rate above $350^{\circ}C$. The ceramic-based combined system reached LOT50 at $500^{\circ}C$, which was about 20% higher in terms of the $CH_4$ conversion rate than the metal-based combined system, showing that the combined system of NGOC/LNT+Cu-SCR is a suitable combination.