• 제목/요약/키워드: Gas Alarm

검색결과 81건 처리시간 0.036초

가정용 보일러의 불완전연소가스 누출확산 메커니즘 해석 (Analysis of Mechanism for Diffusion of Incomplete Combustion Gas Released from Domestic Gas Boiler)

  • 강승규;최경석;윤준용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2868-2873
    • /
    • 2008
  • Carbon Monoxide(CO) poisoning accident is higher than any other gas accident in the rate of deaths/incidents. In the last five years, 36 people died and 104 were wounded because of carbon monoxide poisoning accident. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of incomplete combustion gas(CO) released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of carbon monoxide alarm was made certain and suggested.

  • PDF

대규모 시설을 위한 다채널 가스 누설 경보기 개발 (Development of Multi Channel Gas Leakage Detector for Large Facility)

  • 정규원
    • 한국안전학회지
    • /
    • 제23권3호
    • /
    • pp.1-7
    • /
    • 2008
  • As a clean fuel, LNG or LPG is widely used in large restaurants or plants instead of coal. These fuels are easy to use and cheap. However, they are inflammable very much and easily exploded at the worst. So there are many laws and regulations legislated for the handling and usage of the gas facilities. Nevertheless, very harsh explosions occurred in several domestic or foreign places. In this paper a gas detection and alarm system was developed for large facilities. A new concept for connecting many gas detectors was proposed and based upon that a system including hardware and software have been developed and tested. Although up to 16 gas detectors apart 1 km from main controller can be connected currently, this system can be easily expanded for more detectors because each gas detector receiver communicates with main controller using industrial standard RS-485 multi drop technique. Furthermore several additive functions was included for the installation and maintenance convenience.

가스보일러 배기통 이탈에 의한 CO가스 누출확산 실험 및 수치해석 (EXPERIMENTAL AND COMPUTATIONAL PREDICTION OF CONCENTRATION OF CARBON MONOXIDE GAS RELEASED FROM EXHAUST TUBE OF GAS BOILER)

  • 강승규;최경석;윤준용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.172-175
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

가스 계량 밸브 시스템의 개발에 관한 연구 (A Study on the development of gas metering valve system)

  • 최영규
    • 한국정보전자통신기술학회논문지
    • /
    • 제7권4호
    • /
    • pp.200-204
    • /
    • 2014
  • 가정에서 사용하는 LPG는 용량을 측정할 수 있는 방법이 없기 때문에 공급자에 의존할 수밖에 없었다. 또한 LPG 가스 교체 시기를 알 수 없기 때문에 가스 용량을 측정하여 교체시기에 대한 경보를 필요로 하고 있다. 본 연구에서는 사용자와 공급자가 믿고 신뢰할 수 있는 있도록 가스통을 교체할 시기를 알려 주고, 공급가스 용량을 쉽게 알 수 있도록 하기 위해 홀 효과 센서를 적용하여 가스 용량 측정 밸브 시스템을 개발하였다.

가스보일러 일산화탄소 누출사고 경감에 관한 연구 (A Study on Prevention of Accidents of Carbon Monoxide Leak from Gas Boilers)

  • 송재창;권휘웅;이영희;문일
    • Korean Chemical Engineering Research
    • /
    • 제50권2호
    • /
    • pp.277-281
    • /
    • 2012
  • 본 연구는 가스보일러 CO 누출사고 경감방안에 관한 연구로서, CO 경보기 및 콘덴싱 보일러 의무화 설치 및 지원금 방법을 제시하였다. CO 중독을 예방하기 위해 CO 경보기를 의무 설치하여야 하며 현재 국산 CO 경보기의 가격이 약 4만원이며, 기초수급생활자 및 일반가정 400만 가구 대상으로 3 년 간 1,000억원의 금액이 소요됨을 제시하였다. 기초생활수급자 20만원, 일반가정 10만원, 400만 가구를 지원해주면, 3 년 간 5,000억원의 금액이 소요되며, 재정마련은 연간 100만대 판매되는 보일러를 콘덴싱 보일러로 의무화 시 년 간 약 2,000억원의 에너지 절감이 되며, 콘덴싱 보일러의 수명이 10년으로 했을 때 총 2조원의 에너지 절감비용이 생긴다. 그 중 6,000억원의 비용은 CO 경보기 및 콘덴싱 보일러 설치 지원비로 사용하며, 10년간 국내가스사고 CO 누출사고 50% 이상의 사고를 경감할 수 있을 것으로 제시하였다.

딥러닝 기반 도시가스 누출량 예측 모니터링 시스템 (An Predictive System for urban gas leakage based on Deep Learning)

  • 안정미;김경영;김동주
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2021년도 제64차 하계학술대회논문집 29권2호
    • /
    • pp.41-44
    • /
    • 2021
  • In this paper, we propose a monitoring system that can monitor gas leakage concentrations in real time and forecast the amount of gas leaked after one minute. When gas leaks happen, they typically lead to accidents such as poisoning, explosion, and fire, so a monitoring system is needed to reduce such occurrences. Previous research has mainly been focused on analyzing explosion characteristics based on gas types, or on warning systems that sound an alarm when a gas leak occurs in industrial areas. However, there are no studies on creating systems that utilize specific gas explosion characteristic analysis or empirical urban gas data. This research establishes a deep learning model that predicts the gas explosion risk level over time, based on the gas data collected in real time. In order to determine the relative risk level of a gas leak, the gas risk level was divided into five levels based on the lower explosion limit. The monitoring platform displays the current risk level, the predicted risk level, and the amount of gas leaked. It is expected that the development of this system will become a starting point for a monitoring system that can be deployed in urban areas.

  • PDF

전력용 변압기 경년열화와 관련된 DGA 대표가스에 관한 연구 (Representative Dissolved Gases indicating Aging of Power Transformers)

  • 권동진;김용현;주병수
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권1호
    • /
    • pp.23-28
    • /
    • 2017
  • The life management technology becomes important as the failure risk of the aged power transformers increases. Asset management technology, therefore, has been developed to evaluate the remaining life and build replacement strategies of power transformers, which enables an optimal investment decisions based on reliability and economic feasibility. The remaining life assessment technology uses data related to such as installation, operation, maintenance, refurbishment, and disposed history of power transformers. The optimal investment decision additionally uses data related to failure and social costs. To develop the asset management technology in power transformers, it is important to find deterioration parameters directly indicating degradation of power transformers. In this study, 110,000 DGA data during the past 35 years have been analyzed in order to find the deterioration parameters related to the degradation of power transformers. The alarm rates of combustible gases ($H_2$, $C_2H_2$, $C_2H_4$, $CH_4$, $C_2H_6$), TCG CO, and $CO_2$ were analyzed as deterioration parameters. The origin of the gas was discussed in connection with discharge, overheating and insulation aging.

자외선/적외선 불꽃감지기 소개 및 오동작 방지를 위한 연구 (Introduction of Ultraviolet/Infrared Flame Detector and Method for False Detection Prevention)

  • 임병현;고낙용;황종선;김영민;김종만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.8-11
    • /
    • 2003
  • We propose that when combustible burn with contain carbon, introduce fire detector with sensor of private-use detectable light energy as infrared and ultraviolet in energy of electromagnetic-wave type radiate from flame, method for correct discrimination to resemble fire produce false alarm of detector such as sun light, hot object radiation, are welding. This research using infrared sensor is pyroelectric infrared sensor based black body radiation theory. Ultraviolet sensor is uv Tron using gas multiplication effect to current discharge and photoelectric effect of metal. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research introduced UV/IR compound type flame detector and proposed method of false alarm reduced to resemble fire. The result propres the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

드론영상을 이용한 소규모 가스 배출시설 탐지 가능성 분석 (Availability Analysis on Detection of Small Scale Gas Emission Facilities using Drone Imagery)

  • 신정일;김익재;황동현;이종민;임성하
    • 지적과 국토정보
    • /
    • 제47권1호
    • /
    • pp.213-223
    • /
    • 2017
  • 최근 우리나라의 대기환경이 악화되고 있으며 대기질에 대한 국민적 관심이 증가하고 있다. 다양한 관측수단이 대기환경 모니터링에 이용되고 있으나, 배출시설에 대한 공간정보가 부재한 실정에서 관측자의 경험과 판단에 의존하고 있다. 본 연구에서는 대기오염물질 배출시설 모니터링을 위한 드론 영상의 활용 가능성을 판단하고자 하였다. 드론 정사영상에 질감 변환 기법을 적용하여 공장지붕에 분포하는 소규모 가스 배출시설을 탐지하였고, 오탐지율을 감소시키기 위하여 수치표면모델(DSM)로 계산한 경사도 자료를 이용하였다. 그 결과 약 80%의 정탐지율과 40%의 오탐지율을 보여주어 소규모 가스 배출시설 탐지에 있어 드론 영상의 활용 가능성이 높다고 할 수 있다. 향후 정탐지율의 향상 및 오탐지율의 감소와 관련된 다양한 시도와 연구가 필요하다. 또한 이러한 결과들을 바탕으로 대기오염물질 배출시설에 대한 3차원 공간정보를 포함하는 데이터베이스를 구축할 필요가 있다.

가스누출 감지용 실리콘 압저항형 절대압센서의 제조 및 온도보상 (Fabrication and Temperature Compensation of Silicon Piezoresistive Absolute Pressure Sensor for Gas Leakage Alarm System)

  • 손승현;김우정;최시영
    • 센서학회지
    • /
    • 제7권3호
    • /
    • pp.171-178
    • /
    • 1998
  • SDB 웨이퍼를 이용하여 실리콘 압저항형 절대압센서를 제조하고 이를 가스누출 감지시스템에 응용하였다. 이 경우 센서는 $0{\sim}600\;mmH_{2}O$, $0{\sim}100^{\circ}C$의 압력, 온도범위에서 정상적으로 동작하여야 하고 다이아프램이 파괴되었을 때 가스가 소자 외부로 누출되어서는 안된다. 따라서 다이아프램 내의 공극을 유리(Pyrex7740)와 진공중($10^{-4}$ torr)에서 양극 접합을 행하였다. 제조된 센서는 압력에 대하여 우수한 선형특성을 보였고, 압력감도는 대기압이상 $0{\sim}600\;mmH_{2}O$의 압력범위에서 $4.06{\mu}V/VmmH_{2}O$ 이었다. 온도보상 일체화 조건을 조사하기 위해 Al 박막저항을 제조하여 온도보상을 행하였는데 오프셋의 온도 drift는 80 %이상, 감도의 온도의존성은 95 %이상 보강 효과를 얻었다. 또한 다이오드(PXIN4001)를 이용한 온도보상시 오프셋의 온도 drift는 98 %이상, 감도의 온도의존성은 90%이상 보상 효과를 나타내었다.

  • PDF