• Title/Summary/Keyword: Gap flow blocking device

Search Result 6, Processing Time 0.022 seconds

Experimental Verification on the Effect of the Gap Flow Blocking Devices Attached on the Semi-Spade Rudder using Flow Visualization Technique (유동가시화를 이용한 혼-타의 간극유동 차단장치 효과에 관한 실험적 검증)

  • Shin, Kwangho;Suh, Jung-Chun;Kim, Hyochul;Ryu, Keuksang;Oh, Jungkeun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.5
    • /
    • pp.324-333
    • /
    • 2013
  • Recently, rudder erosion due to cavitation has been frequently reported on a semi-spade rudder of a high-speed large ship. This problem raises economic and safety issues when operating ships. The semi-spade rudders have a gap between the horn/pintle and the movable wing part. Due to this gap, a discontinuous surface, cavitation phenomenon arises and results in unresolved problems such as rudder erosion. In this study, we made a rudder model for 2-D experiments using the NACA0020 and also manufactured gap flow blocking devices to insert to the gap of the model. In order to study the gap flow characteristics at various rudder deflection angles($5^{\circ}$, $10^{\circ}$, $35^{\circ}$) and the effect of the gap flow blocking devices, we carried out the velocity measurements using PIV(Particle Image Velocimetry) techniques and cavitation observation using high speed camera in Seoul National University cavitation tunnel. To observe the gap cavitation on a semi-spade rudder, we slowly lowered the inside pressure of the cavitation tunnel until cavitation occurred near the gap and then captured it using high-speed camera with the frame rate of 4300 fps(frame per second). During this procedure, cavitation numbers and the generated location were recorded, and these experimental data were compared with CFD results calculated by commercial code, Fluent. When we use gap flow blocking device to block the gap, it showed a different flow character compared with previous observation without the device. With the device blocking the gap, the flow velocity increases on the suction side, while it decreases on the pressure side. Therefore, we can conclude that the gap flow blocking device results in a high lift-force effect. And we can also observe that the cavitation inception is delayed.

Rudder Gap Cavitation Suppression Using Gap Flow Blocking Devices

  • Oh, Jung-Keun;Lee, Chang-Min;Lee, Hee-Bum;Rhee, Shin-Hyung;Suh, Jung-Chun;Kim, Hyo-Chul
    • Journal of Ship and Ocean Technology
    • /
    • v.12 no.4
    • /
    • pp.20-31
    • /
    • 2008
  • Development of rudder gap flow blocking device for lift augmentation and cavitation suppression is presented. In order to verify the performance of this device, cavitation visualization and surface pressure measurements were carried out in a cavitation tunnel. Numerical simulations were conducted using a computational fluid dynamics code for more rigorous verification. The new rudder system is equipped with cam devices, which effectively close the gap between the horn/pintle and movable wing parts. The experimental and computational results show that the proposed rudder system is superior to the conventional rudder systems in terms of the lift augmentation and cavitation suppression.

A Numerical Study on the Influence of the Horizontal Gap upon the Cavitation Behavior of a Horn Type Rudder (혼-타의 수평틈새가 캐비테이션에 미치는 영향에 관한 수치적 연구)

  • Seo, Dae-Won;Lee, Seung-Hee;Kim, Hyo-Chul;Oh, Jung-Keun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.2
    • /
    • pp.113-121
    • /
    • 2010
  • Recently, as container ships become larger and faster, rudder cavitations are more frequently observed near the gap between the horn and rudder plates of the ships to cause serious damages to the rudder surface of the ship. The authors already have suggested through a series of model experiments and numerical computations that employment of an appropriate blocking device for gap flow may retard the gap cavitation. For examples, a cam device installed near the outer edges of the vertical gap or a water-injection device combined with a pair of half-round bars installed inside the gap can considerably reduce the gap cavitation. However, it is also found that effective blocking of the flow through the vertical gap results in growth of the cavitation near the horizontal gap instead. In the present study, effectiveness of the simultaneous blocking of the flow through the horizontal and vertical gaps of a horn type rudder in minimizing the damage by gap cavitation is studied. Additional blocking disks are inserted inside the horizontal gaps on the top and bottom of the pintle block and numerical computations are carried out to confirm the combined effect of the blocking devices.

A numerical simulation for reduction of rudder cavitation with gap flow blocking bars

  • Oh, Jung-Keun;Lee, Seung-Hee;Kim, Sang-Hyun;Seo, Dae-Won
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.4 no.2
    • /
    • pp.71-82
    • /
    • 2012
  • In recent practices, a half circular prismatic bar protruding beyond the concave surface of the horn facing the gap has been formed along the centerplane of a rudder to lessen the gap flow between the horn and the movable portion of the rudder system. If a flow through the gap of a rudder is reduced considerably through this approach, previous numerical studies indicate that not only the gap flow but also the rudder cavitation can be noticeably diminished. In the present study, numerical simulations on two-dimensional rudder sections were performed to show that the blocking ability of the single centre bar can be improved by the proper choice of sectional shape. Moreover, a pair of blocking bars attached symmetric to the centerplane on the opposite convex surface of the movable portion is suggested in the study as well, to circumvent the difficulties arising from the practical application of the single centre bars. The bars are placed near the outer edges of the gap easily accessible at the maximum rudder angle to allow simple installation of the device during a maintenance period of a ship. It is found that the pair of blocking bars further improves the blocking effects and application to a practical three-dimensional rudder also backs up the fact.

A Numerical study for the efficacy of flow injection on the diminution of rudder cavitation

  • Seo, Dae-Won;Lee, Seung-Hee;Kim, Hyo-Chul;Oh, Jung-Keun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.2 no.2
    • /
    • pp.104-111
    • /
    • 2010
  • The complete avoidance of cavitation, as a result of gap flow between the fixed and movable portion of a horn type rudder system, is difficult. To reduce gap flow, it is a common practice to attach a half round prismatic bar that protrudes beyond the concave surface of the horn facing the gap and laid along the centerplane of the rudder. However the employment of such a device does not always yield satisfactory results. Previously, the authors have shown that a pair of blocking bars, attached on the convex surface of the movable portion, better enhance the blocking ability of gap flow to that of a single centre bar installed on the concave surface. This also circumvents difficulties that might occur in practical applications. In the present study, a series of numerical computations show that flow injected into the gap of a rudder may also block the flow within, without employment of any physical devices, such as a half circular bar. This study also shows that the combination of flow injection and blocking bars may result in the synergic augmentation of blocking efficiency of gap flow, as demonstrated in computations for a three dimensional rudder system.

A Study on the Double Gap Blocking Device for the Improvement of Fire Resistance and Airtightness of Steel Door (강철재 도어의 내화, 기밀성 향상을 위한 이중틈새 차단장치에 관한 연구)

  • Lee, Joo-Won;Lim, Bo-Hyuk;Cho, Sung-Kwon;Lee, Hae-Yeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.147-148
    • /
    • 2023
  • Steel doors, which are common in general buildings, do not seal the gap between the door and the floor, so drafts, noise, dust, and lights flow from the outside, and shielding devices are installed in various materials and methods, such as adding magnetic gate paper to the side of the door or installing a gasket under the door, but performance is limited. Accordingly, in order to fundamentally solve these problems, we researched and developed a double gap blocking device that can improve fire resistance and airtightness performance in steel doors. Unlike general products, the double gap blocking device has the advantage of maximizing airtight performance by forming an air layer in the center when the door is closed, as well as greatly improving the fire resistance performance, which is the basic performance of the fire door.

  • PDF