• Title/Summary/Keyword: Gap distance

Search Result 591, Processing Time 0.025 seconds

A COMPUTATIONAL STUDY ABOUT THE ASYMMETRIC AERODYNAMIC EVOLUTION AROUND A CIRCULAR CYLINDER CAUSED BY A MOVING WALL (이동 벽면에 의한 원형 실린더의 비대칭적 공력 발달에 관한 전산연구)

  • Jung J.Y.;Chang J.W.
    • Journal of computational fluids engineering
    • /
    • v.11 no.3 s.34
    • /
    • pp.64-70
    • /
    • 2006
  • A Computational study was carried out in order to investigate the moving wall effect of a circular cylinder at a Reynolds number of $2.0{\times}10^4$. The viscous-incompressible Navier-Stokes equations and Spalart-Almaras turbulent model of the commercial CFD code were adopted for this numerical analysis. The moving wall was set parallel with the freestream, and moving speed was equal to the freestream velocity. The gap ratio is defined as the distance ratio between the circular cylinder diameter and the height from the moving wall. The results show that there is vortex shedding over the critical gap ratio and aerodynamic loads including amplitude and the Strouhal number change according to the gap ratio.

Effects of Gap between Tube and Support Plate on the Steam Generator Tube Wear (증기발생기 세관과 지지대 간극이 세관 마모에 미치는 영향)

  • Park, Chi-Yong;Lee, Yong-Son;Boo, Myung-Hwan;Kim, Tae-Ryong;Kim, Tae-Soon
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.302-307
    • /
    • 2004
  • The major flow-induced vibration mechanisms such as fluid-elastic and turbulence excitation can cause the various types of wear of the steam generator tubes in unclear power plant. It is generally accepted that the tube wear due to vibration is affected by the presence of gap clearance between tube and support plate. Connors showed that the tube wear depth could be estimated by using the relationship between wear volume and sliding distance for contact time. Au-Yang predicted the wear depth by using the nonlinear characteristics of normal work rate to contact time. In this study the effect of gap size on the steam generator tubes wear is analyzed by deriving the wear depth versus normal work rate relationship from these previous results.

  • PDF

The Effect of the Gap of Spline on the Deflection of Propeller Shaft (스플라인의 공차가 프로펠러 샤프트의 처짐에 미치는 영향)

  • Han, Dong-Seop;Lee, Seong-Wook;Kim, Yong;Han, Geun-Jo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.172-174
    • /
    • 2007
  • A propeller shaft is the device which is used to transmit the power between two shafts in a vehicles, an industrial machinery, etc. The end of spline is worm due to the deflection of the propeller shaft, and a lifetime of it is reduced, because it for industrial machinery has the length of 2,500 mm, the weight of $300\;kg_{f},$ and the sliding distance of $\pm250\;mm.$ Accordingly in this study we analyzed the effect of the gap of spline on the deflection of a propeller shaft carrying out the finite element analysis, in order to determine the proper gap of spline to minimize the deflection of it. We adopt 10-kinds of gap of spline from 0.05 mm to 0.5 mm at interval of 0.05 mm as the design parameter for the finite element analysis and the centrifugal force as the load condition.

  • PDF

characteristic of breakdown voltage of electrode gap in vacuum (진공에서 극간 gap에 따른 절연파괴 전압 특성 파악)

  • Yoon, Jae-Hun;Kim, Byung-Chul;Lee, Sueng-Su;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.366-367
    • /
    • 2008
  • SF6 widely used as insulating gas is rising as the environment problem. For decreasing this greenhouse gas, electrical breakdown characteristics of vacuum with air are studied in non-uniform field. The gap of needle to plane was 0.5mm, 0.8mm. The pressure of vacuum the range of 10^-4-10^-5torr. The diameter of a plane made of the stainless steel is150mm. As a result of the experiment, the breakdown voltage is increased about electrode gap distance increased. The electrode material influenced breakdown voltage in vacuum.

  • PDF

The study of the characteristics of micro-gap discharge (미소 전극 간격을 갖는 방전장치에서의 방전특성 연구)

  • Seo, Jeong-Hyun;Shin, Buhm-Jae;Jeong, Heui-Seob;Whang, Ki-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.267-269
    • /
    • 1994
  • Various types of plasma display panels(PDPs) have been developed to realize the flat panel display device. But, many of its characteristics must be improved before it can be commercialized. In order to investigate tile characteristics of micro discharge in a PDP ceil, we have constructed a micro-gap discharge system whose electrode gap can be adjustable between $100-1000{\mu}m$ within $0.1{\mu}m$ accuracy. We measured the minimum sustain voltage, current, delay time of discharge while changing parameters(electrode gap distance, electrode surface area, pressure) which influence discharge characteristics.

  • PDF

Distance measurement technique using a mobile camera for object recognition (객체 인식을 위한 이동형 카메라를 이용한 거리 측정 기법)

  • Hwang, Chi-gon;Lee, Hae-Jun;Yoon, Chang-Pyo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.352-354
    • /
    • 2022
  • Position measurement using a camera has been studied for a long time. This is being studied for distance recognition or object recognition in autonomous vehicles, and it is being studied in the field of indoor navigation, which is a limited space where GPS is difficult to apply. In general, in a method of measuring the distance using a camera, the distance is measured using a distance between the cameras using two stereo cameras and a value measured through a captured image or photo. In this paper, we propose a method of measuring the distance of an object using a single camera. The proposed method measures the distance by using the distance between cameras, such as a stereo camera, and the value measured by the photographed picture through the gap of the photographing time and the distance between photographing.

  • PDF

Fabrication and Small scale Short Circuit Tests of Hybrid Fault Current Limiter Employing Asymmetric Non-Inductive Coil and Fast Switch (이종초전도 코일을 이용한 하이브리드형 한류기의 제작 및 단락실험)

  • Jang, Jae-Young;Kim, Young-Jae;Na, Jin-Bae;Choi, Suk-Jin;Lee, Woo-Seung;Lee, Chang-Young;Park, Dong-Keun;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.41-45
    • /
    • 2011
  • Hybrid fault current limiters (FCL) have been researched at Yonsei University. The hybrid FCL has advantages such as having a rapid response to a sudden fault situation and a fast recovery time from a quench. It consists of an asymmetric HTS coil, a switching module, and a bypass reactor. The asymmetric HTS coil is wound with two different types of HTS wires in an opposite direction so that it has nearly zero inductance at the superconducting state. When the quench occurs at the fault state, a strong magnetic field is generated from the asymmetric coil because of different quench characteristics of two HTS wires, and then a repulsive force is induced in the switching module. The force opens the switch and the fault current is pushed into the bypass reactor. In this research, we analyzed the cause of the repulsive force and confirmed, experimentally and computationally, that the magnitude of a repulsive force is varied by changing the gap distance between the asymmetric coil and the switching module. By using the FEM simulation, we calculated the repulsive force with respect to the gap distance and verified that the effect of the gap distance. Then, short circuit test was carried out to confirm the correct operation of the fast switch.

A study on the difference of movement between Semi adjustable articulator and Oral in vivo (반조절성교합기와 구강에서의 운동 오차에 대한 비교 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.53-59
    • /
    • 2006
  • The movement range on the semi adjustable articulator and the movement range in an oral were measured. And then I studied to analyze the gap. I got wax records by the movement on the semi adjustable articulator, the movement in an oral. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the semi adjustable articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the semi adjustable articulator although it did not finish in an oral. When the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the semi adjustable articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are appeared to be straight. Therefore dental prosthesisses were made by the semi adjustable articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the semi adjustable articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the semi adjustable articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The difference in the range of movement is considered as the gap that is made because the movement only can be occurred as straight in the semi adjustable articulator. 3. When the dental technician understand mandibular movement and articulator deficiencies, they can attain proficiency in use of the articulator and reduce the gap.

  • PDF

An Experimental study on the gap of movement by the hinge articulator (단순교합기에 의한 하악운동의 오차에 대한 실험적 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.111-118
    • /
    • 2003
  • I measured the movement range on the hinge articulator and the movement range in an oral. And then I studied to analyze the gap. I got wax records by the movement on the hinge articulator, the movement in an oral and the movement on the hand articulating. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the hinge articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the hinge articulator although it did not finish in an oral. If the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the hinge articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are fixed previously. Therefore dental prosthesisses were made by the hinge articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the hinge articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the hinge articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The results that were impressed records in oral and impressed records on the hand articulating have many congruities. I think that the simple crown etc. that were made by the hand articulating method except the long span bridge and the free end case that can not measure the vertical dimension exactly can represent similarly the mandibular movement. 3. If we want to represent the mandibular movement similarly, we have to use the articulator that can adjust the horizontal condyle inclination and the lateral condyle inclination at least.

  • PDF