• 제목/요약/키워드: Gap Measurement

검색결과 701건 처리시간 0.022초

SAW를 이용한 CaAs 및 $Al_{0-3}Ga_{0-7}As$ 에너지 갭 측정 (Energy gap measurement of GaAs and $Al_{0-3}Ga_{0-7}As$ using SAW)

  • 박남천;이건일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.389-392
    • /
    • 1987
  • The energy gaps of undoped and Cr doped GaAs and $Al_{0-3}Ga_{0-7}As$ was measured nondestructively using surface acoustic wave (SAW) technique. The result is good agreement with other reported result. This technique is inexpensive and simple one for the measurement of mole fraction of $Al_xGa_{1-x}As$.

  • PDF

Prone Breast Phantom을 이용한 couch 산란영향 평가 (Dosimetric effects of couch attenuation and air gaps on prone breast radiation therapy)

  • 김민석;전수동;배선명;백금문;송흥권
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.43-51
    • /
    • 2017
  • 목 적: 유방암 환자의 방사선치료 시 엎드린 자세를 적용하면 폐와 심장에 들어가는 선량을 줄일 수 있다. 하지만 빔 방향에 포함되는 couch의 영향으로 피부선량 증가 및 심부선량이 감소한다. 따라서 본 실험에서는 air gap을 이용해서 couch로 인한 영향을 줄일 수 있는 방법을 알아보고자 하였다. 대상 및 방법: 본원에서 치료 받은 유방암 환자의 전산화단층영상을 바탕으로 3D 프린터(Builder Extreme 1000)를 이용하여 체적을 동일하게 묘사한 인체모형을 제작하였다. 제작한 인체모형을 전산화단층촬영하고 전산화치료계획시스템(Eclipse 13.6, Varian, USA)을 이용하여 6MV, Field-in-Field technique을 이용한 200 cGy/fx의 치료계획을 수립하였다. 피부선량 측정을 위해 내, 외측 4 지점(Med 1, Med 2, Lat 1, Lat 2)에서 광자극발광선량계(Optically Stimulated Luminescence Detector, OSLD)를 이용한 측정을 진행하였고, 심부선량 측정을 위해 유방의 전면과 후면의 2 지점(Anterior, Posterior)에서 FC65-G ion-chamber를 이용한 측정을 하였다. Couch와 인체모형 사이의 air gap(기준 3 cm)을 1 cm 씩 총 6 cm까지 증가시켜가며 측정하였으며 치료계획 선량을 기준으로 평가하였다. 결 과: 피부선량 측정 결과 외측 지점은 치료계획과 비교하여 ${\pm}5%$ 이내의 유사한 값을 보였다. 내측 1 지점은 air gap이 증가할수록 감소하며 3 cm 이상부터 7 % 이상 감소하였고, 내측 2 지점은 4 % 이상 감소하였다. 심부선량 측정 결과 후면 지점은 air gap 차이에 의한 선량변화가 ${\pm}1%$ 이내의 값을 보였다. 전면 지점의 선량은 air gap이 증가할수록 높아지며 3 cm 이상부터 치료계획 보다 4 % 증가한 값을 보였다. 결 론: 본 실험을 통해 couch와 인체모형 사이의 air gap을 특정 거리까지 증가시켰을 때 couch로 인한 피부선량과 심부선량의 영향이 감소함을 확인하였다. 따라서 유방암 환자에 대한 치료 전 선량평가를 진행하여 각 환자에게 최적의 air gap을 적용한다면 피부보효 효과를 높일 수 있고, 정확한 심부선량의 전달이 가능할 것으로 사료된다.

  • PDF

축류형 인공심장의 자기베어링 제어를 위한 와전류 센서 시스템 개발 (A Development of Eddy Current Sensor System for An Axial-flow type Blood Pump with The Magnetic Bearing)

  • 안치범;문기철;정기석;남경원;이정주;선경
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.310-315
    • /
    • 2007
  • The axial-flow type blood pump(XVAD) which has been developed in our group consists of mechanical parts (an impeller, a diffuser and a flow straightener) and electrical parts (a motor and a magnetic bearing). The magnetic bearing system fully levitates the impeller to remove mechanical coupling with other parts of the pump with constant gap, which needs non-contact type gap sensing. Conventional gap sensors are too large to be adopted to the implantable axial -flow type blood pump. Thus, in this paper, the compact eddy current type gap sensor system proper for the implantable axial-flow type blood pump was developed and its performance was evaluated in vitro. The developed eddy current type gap sensor system is a transformer type and has a differential probe. Sensor coil(probe) has small dimensions(6 mm diameter, 2 mm thickness) and its optimal inductance was determined as 0.068 mH for the measurement range of $0\sim3mm$. It could be manufactured with 130 turns of the 0.04 mm diameter copper coil. The characteristics of the developed eddy current type gap sensor system was evaluated by in vitro experiment. At experiment, it showed satis(actory performance to apply to the magnetic bearing system of the XVAD. It could measure the gap up to 3mm, but the linearity was decreased at the range of $1.8\sim3.0mm$. Moreover, it showed no difference in different media such as the water and the blood at the temperature range of $35\sim40^{\circ}C$.

Semi-spade 타의 간극 캐비테이션에 대한 실험적 연구 (Experimental Investigation on the Gap Cavitation of Semi-spade Rudder)

  • 백부근;김경열;안종우;김용수;김성표;박제준
    • 대한조선학회논문집
    • /
    • 제43권4호
    • /
    • pp.422-430
    • /
    • 2006
  • The horn and movable parts around the gap of the conventional semi-spade rudder are visualized by high speed CCD camera with the frame rate of 4000 fps (frame per second) to study the unsteady cavity pattern on the rudder surface and gap. In addition, the pressure measurements are conducted on the rudder surface and inside the gap to find out the characteristics of the flow behavior. The rudder without propeller wake is tested at the range of $1.0{\leq}{\sigma}_v\;1.6$ and at the rudder deflection angle of $-8{\leq}{\theta}{\leq}10^{\circ}$. The time resolved cavity images are captured and show strong cavitation around the rudder gap in all deflection angles. As the deflection angle gets larger, the flow separated from the horn surface increases the strength of cavitation. The accelerated flow along the horn decreases its pressure and the separated flow from the horn increases the pressure abruptly. The pressure distribution inside the gap reveals the flow moving from the pressure to suction side. In the negative deflection angle, the turning area on the movable part initiates the flow separation and cavitation on it.

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems

  • Park, Jong-Kyoung;Lee, Wan-Sun;Kim, Hae-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.122-128
    • /
    • 2015
  • PURPOSE. To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (${\alpha}$=.05), respectively. RESULTS. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION. Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (< $120{\mu}m$). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.

소나무 분진의 최소착화에너지와 폭발한계 측정에 관한 연구 (The Measurement of Minimum Ignition Energy and Explosion Limit for Pine Tree Dust)

  • 최일곤;조일건;목연수;이동훈;최재욱;하동명
    • 한국가스학회지
    • /
    • 제2권2호
    • /
    • pp.55-60
    • /
    • 1998
  • 열경화성 수지의 충전제로 많이 사용되고 있는 소나무 분진을 시료로 분진폭발의 최소착화에너지와 폭발한계를 측정하여 분진폭발 특성을 고찰하였다. 실험은 전극간 거리, 분진운 농도, 분진입도 및 수분 등에 대한 실험을 행하였다. 그 결과 전극간 거리가 4mm 이하로 되면 증가하는 경향을 나타내었으며, 2mm 이하에서는 착화에너지가 갑자기 무한대로 되어 이 값이 한계전극 거리임을 알았다. 또한 분진운 농도가 증가하고 분진 입도가 미세할수록 폭발성이 용이하였으며, 동일한 입도의 분진에서 수분 함유량이 증가할수록 최소착화에너지가 증가하였다.

  • PDF

Role of Gap Junctions in the Endothelium-Dependent Hyperpolarization of Vascular Smooth Muscle Cells

  • Yamamoto, Yoshimichi;Klemm, Megan F.;Hashitani, Hikaru;Lang, Richard J.;Soji, Tsuyoshi;Suzuki, Hikaru
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제5권1호
    • /
    • pp.1-8
    • /
    • 2001
  • Hyperpolarization of arterial smooth muscle by acetylcholine is considered to be produced by the release of an unidentified chemical substance, an endothelium-derived hyperpolarizing factor (EDHF). Several chemicals have been proposed as the candidate for EDHF. However, none of them fulfil completely the nature and property of EDHF. Ultrastructural observation with electron microscope reveals that in some arteries, gap junctions are formed between endothelial and smooth muscle cells. In small arterioles, injection of gap junction permeable dyes into an endothelial cell results in a distribution of the dye to surrounding cells including smooth muscle cells. These observations allow the speculation that myoendothelial gap junctions may have a functional significance. Simultaneous measurement of the electrical responses in both endothelial and smooth muscle cells using the double patch clamp method demonstrates that these two cell types are indeed electrically coupled, indicating that they behave as a functional syncytium. The EDHF-induced hyperpolarization is produced by an activation of $Ca^{2+}-sensitive\;K^+-channels$ that are inhibited by charybdotoxin and apamin. Agonists that release EDHF increase $[Ca^{2+}]_i$ in endothelial cells but not in smooth muscle cells. Inhibition of gap junctions with chemical agents abolishes the agonist-induced hyperpolarization in smooth muscle cells but not in endothelial cells. All these observations can be explained if EDHF is an electrotonic signal propagating from endothelium to smooth muscle cells through gap junctions.

  • PDF

원형실린더 후류내의 가동형 와류분할판에 의한 항력 감소효과 (Drag Reduction Effect by a Self-Adjustable Splitter Plate on the Flow over a Circular Cylinder)

  • 박운진
    • 대한기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.1262-1275
    • /
    • 1993
  • 본 연구에서는 가동형 분할판을 실린더 후단부로 부터 일정간격 이격시켜 설 치하여, 실린더 바로 후방의 압력에 의한 불안정한 모멘트가 분할판에 직접 작용하지 않도록 하되 와동의 상호 작용은 계속 억제할 수 있도록 설계된 가동형 분할판을 이용 하여 이의 항력 저감효과를 풍동실험을 통하여 조사하였다.

혼-타의 간극 캐비테이션 침식 저감을 위한 실험적 연구 (An Experimental Research on Gap Cavitation Erosion of Semi-spade Rudder)

  • 김성표;박제준;김용수;장영훈;최영복;백부근
    • 대한조선학회논문집
    • /
    • 제43권5호
    • /
    • pp.578-585
    • /
    • 2006
  • Cavitation related erosion damages on semi-spade rudder generally occur at around leading edge of lower-face and behind gap of lower pintle. To get the idea of gap entrance profile for the latter case, a series of tests with large models has been carried out at MOERI. In the tests, the flow pattern around lower pintle have been investigated and visualized by high speed camera. Additionally, cavitation inception tests and pressure measurements have also been conducted for better comparison. As a result a new model (F rudder) has been developed. The new model turned out to have stable pressure distribution along the surface and so the cavitation inception speeds within ${\pm}5^{\circ}$ of rudder angle were delayed approx. 4 knots in average.