• 제목/요약/키워드: Gap Measure

검색결과 427건 처리시간 0.038초

디지털산업에 대한 시민과 산업종사자 간의 인식 차이 연구: 상호지향성 모델을 중심으로 (A Study on the Perception of Digital Industry between Citizen and Industry Workers: An Application of the Co-orientation Model)

  • 노재인;한승혜
    • 한국IT서비스학회지
    • /
    • 제22권4호
    • /
    • pp.159-169
    • /
    • 2023
  • The digital industry area based on digital technology is specialized and rapidly changing. This kind of change lead to a gap of understanding arises between the digital industry and the public. The digital industry is a trend that cannot be reversed, thus efforts to reduce the gap in understanding are necessary for positive social development in the future. This study aimed to find clues to reduce the gap in understanding by measuring the difference in perception between the public and the digital industry. To measure the difference in perception, this study applied the mutual orientation model proposed by McLeod and Chaffee(1973), As a result of the study, both groups agreed that the digital industry would make a positive contribution to the Korean economy in the future. However, it was confirmed that there was a possibility of mutual misunderstanding due to different views on the digital industry.

수직동심환상관에서 반경방향 보이드율의 변동특성 (Fluctuation Characteristics of Radial Void Fraction in Vertical Concentric Annuli)

  • 손병진;김인석;김문철
    • 대한설비공학회지:설비저널
    • /
    • 제16권5호
    • /
    • pp.516-524
    • /
    • 1987
  • This paper presents experimental data of fluctuation characteristics of local void fraction of air-water two-phase flow which are associated with the flow pattern, annular gap size and radial location in vertical concentric annuli with coefficient of skewness and kurtosis. The annular gap widths are 13mm, 11mm, and 9mm for a 38m inner diameter as the lucite outer tube. A electrical conductivity probe was used to measure the local void fraction and traversed diametrically from inner wall to outer wall using radial increments of 2mm. It was shown that distribution of the coefficient of skewness and kurtosis, which is related that the one is the asymmetry and the other peakness of local void fraction distribution was influenced by flow pattern, annular gap size and radial location.

  • PDF

동적 다엽콜리메이터의 Leaf gap이 전산화 치료계획에 미치는 영향 (The dosimetric impact on treatment planning of the Dynamic MLC leaf gap)

  • 김정미;윤인하;홍동기;백금문
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.233-238
    • /
    • 2014
  • 목 적 : 최근 사용이 급증하고 있는 미국 베리안사의 이클립스 치료계획 시스템은 치료기에 설치되어 있는 다엽콜리메이터의 충돌 보호를 위해 존재하는 하드웨어적 제한성을 립 갭이라는 설정을 통하여 소프트웨어적으로 극복함으로써 정확한 치료계획을 구현 할 수 있도록 한다. 본 연구에서는 이클립스 치료계획 시스템에 설정되어 있는 립 갭이 치료계획에 미치는 영향을 분석하고 정확한 임상적용에 이용할 수 있도록 하고자 한다. 대상 및 방법 : 연구에 사용되어진 이클립스 치료계획 시스템의 버전은 11.0이다. 시스템에 설정되어 있는 립 갭은 각 치료기와 광자 에너지별로 측정되었다. 일반적으로 0.05~0.30 mm의 값을 가지고 있고, 다엽콜리메이터의 교정상태에 따라 다르므로 일괄되게 적용하지 않고 측정를 통하여 적용한다. 본 연구에서는 세기변조와 용적변조 치료계획을 측정된 각각의 립 갭을 적용하고, 립 갭이 달라질 때마다 치료계획의 영향을 Dmax, CI 등을 이용하여 평가하였다. 결 과 : 동일한 치료계획을 각각의 치료기에서 립 갭을 변화하며 평가하였을 때, 립 갭이 0.05 mm ~ 0.50 mm로 증가할수록 Dmax, CI 의 값이 2~5% 이상 증가하였다. 세기변조방사선치료계획과 용적변조방사선치료계획 모두 동일한 경향을 나타내었고 각 치료계획 간의 유의성은 찾아 볼 수 없었다. 결 론 : 치료기의 다엽콜리메이터의 립 갭 설정은 일반적으로 고유한 측정값을 가지고 있다. 하지만, 다엽콜리메이터의 노후, 교정, 수리 및 점검 후에 립 갭은 변할 수 있고, 이러한 값은 결국 치료계획에 영향을 미치기 때문에 반드시 확인 후 치료에 적용해야 한다. 경우에 따라선 립 갭을 초기 설정값을 유지하는 할 수 있는데, 이는 치료계획에 미치는 영향을 무시할 수 있기 때문에 바람직하지 않다.

축류형 인공심장의 자기베어링 제어를 위한 와전류 센서 시스템 개발 (A Development of Eddy Current Sensor System for An Axial-flow type Blood Pump with The Magnetic Bearing)

  • 안치범;문기철;정기석;남경원;이정주;선경
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.310-315
    • /
    • 2007
  • The axial-flow type blood pump(XVAD) which has been developed in our group consists of mechanical parts (an impeller, a diffuser and a flow straightener) and electrical parts (a motor and a magnetic bearing). The magnetic bearing system fully levitates the impeller to remove mechanical coupling with other parts of the pump with constant gap, which needs non-contact type gap sensing. Conventional gap sensors are too large to be adopted to the implantable axial -flow type blood pump. Thus, in this paper, the compact eddy current type gap sensor system proper for the implantable axial-flow type blood pump was developed and its performance was evaluated in vitro. The developed eddy current type gap sensor system is a transformer type and has a differential probe. Sensor coil(probe) has small dimensions(6 mm diameter, 2 mm thickness) and its optimal inductance was determined as 0.068 mH for the measurement range of $0\sim3mm$. It could be manufactured with 130 turns of the 0.04 mm diameter copper coil. The characteristics of the developed eddy current type gap sensor system was evaluated by in vitro experiment. At experiment, it showed satis(actory performance to apply to the magnetic bearing system of the XVAD. It could measure the gap up to 3mm, but the linearity was decreased at the range of $1.8\sim3.0mm$. Moreover, it showed no difference in different media such as the water and the blood at the temperature range of $35\sim40^{\circ}C$.

Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems

  • Park, Jong-Kyoung;Lee, Wan-Sun;Kim, Hae-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.122-128
    • /
    • 2015
  • PURPOSE. To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (${\alpha}$=.05), respectively. RESULTS. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION. Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (< $120{\mu}m$). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.

초음파를 이용한 중수로내 칼란드리아관과 원자로 정지물질 주입관과의 간격 측정 (Ultrasonic Measurement of Gap between Calandria Tube and Liquid Injection Nozzle in CANDU Reactor)

  • 손석만;김태룡;이준신;이영희;박철훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.834-839
    • /
    • 2001
  • Calandria tube wrapping each pressure tube is one of the key structural components of CANDU reactor(Calandria) which is consisted of many pressure tubes containing nuclear fuel assemblies. As the Calandria tube(made of zirconium alloy) is sagging due to its thermal and irradiation creep during the plant operation, it possibly contacts with liquid injection nozzle crossing beneath the Calandria tube, which subsequently results in difficulties on the safe operation. It is therefore necessary to check the gap for the confirmation of no contacts between the two tubes, Calandria tube and liquid injection tube, with a proper measure during the life of plant. In this study, an ultrasonic measurement method was selected among several methods investigated. The ultrasonic device being developed for the measurement of the gap was introduced and its preliminary performance test results were presented here. The gap between LIN and CT at site was measured using by this ultrasonic device at site.

  • PDF

Mitigation of seismic collision between adjacent structures using roof water tanks

  • Mahmoud, Sayed
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.171-184
    • /
    • 2020
  • The potential of using the roof water tanks as a mitigation measure to minimize the required separation gap and induced pounding forces due to collisions is investigated. The investigation is carried out using nonlinear dynamic analysis for two adjacent 3-story buildings with different dynamic characteristics under two real earthquake motions. For such analysis, nonlinear viscoelastic model is used to simulate forces due to impact. The sloshing force due to water movement is modelled in terms of width of the water tank and the instantaneous wave heights at the end wall. The effect of roof water tanks on the story's responses, separation gap, and magnitude and number of induced pounding forces are investigated. The influence of structural stiffness and storey mass are investigated as well. It is found that pounding causes instantaneous acceleration pulses in the colliding buildings, but the existence of roof water tanks eliminates such acceleration pulses. At the same time the water tanks effectively reduce the number of collisions as well as the magnitude of the induced impact forces. Moreover, buildings without constructed water tanks require wider separation gap to prevent pounding as compared to those with water tanks attached to top floor under seismic excitations.

Channel Gap Measurements of Irradiated Plate Fuel and Comparison with Post-Irradiation Plate Thickness

  • James A. Smith;Casey J. Jesse;William A. Hanson;Clark L. Scott;David L. Cottle
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2195-2205
    • /
    • 2023
  • One of the salient nuclear fuel performance parameters for new fuel types under development is changes in fuel thickness. To test the new commercially fabricated U-10Mo monolithic plate-type fuel, an irradiation experiment was designed that consisted of multiple mini-plate capsules distributed within the Advanced Test Reactor (ATR) core, the mini-plate 1 (MP-1) experiment. Each capsule contains eight mini-plates that were either fueled or "dummy" plates. Fuel thickness changes within a fuel assembly can be characterized by measuring the gaps between the plates ultrasonically. The channel gap probe (CGP) system is designed to measure the gaps between the plates and will provide information that supports qualification of U-10Mo monolithic fuel. This study will discuss the design and the results from the use of a custom-designed CGP system for characterizing the gaps between mini-plates within the MP-1 capsules. To ensure accurate and repeatable data, acceptance and calibration procedures have been developed. Unfortunately, there is no "gold" standard measurement to compare to CGP measurements. An effort was made to use plate thickness obtained from post-irradiation measurements to derive channel gap estimates for comparison with the CGP characterization.

Beam-Stop Array를 이용한 DR에서의 Scatter Fraction 측정 및 효용성 평가 (Measurement and Evaluation of Scatter Fractions for Digital Radiography with a Beam-Stop Array)

  • 최유나;조효민;김이슬;안수정;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.9-15
    • /
    • 2010
  • X-선 영상 촬영 시 피사체에 조사되는 X-선은 피사체 내부에서 필연적으로 산란을 일으킨다. 산란선은 영상시스템에 도달하여 영상의 대조도를 저하시키고 전체 농도(Background)를 불균일하게 만든다. 현재 학계의 연구 동향은 산란선에 의한 영상의 화질 저하를 방지하기 위한 방법 고안에 초점을 두고 있다. 본 연구의 목적은 영상에서의 scatter fraction을 정확하게 측정하여 영상시스템의 개선에 기여하고 대조도에 영향을 미치는 인자의 정량적 평가를 최적화하기 위함에 있다. Scatter fraction을 정확하게 측정하기 위하여 beam stop array를 제작하였다. 제작한 beam stop array를 이용하여 영상을 획득하고, 영상의 각 부위에서의 scatter fracton 측정을 자동화하기 위해 MATLAB을 이용한 프로그램(SFC: Scatter Fraction Calculator)을 개발하였다. 그리드 유 무와 air gap 효과에 따른 scatter fracton의 비교를 통하여 beam stop array와 SFC 프로그램의 효용성을 평가하였다. 그리드가 있을 경우의 scatter fraction이 그리드가 없는 경우에서 보다 낮은 값으로 측정되었으며 air gap이 증가함에 따라 scatter fracton이 감소함으로써 효용성을 입증했다. Beam stop array와 SFC 프로그램은 입증된 효용성을 기반으로 임상에서 흉부뿐 아니라 인체의 여러 부위에 이를 활용할 수 있을 것으로 기대된다.