In this study, a new thin films passivation technique using Zn with high electronegativity and $MgF_2$, a fluorine material with better optical transmittance than the sealing film materials that have thus far been reported was proposed. Targets with various ratios of $MgF_2$ to Zn (5:5, 4:6 and 3:7) were fabricated to control the amount of Zn in the passivation films. The Mg-Zn-F films were deposited onto the substrates and Zn was located in the gap between the lattices of $MgF_2$ without chemical metathesis in the Mg-Zn-F films. The thickness and optical transmittance of the deposited passivation films were approximately 200 nm and 80%, respectively. It was confirmed via electron dispersive spectroscopy (EDS) analysis that the Zn content of the film that was sputtered using a 4:6 ratio target was 9.84 wt%. The Zn contents of the films made from the 5:5 and 3:7 ratio targets were 2.07 and 5.01 wt%, respectively. The water vapor transmission rate (WVTR) was determined to be $38^{\circ}C$, RH 90-100%. The WVTR of the Mg-Zn-F film that was deposited with a 4:6 ratio target nearly reached the limit of the equipment, $1\times10^{-3}\;gm^2{\cdot}day$. As the Zn portion increased, the packing density also increased, and it was found that the passivation films effectively prevented the permeation by either oxygen or water vapor. To measure the characteristics of gas barrier, the film was applied to the emitting device to evaluate their lifetime. The lifetime of the applied device with passivation was increased to 25 times that of the PLED device, which was non-passivated.
보육보조금은 일반적으로 여성의 노동시장참여를 용이하게 해주려는 것과 아동이 양질의 보육 및 교육 환경에서 돌보아지는 것을 돕는 목표로 지급된다. 본 연구는 보육시설을 이용하는 영아가구에 보육료를 지원하는 영아기본보조금의 효과를 살펴봄으로써 영아기본보조금이 그 정책목표를 달성하고 있는지 검토한다. 기본보조금이 2006년 민간보육시설에만 도입되었고 유아는 제외하고 영아에게만 지급된다는 준실험적(Quasi-Experiment) 설정을 이용하여 시설 측면과 가구 측면의 효과를 분석한다. 분석 결과, 보조금으로 인해 영아의 이용비중이 높은 보육시설에서는 교사의 처우 및 시설환경이 개선되는 등의 효과가 나타났으나 여성의 노동공급에는 거의 영향을 미치지 않았고, 수요자의 보육만족도에도 부정적 영향을 미친 것으로 나타났다.
본 연구는 고 레이놀즈 영역에서 후류측에 분리된 분할판(Detached splitter plate)을 가진 원주의 유동장 특성을 양 항력측정 실험과 PIV를 이용한 가시화 실험으로 파악한 것이다. 실험파라메터는 원주 한변의 길이에 대한 분할판의 폭비(H/B=0.5~1.5) 및 원주 후면에서부터 분할판의 앞전까지의 거리(G/B=0~2)로 했다. 분할판의 폭비를 고정시킨 경우 원주의 항력감소율은 간격비가 증가할수록 증가한 후 감소하는 특성을 보였다. 또한 같은 간격비에서는 분할판의 폭비가 클수록 원주의 항력감소율이 컸다. 분리된 분할판의 설치에 의해 분할판의 상, 하부에는 서로 반대방향의 볼테스가 발생되었고, 이 볼텍스가 원주 후류측에 역류를 발생시켜, 원주에 작용하는 항력을 감소시켰다.
Purpose : To assess perceptual, acoustic and aerodynamic measure of voice quality in patients with unilateral vocal cord paralysis before and after type I thyroplasty. Methods : The clinical records of patients operated type I thyroplasty in the Departement of otorhinoalryngolgy, Yongdong Severance hospital from November 2001 to November 2003 were reviewed. All patients uderwent a vocal function evaluation including perceptual, acoustic and aerodynamic measures of voice preoperative and on $60^{th}$ postoperative day. The perceptual and acoustic measures were obtained from recording of patients' reading a 'Sanchak' passage. The perceptual evaluation was performed by 2 speech pathologist using a 4-point rating scale. Acoustic parameters(voice range profile low(RAL), voice range profile high(RAH), average fundamental frequency(AFX), closed quotient, harmonic to noise ratio, jitter and shimmer) were investigated by Lx speech studio. Mean flow rate(MFR), subglottic pressure(Psub) and intensity were measured using the Phonatory function analyzer. The maximum phonation time was also measured. The data were statistically analyzed. A paired t-test (p<0.1) was used to compare preoperative and postoperative results. And multiple regression test was used to find which parameter was most correlated to improvement of postoperative voice quality. Results : Among aerodynamic parameters, Psub $(88.11mmH_2O{\rightarrow}58.7mmH_2O)$, MPT(7.87sec${\rightarrow}$12.53sec), MFR (359.8ml/sec${\rightarrow}$161.06ml/sec) were statistically improved. AFx(205.5Hz${\rightarrow}$163.27Hz), AQx(23.9%${\rightarrow}$48.3%), RAL, RAH. Jotter and shimmer were improved. In multiple regression test, AFx and AQx was noted as the two meost correlated parameters to improvement of postoperative breathiness. But general grade of voice quality was more correlated to Psub and shimmer. Conclusion : Vocal fold medialization procedures effectively reduce glottic gap. Increasing of contact area of both vocal folds induced improvement in aerodynamic parameters and leaded stabilizing of vocal fold vibration. That effect results in improvement in acoustic parameters (shimmer, jitter, signal-to-noise ratio, voice range profile) and voice quality.
직접인쇄기술 방식은 기존의 포토리소그래피 방법을 이용한 패터닝 기술에 비해 저비용, 간단한 공정 과정, 친환경성 등 여러 장점들로 인해 미세 회로 형성 분야의 그린 테크놀로지로 최근 각광받고 있다. 이러한 프린팅 기반의 전자기술을 상용화하기 위해서는 프린팅 방식으로 형성된 회로의 전기적 특성 평가가 필수적인데, 이에 본 연구에서는 구리 잉크를 이용하여 잉크젯 프린팅 방식으로 2 가지 타입, parallel transmission line(PTL)과 coplanar waveguide(CPW) 구조의 회로를 형성하고 $250^{\circ}C$에서 30분 동안 소결하여 완성하였다. 전류-전압 그래프로 직류 저항을 측정하여 벌크 구리의 비저항 값의 약 3.3배되는 평균 0.558 ${\mu}{\Omega}{\cdot}cm$의 비저항 값을 도출하였고 회로의 고주파 특성 평가를 위해 주파수 범위 0~30 GHz에서 probe station chuck과 샘플 간의 갭 유무에 따른 scattering parameter를 측정하였다. 모든 시편에서 5 dB 이하의 반사 특성을 보였으며, PTL 회로가 CPW 구조보다 전반적으로 더 좋은 통과 특성을 나타내었다.
In the development of linear perspective, Brook Taylor's theory has achieved a special position. With his method described in Linear Perspective(1715) and New Principles of Linear Perspective(1719), the subject of linear perspective became a generalized and abstract theory rather than a practical method for painters. He is known to be the first who used the term 'vanishing point'. Although a similar concept has been used form the early stage of Renaissance linear perspective, he developed a new method of British perspective technique of measure points based on the concept of 'vanishing points'. In the 15th and 16th century linear perspective, pictorial space is considered as independent space detached from the outer world. Albertian method of linear perspective is to construct a pavement on the picture in accordance with the centric point where the centric ray of the visual pyramid strikes the picture plane. Comparison to this traditional method, Taylor established the concent of a vanishing point (and a vanishing line), namely, the point (and the line) where a line (and a plane) through the eye point parallel to the considered line (and the plane) meets the picture plane. In the traditional situation like in Albertian method, the picture plane was assumed to be vertical and the center of the picture usually corresponded with the vanishing point. On the other hand, Taylor emphasized the role of vanishing points, and as a result, his method entered the domain of projective geometry rather than Euclidean geometry. For Taylor's theory was highly abstract and difficult to apply for the practitioners, there appeared many perspective treatises based on his theory in England since 1740s. Joshua Kirby's Dr. Brook Taylor's Method of Perspective Made Easy, Both in Theory and Practice(1754) was one of the most popular treatises among these posterior writings. As a well-known painter of the 18th century English society and perspective professor of the St. Martin's Lane Academy, Kirby tried to bridge the gap between the practice of the artists and the mathematical theory of Taylor. Trying to ease the common readers into Taylor's method, Kirby somehow abbreviated and even omitted several crucial parts of Taylor's ideas, especially concerning to the inverse problems of perspective projection. Taylor's theory and Kirby's handbook reveal us that the development of linear perspective in European society entered a transitional phase in the 18th century. In the European tradition, linear perspective means a representational system to indicated the three-dimensional nature of space and the image of objects on the two-dimensional surface, using the central projection method. However, Taylor and following scholars converted linear perspective as a complete mathematical and abstract theory. Such a development was also due to concern and interest of contemporary artists toward new visions of infinite space and kaleidoscopic phenomena of visual perception.
본 연구는 환경샘플 중 병원균을 진단하기 위한 목적을 가진다. 최소 챔버 칩에서 환경 샘플 중 병원균을 농축하고 mRNA를 증폭하여 효과적이고 간단한 진단방법을 고안하였다. PDMS로 면적 $1.5\;cm{\times}\;1.5\;cm$, 높이 $100\;{\mu}L$의 칩을 제작하여 유리에 부착시켰다. RNase에 의한 진단 오류 또는 실패를 막고자 RNase away 처리를 하고, RNA와 PDMS의 결합을 막기 위해 BSA 처리를 하였다. 수질에 있는 병원균은 매우 적은 농도로 존재하므로 농축의 과정이 필요하다. 농축의 방법에는 여러 가지가 있으나 본 연구에서는 유리 비드를 칩 내에 삽입하고 저농도의 시료를 주입함으로서 고농도로 농축을 하는 방법을 사용하였다. 그러나 부피가 작은 칩 내에서 수행하기에는 내부 압력이 작용하여 문제가 발생하여 $100\;{\mu}m$의 유리 비드를 사용하고 유리비드의 칩 내부 이탈을 방지하기 위하여 댐을 만들어 농축에 가장 적합한 칩의 형태를 잡았다. 시료의 주입속도에 따라 내부 압력이 상승하여 댐의 기능이 상실하여 유리 비드가 이탈하게 되므로 그것을 방지하기 위하여 칩 내에 댐을 강화하여 만들고 내부압력 증가가 방지되는 최적의 댐을 개발하여 시료의 주입 속도 5 mL/min까지 유리 비드의 이탈을 막았다. 유리 비드에서의 RNA 농축은 pH 5에서 효과적이고 pH가 증가할수록 유리 비드와 RNA의 결합이 끊어지는 현상을 보였으므로 시료에 pH 5의 버퍼를 첨가하여 농축을 진행하고 중성의 NASBA 용액을 주입하여 유리비드에서 탈착된 농축된 고농도의 RNA를 증폭하였다. NASBA는 항온 수조에서 온도에 변화 없이 $41^{\circ}C$에서 1시간 30분 동안 진행하며 증폭된 mRNA는 직접 확인하였다. 이 방법은 LOC 기술을 적용하여 저농도의 시료를 효과적으로 측정할 수 있도록 편리한 바이오 칩을 개발함으로써 대용량의 샘플 중 극 저농도의 대장균을 효과적으로 검출할 수 있는 장점을 가지고 있다.
I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.
Background and Objectives : There are few studies reported that specifically examine the laryngeal function in patients with profound hearing loss or deafness, This study was designed to examine videostroboscopic findings and phonetic characteristics in adult patients with prelingually deaf. Materials and Method: Sixteen patients (seven males, nine females) diagnosed as prelingually deaf aged from 19 to 54 years, and were compared with a 20 normal control group with no laryngeal pathology and normal hearing group, Videostroboscopic evaluations were rated by experienced judges on various parameters describing the structure and function of the laryngeal mechanism during comfortable pitch and loudness phonations. Acoustic analysis test were done, and a nasalance test performed to measure rabbit, baby, and mother passage. CSL were measured to determine the first and two formant frequencies of vowels /a/, /i/, /u/, Statistical analysis was done using Mann-Whitney U or Wilcoxon signed ranks test. Results: Videostroboscopic findings showed phase symmetry but significantly more occurrences decrement in the amplitude of vibration, mucosal wave, irregularity of the vibration and increased glottal gap size during the closed phase of phonation, In addition, group of prelingually deaf patients were observed to have significantly more occurrences of abnormal supraglottic activities during phonation. The percentage of shimmer in the group of prelingually deaf patients were higher than in the control group. Characteristics of vowels were lower of the second formant of the vowel /i/. Nasalance in prelingually deaf patients showed normal nasality for all passages, Conclusion: Prelingually deaf patients show stroboscopic abnormal findings without any mucosal lesion, suggesting that they have considerable functional voice disorder. We suggest that prelingually deaf adults should perform vocal training for normalized laryngeal function after cochlear implantation.
전라북도 김제시 부량면 신용리의 벼-보리 이모작 논에 설치된 플럭스 관측시스템에서 보리 재배기간동안(2011년 10월 27일~2012년 6월 8일) 연속적으로 관측된 플럭스 자료를 활용하여, 보래재배 논 생태계와 대기간의 $CO_2$ 교환량의 계절적 변화를 분석하였다. $CO_2$ 및 에너지의 교환량은 미기상학적인 에디공분산법으로 추정하였고, 환경인자(순복사, 강수량 등)와 작물체 생육량(엽면적지수, 초장 등)도 함께 측정 조사하였다. 관측된 플럭스 자료는 보정과 결측보충의 과정을 거친 후 분석에 활용되었다. 결론적으로, 벼-보리 이모작 논생태계에서 보리 재배기간동안의 보리생육은 $CO_2$의 순생태계교환량(NEE)에 큰 영향을 주는 것으로 분석되었다. 보리 건물중이 급격하게 증가되는 분얼단계에서 가장 많은 $CO_2$가 흡수되었으며, 출수개화기가 관측된 5월 상순에 가장 높은 NEE ($-11.2gCm^{-2}d^{-1}$)가 관측되었다. 보리 재배기간중의 누적 순생태계 교환량(NEE)과 총일차생산량(GPP) 및 생태적 호흡량(Re)은 각각 단위면적($m^2$)당 -348.0, 663.3, $315.2gCm^{-2}$로 분석되었다. 본 논문은 국내에서 보리 재배기간의 $CO_2$ 플럭스를 에디공분산기법으로 정량화한 최초의 연구결과이며, 향후 벼-보리 이모작 논 생태계의 $CO_2$ 수지 평가의 기초자료로 활용될 것으로 기대한다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.