• 제목/요약/키워드: Gamma-ray transmission measurement

검색결과 6건 처리시간 0.02초

Development of a real-time mobile gamma-ray measurement system for shipboard use

  • Chang-Jong Kim;Mee Jang;Hyuncheol Kim;Jong-Myoung Lim;Wanno Lee;Gyu-Seong Cho
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4077-4082
    • /
    • 2023
  • Large areas must be rapidly screened to monitor radiation in marine environments. For this purpose, this study developed a mobile real-time gamma-ray measurement system for shipboard use and evaluated its performance. The system was developed to measure engine or generator cooling water by installing a canister inside the ship. The minimum detectable activity of the system is about 0.8 Bq/L for a 60 s measurement period, and real-time data transmission and remote control are possible. The system was tested in the field and is currently being installed and operated on ships in service. Such a ship-based real-time gamma-radiation measurement system is suitable for a wide range of marine radiation surveillance applications and is expected to be rapidly deployed.

몬테칼로 전산모사를 이용한 감마선 투과계측 증류탑 진단기술의 타당성 연구 (Feasibility Study of Gamma Ray Transmission Technique in Distillation Column Using Monte Carlo Simulation)

  • 문진호;김종범;박장근;정성희
    • 방사선산업학회지
    • /
    • 제7권2_3호
    • /
    • pp.115-119
    • /
    • 2013
  • The density profile measurement technology by gamma transmission has been widely used to diagnose processes in the field of refinery and petrochemical industry. This technology can reveal a clue and position of abnormal phenomenon of industrial processes during their operation. In this paper, the feasibility of the gamma transmission technology for detecting changes in the amount of fluid in a distillation column was evaluated by using Monte Carlo simulations. The simulations assumed that $^{60}Co$ (1.17, 1.33 MeV) sources and NaI (Tl) detectors (${\Phi}5{\times}5cm$) are located in opposite sides of a column and it concurrently moves in vertical direction. To determine the dependency of a spatial resolution on aperture size of a collimator, the simulation model for a tray in a column were simulated with the aperture sizes of 1 and 2 cm. The thickness of the high density area including a tray and fluid was 7.6 cm in the simulation. The spatial resolution of the tray was 8.2 and 8.5 cm, respectively. As a result, it was revealed that the conventional density profile measurement technique is not able to show the deviation of liquid level on a tray in a column.

보온재 부착 파이프라인의 부식두께 측정에 관한 연구 (A Study on Real-Time Corrosion Thickness Measurement Technique of Insulated Pipeline)

  • 장지훈;조경식;이종오;김기동
    • 연구논문집
    • /
    • 통권31호
    • /
    • pp.135-147
    • /
    • 2001
  • The wall-thickness of insulated pipelines can be easily evaluated by measuring the gamma-ray transmission intensity because this intensity is inversely proportional to the thickness of insulated pipeline. The main purpose of this study is to develop the nondestructive and filmless on-line inspection system of corrosion by measuring the wall thickness of insulated pipeline. The inspection system is constructed with radioisotope, 64 channel photo diode array detector, crawler system and data taking and operating software. The traditional off-line radiographic method carried out by exposing film cassettes can be replaced by this cost-effective on-line digital imaging method and the application will be greatly expected especially in the chemical and petrochemical industries.

  • PDF

방사성폐기물드럼 핵종분석에서 감마선 감쇠보정 방법들의 비교 평가 (Comparison of the Correction Methods for Gamma Ray Attenuation in the Radioactive Waste Drum Assay)

  • 지영용;유영걸;곽경길;강덕원;김기홍
    • 방사성폐기물학회지
    • /
    • 제4권3호
    • /
    • pp.275-284
    • /
    • 2006
  • 실제 드럼 내에 존재하는 핵종으로부터 방출되는 감마선을 외부에서 측정하여 그로부터 드럼 내 핵종의 양을 정확하게 분석하기 위해서는 먼저 적절한 교정표준의 선택과 드럼 내 매질의 밀도와 핵종의 분포에 대한 감마선 감쇠보정이 반드시 필요하다. 본 연구에서는 드림 내 핵종의 분석을 위하여 밀도가 다른 두 개의 모델드럼을 이용하였으며 전송선원으로써는 $^{152}Eu$(10 mCi), 표준선원으로는 혼합선원($^{133}Ba,\;^{137}Cs,\;^{60}Co$)을 이용하였다. 그리고 드럼과 검출기 사이의 거리를 달리하면서 모델드럼 내의 표준선원으로부터 나오는 감마선을 계측하여, 감쇠보정이 되지 않은 이 측정값에 3 종류의 감마선 감쇠보정을 각각 수행하였다. 그 결과 밀도가 낮은 드럼에서의 오차는 10 % 이하이었고, 밀도가 높은 드럼에서의 오차는 25 % 이하이었다. 또한 드럼과 검출기사이의 거리가 근거리(70 cm, 드림구획 : 10 segments)일 때, 오차는 원거리(90 cm, 드럼구획 : 8 segments)에서의 오차보다는 낮았는데 이는 상대적으로 1 segment에 대한 부피차이에 기인한 밀도 측정오차가 낮고 감마선의 산란이 낮았기 때문이다.

  • PDF

휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발 (Development of a Portable Device Based Wireless Medical Radiation Monitoring System)

  • 박혜민;홍현승;김정호;주관식
    • Journal of Radiation Protection and Research
    • /
    • 제39권3호
    • /
    • pp.150-158
    • /
    • 2014
  • 각 의료기관 내 방사선 관련 종사자나 방사선 치료환자들은 진단 및 치료 시 필연적으로 의료상 피폭을 수반하게 된다. 국제방사선방호위원회(ICRP) 권고나 국제원자력기구(IAEA)의 기준에 따라 기준선량 제약치를 적용 및 권고 받고 있지만 1차 피폭대상자인 종사자나 환자들의 피폭최적관리를 위해서는 잠재적인 피폭대상자들에게 기존의 피폭관리 시스템보다 직접적이고 가용성이 높은 측정 및 분석 방법이 필요하다. 따라서 본 연구에서는 기존에 구비된 휴대용 단말과 연동하여 원거리에서 실시간으로 방사선 모니터링이 가능한 시스템을 개발하였다. 모니터링 시스템은 검출부, 영상부, 통신부 세 부분으로 구성되었다. 검출부는 시스템의 소형화를 위해 실리콘 광증배소자(silicon photomultiplier) 기반 섬광검출기를 설계하였으며, 영상부는 무선 CCD (charge-coupled device)카메라 모듈을 사용하여 검출부와 함께 Bluetooth 통신모듈을 통해 휴대용 단말로 측정된 방사선 정보와 영상이 전송된다. 제작된 시스템은 성능 평가를 위해 진단용 X-ray 발생장치와 $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, $^{90}Sr$ 선원을 사용하였다. 측정결과를 통해 개발된 시스템은 gamma, beta, X-ray에 대해서 검출 반응성을 확인하였고, 방사선 세기에 따른 응답 선형성과 MCNPX 전산코드를 이용한 측정 거리에 따른 시스템의 검출 정확도 평가 시 3% 내외의 오차범위를 확인하였다. 본 연구의 결과는 방사선 검출 시스템 구성의 비용절감 효과와 개인피폭정도관리에 기여할 것으로 기대한다.

텅스텐 차폐체의 감마선 투과선량 측정 (Transmission Dose Measurement of Gamma-ray Using Tungsten Shield)

  • 한상현;구본열
    • 한국산학기술학회논문지
    • /
    • 제19권9호
    • /
    • pp.124-129
    • /
    • 2018
  • 본 연구는 Apron의 재질로 이용되고 있는 텅스텐 차폐체를 핵의학과에서 사용하는 선원의 종류와 차폐체의 두께, 선원부터 검출기 사이의 거리를 변화시켜 차폐체에 투과시킨 후 투과선량과 차폐율을 알아보고자 하였다. 실험을 위해서 선원과 차폐체와 검출기를 일직선으로 배치하고 높이 100 cm 지점에서 Inspector로 측정하였다. 그 결과 텅스텐에 차폐효과가 가장 높은 선원은 $^{201}Tl$ 선원으로 측정되었고, $^{123}I$ 선원이 $^{99m}Tc$ 선원보다 차폐효과가 높게 나타났다. 실험에 사용한 선원과 검출기 사이의 거리는 멀어질수록 투과선량은 작아졌고, 텅스텐 차폐체의 두께는 두꺼울수록 차폐율은 높게 측정되었다. 하지만 $^{131}I$$^{18}F$ 선원에서는 0.25 mmPb의 차폐체를 사용했을 경우 차폐체가 없을 경우 보다 차폐율이 감소하는 것을 확인하였다. 따라서 $^{13}1I$$^{18}F$ 선원을 사용할 경우에는 방사선 차폐효과가 높은 텅스텐일지라도 선원의 종류에 따른 특성과 차폐체의 두께를 고려하여 사용하길 권장하고, 실험 결과를 참고하여 사용한다면 피폭 저 감화방안에 도움을 줄 수 있을 것으로 생각된다.