• Title/Summary/Keyword: Gamma-ray protection

Search Result 170, Processing Time 0.024 seconds

Experimental Study on the Determination of Absorbed dose Index (흡수선량지수결정(吸收線量指數決定)에 관한 실험적(實驗的) 연구(硏究))

  • Jun, Jae-Shik;Rho, Chae-Shik;Ro, Seung-Gy;Ha, Chung-Woo;Yoo, Young-Soo;Lee, Hyun-Duk
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.34-48
    • /
    • 1982
  • The prime purpose of this study is to realize an index quantity, absorbed dose index, defined by the ICRU for the characterization of ambient radiation level at any location for the purpose of radiation protection. The experiment has been designed to be carried out in two phases, namely, preliminary and main experiment. In the primary study a 30cm diameter sphere of polyethylene was used, while in the main experiment that of tissue equivalent material was fabricated and used. Both experiments were performed in the gamma-ray fields of $^{137}Cs\;and\;^{60}Co$, and in a neutron beam of thermal column of the TRIGA MARK-II research reactor. In the measurement of gamma-ray absorbed dose TLD-700 $(^{7}LiF)$ chips were used, and for the neutron dose both Au activation foils and TLD chips (TLD-600 $(^{6}LiF)$ and TLD-700 for the discrimination of gamma-ray contribution) were used. Theoretical assessment of the absorbed dose in the sphere phantom has been carried out in accordance with the Ehrlich's idea that deduced on the basis of Burlin's cavity theory in the case of gamma-ray irradiation. For the analysis of neutron dose fluence-KERMA rate conversion method was used. The explanation on the dose assessment is given in detail. Results obtained were numerically and statistically analyzed and the depth dose distributions are presented in the graphic forms with normalized values. In the concluding remarks, the possibility and difficulty of realizing the index quantity, including questions and problems to be solved are mentioned.

  • PDF

Design of Neutron Shielder for Reducing Background of Low Level Gamma Ray Spectrometer (극저준위 감마선 분광시스템의 백그라운드 저감화를 위한 중성자 차폐체 설계)

  • Kim, Tae-Wook;Park, Jong-Mook;Park, Jong-Gil;Shin, Sang-Woon;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.67-71
    • /
    • 2001
  • In order to shield the neutrons affecting the background of Low Level Gamma Ray Spectrometer, a neutron shielder was designed. The method used in this study for neutron shielding was the deceleration of fast neutrons by high density polyethylene(HDPE) and the absorption of those slowing-down neutrons by $B_4C$. The calculation results of neutron Interaction in HDPE using Monte Carlo simulation code MCNP4B showed that the thermal-neutron flux was maximum at 10 cm thickness of HDPE. The results also showed that 95% of the thermal neutrons were absorbed by 2 mm thickness of $B_4C$ absorber Consisted of 30 w% $B_4C$ and 70 w% polymer. The results of the Monte Carlo calculation were in good agreement with the experimental value obtained by a neutron shielding apparatus designed for this purpose.

  • PDF

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

Radioprotective Effect of Extracts from Plants Indigenous to Korea

  • Kang Kyoung-Ah;Zhang Rui;Chae Sung-Wook;Piao Mei Jing;Shin Tae-Kyun;Lee Nam-Ho;Park Jae-Woo;Hyun Jin-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.115-122
    • /
    • 2006
  • We have screened the cytoprotective effect on $\gamma$-ray radiation induced oxidative stress from eighteen Korean plant extracts. Querus salicina, Clerodendron trichotomum, Lamium amplexicaule, Lozoste lancifolia and Malus baccata were found to scavenge 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical and intracellular reactive oxygen species (ROS). As a result, extracts of these plants reduced cell death of Chinese hamster lung fibroblast (V79-4) cells induced by $H_2O_2$ treatment. In addition, these extracts protected cell death of V79-4 cells damaged by $\gamma$-ray radiation. In addition, these extracts scavenged ROS generated by radiation. Taken together, the results suggest that Quercus salicina, Clerodendron trichotomum, Lamium amplexicaule, Lozoste lancifolia and Malus baccata protect V79-4 cells against oxidative damage by radiation through scavenging ROS.

Analysis of Radiation Shielding Effect of Soft Magnetic Material applied to Military Facility (경량 연자성 소재의 군 시설물 적용 시 방사선 차폐효과 분석)

  • Lee, Sangkyu;Lee, Sangmin;Choi, Gyoungjun;Lee, Byounghwak
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.191-199
    • /
    • 2021
  • The purpose of this research is to analyze the radiation shielding effect of soft magnetic material to confirm the applicability to the military facilities. The soft magnetic material is known to be effective in shielding EMP. If this material is also effective in radiation shielding, it is expected that it has a lot of applicability in military protection. In particular, this material contains boron, so it will be effective in shielding neutrons. In this research, experiments were conducted using Cs-137 and Co-60 sources to check the gamma ray shielding effect. In addition, the Monte Carlo N-Particle(MCNP) modeling was applied to evaluate the gamma ray and neutron shielding effect of a military command tent. As a result, as the soft magnetic thickness increased, the shielding performance improved according the linear attenuation law of gamma ray and neutron. Therefore, this research verified that the application of soft magnetic material for military purposes in radiation shielding would be effective.

Radiation-Induced Chromosome Aberration in Human Peripheral Blood Lymphocytes In Vitro : RBE Study with Neutrons and $^{60}Co\;{\gamma}-rays$. (KCCH cyclotron neutron 및 $^{60}Co\;{\gamma}-ray$에 의한 인체 말초혈액 임파구의 염색체 이상측정)

  • Kim, Sung-Ho;Kim, Tae-Hwan;Chung, In-Yong;Cho, Chul-Koo;Koh, Kyoung-Hwan;Yoo, Seong-Yul
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.1
    • /
    • pp.21-30
    • /
    • 1992
  • The frequencies of KCCH cyclotron neutron (30 cGy/min) or $^{60}Co\;{\gamma}-rays$ (210 cGy/min)-induced asymmetrical interchanges (dicentrics and centric rings) and acentric fragments (deletion) at several doses were measured in the normal human peripheral blood lymphocytes Chromosome aberrations were scored at the first nitosis after stimulation with phytohemagglutinin. The neutron and y-ray data were analysed on linear, power-law, quadratic and linear-quadratic model . When the dicentrics and centric rings of ${\gamma}-rays$ datas were pooled and fitted to these model, good fits were obtained to power-law $[Y=(5.81{\pm}1.96){\times}10^6D^{1.93+0.06},\; P=0.931]$, quadratic $[Y=(3.91{\pm}0.09){\times}10^{-6}D^2,\;P=0.972]$ an linear-Quadrati model $[Y=(6.55{\pm}6.83){\times}10^{-5}D+(3.72{\pm}0.22){\times}10^{-6}D^2\; P=0.922]$, except for linear model (P=0.067) As in the case of neutron data, the best fit was obtained to the linear model $(Y=(6.12{\pm}0.17){\times}10^{-3}\;D-0.22,\;P=0.987]$ and good fits were obtained to power-law$[Y=(5.36{\pm}3.02) {\times}10^{-4}D^{1.42+0.11},\; P=0.601]$ and linear-quadratic model$[Y=(2.43{\pm}0.70){\times}10^{-3}D+(1.21{\pm}0.39){\times}10^{-7}D^2$, \;P=0.415], except for quadratic model (P<0.005). The relative biological effectiveness (RBE) of neutron compared with y-ray was estimated by best fitting model. In the asymmetrical interchanges range between 0.1 and 1.5 per cell, the RBE was found to be $2.714{\pm}0.408$.

  • PDF

Comparison of nano/micro lead, bismuth and tungsten on the gamma shielding properties of the flexible composites against photon in wide energy range (40 keV-662 keV)

  • Asgari, Mansour;Afarideh, Hossein;Ghafoorifard, Hassan;Amirabadi, Eskandar Asadi
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4142-4149
    • /
    • 2021
  • In the radiation protection application, the metal-polymer composites have been developed for their radiation shielding properties. In this research, the elastomer composites doped by 10 ㎛ and 100nm size of lead, bismuth and tungsten particles as filler with 30 and 60 wt percentages were prepared. To survey the shielding properties of the polymer composites using gamma-ray emitted from 152Eu and 137Cs sources, the gamma flux was measured by using NaI(Tl) detector, then the linear attenuation coefficient was calculated. Also, the Monte Carlo simulation (MCs) method was used. The results showed a direct relationship between the linear attenuation coefficients of the absorbent and filler ratio. Also, the decrease in the particle size of the shielding material in each weight percentage improved the radiation shielding features. When the dimension of the particles was in the order of nano-size, more attenuation was achieved. At low energies used for medical diagnostic X-ray applications due to the predominance of the photoelectric effect, bismuth and lead were suitable selection as filler.