• 제목/요약/키워드: Gamma source

검색결과 670건 처리시간 0.034초

더덕 추출물의 경구 투여가 마우스의 사이토카인 생성과 IFN-${\gamma}$, IL-10 Ratio에 미치는 영향 (Effect of Codonopsis lanceolatae Extracts on Mouse IL-2, IFN-${\gamma}$, IL-10 Cytokine Production by Peritoneal Macrophage and the Ratio of IFN-${\gamma}$, IL-10 Cytokine)

  • 류혜숙
    • 한국식품영양학회지
    • /
    • 제22권1호
    • /
    • pp.69-74
    • /
    • 2009
  • Codonopsis lanceolatae have been used as one of the traditional remedies as well as food source. We previously reported that in vitro supplementation of Codonopsis lanceolatae water extracts enhanced the splenocytes proliferation compared to the control group. This study, the combined immunomodulative effect of water extract Codonopsis lanceolatae was Seven to eight weeks old mice(balb/c) was fed ad libitum on chow diet and water extract of Codonopsis lanceolatae was orally administrated every other day for four weeks at two different concentrations(50 and 500 mg/kg B.W.). The production of cytokine(IL-2, IL-10 and IFN-${\gamma}$), secreted by macrophages stimulated with LPS or not, were detected by ELISA assay using the cytokine kit. The result of ex vivo study showed that the IL-2, IL-10 and IFN-${\gamma}$ was detected at 500 mg/kg B.W. supplementation group with LPS stimulation in all cases. Also, ratio of IFN-${\gamma}$, IL-10 was the range of 3${\sim}$7 with mitogen stimulation such as Con A and LPS. In conclusion, this study suggests that Codonopsis lanceolatae extracts may enhance the immune function by regulating the cytokine(IL-2, IL-10 and IFN-${\gamma}$) prodution capacity by activated macrophages in mice.

Effect of Electron Beam and ${\gamma}$-Ray Irradiation on the Curing of Epoxy Resin

  • Kang, Phil-Hyun;Park, Jong-Seok;Nho, Young-Chang
    • Macromolecular Research
    • /
    • 제10권6호
    • /
    • pp.332-338
    • /
    • 2002
  • The effect of an electron beam and ${\gamma}$-ray irradiation on the curing of epoxy resins was investigated. Diglycidyl ether of bisphenol A (DGEBA) and diglycidyl ether of bisphenol F (DGEBF) as epoxy resin were used. The epoxy resins containing 1.0-3.() wt% of triarylsulphonium hexafluoroantimonate(TASHFA) and triarylsulphonium hexafluorophosphate(TASHFP) as initiator were irradiated under nitrogen at room temperature with different dosage of EB and ${\gamma}$-rays from a Co$^{60}$ u source. The chemical and mechanical characteristics of irradiated epoxy resins were compared after curing of EB and ${\gamma}$-ray irradiation. The thermal properties of cured epoxy were investigated using dynamic mechanical thermal analysis. The chemical structures of cured epoxy were characterized using near infrared spectroscopy. Mechanical properties such as flexural strength, modulus were measured. The gel fraction of DGEBA with ${\gamma}$-ray was higher than that of the epoxy with EB at the same dose. Young's modulus of the sample irradiated by ${\gamma}$-ray is higher than that of sample cured by EB. From the result of strain at yield, it was found that the epoxy cured by ${\gamma}$-ray had a higher stiff property compared with the irradiated by EB.

감마카메라에서의 팬텀 내 선원 위치 변화에 따른 산란 영향 평가 (The Evaluation of Scattering Effects for Various Source Locations within a Phantom in Gamma Camera)

  • 유아람;이영섭;김진수;김경민;천기정;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.216-224
    • /
    • 2009
  • $^{99m}Tc$은 핵의학 영상 획득 물리적 특성이 우수하지만 유기화 작용이 일어나지 않아 갑상선 호르몬의 합성능력이 없는 결절을 진단하는데 제한을 받는다. 이와는 달리 $^{131}I$은 유기화 작용으로 인하여 갑상선의 기능을 평가하는데 활용됨은 물론 높은 에너지의 베타선과 감마선을 방출함으로써 암의 치료에도 널리 사용되고 있는 방사선 핵종이다. 그러나 $^{131}I$은 단일에너지의 감마선을 방출하는 $^{99m}Tc$ 등과는 달리, 다양한 에너지의 감마선을 방출함으로써 핵의학 영상의 정량화가 어려운 단점이 있으며, 특히 고에너지 영역의 감마선에 의한 격벽투과와 산란선은 핵의학 진단영상에 악영향을 미치게 되는 단점이 있다. 본 연구에서는 팬텀 내에서 선원의 위치 변화에 따른 산란의 영향을 알아보기 위해 GATE (Geant4 Application for Tomographic Emission) 시뮬레이션 도구로 dual-head 감마카메라(ECAM), PMMA 팬텀(RADICAL, USA), 점선원 0.1 mCi를 사용하여 모사하였다. 팬텀 내에서 $^{131}I$ 점선원을 X축, Y축으로 위치를 변화시키며 영상을 획득하였다. 또 산란 매질의 유무에 따른 영향을 확인하기 위해 같은 위치에서 점선원이 팬텀 안에 있을 때와 공기 중에 있을 때를 비교 하였다. 저에너지 선원과 비교를 위해 같은 방법으로 $^{99m}Tc$으로도 시뮬레이션 하였다. 또한 시뮬레이션과 똑같은 환경에서 측정 실험을 통해 시뮬레이션의 타당성을 검증 하였다. 이 연구에서는 한 팬텀 내에서도 위치 변화에 따라 산란의 영향이 달라진다는 것을 시뮬레이션을 통해 확인하였다. 이러한 분포 변화는 시뮬레이션과 측정 실험 모두에서 동일한 경향을 나타내었으므로 시뮬레이션이 타당함을 확인할 수 있었다. 시뮬레이션을 이용하면 X축, Y축 위치 변화만 아닌 다양한 경우에 대해서도 위치 변화에 따른 산란 영향의 예상이 가능할 것이며 나아가 산란 보정 연구의 기초 자료로 사용될 것이라 생각한다.

  • PDF

옥수수 추출물의 경구 투여가 사이토카인 IL-2 생성과 IFN-${\gamma}$와 IL-10 Ratio에 미치는 영향 (Effect of Corn Extracts on Mouse IL-2 Cytokine Production by Peritoneal Macrophage and the Ratio of IFN-${\gamma}$, IL-10 Cytokine)

  • 류혜숙
    • 한국식품영양학회지
    • /
    • 제25권2호
    • /
    • pp.362-367
    • /
    • 2012
  • Corn has been used for a long time as a traditional remedy, as well as a food source. We previously reported that in vitro supplementation of corn water extracts enhanced the proliferation of splenocytes, compared to the control group. In this study, we examined the immunomodulative effect of a water extract of corn. Seven to eight weeks old mice(Balb/c) were fed an ad libitum chow diet, and were orally administrated a water extract of corn every other day, for four weeks, at two different concentrations(50 and 500 mg/kg B.W). Cytokine production(IL-2, IL-10 and IFN-${\gamma}$) by macrophages stimulated with LPS or not stimulated with LPS was detected by ELISA assay using the cytokine kit. In an ex vivo study, the cytokines IL-2, IL-10 and IFN-${\gamma}$ were detected at 500 mg/kg b.w. supplementation group with LPS stimulation in all cases. Also, the ratio of IFN-${\gamma}$ to IL-10 was in the range of 0~3 with mitogen stimulation, such as con A and LPS. In conclusion, this study suggests that in mice, corn extracts may enhance immune function by regulating the cytokine production(IL-2, IL-10 and IFN-${\gamma}$) of the activated macrophages.

Spatial resolution and natural image quality assessment evaluation of gamma camera image using pinhole collimator in lutetium-yttrium oxyorthosilicate scintillation detector

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2567-2571
    • /
    • 2023
  • Scintillator materials are widely used in the medical and industrial fields for imaging systems using gamma cameras. In this study, image evaluation is performed by modeling a gamma camera system based on a lutetium-yttrium oxyorthosilicate (LYSO) scintillation detector using a pinhole collimator that can improve the spatial resolution. A LYSO detector-based gamma camera system is modeled using a Monte Carlo simulation tool. The geometric concept of the pinhole collimator is designed using various magnification factors, and the spatial resolution is measured using the acquired source image. To evaluate the resolution, the full width at half maximum (FWHM) and natural image quality assessment (NIQE), a no-reference-based parameter, are used. We confirm that the FWHM and NIQE values decrease simultaneously when the diameter of the pinhole collimator increases. Additionally, we confirm that the spatial resolution improves as the magnification factor increases under the same pinhole diameter condition. Particularly, a 0.57 mm FWHM value is obtained using the modeled gamma camera system with a LYSO scintillation detector. In conclusion, our results demonstrate that a pinhole collimator with a LYSO scintillation detector is a promising gamma camera imaging system.

Development of a multi-modal imaging system for single-gamma and fluorescence fusion images

  • Young Been Han;Seong Jong Hong;Ho-Young Lee;Seong Hyun Song
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3844-3853
    • /
    • 2023
  • Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers. Therefore, intraoperative imaging studies have emerged as a surgical tool for identifying tumor margins. Intraoperative imaging has been examined using conventional imaging devices, such as optical near-infrared probes, gamma probes, and ultrasound devices. However, each modality has its limitations, such as depth penetration and spatial resolution. To overcome these limitations, hybrid imaging modalities and tracer studies are being developed. In a previous study, a multi-modal laparoscope with silicon photo-multiplier (SiPM)-based gamma detection acquired a 1 s interval gamma image. However, improvements in the near-infrared fluorophore (NIRF) signal intensity and gamma image central defects are needed to further evaluate the usefulness of multi-modal systems. In this study, an attempt was made to change the NIRF image acquisition method and the SiPM-based gamma detector to improve the source detection ability and reduce the image acquisition time. The performance of the multi-modal system using a complementary metal oxide semiconductor and modified SiPM gamma detector was evaluated in a phantom test. In future studies, a multi-modal system will be further optimized for pilot preclinical studies.

청국장에서 분리한 Bacillus subtilis GS-2에 의한 Poly(γ-Glutamic Acid) 생산의 최적 배양조건 (Influences of Culture Medium Components on the Production Poly (γ-Glutamic Acid) by Bacillus subtilis GS-2 Isolated Chungkookjang)

  • 방병호;이문수;김관필;이동희
    • 한국식품영양학회지
    • /
    • 제25권3호
    • /
    • pp.677-684
    • /
    • 2012
  • Poly-${\gamma}$-glutamic Acid(${\gamma}$-PGA)를 다량 생산하는 균주를 우리나라의 전통발효식품인 청국장으로부터 Bacillus subtilis GS-2를 분리하였다. 이 균은 glutamic acid 의존형 균으로, 이 균에 의한 ${\gamma}$-PGA 생산 최적 조건을 검토한 바, 단순배지(L-glutamic acid 2.0%, glucose 1.0%, $NH_4Cl$ 0.5%, $KH_2PO_4$ 0.05%, $MgSO_4$ $7H_2O$ 0.01%, pH 7.0)로 진탕배양(220 rpm) 하였을 때, 배양시간 48시간, 최적온도 $33^{\circ}C$, 그리고 초기 pH 6.5로 나타났다. 영양원으로 glutamic acid 3%, sucrose 3%, $NH_4Cl$ 0.25%, $KH_2PO_4$ 0.15%, $MgSO_4$ $7H_2O$ 0.015%에서 ${\gamma}$-PGA 최대 생산량이 31.0 $g/{\ell}$이었다.

중성자 핵반응을 이용한 원소 검출기술 - 즉발감마선 중성자 방사화분석법을 이용한 검출기술 - (Elemental Analysis by Neutron Induced Nuclear Reaction - Prompt Gamma Neutron Activation Analysis for Chemical Measurement -)

  • 송병철;박용준;지광용
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.1041-1051
    • /
    • 2003
  • 즉발감마선 중성자방사화법 (PGAA)은 시료내 미량 및 주원소를 빠르게 비파괴적으로 분석하는 방법으로 주로 광물, 금속, 석탄, 시멘트, 석유, 코팅, 제지 등 다양한 산업체에서 실시간 분석법으로 매우 유용하다. 이 방법은 제약과 관련된 산업체 또는 연구업무에도 활용되며, 마약 또는 폭발물과 같은 위험물질의 탐지에도 이용되고 있다. 본 총설은 즉발감마선 중성자 방사화법의 현재의 기술현황과 앞으로 연구추진 경향에 대하여 서술하였다. PGAA 시스템은 중성자 선원, 증성자 핵반응으로부터 발생하는 즉발감마선을 측정하기위한 다중채널분석기와 A/D 변환기 등의 전자모듈과 고분해능 HPGe 검출기로 구성된다. 속중성자의 콤프턴 산란에 의한 높은 바탕값은 감마-감마 동시계수장치의 도입으로 개선될 수 있다. 현재 $^{252}Cf$를 사용한 즉발감마선 중성자 방사화 장치는 수용액중에 존재하는 원소들의 실시간분석을 위해 한국원자력연구소에서 개발중에 있다. 이 장치는 다양한 마약 및 폭발물 또는 화학무기의 탐지에도 응용될 수 있다.

Characterization of a CLYC Detector and Validation of the Monte Carlo Simulation by Measurement Experiments

  • Kim, Hyun Suk;Smith, Martin B.;Koslowsky, Martin R.;Kwak, Sung-Woo;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.48-55
    • /
    • 2017
  • Background: Simultaneous detection of neutrons and gamma rays have become much more practicable, by taking advantage of good gamma-ray discrimination properties using pulse shape discrimination (PSD) technique. Recently, we introduced a commercial CLYC system in Korea, and performed an initial characterization and simulation studies for the CLYC detector system to provide references for the future implementation of the dual-mode scintillator system in various studies and applications. Materials and Methods: We evaluated a CLYC detector with 95% $^6Li$ enrichment using various gamma-ray sources and a $^{252}Cf$ neutron source, with validation of our Monte Carlo simulation results via measurement experiments. Absolute full-energy peak efficiency values were calculated for gamma-ray sources and neutron source using MCNP6 and compared with measurement experiments of the calibration sources. In addition, behavioral characteristics of neutrons were validated by comparing simulations and experiments on neutron moderation with various polyethylene (PE) moderator thicknesses. Results and Discussion: Both results showed good agreements in overall characteristics of the gamma and neutron detection efficiencies, with consistent ~20% discrepancy. Furthermore, moderation of neutrons emitted from $^{252}Cf$ showed similarities between the simulation and the experiment, in terms of their relative ratios depending on the thickness of the PE moderator. Conclusion: A CLYC detector system was characterized for its energy resolution and detection efficiency, and Monte Carlo simulations on the detector system was validated experimentally. Validation of the simulation results in overall trend of the CLYC detector behavior will provide the fundamental basis and validity of follow-up Monte Carlo simulation studies for the development of our dual-particle imager using a rotational modulation collimator.

Real-time wireless marine radioactivity monitoring system using a SiPM-based mobile gamma spectroscopy mounted on an unmanned marine vehicle

  • Min Sun Lee;Soo Mee Kim;Mee Jang;Hyemi Cha;Jung-Min Seo;Seungjae Baek;Jong-Myoung Lim
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2158-2165
    • /
    • 2023
  • Marine radioactivity monitoring is critical for taking immediate action in case of unexpected nuclear accidents at nuclear facilities located near coastal areas. Especially when the level of contamination is not predictable, mobile monitoring systems will be useful for wide-area ocean radiation survey and for determination of the level of radioactivity. Here, we used a silicon photomultiplier and a high-efficiency GAGG crystal to fabricate a compact, battery-powered gamma spectroscopy that can be used in an ocean environment. The developed spectroscopy has compact dimensions of 6.5 × 6.5× 8 cm3 and weighs 560 g. We used LoRa, a low-power wireless protocol for communication. Successful data transmission was achieved within 1.4 m water depth. The developed gamma spectroscopy was able to detect radioactivity from a 137Cs point source (3.7 kBq) at a distance of 20 cm in water. Moreover, we demonstrated an unmanned radioactivity monitoring system in a real sea by combining unmanned surface vehicle with the developed gamma spectroscopy. A hidden 137Cs source (3.07 MBq) was detected by the unmanned system at a distance of 3 m. After successfully testing the developed mobile spectroscopy in an ocean environment, we believe that our proposed system will be an effective solution for mobile real-time marine radioactivity monitoring.