• 제목/요약/키워드: Gamma camera imaging

검색결과 122건 처리시간 0.038초

Effects of Use of the Iodine Contrast Medium on Gamma Camera Imaging (요오드 조영제 사용이 감마카메라 영상에 미치는 영향)

  • Pyo, Sung-Jae;Cho, Yun-Ho;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • 제39권4호
    • /
    • pp.557-564
    • /
    • 2016
  • Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficient in an SPECT/CT attenuation correction will be considered herein. For experimental materials used $^{99m}TcO_4$ 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of $^{99m}TcO_4$. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope $^{99m}TcO_4$ and the saline solution were mixed. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and saline solution, the mean counting rate without correction by the CT absorption coefficient is $182{\pm}26counts$, while the counting rate with correction by the CT absorption coefficient is $531.3{\pm}34counts$. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were $166{\pm}29$, $158.3{\pm}17$, $154{\pm}36$, and $150{\pm}33counts$ depending on the densities of the contrast medium, while the mean values after attenuation correction were $515{\pm}03$, $503{\pm}10$, $496{\pm}31$, and $488.7{\pm}33counts$, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of dignosis.

Development of Drugs and Technology for Radiation Theragnosis

  • Jeong, Hwan-Jeong;Lee, Byung Chul;Ahn, Byeong-Cheol;Kang, Keon Wook
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.597-607
    • /
    • 2016
  • Personalized medicine is tailored medical treatment that targets the individual characteristics of each patient. Theragnosis, combining diagnosis and therapy, plays an important role in selecting appropriate patients. Noninvasive in vivo imaging can trace small molecules, antibodies, peptides, nanoparticles, and cells in the body. Recently, imaging methods have been able to reveal molecular events in cells and tissues. Molecular imaging is useful not only for clinical studies but also for developing new drugs and new treatment modalities. Preclinical and early clinical molecular imaging shows biodistribution, pharmacokinetics, mechanisms of action, and efficacy. When therapeutic materials are labeled using radioisotopes, nuclear imaging with positron emission tomography or gamma camera can be used to treat diseases and monitor therapy simultaneously. Such nuclear medicine technology is defined as radiation theragnosis. We review the current development of drugs and technology for radiation theragnosis using peptides, albumin, nanoparticles, and cells.

Performance Evaluation of Component Detectors of Double-scattering Compton Camera (이중 산란형 컴프턴 카메라 구성 검출기 성능 평가)

  • Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.69-76
    • /
    • 2010
  • Prototype double-scattering Compton camera, which consists of three gamma-ray detectors, that is, two double-sided silicon strip detectors (DSSDs) as scatterer detectors and a NaI(Tl) scintillation detector as an absorber detector, could provide high imaging resolution with a compact system. In the present study, the energy resolution and the timing resolution of component detectors were measured, and the parameters affecting the energy resolution of the DSSD were examined in terms of equivalent noise charge (ENC). The energy resolutions of the DSSD-1 and DSSD-2 were, in average, $25.2keV{\pm}0.8keV$ FWHM and $31.8keV{\pm}4.6keV$ FWHM at the 59.5 keV peak of $^{241}Am$, respectively. The timing resolutions of the DSSD and NaI(Tl) scintillation detector were 57.25 ns FWHM and 7.98 ns FWHM, respectively. In addition, the Compton image was obtained for a point-like $^{137}Cs$ gamma source with double-scattering Compton camera. From the present experiment, the imaging resolution of 8.4 mm FWHM (angular resolution of $8.1^{\circ}$ FWHM), and the imaging sensitivity of $1.5{\times}10^{-7}$ (intrinsic efficiency of $1.9{\times}10^{-6}$) were obtained.

A Study on Comparative Analysis of Mammography and Tc-99m MIBI Scintimammography for Dense Breast (치밀형 유방에서 유방특이감마영상검사의 유용성 평가)

  • Jeong, Eun-Mi;Kim, Ho-Seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제16권1호
    • /
    • pp.76-79
    • /
    • 2012
  • Purpose: This study was to evaluate usefulness of $^{99m}Tc$-MIBI scintimammography for dense breast by comparing concordance in test results between Tc-99m MIBI scintimammography and mammography whose effect was proved the most as an imaging tool depending on breast density and at the same time by examining limitation on evaluation depending on density of breast tissue. [Materials and Methods] In the period from December 2010 to July 2011, this study targeted 150 patients who took both of $^{99m}Tc$-MIBI scintimammography and mammography conducted by using breast gamma camera in this hospital. Breast density was classified to the four levels of pattern 1~4 based on the results of mammography. $^{99m}Tc$-MIBI scintimammography was conducted with the LCC, the RCC, the LMLO, and the RML one minute after intravenous injection of 99mTc-MIBI 7400 MBq (20 mCi) while analysis was made for concordance in test results of $^{99m}Tc$-MIBI scintimammography and mammography. [Results] Among the 150 patients, pattern 1 was found in 3 patients, pattern 2 in 44 patients, pattern 3 in 61 patients, and pattern 4 in 37 patients. There were 5 patients who showed the case where it was impossible to determine density of breast tissue due to foreign body inserted to breast. The concordance ratio of the results between $^{99m}Tc$-MIBI scintimammography and mammography was 95.5% for pattern 2, 95.1% for pattern 3 and 94.6% for pattern 4. This demonstrated that the concordance rate decreased according to the increase in breast density. [Conclusion] When there was limitation on evaluation of breast specific gamma imaging test results due to increased intake in breast tissue or surgical site, the concordance rate was 6.8% for pattern 2, 16.3% for pattern 3 and 18.9% for pattern 4. This demonstrated that the degree of limitation on evaluation of breast specific gamma imaging test results increased according to the increase in breast density.

  • PDF

The development of th gamma-ray imaging and operation algorithm for the gamma-ray detection system (감마선 탐지장치의 감마선 영상화 및 운용 알고리즘 개발)

  • Song, Kun-young;Hwang, Young-gwan;Lee, Nam-ho;Yuk, Young-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.942-943
    • /
    • 2016
  • Stereo gamma ray detection system generates a two-dimensional image of the gamma ray by using the position values and the gamma ray signal. And the device will overlap with the visible light image shows the actual distribution of the gamma-ray space. The gamma ray detection device is a stereo configuration to a motion controller for controlling the signal measurement unit and the position detection portion for detecting the detection portion and the gamma-ray signal comprising a gamma-ray detection sensor. In this paper, we developed a system operation management algorithm for each module individually configured efficiently. We confirmed the imaged and distribution information output for the gamma rays from gamma-ray irradiation test site by using these results.

  • PDF

Synthesis of oleyl-4[131I]-iodobenzoate for long-term cell trafficking

  • Jeon, Hak Rim;Lee, Woonghee;Oh, Jieun;Lee, Yong Jin;Yoo, Jeongsoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • 제4권2호
    • /
    • pp.45-50
    • /
    • 2018
  • Great efforts are currently devoted to the development of new approaches for the labeling of cells using appropriate radionuclides. While fluoride-18 and copper-64 have been extensively studied as short-term and intermediate-term trafficking agents, iodide was studied less intensely. Here, we report a new cell labeling agent labeled with $^{131}I$, $[^{131}I]$oleyl-4-iodobenzoate ($[^{131}I]$OIB) for long-term cell trafficking. A precursor of $[^{131}I]$OIB was obtained in two steps, with the yield of 35%. The radiochemical yield of $[^{131}I]$OIB was over 50%. While $[^{131}I]$OIB could label different cells, L6 cells showed the highest cell-labeling efficiency. The $[^{131}I]$OIB-labeled L6 cells were imprinted into a rat heart, and then monitored noninvasively for 2 weeks by gamma camera imaging. We conclude that $[^{131}I]$OIB is a good candidate molecule for a long-term cell trafficking agent.

Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

QUALITY EVALUATION OF TECHNOLOGY OF AGRICULTURAL PRODUCTS

  • Chen, Pictiaw
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.171-190
    • /
    • 1996
  • Quality evaluation of agricultural products has been a subject of interest to many researches for many years. As a results, several nondestructive techniques for quality evaluation of agricultural products have been developed. These methods are based on the detection of various physical properties that correlate well with certain quality factors of the products. This paper presents an overview of various quality evaluation techniques that are based on one of the following properties : density, firmness , vibration characteristic , X-ray and gamma ray transmission, optical reflectance and transmission , electrical properties, aromatic volatile emission, and nuclear magnetic resonance (NMR). The sophistication of nondestructive methods has evolved rapidly with modern technologies. The use of various modern image acquisition techniques, such as solid state TV camera, line-scan camera, X-ray scanning , ultrasonic scanning and NMR imaging, in conjunction with image-processing te hniques has provided new opportunities for researchers to develop many new and improved techniques for nondestructive quality evaluation of agricultural products.

  • PDF

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.