• 제목/요약/키워드: Gamma Irradiator

검색결과 59건 처리시간 0.017초

A proposed new configuration of a shuffle-dwell gamma irradiator

  • Wu, Hsingtzu
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.3176-3180
    • /
    • 2022
  • A gamma irradiator is a well-developed installation for gamma radiation sterilization. A "shuffle-dwell" mode is preferable for high dose applications. A novel configuration of a shuffle-dwell gamma irradiator is proposed to increase energy utilization and throughput, which would result in higher profitability. While the minimum distance between any irradiation position and each source pencil, the minimum distance between the neighboring irradiation positions and the size of source pencils are kept the same as the current configuration, the irradiation positions and source pencils are rearranged based on the fact that radiation is emitted in an isotropic fashion. The computational results suggest that the proposed configuration requires an 8.7% smaller area and exposes the product to 11.8% more gamma radiation in a 10.7% shorter irradiation time. In other words, the proposed configuration needs a smaller area and shorter irradiation time to have a better performance compared to the current shuffle-dwell gamma irradiator. Note that the claim is based primarily on an analytical calculation. Experimental and manufacturing among other practical considerations will be taken into account in the future work to exhaustively evaluate the performance of the proposed configuration and to compare it with that of the traditional configuration.

유리선량계를 이용한 Biobeam8000 감마선 조사장치의 선량평가 (Evaluation of Dose Distribution Using a Radiophotoluminescence Glass Dosimeter in Biobeam8000 Gamma Irradiation Device)

  • 신상훈;이성현;손기홍;이현호;김금배;정해조;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.198-205
    • /
    • 2011
  • 감마선조사장치는 세포실험, 동물실험, 혈액방사선 조사, 선량측정 실험 및 교육 등에 널리 사용되고 있다. 한국원자력의 학원에서 보유하고 있는 Biobeam8000 (STS Steuerungstechnik &. Strahlenschutz GmbH, Braunschweig, Germany, Cs-137, 81.4 TBq) 감마선 조사장치는 7.5 L의 대용량과 넓은 영역에 사용이 가능한 감마선 조사장치이다. 비커 내부에 균일한 방사선조사를 위해 Cs-137 선원이 위아래 24 cm 범위를 일정한 주기로 왕복 이동하며, 기존의 다른 감마선 조사기와 같이 시료를 넣는 비커는 방사선 조사동안 360도 회전한다. 기존의 감마선 조사기와 달리 비교적 균일한 선량이 조사되는 반면에 방사선원이 이동하므로 위치에 따른 구체적인 선량정보도 필요로 하게 된다. 본 연구에서는 유리 선량계를 이용하여 Biobeam8000 감마선 조사장치의 비커 내부 선량을 측정하였고, 측정결과를 바탕으로 선량선형성과 선량재현성에 대한 평가 및 선량분포의 정보를 도출하였다. 이 결과를 바탕으로 실험 및 방사선 조사 시 효율적인 조사장치 사용을 위한 가이드라인을 제시하고자 한다.

Cs-137 감마선에 대한 생물학 연구용 시료의 흡수선량 결정에 관한 연구 (Absorbed Dose Determination for a Biological Sample Irradiated by Gamma Rays from a Cs-137 Source)

  • 정동혁;김정기;양광모;주민수;김민영;이창열;김진호
    • 한국의학물리학회지:의학물리
    • /
    • 제22권3호
    • /
    • pp.124-130
    • /
    • 2011
  • 본 연구에서는 생물학 연구용 방사선 조사기(Gamma Irradiator, Chiyoda Technol Co., Japan)에서 방출되는 Cs-137 감마선에 대하여 선량자료 구축을 위한 선량평가를 수행하였다. 대상 시료는 직경 3 cm인 구형의 물로 가정하였으며 공기커마로부터 선량계산 체계에 따라 흡수선량을 결정하였다. 측정값의 평가를 위하여 이론적 계산 및 몬테칼로 계산(MCNPX)을 이용하여 상호 비교하였다. 측정한 공기커마는 선원과 200 cm 이내에서 이론적 계산과 3.1% 이내로 일치하였다. 최종 결정된 흡수선량은 몬테칼로 계산과 100 cm와 200 cm에서 각각 1.9% 및 3.7%의 차이를 보였다. 본 결과는 비록 단편적이지만 생물 실험용 자료구축을 위한 기초 결과로서 타당하며 추후 다양한 형태의 시료 조건에 대해서 연구를 진행해야 할 것이다.

Co60 Gamma-Ray Effects on the DAC-7512E 12-Bit Serial Digital to Analog Converter for Space Power Applications

  • Shin, Goo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2065-2069
    • /
    • 2014
  • The DAC-7512E is a 12-bit digital to analog converter that is low power and a single package with internal buffers. The DAC-7512E takes up minimal PCB area for applications of space power electronics design. The spacecraft mass is a crucial point considering spacecraft launch into space. Therefore, we have performed a TID test for the DAC-7512E 12-bit serial input digital to analog converter to reduce the spacecraft mass by using a low-level Gamma-ray irradiator with $Co^{60}$ gamma-ray sources. The irradiation with $Co^{60}$ gamma-rays was carried out at doses from 0 krad to 100 krad to check the error status of the device in terms of current, voltage and bit error status during conversion. The DAC-7512E 12-bit serial digital to analog converter should work properly from 0 krad to 30 krad without any error.

연구용 세슘-137 조사기에 대한 흡수선량 측정과 유리선량계 교정에 관한 연구 (Reference Dosimetry and Calibration of Glass Dosimeters for Cs-137 Gamma-rays)

  • 문영민;이동주;김정기;강영록;이만우;임희진;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.140-144
    • /
    • 2013
  • 본 연구에서는 방사선생물 분야에서는 사용하는 세슘-137 조사기에 대한 기준 흡수선량을 측정하고 시료의 방사선량 평가에 활용하기 위하여 유리선량계를 교정하였다. 세슘-137 감마선에 대하여 IAEA TRS-277 프로토콜을 적용하여 정밀하게 물흡수선량을 결정하였다. 기준 흡수선량 측정에는 PTW-TM300013 전리함과 PTW-TM41023 물팬텀을 사용하였으며, 유리선량계는 DoseAce사의 GD-302M 모델을 사용하였다. 교정된 유리선량계의 불확도(1 SD)는 약 2.7%로 평가되며, 본 결과는 연구용 시료의 방사선량 측정에 이용될 예정이다.

Novel polyvinyl alcohol film dosimeter containing 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide dye for high dose application

  • Khalid A. Rabaeh;Ahmed A. Basfar;Issra' M.E. Hammoudeh
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3383-3387
    • /
    • 2023
  • A new dyed polyvinyl alcohol (PVA) film dosimeter based on 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MMT) tetrazolium dye is proposed in this study for measuring high gamma radiation dose. Gamma cell irradiator that contains Co-60 gamma-ray source was used to expose the novel MMT-PVA films to different doses up to 25 kGy. The changed in optical property of irradiated and unirradiated films were characterized by UV-Vis spectrophotometer. The results show that the dose sensitive and the linear range of irradiated films were increased considerably with increase of MMT concentration from 1 to 5 mM. The dose response of dyed PVA film changed substantially with changing relative humidity (12-74%) as well as irradiation temperature (10-40 ℃). The absorbance of the unirradiated films does not change up to 10 days in dark while a significant increase in their absorbance was reported for similar films under fluorescent light. The irradiated dosimeters that kept in dark showed a perfect stability for 54 days. It was found that no obvious impact of dose rate on the irradiated MMT-PVA film dosimeters.

몬테카를로 코드를 활용한 표준 감마선 조사장치의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Standard Gamma Irradiation System Using Monte Carlo Code)

  • 박원석;허승욱;김장오;민병인
    • 한국방사선학회논문지
    • /
    • 제12권2호
    • /
    • pp.179-184
    • /
    • 2018
  • 본 연구는 표준 감마선 조사장치의 유효빔 크기를 실측과 시뮬레이션의 결과를 비교하여 유효빔 영역의 결정에 유용한 수단을 제공하고자 하였다. 시뮬레이션과 전리함을 이용한 실측의 결과는 공기커마율의 경우는 상대오차 4.5~7.3% 범위에 분포하였다. 유효빔 영역의 크기는 시뮬레이션의 경우 수평 방향 27cm, 수직 방향 21.6cm로 구현되었고, 필름을 이용한 실측결과는 수평 방향 26.5cm, 수직 방향 21.9cm로 유사한 결과가 도출되었다. 수평방향의 상대오차는 1.85%, 수직 방향은 1.38% 이며 유효빔 영역도 감마선장을 중심으로 유사하게 분포하였다. 감마선 조사장치에 있어서 시뮬레이션의 유효성이 충분함을 확인하였다. 특히 공기커마율보다 유효빔 크기의 상대오차가 적은 것은 빔의 크기가 표준선원의 용량보다는 기하학적 요인으로 결정되기 때문인 것으로 판단된다. 향후 시뮬레이션을 이용한 광자 에너지 분포도의 신뢰성을 높이기 위한 연구가 필요 할 것이다.

감마선 완·급조사에 따른 애기장대의 유전적 유연관계 분석 (Genetic Variation Analysis of Arabidopsis (Arabidopsis thaliana L.) Plants Induced by Acute and Chronic Gamma Irradiation)

  • 고은정;김진백;하보근;김상훈;강시용;김동섭
    • 방사선산업학회지
    • /
    • 제5권4호
    • /
    • pp.347-352
    • /
    • 2011
  • In order to identify the genetic relationship analysis by acute and chronic gamma irradiation, Arabidopsis (Arabidopsis thaliana L.) were irradiated with 200 Gy of gamma-rays using gamma-irradiator (3,000 Ci; Nordion, Canada) and gamma-phytotron (400 Ci; Nordion, Canada) for acute and chronic irradiation, respectively. Genetic relationship among two acute gamma-irradiated plants (A1 and A24) and three chronic gamma-irradiated plants (C1W, C2W, C3W) were analyzed using the amplified fragment length polymorphism (AFLP) technique compared with each non-irradiated plant. A total of 28 EcoRI and MseI primer combinations were used to screen 8 treatments by the ABI3130 capillary electrophoresis system. Amplified products by 28 primer sets showed 1,679 bands with an average of 51 bands per primer combination. Out of the total bands scored, 1,164 fragments were polymorphic bands, with different alleles existing among the treatments. The cluster analysis was performed using the UPGMA (Unweighted Pair Group Method using Arithmetic) in the computer program NTSYS-pc. In clustery analysis, acute gamma-irradiation showed higher genetic variation compared with chronic gamma-irradiation.

감마선 조사된 차가버섯 추출물의 암세포 활성 억제 (Tumor Cell Cytotoxicity of Gamma Irradiated Chaga Mushroom Extract)

  • 성낙윤;최종일;송범석;김재경;이주운;김진규;변명우;김미정;김재훈
    • 방사선산업학회지
    • /
    • 제5권1호
    • /
    • pp.35-39
    • /
    • 2011
  • This study was investigated the effect of tumor cell cytotoxicity of gamma irradiated Chaga mushroom extract (CME). CME was prepared by hot water extraction at $70^{\circ}C$ for 4 hours and lyophilized. $Ten\;mg\;ml^{-1}$ of lyophilized CME powder was dissolved with deionized water and then irradiated at the doses of 10, 50, 100, and 150kGy by cobalt 60 gamma irradiator. The gamma-irradiated and non-irradiated CME were treated into the cancer cell, including human stomach cancer and human colon cancer. Cytotoxicity against the cancer cell was increased in gamma-irradiated CME and antioxidant activity was also increased in gamma-irradiated CME, as irradiation dose increased. Therefore, it was considered that gamma irradiation was effective method for improvement of the cancer cell cytotoxicity and antioxidant activity of Chaga mushroom extract.

감마선 조사기술을 이용한 미량원소 비료 나노제제 제조 (Preparation of a Nanosized Micro Element Fertilizer Formulation by using Gamma-irradiation Technique)

  • 박해준;김화정
    • 방사선산업학회지
    • /
    • 제4권4호
    • /
    • pp.347-352
    • /
    • 2010
  • In this study, we addressed a novel nanosized curdlan-silica complex, which is curdlan bound to silica, for the development of a sustain-releasing micro element fertilizer formulation. The complex was obtained as follow steps; First, Curdlan polymer, sodium silicate ($Na_2SiO_3$) and isopropyl alcohol were dissolved in DDW. Next the resultant solution was irradiated by $^{60}Co$ gamma-irradiator (150 TBq of capacity; ACEL, Canada). Then $MgSO_4$ was treated with the resultant solution. The obtained colloidal solution was dried by freeze dryer. Finally, we obtained a novel nanosized curdlan-silica formulation containing $MgSO_4$ from the colloidal solution. The morphology of the complex was characterized by using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The nanosized curdlan-silica complex has a particle size ranging from 20 to 80 nm and high stability. Our results suggested that the nano-complex can be applicable to use in various sustain-releasing formulation for pesticide delivery system (PDS).