• 제목/요약/키워드: Gamma Detection

검색결과 534건 처리시간 0.036초

수중 내 베타선 모니터링 센서 개발을 위한 기초연구 (Feasibility Study on Development of an Underwater Beta-ray Monitoring Sensor)

  • 박혜민;주관식
    • 센서학회지
    • /
    • 제25권5호
    • /
    • pp.333-336
    • /
    • 2016
  • In this study, a beta monitoring sensor was developed as a part of basic research for quantitative beta monitoring underwater, and its performance was evaluated using a calibration source. A beta detection sensor was manufactured by using SiPM(silicon photomultiplier) and $CaF_2$:Eu, YAG:Ce, YAP:Ce scintillator. A large-area light guide was introduced to improve beta-ray detection efficiency. As calibration sources, the Beta source $^{90}Sr$, which is the main fission product of a nuclear accident, and the gamma source $^{137}Cs$ are used. In the performance evaluation, it is confirmed that scintillator $CaF_2:Eu$ gives the highest beta-ray detection response. Compared to gamma ray, beta-ray detection responsivity and detection efficiency are verified. Therefore, this study is expected to contribute to basic research in the development of an underwater beta-ray monitoring system.

다종 감마선 공간분포 측정을 위한 고감도 검출센서 및 탐지모듈 개발 (Development of High-Sensitivity Detection Sensor and Module for Spatial Distribution Measurement of Multi Gamma Sources)

  • 황영관;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.705-707
    • /
    • 2017
  • 스테레오기반의 공간방사선 탐지장치는 방사선원에 대한 공간분포정보 뿐만 아니라 탐지장치로부터 선원까지의 거리정보를 얻을 수 있어 기존 방사선 영상화 장치보다 선원에 대한 효율적인 정보를 제공한다. 또한 감마선원의 스펙트럼 및 종류에 대한 정보를 고속으로 제공하기 위해서는 감도가 높은 고감도 검출센서가 필요하며 고선량에서의 포화되는 현상을 해소할 수 있는 기법이 필요하다. 본 논문에서는 다종 감마선 공간분포 측정을 위해 고감도 센서를 구성하고, 검출모듈의 기능을 개선하여 고선량에서의 포화상태를 해소함으로써 단일센서로 탐지범위 증대를 위한 연구를 수행하였다. 본 논문의 결과는 향후 스테레오기반의 감마선 탐지장치의 성능개선을 위해 활용될 것이다.

  • PDF

스테레오 기반 감마선원 탐지 및 가시화에 관한 연구 (Study of the Radioactive Source Detection and the Visualization with the Stereo Radiation Detector)

  • 박강택;이남호;차한주
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1100-1102
    • /
    • 2015
  • 본 논문에서는 스테레오 기반 감마선원 탐지장치를 통해 감마선원을 포함하는 공간을 래스터 스캔방식으로 스캔하여 가시광영상과 감마선영상을 획득하고, 스테레오 감마선 탐지장치로부터 선원까지의 거리와 방향에 대한 3차원 정보 획득 및 가시화를 수행하였다. 탐지장치의 구성은 감마선원 탐지를 위한 방사선 검출부, 선원탐지를 위해 래스터스캔방식의 스캔을 위한 팬틸트 그리고 가시광영상을 위한 CCD 카메라로 이루어진다. 선원에 대한 공간분포를 측정하기 위해 스테레오 구조의 장치를 구현하였으며 스테레오 영상획득을 위해 CCD 카메라와 감마선 탐지장치는 각각 2대로 구성하였다. 탐지선원에 대한 분포를 나타내기 위해 감마선 탐지 장치와 가시광 카메라에 대한 보정을 수행하였고, 각각의 카메라에 대한 스테레오 보정을 수행한 후 가시광영상과 감마선영상 중첩을 통해 감마선원에 대한 분포를 나타내었다. 좌, 우 분포영상에 대한 정류화처리 후 스테레오 영상에 대한 가시화결과를 도출하였다.

  • PDF

Improved fast neutron detection using CNN-based pulse shape discrimination

  • Seonkwang Yoon;Chaehun Lee;Hee Seo;Ho-Dong Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.3925-3934
    • /
    • 2023
  • The importance of fast neutron detection for nuclear safeguards purposes has increased due to its potential advantages such as reasonable cost and higher precision for larger sample masses of nuclear materials. Pulse-shape discrimination (PSD) is inevitably used to discriminate neutron- and gamma-ray- induced signals from organic scintillators of very high gamma sensitivity. The light output (LO) threshold corresponding to several MeV of recoiled proton energy could be necessary to achieve fine PSD performance. However, this leads to neutron count losses and possible distortion of results obtained by neutron multiplicity counting (NMC)-based nuclear material accountancy (NMA). Moreover, conventional PSD techniques are not effective for counting of neutrons in a high-gamma-ray environment, even under a sufficiently high LO threshold. In the present work, PSD performance (figure-of-merit, FOM) according to LO bands was confirmed using a conventional charge comparison method (CCM) and compared with results obtained by convolution neural network (CNN)-based PSD algorithms. Also, it was attempted, for the first time ever, to reject fake neutron signals from distorted PSD regions where neutron-induced signals are normally detected. The overall results indicated that higher neutron detection efficiency with better accuracy could be achieved via CNN-based PSD algorithms.

방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작 (Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent)

  • 김정호;박혜민;주관식
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

Feasibility study of β-ray detection system for small leakage from reactor coolant system

  • Jang, Jaeyeong;Jeong, Jae Young;Park, Junesic;Cho, Young-Sik;Pak, Kihong;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2748-2754
    • /
    • 2022
  • Because existing reactant coolant system (RCS) leakage detection mechanisms are insensitive to small leaks, a real-time, direct detection system with a detection threshold below 0.5 gpm·hr-1 was studied. A beta-ray detection system using a silicon detector with good energy resolution for beta rays and a low gamma-ray response was proposed. The detection performance in the leakage condition was evaluated through experiments and simulations. The concentration of 16N in the coolant corresponding to a coolant leakage of 0.5 gpm was calculated using the analytic method and ORIGEN-ARP. Based on the concentration of 16N and the measurement of the silicon detector with 90Sr/90Y, the beta-ray count rate was estimated using MCNPX. To evaluate the effect of gamma rays inside the containment building, the signal-to-noise ratio (SNR) was calculated. To evaluate the count rate ratio, the radiation field inside the containment building was simulated using MCNPX, and response evaluation experiments were performed using beta and gamma rays on the silicon detector. The expected beta-ray count rate at 0.5 gpm leakage was 7.26 × 105 counts/sec, and the signal-to-background count rate ratio exceeded 88 for a transport time of 10 s, demonstrating its suitability for operation inside a reactor containment building.

Application of Artificial Neural Networks to Search for Gravitational-Wave Signals Associated with Short Gamma-Ray Bursts

  • Oh, Sang Hoon;Kim, Kyungmin;Harry, Ian W.;Hodge, Kari A.;Kim, Young-Min;Lee, Chang-Hwan;Lee, Hyun Kyu;Oh, John J.;Son, Edwin J.
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.107.1-107.1
    • /
    • 2014
  • We apply a machine learning algorithm, artificial neural network, to the search for gravitational-wave signals associated with short gamma-ray bursts. The multi-dimensional samples consisting of data corresponding to the statistical and physical quantities from the coherent search pipeline are fed into the artificial neural network to distinguish simulated gravitational-wave signals from background noise artifacts. Our result shows that the data classification efficiency at a fixed false alarm probability is improved by the artificial neural network in comparison to the conventional detection statistic. Therefore, this algorithm increases the distance at which a gravitational-wave signal could be observed in coincidence with a gamma-ray burst. We also evaluate the gravitational-wave data within a few seconds of the selected short gamma-ray bursts' event times using the trained networks and obtain the false alarm probability. We suggest that artificial neural network can be a complementary method to the conventional detection statistic for identifying gravitational-wave signals related to the short gamma-ray bursts.

  • PDF

Study of n/γ discrimination using 3He proportional chamber in high gamma-ray fields

  • Choi, Joonbum;Park, Junesic;Son, Jaebum;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.263-268
    • /
    • 2019
  • The $^3He$ proportional chamber is widely used for neutron measurement owing to its high neutron detection efficiency and simplicity for gamma-ray rejection. In general, the neutron and gamma-ray signals obtained from the $^3He$ proportional chamber can be easily separated by the difference in the pulse heights. However, for a high gamma-ray field, the gamma-ray signal cannot be precisely eliminated by the pulse height due to gamma-ray pulse pileup which causes the pulse height of gamma-ray pulse to increase and making the pulses due to neutrons and gamma rays indistinguishable. In this study, an improved algorithm for $n/{\gamma}$ discrimination using a parameter, which is the ratio of the rise time to the pulse height, is proposed. The $n/{\gamma}$ discrimination performance of the algorithm is evaluated by applying it to $^{252}Cf$ neutron signal separation from various gamma-ray exposure rate levels ranging 0.1-5 R/h. The performance is compared to that of the conventional pulse-height analysis method in terms of the gamma elimination ratio. The suggested algorithm shows better performance than the conventional one by 1.7% (at 0.1 R/h) to 70% (at 5 R/h) for gamma elimination.

복잡한 FLIR 영상에서의 소형 표적 탐지 기법 (Small Target Detection Method under Complex FLIR Imagery)

  • 이승익;김주영;김기홍;구본호
    • 한국멀티미디어학회논문지
    • /
    • 제10권4호
    • /
    • pp.432-440
    • /
    • 2007
  • 본 논문에서는 복잡한 배경을 가지는 전방 관측 열상(FLIR; forward looking infrared) 영상에서의 소형 표적 탐지 기법을 제안하였다. 제안한 기법에서는 먼저 이전 프레임과 현재 프레임의 차를 구하여 표적의 움직임 정보를 획득할 뿐만 아니라 시간적으로 발생하는 배경 잡음을 제거한다. 이때 먼 거리에서 다가오는 표적이나 속도가 느린 표적의 경우 차 영상 내에서의 표적의 움직임 정보는 매우 작은 명암도 값을 가진다. 이런 작은 명암도 값을 두드러지게 하여 표적 탐지를 용이하게 하기 위하여 프레임 차 영상에 국부 감마교정을 행한다. 이렇게 표적이 개선된 영상에서 국부적인 통계적인 특성을 이용하여 탐지 지표를 계산한 후 가장 낮은 탐지 지표 값을 탐지하고자하는 표적으로 선정한다. 실험을 통하여 제안한 기법이 표적의 탐지성능이 기존의 탐지기법보다 우수하였음을 확인하였다.

  • PDF

중성자 핵반응을 이용한 원소 검출기술 - 즉발감마선 중성자 방사화분석법을 이용한 검출기술 - (Elemental Analysis by Neutron Induced Nuclear Reaction - Prompt Gamma Neutron Activation Analysis for Chemical Measurement -)

  • 송병철;박용준;지광용
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.1041-1051
    • /
    • 2003
  • 즉발감마선 중성자방사화법 (PGAA)은 시료내 미량 및 주원소를 빠르게 비파괴적으로 분석하는 방법으로 주로 광물, 금속, 석탄, 시멘트, 석유, 코팅, 제지 등 다양한 산업체에서 실시간 분석법으로 매우 유용하다. 이 방법은 제약과 관련된 산업체 또는 연구업무에도 활용되며, 마약 또는 폭발물과 같은 위험물질의 탐지에도 이용되고 있다. 본 총설은 즉발감마선 중성자 방사화법의 현재의 기술현황과 앞으로 연구추진 경향에 대하여 서술하였다. PGAA 시스템은 중성자 선원, 증성자 핵반응으로부터 발생하는 즉발감마선을 측정하기위한 다중채널분석기와 A/D 변환기 등의 전자모듈과 고분해능 HPGe 검출기로 구성된다. 속중성자의 콤프턴 산란에 의한 높은 바탕값은 감마-감마 동시계수장치의 도입으로 개선될 수 있다. 현재 $^{252}Cf$를 사용한 즉발감마선 중성자 방사화 장치는 수용액중에 존재하는 원소들의 실시간분석을 위해 한국원자력연구소에서 개발중에 있다. 이 장치는 다양한 마약 및 폭발물 또는 화학무기의 탐지에도 응용될 수 있다.