• 제목/요약/키워드: Gamma Detection

검색결과 546건 처리시간 0.028초

Daily adaptive proton therapy: Feasibility study of detection of tumor variations based on tomographic imaging of prompt gamma emission from proton-boron fusion reaction

  • Choi, Min-Geon;Law, Martin;Djeng, Shin-Kien;Kim, Moo-Sub;Shin, Han-Back;Choe, Bo-Young;Yoon, Do-Kun;Suh, Tae Suk
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.3006-3016
    • /
    • 2022
  • In this study, the images of specific prompt gamma (PG)-rays of 719 keV emitted from proton-boron reactions were analyzed using single-photon emission computed tomography (SPECT). Quantitative evaluation of the images verified the detection of anatomical changes in tumors, one of the important factors in daily adaptive proton therapy (DAPT) and verified the possibility of application of the PG-ray images to DAPT. Six scenarios were considered based on various sizes and locations compared to the reference virtual tumor to observe the anatomical alterations in the virtual tumor. Subsequently, PG-rays SPECT images were acquired using the modified ordered subset expectation-maximization algorithm, and these were evaluated using quantitative analysis methods. The results confirmed that the pixel range and location of the highest value of the normalized pixel in the PG-rays SPECT image profile changed according to the size and location of the virtual tumor. Moreover, the alterations in the virtual tumor size and location in the PG-rays SPECT images were similar to the true size and location alterations set in the phantom. Based on the above results, the tumor anatomical alterations in DAPT could be adequately detected and verified through SPECT imaging using the 719 keV PG-rays acquired during treatment.

An Improved Movable 3 photomultiplier (3PM)-γ Coincidence Counter Using Logical Sum of Double Coincidences in β-Channel for Activity Standardization

  • Hwang, Han Yull;Lee, Jong Man
    • Journal of Radiation Protection and Research
    • /
    • 제45권2호
    • /
    • pp.76-80
    • /
    • 2020
  • Background: To improve the measurement accuracy of liquid-scintillation counting for activity standardization, it is necessary to significantly reduce the background caused by thermal noise or after-pulses. We have therefore improved a movable 3 photomultiplier (3PM)-γ coincidence-counting method using the logical sum of three double coincidences for β events. Materials and Methods: We designed a new data-acquisition system in which β events are obtained by counting the logical sum of three double coincidences. The change in β-detection efficiency can be derived by moving three photomultiplier tubes sequentially from the liquid-scintillation vial. The validity of the method was investigated by activity measurement of 134Cs calibrated at the Korea Research Institute of Standards and Science (KRISS) with 4π(PC)β-γ(NaI(Tl)) coincidence counting using a proportional counter (PC) for the β detector. Results and Discussion: Measurements were taken over 14 counting intervals for each liquidscintillation sample by displacing three photomultiplier tubes up to 45 mm from the sample. The dead time in each β- and γ-counting channel was adjusted to be a non-extending type of 20 ㎲. The background ranged about 1.2-3.3 s-1, such that the contributions of thermal noise or after-pulses were negligible. As the β-detection unit was moved away from the sample, the β-detection efficiencies varied between 0.54 and 0.81. The result obtained by the method at the reference date was 396.3 ± 1.7 kBq/g. This is consistent with the KRISS-certified value of 396.0 ± 2.0 kBq/g within the uncertainty range. Conclusion: The movable 3PM-γ method developed in the present work not only succeeded in reducing background counts to negligible levels but enabled β-detection efficiency to be varied by a geometrical method to apply the efficiency extrapolation method. Compared with our earlier work shown in the study of Hwang et al. [2], the measurement accuracy has much improved. Consequently, the method developed in this study is an improved method suitable for activity standardization of β-γ emitters.

지표면 침적 방사성핵종에 대한 NaI(Tl), LaBr3(Ce) 및 CeBr3 검출기의 MDA 비교 평가 (MDA Assessment of NaI(Tl), LaBr3(Ce), and CeBr3 Detectors for Freshly Deposited Radionuclides on the Soil)

  • 이준호;김봉기;이동명;변종인
    • 방사성폐기물학회지
    • /
    • 제17권3호
    • /
    • pp.321-328
    • /
    • 2019
  • 본 연구에서는 원자력 사고 또는 방사선 비상 시 지표면에 침적될 수 있는 감마선방출 핵종의 방사능을 신속하게 평가하기 위해 이용될 수 있는 NaI(Tl), $LaBr_3$(Ce) 및 $CeBr_3$ 섬광검출기의 성능을 비교 평가하였다. 검출성능은 최소검출가능방사능(MDA, Minimum Detectable Activity)을 통해 평가하였으며, 각 검출기의 지표면 침적 감마선방출 핵종에 대한 검출효율은 수학적 모델링과 점선원을 이용하여 반실험적으로 산출하였다. MDA 평가를 위한 백그라운드 감마선에너지스펙트럼은 비교적 넓고 평탄한 초지에서 측정되었으며, 원자력 사고 시 방출될 수 있는 주요 핵종에 대한 각 검출기의 MDA를 산출하였다. 그 결과 일반 환경방사능 준위에서 지표면 침적 감마핵종에 대한 각 검출기의 MDA 크기는 대체로"NaI(Tl)> $LaBr_3$(Ce)> $CeBr_3$"로 평가되었으며, 백그라운드 준위가 유사한 에너지 영역에서는 분해능이 가장 우수한 $LaBr_3$(Ce)에서 최소 값을 보였다. 이는 관심 핵종의 감마선에너지 영역에 대한 각 검출기의 자체 및 측정 환경 백그라운드, 측정 효율, 그리고 에너지 분해능 특성을 바탕으로 비교 분석되었다.

이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발 (Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution)

  • 박종훈;이한림;김찬형;김성훈;김성훈;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.42-51
    • /
    • 2015
  • 양성자 치료 시 양성자 빔을 사용하여 정밀한 치료를 수행하고 환자의 안전을 제고하기 위해서는 인체 내 양성자 빔의 선량 분포를 확인하는 것이 중요하다. 이를 위해 본 연구팀은 이전 연구에서 1차원 배열형 검출기를 종형으로 배치하여 빔 진행방향으로 이동시켜가면서 2차원적인 즉발감마선 분포를 측정하여 양성자 선량 분포와 유사한 분포를 갖는 것을 확인하였다. 본 연구에서는 이를 바탕으로 즉발감마선 이차원분포를 실시간으로 측정하기 위해 이차원 평행다공형 집속 장치, 이차원 배열의 NaI(Tl) 섬광체와 MA-PMT로 이루어진 즉발감마선 이차원분포 측정 장치를 개발하였다. 개발한 즉 발감마선 이차원분포 측정 장치의 성능을 평가한 결과 $^{22}Na$ 감마선원의 에너지 분해능은 $10.9%{\pm}0.23p%$ (0.511 MeV)와 $6.4%{\pm}0.24p%$ (1.275 MeV)로 평가되었으며, $^{137}Cs$$9.8%{\pm}0.18p%$ (0.662 MeV)로 평가되었다. 고에너지 Am-Be 선원의 double escape 피크인 3.416 MeV의 에너지 분해능은 $11.4%{\pm}3.6p%$로 평가되었다. 본 측정 장치를 이용하여 45 MeV 양성자 빔을 PMMA에 조사하여 발생한 즉발감마선 이차원분포를 측정한 결과 0.5 nA의 세기의 양성자 빔에서 $9{\times}10^9$ 양성자 조사 시 양성자 선량 분포와 유사한 즉발감마선 이차원분포를 측정할 수 있음을 확인하였다. 추가로 측정한 즉발감마선 이차원분포의 프로파일 분포를 이용하여 양성자 빔의 비정을 평가해 본 결과 $17.0{\pm}0.4mm$로 평가되었고, 실제 비정인 17.4 mm과 굉장히 밀접한 관련이 있음을 확인하였다.

Cortex-A9 기반 휴대용 방사선 검출장치에서의 분해능 향상을 위한 연구 (Research of Resolution enhancement from portable radiation detection platform based on Cortex-A9)

  • 권태경;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.373-376
    • /
    • 2014
  • 전 세계적으로 해운물류 안전 보안체계가 강화됨에 따라 국가물류보안 체계 구축을 위한 해운물류 안전 보안 핵심기술 개발이 이루어지고 있다. 이러한 국제적 정서에 발맞추어, 국내에서도 감마선 핵종을 검출할 수 있는 휴대용 방사선 검출 장치에 대한 관심이 높아지고 있다. 본 논문에서는 Cortex-A9을 이용한 휴대용 방사선 검출장치 플랫폼 검출 성능의 향상을 위한 연구를 제안한다.

  • PDF

An electrochemical hydrogen peroxide sensor for applications in nuclear industry

  • Park, Junghwan;Kim, Jong Woo;Kim, Hyunjin;Yoon, Wonhyuck
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.142-147
    • /
    • 2021
  • Hydrogen peroxide is a radiolysis product of water formed under gamma-irradiation; therefore, its reliable detection is crucial in the nuclear industry for spent fuel management and coolant chemistry. This study proposes an electrochemical sensor for hydrogen peroxide detection. Cysteamine (CYST), gold nanoparticles (GNPs), and horseradish peroxidase (HRP) were used in the modification of a gold electrode for fabricating Au/CYST/GNP/HRP sensor. Each modification step of the electrode was investigated through electrochemical and physical methods. The sensor exhibited strong sensitivity and stability for the detection and measurement of hydrogen peroxide with a linear range of 1-9 mM. In addition, the Michaelis-Menten kinetic equation was applied to predict the reaction curve, and a quantitative method to define the dynamic range is suggested. The sensor is highly sensitive to H2O2 and can be applied as an electrochemical H2O2-sensor in the nuclear industry.

Changes in Thermoluminescence of Mineral Separated from Irradiated Shellfish under Various Storage Conditions

  • Yi, Sang-Duk;Yang, Jae-Seung
    • Preventive Nutrition and Food Science
    • /
    • 제6권1호
    • /
    • pp.23-28
    • /
    • 2001
  • A study was carried out to establish a detection method of irradiated shellfish through thermoluminescence (TL). The TL intensity of first glow curves for irradiated bloody, freshwater, and short-neck shellfish increased from control until 5 kGy and increased slightly room 5 kGy until 10 kGy. Maximum TL temperatures of all irradiated samples tested were below 23$0^{\circ}C$, within temperature interval of 150~25$0^{\circ}C$ recommended for evaluation. Since just in control, glow curve ratios of G3 and G4 calculated from re-irradiated (1 kGy) bloody, freshwater and shortneck were over 0.5, detection in control was possible. However, as glow curve ratios after three months were below 0.5, detection by glow curve ratios after three months was impossible. Gl, which calculated from unirradiated samples, exhibited below 0.1, they were classified as unirradiated. In all samples, all the irradiated shellfish could be classified correctly as irradiated by hemaximum TL temperatures and shape of the second glow curve because those were shown in a lower temperature region than those of the first glow curve.

  • PDF

In situ PCR에 의한 alcelaphine herpesvirus-l (AHV-l)의 진단법 개발 및 다른 분자생물학적 진단법들과의 비교 (In situ PCR for the Detection of Alcelaphine Herpesvirus-l and Comparison with other Molecular Biological Diagnostic Methods)

  • 김옥진
    • 한국수의병리학회지
    • /
    • 제6권1호
    • /
    • pp.1-5
    • /
    • 2002
  • A1celaphine herpesvirus 1 (AHV-1) is a causative agent of malignant catarrhal fever which is a fatal and a lymphoproliferative syndrome. AHV-1 is a gamma herpesvirus, which induces frequent latent infection and often difficult to detect its antigens or specific nucleic acids because of its low viral copies in the infected tissues. A new method, in situ PCR, is developed for the detection of AHV-1 nucleic acid in this study. Target sequences of AHV-1 open reading frame 50 gene were detected within AHV-1 infected MDBK cells. As compare with other molecular biological methods for the detection of AHV-1, in situ PCR was found to be more sensitive than in situ hybridization and to be less sensitive than nested PCR. However, nested PCR cannot afford to observe and differentiate AHV-1 infected cells. In situ PCR amplifies a target sequence within cells that can be visualized microscopically with increased sensitivity compared to detection by in situ hybridization. In situ PCR has wide applications for sensitive localization of low copy AHV-1 viral sequences within cells to investigate the role of viruses in a variety of clinical conditions and also provide the rapid, sensitive, and specific detection of AHV-1 infection.

  • PDF

Detection of Irradiated Cereals by Viscosity Measurement

  • Yi, Sang-Duk;Chang, Kyu-Seob;Yang, Jae-Seung
    • Preventive Nutrition and Food Science
    • /
    • 제5권2호
    • /
    • pp.93-99
    • /
    • 2000
  • A study was performed to establish the detection method of irradiated cereals. A drastic reduction of the apparent viscosity of suspensions with heat treatment was observed up to 1∼2 kGy in brown rice, Job's-tears, polished barley and polished rice. They were gently reduced to samples irradiated at 15 kGy. This trend was similar for all stirring speeds. The viscosity of unirradiated brown rice, Job's-tears, polished barley and polished rice reduced with in-creasing stirring speeds and this tendency was similar for irradiation doses. Regression expressions and coefficients of brown rice, Job's s-tears, polished barley and polished rice on different doses were 0.9399($y=3408.0e^{-0.2338x}$), 0.8855($y=3597.8e^{-0.6864x}$), 0.9343($y=7554.0e^{-0.4998x}$) and 0.9714($y=3228.2e^{-0.5312x}$), respectively, at 120 rpm. These results sug-gest that detection of irradiation for cereals could be possible by viscometric methods.

  • PDF

Detection of Iron Phases Presents in Archaeological Artifacts by Raman Spectroscopy

  • Barbosa, A.L.;Jimenez, C.;Mosquera, J.A.
    • Corrosion Science and Technology
    • /
    • 제17권2호
    • /
    • pp.60-67
    • /
    • 2018
  • The compounds associated with corrosion, in metallic archaeological samples of carbon steel of insular origin were evaluated to establish their degree of deterioration and structural damage against air pollution. The iron phases present in samples of archaeological artifacts were detected by Raman spectroscopy and confocal Raman microcopy. These samples mainly exhibited ing mainly ${\beta}$-FeO(OH) type goethite oxyhydroxides and small amounts of akaganeite ${\alpha}$-FeO(OH) lepidocrocite ${\gamma}$-FeO(OH) due to dominant chloride in a marine environment and non-stoichiometric oxyhydroxides Fe (II + / III +) as indicators of early corrosion. Some parts showed the presence of magnetic maghemite indicating high corrosion. ${\gamma}$-FeO(OH) is a precursor of phases associated with advanced marine corrosion. By studying its decomposition by Raman spectroscopy, it was synthesized with the following sequence: ${\gamma}-FeO(OH){\rightarrow}{\alpha}-FeO(OH)+{\gamma}-FeO(OH)$, ${\rightarrow}{\gamma}-Fe_2O_3+Fe_3O_4$. Ferric compounds provided evidence for the effect of intensity of laser on them, constituting a very useful input for the characterization of oxidation of iron in this type of artifacts. Thus, destructive analysis techniques should be avoided in addition to the use of small amounts of specimen.