• Title/Summary/Keyword: Gait Characteristics

Search Result 262, Processing Time 0.021 seconds

The Correlations among the Dynamic Gait Index the Berg Balance Scale and Timed Up & Go Test in people with stroke (뇌졸중 환자에서 Dynamic Gait Index와 Berg Balance Scale 및 Timed Up & Go 검사간의 상관관계)

  • Lee, Sang-Ho;Hwang, Byoung-Yong
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.3
    • /
    • pp.1-8
    • /
    • 2008
  • The purpose of this study was to compare the relationship among the Dynamic Gait Index(DGI), Berg Balance Scale(BBS) scores, Timed Up & Go Test(TUG), and subject characteristics. The subjects were fifteen stroke with hemiplegia were chosen in the Konyang University Hospital. Dynamic balance was measured Dynamic Gait Index(DGI), and balance was measured using Berg Balance Scale(BBS). Timed Up & Go Test(TUG) was used to evaluate functional mobility. Data were analyzed using Spearman correlation. There was significant correlated among Dynamic Gait Index(DGI), Berg Balance Scale(BBS) and Timed Up & Go Test(TUG)(p<.01). The correlation among subject characteristics and Dynamic Gait Index(DGI), Berg Balance Scale(BBS), Timed Up & Go Test(TUG) score was significant result in r = -.527 from Dynamic Gait Index(DGI) and pathogenesis(p<.05). There were no significant statistical differences among the types of spasticity and Dynamic Gait Index(DGI), Berg Balance Scale(BBS), Timed Up & Go Test(TUG). The comparison among the sex, type of hemiplegia, pain, pathogenesis and Dynamic Gait Index(DGI), Berg Balance Scale(BBS), Timed Up & Go Test(TUG) score was significant result in pathogenesis(p<.05). The results of this study showed that there was high correlations among the Dynamic Gait Index(DGI) and balance test of people with stroke.

  • PDF

Validation of the Korean Functional Gait Assessment in Patients With Stroke (뇌졸중 환자를 대상으로 실시한 한글판 기능적 보행평가의 타당도)

  • Park, So-yeon
    • Physical Therapy Korea
    • /
    • v.23 no.2
    • /
    • pp.35-43
    • /
    • 2016
  • Background: The Functional Gait Assessment (FGA) was developed to measure of gait-related activities. The FGA was translated in Korean but only a few psychometric characteristics had been studied. Objects: The purpose of this study was to evaluate the validity and reliability of the Korean version of FGA scale using Rasch analysis. Methods: The study included 120 patients with stroke (age range=30~83 years; mean${\pm}$standard deviation=$58.3{\pm}11.1$). The FGA and Berg Balance Scale were performed, and were analysed for dimensionality of the scale, item difficulty, scale reliability and separation, and item-person map using Rasch analysis. Results: The 4 rating scale categories of FGA were satisfied with optimal rating scale criteria. The most items of the FGA showed sound item psychometric properties except 2 items ('gait with the horizontal head turns', and 'gait with narrow base of support'), and the 2 misfit items were excluded for all further analyses. The 8 items were arranged in order of difficulty. The most difficult item was 'gait with eyes closed', the middle difficult item was 'gait level surface', and the easiest item was 'gait with vertical head turns.' A person separation reliability was .93 and the person separation index was 3.57. Conclusion: This study suggests that the 8-item Korean FGA are valid measure of assess the gait-related balance performance, and to set the goal of rehabilitation plan in patient with stroke.

Comparison Gait Analysis of Normal and Amputee: Filtering Graph Data Based on Joint Angle

  • Junhyung Kim;Seunghyun Lee;Soonchul Kwon
    • International journal of advanced smart convergence
    • /
    • v.12 no.3
    • /
    • pp.61-67
    • /
    • 2023
  • Gait analysis plays a key role in the research field of exploring and understanding human movement. By quantitatively analyzing the complexity of human movement and the various factors that influence it, it is possible to identify individual gait characteristics and abnormalities. This is especially true for people with walking difficulties or special circumstances, such as amputee, for example. This is because it can help us understand their gait characteristics and provide individualized rehabilitation plans. In this paper, we compare and analyze the differences in ankle joint motion and angles between normal and amputee. In particular, a filtering process was applied to the ankle joint angle data to obtain high accuracy results. The results of this study can contribute to a more accurate understanding and improvement of the gait patterns of normal and amputee.

A Study of Motor Expertise about Kinematic and Kinetic Characteristics of Lower Extremity in the Seokmun Ilwol Martial Art Yin-yang Bo Gait Pattern (석문일월무예 음양보법의 숙련성에 따른 보행 패턴의 하지 운동학 및 운동역학적 특성)

  • Park, Bok-Hee;Kim, Ky-Hyoung
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.239-248
    • /
    • 2014
  • The purpose of this study was to quantify kinematic and kinetic characteristics of Yin-yang Bo gait according to their motor expertise, one of the Seokmun Ilwol martial art gait patterns. Yin-yang Bo gait pattern shows initial forefoot contact instead of heel contact, and increased time of stance phase time, internal-external rotation of ankle-knee-hip joints and pelvic. It aims to produce and store the more energy through continuous homeostasis of center of gravity (COG) and performance of stretch-shortening cycle. Some of these characteristics also were similar to the gait modification strategies for reducing knee adduction moment such as toe-out progression, medial thrust, internal rotation of hip joint. To identify the characteristics, four factors of expert Yin-yang Bo gait performance group were compared to that of none expert group; 1) angles of COG displacement and rotation 2) distal joint pre-rotation in internal-external rotation of ankle-knee-hip joints and pelvic, 3) invariability pelvic potential and pelvic segment total energy 4) knee abduction moment. Six healthy(three male) subjects participated in the experiment to perform Yin-yang gait pattern. Three-dimensional and force plate data were collected. Kinematic and kinetic data were compared between two groups using t-tests. Results showed that 1) the peak point of COG internal rotation angle was reduced in expert group, 2) kneeexternal and hip joint -internal and pelvic rotation angle peak frames were more near points in expert group.

Spatiotemporal characteristics of stroke patients gait (뇌졸중 환자에서 보행의 시공간적 특징)

  • Lee, Sangkwan;Choi, Sanho;Oh, Jaegun;Lee, Ilsuk;Park, Kee-eon;Hong, Haejin;Sung, Kang-keyng
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • The following study reviewed the walking patterns of stroke patients with hemiplegia, which is called hemiplegic gait of stroke patients. Focusing is given to the changes in the distance and temporal factors of walking, which is called spatiotemporal characteristics, throughout the walking cycle. First, we introduced the definitions of essential terms related to gait and its measure. Second, we reviewed the spatiotemporal characteristics of hemiplegic gait. A main issue was that hemiplegic gait showed significant deviations from normal healthy gait. Although hemiplegia is primarily associated with unilateral motor disorder, changes in almost all spatiotemporal parameters used to assess walking were evident on both the involved and uninvolved sides of the body. Last, we reviewed the changes of spatiotemporal parameters of hemiplegic gait according to the prognosis or status of stroke patients, which may help to give a specific intervention for rehabilitation of stroke.

  • PDF

A Study of Gait and Gait Analysis Techniques (보행과 보행분석법에 관한 연구)

  • Bae Sung-Soo;Lee Jin-Hee;Yoon Chang-Goo
    • The Journal of Korean Physical Therapy
    • /
    • v.8 no.1
    • /
    • pp.49-64
    • /
    • 1996
  • The technology of gait analysis is moving rapidly. Human gait is very complex, and a through understanding of it demands with the basic principles of biomechanics and the technology used to measure gait. Some professionals reluctance to use gait analysis may be due to the amount of time and effort necessary to accomplish this and the necessity for teamwork among the disciplines involved. Any form of observational gait analysis has limited precision and is more descriptive than quantative. The techniques of 3-D kinetic and kinematic analysis can provide a detailed biomechanical description of normal and pathological gait. This article review gait characteristics and procedures that are available for gait analysis. We are certain that, given the steady advance of technology and our continued efforts to document the benefits of that technology. gait analysis will soon be a routine part of the evaluation of both the elite athlete and the physically impaired adult or child.

  • PDF

Gait Characteristics of Sasang Constitution with 3-Axis Accelerometer-Based Gait Analysis (3축 가속도계를 이용한 사상체질별 보행특성 연구)

  • Lee, Dongkyu;Jeong, Seoyoon;Kim, Lakhyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.31 no.4
    • /
    • pp.225-233
    • /
    • 2020
  • Objectives: This study aimed to reveal the gait characteristics of each Sasang constitution by examining the differences in gait analysis indicators using a 3-axis accelerometer. Methods: Ninety-one participants were classified through the TS-QSCD (Two-Step Questionnaire for Sasang Constitution Diagnosis) method and gait analysis was performed using a 3-Axis Accelerometer (G-WALK. BTS Bioengineering, Italy). Gait analysis in returning to the 6-meter turnaround point and 6-minute walking test were performed. The differences in the gait analysis index values were analyzed between each constitution. Results: The gait analysis of 91 subjects (37 Taeumin, 37 Soyangin, and 17 Soeumin), showed that the percent stride length/height in the Soyangin subjects was significantly higher than that of the Taeeumin and Soeuminin subjects in the spatiotemporal walking variables (p<0.05). Stride length also showed the widest tendency in the Soyangin subjects (p=0.05). In the kinesiological analysis, the range of pelvic obliquity angles in the Soeumin subjects was significantly wider than that of the Taeumin and Soyangin subjects (p<0.05). In the six-minute walking test, the Soyangin subjects walked the farthest at 309.41±35.23 m (p=0.064). Conclusions: In a comparison of the gait characteristics for each Sasang constitution using a three-dimensional accelerometer, the stride width of the Soyangin subjects was the widest compared to the Taeeumin, and Soeumin subjects, and Soyangin's walking speed showed a faster tendency than that of the Taeeumin and Soeumin subjects.

Alteration of Gait Characteristics in Hemiplegic Elderly during Straight and Revolution Gaits (직선 및 회전 보행 시 편마비에 따른 고령자의 보행 특성 변화)

  • Jung, HoHyun;Lee, BumKee;Chun, Kyeong Jin;Lim, Dohyung
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.26-34
    • /
    • 2014
  • Little information is available about the characteristics in revolution gait of hemiplegic elderly, which is frequently represented in daily life. It is also hard to elucidate purely the characteristics due to hemiplegia because of no consideration of aging factors. The aim of study is to identify the alteration characteristics of lower extremity joint angles in both straight and revolution gaits together due to hemiplegia through comparing healthy with hemiplegic elderly. Following Institutional Review Board approval, twelve healthy and hemiplegic elderly were participated and the center of body mass (COM) and lower extremity joint angles were measured during straight and revolution gaits using a computer-aided video motion capture system. The results showed that the gait characteristics were generally altered in both straight and revolution gaits due to hemiplegia (p < 0.05). The gait characteristics were then different between the straight and revolution gaits each other. This study may be valuable by identifying for the first time the alterations of the lower extremity joint angles in both straight and revolution gaits due to pure hemiplegia through comparing healthy elderly with hemiplegic elderly.

Kinetic characteristics of initiation of gait (보행시작의 운동역학적 특성)

  • 김봉옥;조강희
    • Proceedings of the ESK Conference
    • /
    • 1995.10a
    • /
    • pp.141-155
    • /
    • 1995
  • To understand kinetic characteristics during the process of initation of gait from standing, from the visual cue to toe off of the stance limb, vertical ground reaction forces(GRF) and center of pressure(COP) during gait initation period were evaluate with two force platforms placed side by side in thirty two adults(young 16, elderly 16, each mean age 27.79 and 51.70 years) with no history of 7 neuromusculo-skeletal abnormality. Gaint initation period of swing and stance limbs, percentage of gait initiation period and ratio of the vertical forces to body weight at each peak of the vertical forces of both limbs, and also movement of net COP were measured and described. 2 groups, one of 16 young adults and another of 16 elderly adults, were compared statistically. These data showed the increase of initiation of gait period and the decrease of movement of net COP, nd also can now be used as a part of database when initation of gait in subjects with neuromusculoskeletal abnormalities need to be evaluated.

  • PDF

A Comparative Study of Gait Characteristics between Single Axis Foot and Energy Storing Foot for Sports in Trans-tibial Amputee (하퇴절단자용 단축식 발과 스포츠용 에너지 저장형 발 보행 특성 비교연구)

  • Chang, Yun-Hee;Bae, Tae-Soo;Kim, Shin-Ki;Mun, Mu-Seong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.2
    • /
    • pp.126-132
    • /
    • 2009
  • This study examined the differences in spatio-temporal parameters, joint angle, ground reaction force (GRF), and joint power according to the changes of gait speed for trans-tibial amputees to investigate the features of the energy-storing foot for sports. The subjects walked at normal speed and at fast speed, wearing a single-axis type foot (Korec) and an energy-storing foot for sports (Renegade) respectively. The results showed that Renegade yielded faster gait speed as well as more symmetric gait pattern, compared to Korec. However, as gait speed was increased, there was no significant difference in kinematics, ground reaction force, and joint power between two artificial foots. This was similar to the results from previous studies regarding the energy-storing foot, where the walking velocity and gait symmetry have been improved. Nevertheless, the result of this study differed from the previous ones which reported that joint angle, joint power, and GRF increased as the gait speed increased except spatio-temporal parameters.