• Title/Summary/Keyword: Gage R&R study

Search Result 50, Processing Time 0.024 seconds

A Study of Gage R&R Analysis Considering the Variations of Between-Within Group and Within Part (군간-군내-부품내 변동을 고려한 Gage R&R 분석에 관한 연구)

  • Lee, Seung-Hoon;Lee, Chang-Woo
    • IE interfaces
    • /
    • v.18 no.4
    • /
    • pp.444-453
    • /
    • 2005
  • The purpose of the Gage R&R study is to determine whether a measurement system is adequate for monitoring a process. If the measurement system variation is small relative to the process variation, then the measurement system is deemed "adequate". The sources of variation associated with the measurement system are compared using an analysis of variance (ANOVA) model, in general. A typical ANOVA model used in a standard Gage R&R study is the two-factor random effect model. Then, the ANOVA partitions the total variation into three categories: repeatability, reproducibility, part variation. However, if the process variation possesses the between group variation, within group variation, and within part variation, these variations can cause the measurement system evaluation to provide misleading results. That is, in the standard Gage R&R study these variations affect the estimate of repeatability, reproducibility, or both. This paper presents a four-factor nested factorial ANOVA model which explicitly considers these variations for the Gage R&R study. The variance component estimators are derived by setting the EMS equations equal to the corresponding mean square from the ANOVA table and solving. And the proposed model is compared with the standard Gage R&R model.

Some Relationships between Measurement Capability Indices of Type 1 Study, Gage R&R Study, and ISO 22514-7 (Type 1 Study, Gage R&R Study와 ISO 22514-7의 측정능력지수 간 연관성 분석)

  • Lee, Seung-Hoon;Lim, Keun
    • Journal of Korean Society for Quality Management
    • /
    • v.44 no.1
    • /
    • pp.77-94
    • /
    • 2016
  • Purpose: This paper reviews Type 1 Gage study, Gage R&R study, and procedure of ISO 22514-7 for assessing a measurement system, and discusses some relationships between the measurement capability indices. Methods: The gage capability index $C_g$ of Type 1 Gage study, precision-to-tolerance ratio PTR of Gage R&R study, and measurement performance ratio $Q_{MS}$ and $Q_{MP}$ of ISO 22514-7 are considered in this paper. Results: This paper derives the relationships between $C_g$ and $Q_{MS}$, PTR and $Q_{MP}$, and $Q_{MS}$ and $Q_{MP}$, respectively, and discusses the acceptance conditions for each procedures. Conclusion: The measurement capability analysis is the first step for the quality improvement of the manufacturing processes. Therefore the result of this study provides a helpful guidelines for assessing the measurement system, enabling proper evaluation of manufacturing processes.

A Study on the Effect of Gage R&R for 6 Sigma Quality (6시그마 품질을 위한 Gage R&R의 영향에 관한 연구)

  • 이승훈;이정환
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.55
    • /
    • pp.13-24
    • /
    • 2000
  • 6 sigma movement is the most prominent quality improvement methodology in practice. Measurement plays an important role in helping any organization improve quality. Therefore, the measurement systems analysis is the first step for the quality improvement of manufacturing process in 6 sigma movement. In this study, we investigate the effect of Gage Repeatability and Reproducibility(Gage R&R) in view of defect rate and process capability indices, and provide guidelines for acceptance of gage repeatability and reproducibility(%R&R) for six sigma quality.

  • PDF

A Study of Gage R&R Analysis Considering the Variations of Between-Within Group and Within Part (군간-군내-부품내 변동을 고려한 Gage R&R 분석에 관한 연구)

  • Lee, Seung-Hun;Lee, Chang-U
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2005.05a
    • /
    • pp.975-982
    • /
    • 2005
  • The purpose of the Gage R&R study is to determine whether a measurement system is adequate for monitoring a process. If the measurement system variation is small relative to the process variation, then the measurement system is deemed 'adequate'. The sources of variation associated with the measurement system are compared using an analysis of variance (ANOVA) model, in general. A typical ANOVA model used in a standard Gage R&R study is the two-factor random effect model. Then, the ANOVA partitions the total variation into three categories: repeatability, reproducibility, part variation. However, if the process variation possesses the between group variation, within group variation, and within-part variation, these variations can cause the measurement system evaluation to provide misleading results. That is, in the standard Gage R&R study these variations affect the estimate of repeatability, reproducibility, or both. This paper presents a four-factor nested factorial ANOVA model which explicitly considers these variations for the Gage R&R study. The variance component estimates are derived by setting the EMS equations equal to the corresponding mean square from the ANOVA table and solving. And the proposed model is compared with the standard Gage R&R model.

  • PDF

Economical Values of Gage R&R Parameters (경제적인 Gage R&R 계수)

  • Park, Sung-Hun;Kang, Chang-Wook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.3
    • /
    • pp.129-135
    • /
    • 2012
  • Companies strive for quality improvement and use process data obtained through measurement process to monitor and control the process. Measurement data contain variation due to error of operator and instrument. The total variation is sum of product variation and measurement variation. Gage R&R is for repeatability and reproducibility of measurement system. Gage R&R study is usually conducted to analyze the measurement process. In performing the gage R&R study, several parameters such as the appropriate number of operators (o), sample size of parts (p), and replicate (r) are used. In this paper we propose how to determine the optimal combination of number of operators (o), sample size of parts (p), and replicates (r) considering measurement time and cost by statistical method.

Gage R&R Study on Abdominal Sonography for Measuring Distance from Sangwan (CV13) to Pancreas - A Pilot Study - (복부초음파를 이용한 상완혈(上脘穴)-췌장 수직거리 측정시스템의 재현성 반복성 평가실험-A Pilot Study-)

  • Nam, Dong-Hyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.75-84
    • /
    • 2010
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from Sangwan (CV13) to pancreas. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from CV13 to pancreas with a ultrasound device three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from CV13 to pancreas was 6.29. So we concluded that repeatability and reproducibility of the ultrasound device system for measuring distance from CV13 to pancreas was acceptable.

Economic Evaluation of Measurement System by Principal Component Analysis (주성분 분석을 이용한 측정시스템의 경제적 평가)

  • Kang, Chung-Oh;Byun, Jai-Hyun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.24 no.2
    • /
    • pp.211-221
    • /
    • 1998
  • It is very important to have a satisfactory measurement system, since it is useless to try to improve the manufacturing process without an adequate measurement system. Therefore, evaluation of the measurement system is the first step for the quality improvement of the manufacturing process. To estimate the measurement error we must conduct a controlled gage repeatability and reproducibility(gage R&R) study. Many manufacturers use a gage or instrument to measure multiple dimensions for the overall quality of the manufactured parts. In this case, it is necessary to estimate the gage R&R for multiple dimensions. When a gage measures a large number of dimensions of a part, it is very time-consuming and costly to measure all the dimensions. In this paper we propose the use of the principal component analysis method to identify a few principal components out of the original multivariate measurement capability to explain most of the measurement system variation pattern.

  • PDF

Improvement of the repeatability and reproducibility of the meridian impedance measurement system MIR-2 (경락노선상 임피던스 측정기(MIR-2)의 측정신뢰도 개선방안 연구)

  • Yin, Chang-Shik;Lee, Hye-Jung;Kim, Jong-Yeol;Lee, Woo-Cheol
    • Korean Journal of Acupuncture
    • /
    • v.24 no.4
    • /
    • pp.55-67
    • /
    • 2007
  • Objectives : The repeatability and reproducibility of MIR-2, a newly developed impedance measurement device (four electrode method) on skin are of the meridian system, is evaluated and a method to improve the reliability is discussed. Methods : Multiple gage R&R studies were conducted for the impedance measurements over bilateral KI3 acupoint in ten participants by three assessors using MIR-2 device. Gage R&R studies were repeated after controlling the acupoint locating method or one value correction by replacing one assessor's outlying value with an average of the other assessors' values to explore any feasibility of improvement of measurement reliability. Results : Controlling acupoint locating method and replacing one value with an average of other assessors' value led to improved variation metrics in a gage R&R study. Conclusions : Measurement reliability can be improved by controlling measurement procedures or by using repeated measurement method, which will facilitate development of clinically applicable measurement device with reliability.

  • PDF

Review and Suggestions of Models for Measurement System Analysis (측정 시스템 분석 모형의 고찰 및 새로운 모형의 제안)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.1
    • /
    • pp.191-195
    • /
    • 2008
  • The present study contributes reviewing and suggesting various models for measurement system analysis (MSA). Measurement errors consist of accuracy, linearity, stability, part precision, repeatability and reproducibility (R&R). First, the major content presents split-plot design, and the combination method of crossed and nested design for obtaining gage R&R. Second, we propose $\bar{x}-s$ variable control chart for calculating the gage R&R and number of distinct category. Lastly, investigating the determination of gage performance curve which establishes the control specification propagating calibration uncertainties and measurement errors is described.

Study on analysis of initial Data on 6 Sigma application in real fields (6 Sigma 현장적용 적용 시 초기 데이터 분석에 대한 고찰)

  • Lee, Sang-Bok;Choe, Eun-Hyang
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2009.10a
    • /
    • pp.33-39
    • /
    • 2009
  • 본 연구에서는 현장에서 6 시그마를 활용 시 통계분석의 기초가 되는 초기 데이터 분석에 대한 고찰이다. 통계의 가장 기본이 되는 데이터가 잘못되었으면 나머지 모두 문제가 된다. 이에 데이터 초기에 발생할 수 있는 여러 오류의 가능성을 살펴보고 각각에 대해 해결책을 제시하였다. 여기서 활용하는 방법들은 계측기 선정, Gage R&R, Histogram, Box-plot, PDF, Box-Cox 변화 등이다.

  • PDF