Evaluation of Survival Rate and Crestal Bone Loss of the Osstem GS II Implant System

  • Kim, Young-Kyun;Park, Ji-Hoon;Shen, Winston Tan Kwong;Carreon, Charlotte Ann Z.
    • Journal of Korean Dental Science
    • /
    • 제2권2호
    • /
    • pp.31-34
    • /
    • 2009
  • The survival rate of the OSSTEM GS II Implant 1 year after serving the prosthetic function in 2 domestic and foreign medical institutes was 97.57%; the success rate was 95.7%, and the average alveolar bone resorption was 0.24mm(n=389). In particular, the alveolar bone resorption occurred differently according to the placement location as well as whether or not the patient underwent bone grafting operation, but the implant s length and diameter did not have significant impact on alveolar bone resorption.

  • PDF

골 이식술 후 Osstem Implant (US II Plus/GS II)의 다기관 임상연구 (A multicenter clinical study of installed US II Plus/GS II Osstem implants after bone graft)

  • 정광;오철중;하지원;국민석;박홍주;오희균;김수관;김영균;김우철
    • 대한치과의사협회지
    • /
    • 제50권12호
    • /
    • pp.743-754
    • /
    • 2012
  • urpose : The purpose of this study was to evaluate the US II plus/GS II Osstem$^{(R)}$ implants through the study for the clinical success rate during the installation of the Osstem¢Á implants after bone graft. Materials and Methods : This study was researched in the 4 medical institutions: Chonnam National University, Chosun University, Bundang Seoul National University Hospital, and FM dental clinic from May, 2002 to September, 2009. Based on the total number of 60 patients whose treatment was the installation of the US II plus/GS II Osstem¢Á implants after bone graft, we evaluated success rate of implants. We analysis the distribution of patient's age and gender, edentulous area, bone type, fixture length and diameter, installation and loading time, donor site, bone graft material and method, antagonistic teeth, and survival and success rate. From these analyses we got the following results. Results : 1. In this study, the total number of patients who have been installed with US II plus implant was 27, and total of 52 implants were installed. The average age was 38.9, with 16 male, and 11 female patients. 2. The total number of patients who have been installed with GS II implant was 33, and total of 54 implants were installed. The average age was 49.7, with 24 male, and 9 female patients. 3. As for bone graft method, either autogenous bone or a mix of autogenous and heterogenous bone was used(88.4%) for US II plus. Chin, iliac, and Maxillary tuberosity were the donor sites for autogenous bone graft, and onlay method of bone graft was performed. 4. Allogenic bone or a mix of autogenous and heterogenous bone was used(77.8%) for GS II. Chin, ramus, and tibia were the donor sites for autogenous bone graft, and GBR method of bone graft was performed. 5. The duration from the installation of implants to setting of final prosthesis was average of 16 months and 10 months for US II plus and GS II respectively. Also, the final follow up period was average of 31 months and 28 months respectively. During this period, one GS II implant was removed from 1 patient due to failure of early osteointegration. 6. The survival rates were 100% and 98.1%, and success rates were 94.2% and 94.4% for US II plus and GS II implant respectively. Conclusion : On the evaluation of our clinical study, both US II plus and GS II Osstem¢Á implants showed the excellent clinical results after bone graft.

임플란트의 형태가 초기 안정성에 미치는 영향 (Influence of Implant Designs on Initial Stability)

  • 조재명;김창섭;윤미정;정창모;서승우
    • 구강회복응용과학지
    • /
    • 제26권1호
    • /
    • pp.47-57
    • /
    • 2010
  • 임플란트-골 계면상에 미세동요 없이 회복기를 가지는 것은 골융합을 위해서 필수적이다. 이를 위해 임플란트의 초기 안정성은 성공적인 예후를 위해서 중요한 요건이다. 충분한 골질과 골량은 임플란트의 초기 안정성과 조기 실패 방지를 위해 중요한 요소이지만, 임플란트가 갖는 외형적 특성이 초기 안정성에 미치는 영향에 대한 연구는 부족하다. 이에 본 연구는 임플란트의 형태가 초기 안정성에 미치는 영향을 알아보고자 하였다. 골질에 따라 피질골과 해면골의 두께가 서로 다른 모형골에 straight body의 US II, GS II, SS II system과 tapered body의 GS III system (OSSTEM Implant Co., Seoul, Korea) 임플란트를 식립하고 식립 회전력과 공진 주파수 및 동요도를 측정하였다. 이번 실험에서 초기 안정성에 주요한 영향을 미치는 요소는 골질로 나타났다. 임플란트의 형태에 따라 이중 나사선을 가지는 GS II 임플란트가 초기 안정성은 높게 나타났으며 tapered 한 임플란트가 straight 임플란트에 비해서 높은 초기 안정성을 얻을 수 있음을 알 수 있었다. 또한 tapered 임플란트 식립 시 임플란트의 외형과 조화된 식립구를 형성하는 것이 피질골이 두꺼운 경우 피질골에 과도한 압축력을 감소시키고 반대의 경우 해면골로부터 좀 더 많은 골고정을 얻을 수 있음을 알 수 있었다.

A Multicenter Clinical Study on the Survival and Success Rates of Two Commercial Implants of Korea according to Loading Period

  • Yoon, Sung-Hwan;Kim, Myung-In;Chung, Kwang;Jung, Seunggon;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun;Kim, Su-Gwan;Kim, Young-Kyun;Cho, Yong-Seok;Kim, Woo-Cheoul;Yang, Choon-Mo
    • Journal of Korean Dental Science
    • /
    • 제6권2호
    • /
    • pp.67-77
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the survival and success rates of Korean Osstem implants US II Plus, GS II following loading period. Materials and Methods: Dental records were obtained in total 201 patients who were treated with Korean Osstem implants US II Plus, GS II on both maxillary and mandibular anterior and posterior areas in six different clinics for 2 years from January 2007 to December 2008. Total 430 implants were evaluated clinically and radiographically using predefined success criteria prospectively and following results were obtained. Result: US II Plus, GS II implants showed high survival rates of more than 99% and high success rates more than 90% independent of loading period. As a result of cross analysis to evaluate clinical significance between implant loading period and success rate, the P-value of US II Plus was 0.10 (P>0.05), and the P-value of GS II was 0.17 (P>0.05), which showed no statistical significance. Bone quality, smoking, and edentulous state are factors that can affect the survival and success rates following differently loaded implants, but did not significantly affect in this study. Conclusion: These results suggest that selection of loading period of Korean Osstem implants US II Plus, GS II would be done carefully considering implant install area, the quality alveolar bone, the state of edentulous ridge and experience of operator, though they showed clinically good results on both maxillary and mandibular anterior and posterior areas.

임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이나사풀림에 미치는 영향 (Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening)

  • 박재경;정창모;전영찬;윤지훈
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.137-147
    • /
    • 2008
  • 임플랜트 보철물에서 각 구성 요소를 연결하는 나사 풀림 현상이 흔히 발생하고 있다. 나사 풀림을 최소화하기 위해서 연결 구성 부품 사이의 압축력을 최대로 하는 것이 중요한데, 나사 신장의 허용 한계 내에서 조임회전력을 증가시켜 나사 내부의 인장력 즉 전하중을 극대화하기 위해서는 마찰 계수를 감소시켜 초기 조임회전력의 손실을 최소화해야 한다. 건조 윤활제를 나사 표면에 코팅한 나사들이 전하중을 증가시키고 나사 풀림을 감소시키나 나사의 반복체결에 따른 코팅표면의 마모가 문제점으로 지적되고 있다. 최근 내마모성이 우수하며 동시에 나사의 마찰 저항을 최소화할 수 있는 텅스텐 카바이드/탄소 코팅을 이용한 나사가 임상에 사용되고 있으나 실제적으로 연결부 안정성에 미치는 영향에 관한 연구는 미미한 편이다. 이에 본 연구에서는 external butt joint 형태를 가지는 US II 시스템과 one stage용 8도의 internal cone 연결형태의 SS II 시스템 및 11도의 internal cone 연결형태의 GS II 시스템에서 티타늄 합금 나사의 텅스텐 카바이드/탄소 코팅이 지대주 나사 풀림에 미치는 영향을 알아보기 위하여 100만 회 반복 하중 전후의 풀림회전력 및 상실률을 비교한 결과 다음과 같은 결론을 얻었다. 1. 초기 풀림회전력은 티타늄 합금나사보다 텅스텐 카바이드/탄소 코팅 나사를 사용한 경우 작게 나타났으며 (P<.01), 동일 나사를 사용한 경우에는 임플랜트 시스템 간에 차이가 없었다 (P>.05). 2. 반복하중에 따른 풀림회전력의 상실률은 두 나사 모두에서 external butt joint 형태의 US II 시스템이 internal cone 연결형태의 SS II 와 GS II 시스템 보다 크게 나타났으나, SS II 와 GS II 시스템 사이에는 차이를 보이지 않았다 (P<.01). 3. 텅스텐 카바이드/탄소 코팅 나사를 사용한 경우 티타늄 합금 나사에 비해 모든 시스템에서 반복하중 후 풀림회전력 상실률이 작게 나타났으며 (P<.01), 코팅 나사 사용으로 인한 상실률의 감소차는 임플랜트 시스템 간에 차이를 보이지 않았다 (P>.05).

이중미세나사산 임플란트의 임상적 및 방사선학적 1년 평가 (Clinical and radiographic evaluation of implants with dual-microthread: 1-year study)

  • 권미아;김용덕;정창모;이주연
    • Journal of Periodontal and Implant Science
    • /
    • 제39권1호
    • /
    • pp.27-36
    • /
    • 2009
  • Purpose: The stability of periodontal condition and marginal bone level were important to achieve long-term success of dental implant treatment. The aim of this study was to evaluate periodontal conditions and marginal bone loss around 67 GSII(OSSTEM, Seoul, Korea) dental implants with dual-microthread at the neck portion, 1 year after prosthetic loading. Materials and methods: Sixty-seven GS II dental implants in 27 patients(mean age; $47.4{\pm}14.0$ years) who received implant treatments at Pusan National University Hospital, were included in this study. Thirteen US II(OSSTEM, Seoul, Korea) implants with smooth neck design were selected for the control group. Periodontal and radiographic evaluations were carried out at baseline, 6 months and 12 months after prosthetic loading. Results: In the GS II group, plaque index(PI), gingival index(GI) and probing depth(PD) increased as time passed. In the US II group, GI and PD increased. Although marginal bone level was lower in the US II group in all evaluation periods, the changes between the periods were not statistically significant(p>0.05). In each period, periodontal parameters were not statistically significant between groups. Conclusion: One year after prosthetic loading, GS II and US II dental implants showed similar periodontal conditions and marginal bone response, and were within the criteria of success.

조임회전력이 임플랜트-지대주 나사 연결부의 안정성에 미치는 영향 (Influence of Tightening Torque on Implant-Abutment Screw Joint Stability)

  • 신현모;정창모;전영찬;윤미정;윤지훈
    • 대한치과보철학회지
    • /
    • 제46권4호
    • /
    • pp.396-408
    • /
    • 2008
  • 연구목적: 임플랜트 치료에서 가장 흔히 발생하는 기계적 문제점 중 하나는 나사의 풀림이다. 지대주 나사에 조임회전력을 가하는 목적은 나사를 신장시켜, 신장된 나사의 인장력에 의한 지대주와 고정체간의 압축력을 통해 연결부의 안정성을 부여하는 데 있다. 조임 회전력의 결과로 나타나는 전하중의 크기는 다양한 요소에 의해 영향을 받기 때문에, 동일한 조임회전력을 적용하였다 할지라도 임플랜트 시스템의 종류에 따라 전하중의 크기가 달라질 수 있다. 따라서 지대주 나사 연결부의 안정성을 위한 다양한 임플랜트 시스템의 적정 조임회전력 크기에 관한 연구가 필요하다. 본 연구에서는 external butt joint와 두 가지 internal cone 연결형태를 갖는 임플랜트 시스템들에서 지대주 나사의 조임회전력이 임플랜트-지대주 나사 연결부의 안정성에 미치는 영향을 하중 전후의 풀림회전력 측정을 통해 알아보고자 하였다. 연구재료 및 방법: External butt joint 형태를 가지는 US II 시스템과 $8^{\circ}$ internal cone 연결형태의 SS II 및 $11^{\circ}$ internal cone 연결형태의 GS II 시스템에서 20 Ncm, 30 Ncm, 그리고 40 Ncm의 각기 다른 조임회전력을 적용한 후 초기 풀림회전력 및 상실률과 $10^5$회의 반복하중 후의 풀림회전력 및 상실률을 비교 분석하였다. 연구결과 및 결론: 1. 초기 풀림회전력과 하중 후 풀림회전력은 조임회전력의 크기가 증가할수록 크게 나타났다 (P < .05). 2. 초기 풀림회전력 상실률은 SS II 시스템에서는 조임회전력 크기에 따른 차이가 없었으나 (P > .05), GS II와 US II에서는 20 Ncm 보다 40Ncm의 조임회전력에서 더 낮게 나타났다 (P < .05). 3. 하중 후 풀림회전력 상실률은 세 시스템 모두 30 Ncm의 조임회전력을 가했을 때 가장 낮게 나타났다 (P < .05). 4. 하중 후 풀림회전력 상실률은 SS II, GS II, 그리고 US II 순으로 높아지는 경향을 보였다. 5. 초기 풀림회전력과 하중 후 풀림회전력 상실률 간에는 상관관계가 없었다 (P > .05). 이상의 결과로부터 임플랜트 시스템의 종류뿐만 아니라 조임회전력의 크기 또한 지대주 나사의 풀림회전력 상실에 영향을 준다는 것을 알 수 있다. 따라서 임플랜트-지대주 나사 연결부 안정성 유지를 위해서는 임플랜트 시스템마다 적정 조임회전력이 제시되어야 하고, 또한 임상에서 이를 준수하는 것이 매우 중요하다고 생각된다.

지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구 (Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments)

  • 이미순;서규원;류재준
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.164-173
    • /
    • 2009
  • 연구 목적: 심미적 장점을 지닌 지르코니아 지대주와 금속 지대주 사이에 반복 하중 전, 후의 풀림 회전력을 비교하여 지대주 재질에 따른 나사 안정성에 차이가 있는지를 비교 분석해 보고자 하는 것이다. 연구 재료 및 방법: 실험군은 크게 외측 연결 구조(US II, Osstem Implant, Korea)와 내측 연결 구조(GS II, Osstem Implant, Korea)의 임플란트 시스템을 두 군으로 나누었다. 각각의 군에서 지르코니아 지대주군와 금속 지대주군으로 나누어 실험하였다. 각군당5개씩의 시편을 제작하였다. 임플란트 고정체를 별도 제작된 지그에 고정시킨다. 디지털 토크게이지를 이용하여 30 Ncm의 조임 회전력을 가하고 10분 후 동일 조임 회전력을 한번 더 적용하였다. 다음 각 지대주 나사의 초기 풀림 회전력을 디지털 토크게이지로 측정하였다. 동일 시편을 다시 30 Ncm의 조임 회전력을 가하여 체결한 후, 유압식 동적 재료시험기(Instron, USA)에 임플란트 매식체를 치과용 임플란트 피로시험에 관한 ISO/FPIS 14801:2003(E)규정을 참고하여 고정시켰다. 최소 하중은 10 N, 최대 하중은 250 N의 sine형 반복 하중을 $30^{\circ}$의 경사각도로, 하중 주기는 14 Hz로, 100만 회의 반복 하중을 적용한 후 풀림 회전력을 측정하였다. 결과: 1. 모든 시스템에서 지대주 나사의 풀림 회전력이 조임 회전력 보다 감소하였으나, 나사 풀림 현상은 나타나지 않았다. 2. 반복 하중 전과 후의 나사 풀림 회전력은 두 임플란트 시스템 모두에서 지르코니아 지대주가 금속 지대주보다 더 컸다(P<.05). 3. 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 모두에서 지르코니아 지대주와 금속 지대주가 차이가 없는 것으로 나타났다(P>.05). 4. 금속 지대주에서 반복 하중에 따른 풀림 회전력 상실률은 내측 연결 형태의 GS II 시스템이 외측 연결형태의 US II 시스템보다 작았다(P<.05). 5. 지르코니아 지대주에서는 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 간에 차이가 없는 것으로 나타났다(P>.05). 결론: 본 실험을 통해 100만회 반복 하중 하에서 지르코니아 지대주가 금속 지대주에 비해 나사 결합부 안정성이 더 크다는 결론을 내릴 수 있다.

기능적 부하 후 임플란트 주변의 골 흡수에 대한 방사선학적 연구 (STUDY ON RADIOGRAPHIC EVALUATION OF MARGINAL BONE LOSS AROUND OSSEOINTEGRATED IMPLANT AFTER FUNCTIONAL LOADING)

  • 최수진;지영덕;고세욱
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권4호
    • /
    • pp.240-247
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate marginal bone loss to the bone crest functionally loaded for up to eighteen months and also with regard to other variables of interest. Material and Methods: 135 endosseous implants(GS II, Osstem, South Korea) were placed in 35 patients. The design of GS II implant is straight with the microthread. Radiographic examinations were conducted at baseline (implant loading) and 3, 6, 9, 12 and 18 months after loading. Marginal bone level measurement was made from the reference point to the lowest observed point of contact of the marginal bone with the fixture. The reference point of the fixture was the border between the blasted surface and machined surface of the fixture. Results: Implants were on function for a mean 12.7 months(range, 3?18 months). For the 56 maxillary and 79 mandibular implants, mean marginal bone loss was 0.68 mm and 0.70 mm. Implants placed maxillary posterior area displayed more crestal bone loss than the other position. The difference between mesial and distal bone levels was statistically significant (p<0.05) with respective means of 0.51 mm and 0.62 mm. Also, The difference between bone graft group and no-bone graft group was statistically significant(p<0.05) with respective means of 0.38 mm and 0.66 mm. But no statistically significant influence of sex, type of surgery(one or two stage surgery), the implant length was observed(p>0.05). Conclusion: This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

국산 내부연결형 임플란트시스템(GS II$^{(R)}$)에서 지대주 연결방식에 따른 응력분석에 관한 연구 (Three-Dimensional Finite Element Analysis of Internal Connection Implant System (Gsii$^{(R)}$) According to Three Different Abutments and Prosthetic Design)

  • 장미라;곽주희;김명래;박은진;박지만;김선종
    • 구강회복응용과학지
    • /
    • 제26권2호
    • /
    • pp.179-195
    • /
    • 2010
  • 임플란트 보철물에 저작력 등 외부 하중이 작용하면 내부 반응으로 응력이 발생되는데 지지골에 나타난 응력은 골재생 및 흡수 파괴, 임플란트에 나타난 응력은 임플란트 자체의 파절이나 나사의 풀림현상 및 파절, 상부 구조물에 나타난 응력은 보철물의 파절 등을 예견하는 지침이 될 수 있을 것이다. 지대주의 형상과 재질에 따라 연결방법과 보철방법이 달라지고 임플란트 내부의 하중전달 기전이 변하게 되고 이에 따라 악골에 발생하는 응력분포 역시 달라질 수 있다. 본 연구에서는 하악 제 1대구치 부위에 이중나사 구조를 갖고 원추형 내측연결 임플란트 시스템인 GSII$^{(R)}$ (Osstem, Korea)임플란트를 이용해 지대주의 종류를 티타늄 소재의 2-piece Transfer$^{TM}$ abutment (GST), 금합금 소재의 2-piece GoldCast$^{TM}$ abutment(GSG), 외부 연결형태를 가진 3-piece Convertible$^{TM}$ abutment (GSC) 로 분류하여 이에 따른 응력분포 양상을 비교 분석하여 보았다. 결과 하중조건에 관계없이 응력은 주로 지대주와 고정체가 접촉하는 경부에 집중되었다. 또한 하중조건에 관계없이 임플란트의 고정체 상부와 접촉하는 치밀골에 높은 응력이 나타나고 해면골에는 아주 작은 응력이 나타났다. 축하중보다는 중심축을 벗어난 하중조건에서 더 높은 응력이 발생되었고 수직하중보다 경사하중에서 더 높은 응력이 발생되었다. 전체에 걸친 최대응력은 GSG에서는 지대주, 치관 및 고정체에 고르게 분포되었고 GST는 주로 고정체와 지대주 나사에, GSC는 고정체와 지대주에 집중되었다. 세 지대주 간 골내의 최대응력에는 유의한 차이가 없었고 GSG가 전체 구성부의 응력분포에 있어 유리한 것으로 나타났다.