• Title/Summary/Keyword: GOOD BALANCE system

Search Result 196, Processing Time 0.035 seconds

Large Signal Unified Model for GaAs pHEMT using Modified Curtice Model (새롭게 수정된 Curtice 모델을 이용한 GaAs pHEMT 대신호 통합모델 구축)

  • 박덕종;염경환;장동필;이재현
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.4
    • /
    • pp.551-561
    • /
    • 2001
  • In this paper, the large signal unified model is established for H4O GaAs pHEMT of GEC-Marconi using modified Curtice model. This unified model includes DC characteristic, small signal, and noise characteristic as various bias. Particularly, the model can simply and physically explain trans-conductance $(g_m)$ of pHEMT using modified Curtice model, and can tell the difference $g_m$, $R_ds$ at DC and these at AC through inclusion of internal RF-choke. The results of the established model built up using SDD in HP-Eessof show good agreement to the S/W measured data in DC, small signal, and noise characteristic. This model can also be applied to various computer aided analysis, such as linear simulation, 1-tone harmonic balance simulation, and multi-tone harmonic balance simulation, so the LNA(Low Noise Amplifier), oscillator, and mixer design has been shown using this model library.

  • PDF

Empirical Analysis on the Cooling Load and Evaporation Efficiency of Fogging System in Greenhouses (온실의 냉방부하 및 포그시스템의 증발효율 실험분석)

  • Nam, Sang-Woon;Seo, Dong-Uk;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.147-152
    • /
    • 2015
  • In order to develop the cooling load estimation method in the greenhouse, the cooling load calculation formula based on the heat balance method was constructed and verified by the actual cooling load measured in the fog cooling greenhouse. To examine the ventilation heat transfer in the cooling load calculation formula, we measured ventilation rates in the experimental greenhouse which a cooling system was not operated. The ventilation heat transfer by a heat balance method showed a relatively good agreement. Evaporation efficiencies of the two-fluid fogging system were a range of 0.3 to 0.94, average 0.67, and it showed that they increased as the ventilation rate increased. We measured thermal environments in a fog cooling greenhouse, and calculated cooling load by heat balance equation. Also we calculated evaporative cooling energy by measuring the sprayed amount in the fogging system. And by comparing those two results, we could verify that the calculated and the measured cooling load showed a relatively similar trend. When the cooling load was low, the measured value was slightly larger than calculated, when the cooling load was high, it has been found to be smaller than calculated. In designing the greenhouse cooling system, the capacity of cooling equipment is determined by the maximum cooling load. We have to consider the safety factor when installed capacity is estimated, so a cooling load calculation method presented in this study could be applied to the greenhouse environmental design.

Modeling System for Unsteady Flow Simulations in Drainage Channel Networks of Paddy Field Districts (논 지구의 배수로 부정류 흐름 모의를 위한 모델링 시스템)

  • Kang, Min Goo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.2
    • /
    • pp.1-9
    • /
    • 2014
  • A modeling system is constructed by integrating an one-dimensional unsteady flow simulation model and a hydrologic model to simulate flood flows in drainage channel networks of paddy field districts. The modeling system's applicability is validated by simulating flood discharges from a paddy field district, which consists of nine paddy fields and one drainage channel. The simulation results are in good agreement with the observed. Particularly, in the verification stage, the relative errors of peak flows and peak depths between the observed and simulated hydrographs range 8.96 to 10.26 % and -10.26 to 2.97 %, respectively. The modeling system's capability is compared with that of a water balance equation-based model; it is revealed that the modeling system's accuracy is superior to the other model. In addition, the simulations of flood discharges from large-sized paddy fields through drainage channels show that the flood discharge patterns are affected by drainage outlet management for paddy fields and physical characteristics of the drainage channels. Finally, it is concluded that to efficiently design drainage channel networks, it is necessary to analyze the results from simulating flood discharges of the drainage channel networks according to their physical characteristics and connectivities.

Analysis of Heat Transfer of Thermal Storage Roof with the Air Circulation System (공기순환구조를 갖는 축열지붕의 열전달해석)

  • Shin, U.C.;Park, S.H.;Baek, N.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.33-42
    • /
    • 2001
  • The paper discusses the modelling of the thermal storage roof with the air circulation system. In this system, the fully glazed absorber plate is put on the top of the conventional pitch roof made of massive concrete and acts as a solar air heater. Solar radiation collected into absorber is stored in the roof structure by radiation and convection so that it reduces the nighttime heating load through the roof. Another part of the energy is also transmitted to internal air drawn into the channel and is then introduced Into the room. To analysis the system, the energy balance equations are developed and are solved using a finite difference method. The calculation results show a good agreement with the measured ones obtained from our experiments. From the results, it is seen that the thermal storage roof with the air circulation system reduces significantly the conductive heat loss compared with that for the conventional roof and has the instantaneous solar collection efficiency of about 30%.

  • PDF

A Study on the Safety Stock (안전재고에 관한 연구)

  • 박병기;정종식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.10 no.16
    • /
    • pp.143-147
    • /
    • 1987
  • Safety stocks constitute one of the major means of dealing with the uncertainties associated with variation in demand and lead time. Adeguate safety facilitate production activities and help to assure customers if good service on the other hand, carrying safety storks ties up working capital on goods that sit idle. The major problem of safety stocks management thus of consists of trying to achieve an optimal balance between the other carrying cost and the costs of stock shortage. Therefore, this study aims to find safety stock level of the fixed reorder quantity system and the fixed reorder cycle system of minimizing total cost when both demand and lead time are variable. (The distribution of demand and lead time is a mere assumption that follows the normal distribution) The results can be summarized as follows. i) Safety factor on the safety stock is determined by carrying cost and the costs of stock shortage: An optimal safety stick=the costs of stork shortage($C_s$) (the carrying cost($C_h$)+the costs of stock storage($C_s$). ii) The safety stock level of the fixed reorder quantity system is ($a{\;}_p\sqrt{L}{\sigma}$) under uncertainties. iii) The safety stock level of the fixed reorder cycle system is ($a{\;}_p\sqrt{R+L{\sigma}}$) under uncertain demand and constant lead time. ($a{\;}_p\sqrt{L{\sigma}_d{\;^2+{\mu}^2L{\sigma}^2}$) under demand and lead time uncertainties.

  • PDF

A study on the steam boiler with high compression waste heat recovery system (고압축 폐열회수장치를 구비한 증기보일러에 관한 연구)

  • HAN, Kyu-il;CHO, Dong-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.3
    • /
    • pp.302-307
    • /
    • 2017
  • An electric steam boiler equipped with a condensate recovery system, which stores the condensate generated after using steam in steam washers, steam cookers, steam irons, and steam cleaners in a condensate tank and supplies compressed air to the condensate tank so that the condensate is recovered to the boiler by the pressure of the compressed air, was studied. In the results of this study, the heat energy balance between the quantity of the heat generated by the non-metallic surface heating element and the quantity of the heat absorbed by the water was good in a range of ${\pm}5%$. In addition, the heat transfer rate increased in proportion to the electric power of the surface heating element heater, the waste heat energy was normally recovered by the recovery of the condensate of the steam boiler equipped with the high compression waste heat recovery system, and the recovery rate of the waste heat exhibited 23%.

Design of a Rotary Electromagnetic Actuator with Linear Torque Output for Fast Steering Mirror

  • Long, Yongjun;Mo, Jinqiu;Chen, Xinshu;Liang, Qinghua;Shang, Yaguang;Wang, Shigang
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.69-78
    • /
    • 2015
  • This paper focuses on the design of a flux-biased rotary electromagnetic actuator with compact structure for fast steering mirror (FSM). The actuator has high force density and its torque output shows linear dependence on both excitation current and rotation angle. Benefiting from a new electromagnetic topology, no additional axial force is generated and an armature with small moment of inertia is achieved. To improve modeling accuracy, the actuator is modeled with flux leakage taken into account. In order to achieve an FSM with good performance, a design methodology is presented. The methodology aims to achieve a balance between torque output, torque density and required coil magnetomotive force. By using the design methodology, the actuator which will be used to drive our FSM is achieved. The finite element simulation results validate the design results, along with the concept design, magnetic analysis and torque output model.

Effect of light touch on body sway during a stable posture with blocked visual information

  • Kim, Jong-Gun;Kim, Jin-Hong;Do, Kwang-Sun;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.138-142
    • /
    • 2016
  • Objective: The purpose of this study was to investigate how light touch with a finger affects balance ability when a posture is maintained in the condition of visual information blockage and to provide a fundamental material for developing balance ability in the process of rehabilitation treatment. Design: Cross-sectional study. Methods: The study subjects were 17 healthy men and women in their twenties and thirties who were studying at S University in Seoul. The system was comprised of an equilateral triangular force platform. Subjects were asked to step on the foot position of the force platform (Good Balance, Finland) barefooted for 30 seconds, with eyes closed, hands hanging down loosely, and feet comfortably apart. It was connected to a laptop by using Bluetooth technology. An experiment was conducted in the following three circumstances: 1) no-touch trial, 2) light touch to the back (T7 area), and 3) light touch to the middle finger of the left hand. Each subject was given a 10-minute break between consecutive measurements. The experimental circumstances were performed randomly. Anteroposterior sway (APSV), mediolateral sway velocity (MLSV), and velocity moment (VM) were measured. Results: The APSVs (mm/s) were $9.32{\pm}3.37$ and $5.45{\pm}2.98$; the MLSVs (mm/s), $6.39{\pm}3.35$ and $3.31{\pm}2.48$; and VM ($mm^2/s$), $17.13{\pm}11.75$ and $6.76{\pm}8.31$ in the first and second experimental circumstances, respectively. APSV, MLSV, and VM values were significantly improved with the 1) no-touch trial and 2) light touch to the back trail conditions compared with the 3) light touch to the middle finger of the left hand condition (p<0.05). Conclusions: This study revealed that the balance ability for maintaining a body posture was influenced more by light touch to the back (T7) than by light touch with the sensitive fingertip and body sway diminished after visual information was blocked.

A Study on Performance of Thermoelectric Air-Cooling System in Parallel Flow (평행유동에서 공랭식 열전모듈 냉각시스템의 성능에 관한 연구)

  • Karng, Sarng-Woo;Shin, Jae-Hoon;Han, Hun-Sik;Kim, Seo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.421-429
    • /
    • 2011
  • Experimental and theoretical studies on cooling performance of two-channel thermoelectric air-cooling system in parallel flow are conducted. The effects of operating temperature to physical properties of thermoelectric module (TEM) are experimentally examined and used in the analysis of an air-cooling system considering thermal network and energy balance. The theoretical predicted temperature variation and cooling capacity are in good agreement with measured data, thereby validating analytic model. The heat absorbed rate increases with increasing the voltage input and decreasing thermal resistance of the system. The power consumption of TEM is linearly proportional to mean temperature differences due to variations of the physical properties on operation temperature of TEM. Furthermore thermal resistance of hot side has greater effects on cooling performance than that of cold side.

Flood Effects Analysis of Reservoir Basin through the Linkage of HEC-HMS and HEC-RAS Models (HEC-HMS와 HEC-RAS모형의 연계에 의한 댐 유역의 홍수영향 분석)

  • Lee, Weon-Hee;Kim , Sun-Joo;Kim , Phil-Shik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.2
    • /
    • pp.15-25
    • /
    • 2004
  • For the effective operation of irrigation reservoirs, a general and systematic policy is suggested to make balance of the conflicting purposes between water conservation and flood control. In this study, the flood effective analysis system was developed through the integration of long-term water budget analysis model, GIS-based HEC-HMS model and HEC-RAS model. The system structure consists of long-term water budget model using modified TANK theory, flood runoff and flood effects analysis model using HEC-GeoHMS, HEC-HMS and HEC-RAS models. The flood effects analysis system simulated the flood runoff from the upstream, downstream flood and long-term runoff of the watershed using the observed data collected from 1998 to 2002 of Seongju dam. The simulated results were reasonably good compared with the observed data. The optimal management method of the reservoir during the whole season is suggested in this study, and the flood analysis system can be a useful tool to evaluate a reservoir operation quantitatively for the mitigation of flood damages of reservoir basin.