• Title/Summary/Keyword: GLOBE TEMPERATURE

Search Result 119, Processing Time 0.021 seconds

Comparison of Thermal Environment and Biotope Area Rate according to Land Cover Types of Outside Space of School located in Chung-ju (충주시 학교외부공간 피복유형에 따른 온열환경 및 생태면적률 비교)

  • Ju, Jin-Hee;Ban, Jong-Heu;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.19 no.9
    • /
    • pp.1103-1108
    • /
    • 2010
  • This study was conducted to be used as basic data of environmental friendly construction planning by comparing and analyzing thermal environment, find particles and biotope area rate according to land cover types of outside space of schools located in Chung-ju. When meteorological factors were analyzed according to land cover types, for temperature planting area and paved area showed low-and high-temperature ranges, respectively, and relative humidity was negatively related with temperature as low-and high-temperature ranges corresponded to high-and low-humidity ranges, respectively. For Wet Bulb Globe Temperature Index (WBGT) by land cover types, it was observed to be artificial grass> bare land> natural grass. Find particles were different according to land cover types of playground with being bare land> artificial grass> natural grass in the order. Bare land playground, where there were artificial factors and no absorption of fine particles through stomata of leaves as a function of natural circulation, recorded the highest level of $39.8\;{\mu}g/m^3$ and the level was relatively higher compared to the levels by season in Chung-ju. Biotope area rate showed the order of M elementary school> K elementary school> C commercial high school. That was considered to be caused by the difference of land cover type of school playground accounting for a large part of a school.

Analyses on Comparison of UTCI, PMV, WBGT between Playground and Green Space in School (학교 운동장과 녹지공간의 UTCI, PMV, WBGT 비교 분석)

  • Yoon, Young-Han;Park, Seung-Hwan;Kim, Won-Tae;Kim, Jeong-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.1
    • /
    • pp.80-89
    • /
    • 2014
  • This study of the school's outdoor space for relaxing and activity of the two most numerous students, high heat and low heat with a green space, playground targets of thermal comfort indicators UTCI, PMV, WBGT using the thermal comfort students feeling compare the analyzed. The destination of this study, school facilities of Nam-gu, Namdong- gu, Incheon were studied and the investigation period was conducted from July to August. List of measurement, in the case of thermal comfort indicators, UTCI, PMV, WBGT was measured in the case of green, ratio of green coverage and GVZ was measured. GVZ analysis were as follows: A school ($4.71m^3/m^2$) B school ($3.34m^3/m^2$) C school ($0.38m^3/m^2$). Comparative analysis of the results of thermal comfort indicators by schools, UTCI was Green space $26.15{\sim}31.38^{\circ}C$ and playground $40.66{\sim}42.94^{\circ}C$, PMV values were 1.76 to 2.66 as a green space. WBGT was Green space $26.15{\sim}31.38^{\circ}C$, playground $31.67{\sim}34.53^{\circ}C$. Comparative analysis of the results of thermal comfort indicators UTCI, PMV, WBGT all A school, B school, C school, on the green space was comfortable levels more than playground. The results of the school type thermal comfort and green correlation analysis of thermal comfort UTCI, PMV, WBGT all solar radiation, globe temperature, and a positive correlation shown solar radiation, globe temperature is not comfortable, the higher was considered. UTCI, PMV, WBGT of thermal comfort indicator all ratio of green coverage, GVZ and negative correlation appears ratio of green coverage, GVZ was increased due to the lowering of the value of thermal comfort indicators was considered to be comfortable.

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.

Wear Comfort of Firefighters Protective Gloves in Dry and Wet Conditions at 70℃ Air Temperature with Radiant Heat (기온 70℃의 복사열 노출 환경에서 건조와 젖은 상태의 소방용 보호장갑 착용 시 쾌적성 평가)

  • Kim, Dami;Kim, Dohyung;Lee, Joo-Young
    • Journal of Korean Living Environment System
    • /
    • v.24 no.1
    • /
    • pp.95-106
    • /
    • 2017
  • The purpose of this study was to evaluate comfort functions while wearing firefighters' protective gloves in dry and wet conditions at $70^{\circ}C$ air temperature with radiant heat. Four types of firefighting gloves from Korea, Germany, United States, and Japan were evaluated in both dry and wet conditions by eight male firefighters. Firefighters put their hands and forearms wearing gloves into a hands-radiant chamber that maintained at an air temperature of $70{\pm}2^{\circ}C$ ($T_a$) and globe temperature $106^{\circ}C$ ($T_g$). During the exposure, subjects followed a fixed protocol of manual movements and stopped the exposure when they felt being intolerable. Results showed that completion time was extended by 6 min on average when gloves got wet and 15 min for the Japanese gloves was extended when compared to its dry condition (p<.001); microclimate humidity on the palm at the last stage was greater for wet conditions than dry conditions in the all gloves; and skin temperatures on mid-fingertip, palm, and hand were significantly lower for wet conditions than dry conditions especially for Japanese gloves (p<.001). These results indicate that the exposure time without thermal pain to radiant heat could be extended by wetting gloves during the low radiant heat exposure.

Comparison of Thermal Environment between Inland and Coastal Cities in Gyeongbuk during the Heat Wave of 2018 - Comparison between Daegu and Pohang - (2018년 폭염 기간 동안 경북의 내륙과 해안 도시 간 열 환경 비교 - 대구와 포항의 비교 -)

  • Choo, Sung-Hyun;An, Eun-Ji;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.30 no.8
    • /
    • pp.621-628
    • /
    • 2021
  • The characteristics of time changes in air temperature, DI (discomfort index) and WBGT (wet-bulb globe temperature) were investigated for inland city (daegu) and coastal city (pohang) of Gyeongbuk Province during the 2018 consecutive heat wave season. The time when the temperature dropped below 33℃ was around 19h in both regions. As such, the two regions were similar with respect to the time up to which the heatwave warning levels continued. However, the discomfort index (DI) was higher than 27 in Pohang. Most people feel unpleasant when an discomfort index of 27 or higher appears. The results indicated that Korea's night-time thermal environment during the summers is particularly poor in the southern coastal areas. WBGT began at 09:00 and lasted until 21:00, with a score of 31 or higher; this score, in principle, corresponded with the duration of outdoor activity in both regions. Therefore, it was found that outdoor work was at a level where all day long had to be stopped in both areas during the heat wave. Although time changes in temperature and WBGT were similar in both regions, Discomfort Index (DI) differed significantly. The difference refers to the fact that Pohang is strongly affected by the high heat capacity effect and the supply of water vapor from the sea.

Hydrometeors and Atmospheric Thermal Structure Derived from the Infrared and Microwave Satellite Observations: Infrared Interferometer Spectrometer (IRIS) and Microwave Sounding Unit (MSU) (적외선과 마이크로파 위성관측에서 유도된 대기물현상 및 대기 열적 상태: 적외선 간섭분광계 (IRIS)와 Microwave Sounding Unit)

  • Yoo, Jung-Moon;Song, Hee-Young;Lee, Hyun-A;Koo, Gyo-Sook
    • Atmosphere
    • /
    • v.12 no.4
    • /
    • pp.69-90
    • /
    • 2002
  • The infrared and microwave satellite observations have been used to derive the information of hydrometeors (i.e., cloud and precipitation) and atmospheric temperature. The observations were made by the Nimbus-4 Infrared Interferometer Spectrometer (IRIS) in 1970, and by the Microwave Sounding Unit (MSU) during the period 1980-99, which had channel 1~4 (Chl~4). The IRIS, which has a field of view of ~100 km, has been utilized to examine the cirrus and marine stratus clouds. The cirrus and stratus distributions were obtained, respectively, based on the spectral difference in the infrared window region, and the absorption of water vapor and $CO_2$ in the spectral region $870-980cm^{-1}$. The MSU Ch1 data has been used for low tropospheric temperature and hydrometeors, while the Ch2, Ch3 and Ch4, respectively, for the thermal state of midtroposphere, tropopause, and lower stratosphere. The climatic aspects of El Ni$\tilde{n}$o, Quasi-Biennial Oscillation (QBO) and temperature trends over the globe are discussed with the MSU data. This study suggests that the IRIS and MSU data are useful for monitoring the hydrometeors and atmospheric thermal state in climate system.

Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter (겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석)

  • Cheong, Seong-Ir;Sheng, Nai-Li;Kim, Doo-Hyun;Lee, Jae-Keun;Hwang, Yu-Jin;Park, Jong-Hoon;Seo, Seok-Jang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.7
    • /
    • pp.402-408
    • /
    • 2009
  • In this paper, the effects of ventilation and humidification on thermal comfort and indoor air quality(IAQ) were evaluated in a classroom when a heat pump system was operated in winter. Thermal comfort parameters, such as temperature, relative humidity, globe temperature and air velocity, were measured at 9 points in the classroom. The concentration of $CO_2$ and total suspended particles(TSP) in the classroom were measured in order to analyze IAQ. Temperature distribution in the classroom was decreased by $2{\sim}5^{\circ}C$ when the ventilation system and the humidifier were operated. When the relative humidity was adjusted to 60% by operating the humidifier and the ventilation system, the predicted mean vote(PMV) in the classroom was within the comfortable range of $-0.5{\sim}0.5$. When the ventilation system was operated, the average concentration of $CO_2$ and TSP were decreased by 645 ppm and 0.17 $mg/m^3$, respectively. This paper suggests the humidification and ventilation conditions to maintain the comfortable environment in the school classroom in winter experimentally.

Climate Warming and Occupational Heat and Hot Environment Standards in Thailand

  • Phanprasit, Wantanee;Rittaprom, Kannikar;Dokkem, Sumitra;Meeyai, Aronrag C.;Boonyayothin, Vorakamol;Jaakkola, Jouni J.K.;Nayha, Simo
    • Safety and Health at Work
    • /
    • v.12 no.1
    • /
    • pp.119-126
    • /
    • 2021
  • Background: During the period 2001 to 2016, the maximum temperatures in Thailand rose from 38-41℃ to 42-44℃. The current occupational heat exposure standard of Thailand issued in 2006 is based on wet bulb globe temperature (WBGT) defined for three workload levels without a work-rest regimen. This study examined whether the present standard still protects most workers. Methods: The sample comprised 168 heat acclimatized workers (90 in construction sites, 78 in foundries). Heart rate and auditory canal temperature were recorded continuously for 2 hours. Workplace WBGT, relative humidity, and wind velocity were monitored, and the participants' workloads were estimated. Heat-related symptoms and signs were collected by a questionnaire. Results: Only 55% of the participants worked in workplaces complying with the heat standard. Of them, 79% had auditory canal temperature ≤ 38.5℃, compared with only 58% in noncompliant workplaces. 18% and 43% of the workers in compliant and noncompliant workplaces, respectively, had symptoms from heat stress, the trend being similar across all workload levels. An increase of one degree (C) in WBGT was associated with a 1.85-fold increase (95% confidence interval: 1.44-2.48) in odds for having symptoms. Conclusion: Compliance with the current occupational heat standard protects 4/5 of the workers, whereas noncompliance reduces this proportion to one half. The reasons for noncompliance include the gaps and ambiguities in the law. The law should specify work/rest schedules; outdoor work should be identified as an occupational heat hazard; and the staff should include occupational personnel to manage heat stress in establishments involving heat exposure.

Regional Characteristics of Global Warming: Linear Projection for the Timing of Unprecedented Climate (지구온난화의 지역적 특성: 전례 없는 기후 시기에 대한 선형 전망)

  • SHIN, HO-JEONG;JANG, CHAN JOO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.21 no.2
    • /
    • pp.49-57
    • /
    • 2016
  • Even if an external forcing that will drive a climate change is given uniformly over the globe, the corresponding climate change and the feedbacks by the climate system differ by region. Thus the detection of global warming signal has been made on a regional scale as well as on a global average against the internal variabilities and other noises involved in the climate change. The purpose of this study is to estimate a timing of unprecedented climate due to global warming and to analyze the regional differences in the estimated results. For this purpose, unlike previous studies that used climate simulation data, we used an observational dataset to estimate a magnitude of internal variability and a future temperature change. We calculated a linear trend in surface temperature using a historical temperature record from 1880 to 2014 and a magnitude of internal variability as the largest temperature displacement from the linear trend. A timing of unprecedented climate was defined as the first year when a predicted minimum temperature exceeds the maximum temperature record in a historical data and remains as such since then. Presumed that the linear trend and the maximum displacement will be maintained in the future, an unprecedented climate over the land would come within 200 years from now in the western area of Africa, the low latitudes including India and the southern part of Arabian Peninsula in Eurasia, the high latitudes including Greenland and the mid-western part of Canada in North America, the low latitudes including Amazon in South America, the areas surrounding the Ross Sea in Antarctica, and parts of East Asia including Korean Peninsula. On the other hand, an unprecedented climate would come later after 400 years in the high latitudes of Eurasia including the northern Europe, the middle and southern parts of North America including the U.S.A. and Mexico. For the ocean, an unprecedented climate would come within 200 years over the Indian Ocean, the middle latitudes of the North Atlantic and the South Atlantic, parts of the Southern Ocean, the Antarctic Ross Sea, and parts of the Arctic Sea. In the meantime, an unprecedented climate would come even after thousands of years over some other regions of ocean including the eastern tropical Pacific and the North Pacific middle latitudes where an internal variability is large. In summary, spatial pattern in timing of unprecedented climate are different for each continent. For the ocean, it is highly affected by large internal variability except for the high-latitude regions with a significant warming trend. As such, a timing of an unprecedented climate would not be uniform over the globe but considerably different by region. Our results suggest that it is necessary to consider an internal variability as well as a regional warming rate when planning a climate change mitigation and adaption policy.

Prioritizing for Selection of New High-heat Risk Industries and Thermal Risk Assessment (신규 고열 위험 업종 선정을 위한 우선순위 및 온열 위험 평가)

  • Saemi Shin;Hea Min Lee;Nosung Ki;Jeongmin Park;Sang-Hoon Byeon;Sungho Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.230-246
    • /
    • 2023
  • Objectives: The climate crisis has arrived and heat-related illnesses are increasing. It is necessary to discover new high-heat risk industries and understand the environment . It is also necessary to prioritize risks of industries that have not been included in the management target to date. The study was intended to monitor and evaluate the thermal risk of high-priority workplaces. Methods: A prioritization method was developed based on five factors: occurrence of and death due to heat-related illnesses, work environment monitoring, indoor work rate, small heat source, and limited heat dissipation. it, was applied to industrial accidents caused by heat-related illnesses. Wet bulb temperature index and apparent temperature were measured in July and August at 24 workplaces in seven industries and assessed for thermal risk. Results: The wet bulb temperature index was in the range of 23.8~31.9℃, and exposure limits were exceeded in the growing of crops, food services activities and accommodation, and building construction. The apparent temperature was in the range of 26.8~36.7℃, and exceeded the temperature standard for issuing heatwave warnings in growing of crops, food services activities and accommodation, warehousing, welding, and building construction. Both temperature index in growing of crops and building construction were higher than the outside air temperature. Conclusions: In the workplace, risks in industries that have not be controlled and recognized through existing systems was identified. it is necessary to provide break times according to the work-rest time ratio required during dangerous time period.