• 제목/요약/키워드: GIL(Gas Insulated Transmission Line)

검색결과 12건 처리시간 0.027초

EMTP/ATPDraw를 이용한 가스절연송전선로(GIL)의 과전압 분석 (An Analysis on the Overvoltage in Gas Insulated Transmission Lines with EMTP/ATPDraw)

  • 박흥석;한상옥
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.999-1004
    • /
    • 2011
  • Nowadays, it is becoming difficult to secure a transmission line route when a new transmission line is constructed due to social environment and resident complaints. As existing urban areas are expanded and new cities are constructed, the necessity of high-capacity underground power transmission has been increasing because of load concentration in downtown areas. In North America, Europe and Japan, the research has been carried out for 2nd generation gas insulated transmission lines(GIL) which is more environmentally friendly and economical compared to previous GILs. The new GILs have been applied to real power systems from early 2000s. In South Korea, GIL is being considered as a possible solution for replacing 345kV high-capacity overhead transmission lines with underground transmission ones, so KEPCO is planning to develop and apply a new 362kV rated GIL underground transmission lines instead of overhead transmission lines. In this paper, the overvoltage generated at the combined transmission line adapting GIL was reviewed using EMTP.

UHF센서를 이용한 가스절연송전선로 절연파괴 위치 추정에 관한 연구 (A Study on Estimation of Breakdown Location using UHF Sensors for Gas Insulated Transmission Lines)

  • 박흥석;한상옥
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.805-810
    • /
    • 2011
  • This paper deals with the method and algorithm used to find fault locations in gas insulated transmission line. The method uses UHF sensors and digital oscilloscope to detect discharge signals emitted to the outside through insulating spacer in the event of breakdown inside GIL. UHF sensors are the external type and installed at outside of insulating spacers of GIL. And we used wavelet signal processing to analyze the discharge signals and confirm the exact fault location findings in the GIL test line. This method can overcome demerit of TDR(Time Domain Reflectometer) method having been applied to detect fault location for conventional underground transmission lines, and Ground Fault Sensors used in conventional GIS systems. TDR method requires high level of specialty and experience in analyzing the measured signals. Ground fault sensors are installed inside GIL and can be destroyed by high transient voltage. This paper's method can simplify the fault location process and minimize the damage of sensors. In addition, this method can estimate the fault location only by the time difference when discharge signals are arrived to detecting sensors at the ends of GIL sections without reasons of breakdown. To test the performance of our method, we installed sensors at the ends of test line of GIL(84m) and sensed discharge signals occurred in GIL, energized with AC voltage generator up to 700kV.

GIL(Gas Insulated Line)에 관한 신기술 동향 및 특징 (New technology trend and characteristic for GIL)

  • 정시환;김철수;강철원;김완식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.99-101
    • /
    • 2006
  • As the same concept with GIB, GIL(Gas Insulated Line) has been established and run for the first time in New Jersey, America, in 1972. At the beginning, the installation condition of GIL was complicated and the construction cost was excessive, so it was not economical, but the construction cost was substantially reduced with the use of insulation material which is the mixture of $SF_6$ and $N_2$ Gas in Germany, in 1990s. And also comparing to cable, GIL has lots of advantages, such as being capable of the high voltage transmission, being applied to reclosing and lowering the strength of electromagnetic force, Due to these advantages, GIL is recently accepted in many countries.

  • PDF

가스절연송전선로(GIL) PQ시험 방안에 관한 연구 (A Study on the Method of Performance Qualification Test for GIL)

  • 박흥석;한상옥
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1062-1067
    • /
    • 2011
  • As the expension of metropolis and increasing of housing site, GIL(Gas Insulated Line) comes to the fore as an alternative to overhead transmission line avoided by local resident. The certification and experimental test for the GIL is now in progress in under ground test lab, Go-chang. For the test, we propose a method of PQ(pre-qualification) test which is essential for development and field application in this paper. The test following this method take about 200 days or 300 days under the circumstances.

가스절연송전선로의 서지특성 분석에 관한 연구 (A Study on Analysis of Surge Characteristics on Gas Insulated Transmission Lines)

  • 정채균;박흥석;강지원;장태인;윤종건;김양상;석광현;김형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.371_372
    • /
    • 2009
  • This paper describes surge characteristics on 345kV combined transmission system mixed overhead line and GIL(Gas Insulated Transmission Line). Then, it is compared with the results of the system mixed overhead line and XLPE power cables. Finally the lightning overvoltages are also discussed according to surge arrester installation in two kinds of combined transmission systems when the lighting strikes on the phase conductor.

  • PDF

GIL-가공송전선로 연계시 뇌써지에 의한 과전압 검토 (Overvoltage Analysis on GIL - Overhead Transmission Line by Lightning Surge Conditions)

  • 박흥석;장태인;강지원;윤형희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.143-144
    • /
    • 2008
  • 최근 국내에서 가스절연송전선(GIL: Gas Insulated Transmission Line)의 실계통 도입을 인하여 345kV급 GIL의 개발 및 적용을 위한 연구 및 검토가 수행되고 있다. 이 중의 하나가 가공송전선로 사이의 일부구간을 지중화 하여 GIL로 대치할 경우에 나타날 수 있는 써지에 의한 과전압의 검토이다. 가공선로의 일부구간을 GIL로 대치하는 데 있어서, 변전소 단이 원거리일 경우에는 변전소 내부의 차단기나 단로기 등 개폐 써지에 의한 과전압의 영향은 감쇄효과로 인하여 그다지 크지 않으며, 뇌써지에 의한 과전압이 주요 영향 요소로 작용하고 있다. 따라서, 본 논문은 뇌써지에 의한 GIL-가공선로 구간의 과전압을 검토하기 위하여 GIL과 인접한 가공선로 구간에 낙뢰가 유입된 경우를 가정하여 GIL에 발생되는 과전압 및 보호협조 방안을 분석한다.

  • PDF

가스절연 송전선로의 허용전류에 대하여 (Calculation of Rating Current of Gas Insulated Transmission Line)

  • 남석현;심성익;안미경;박신우;장태인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 합동춘계학술대회 논문집 전기물성,응용부문
    • /
    • pp.121-122
    • /
    • 2008
  • 본 논문에서는 345kV 가스절연 송전선로(GIL)의 도체, 외함 및 절연가스에 대한 열전달 특성을 검토하여 목표 허용전류를 충족하는 GIL 규격 설정 및 이의 제품 설계에 반영한 결과를 보고한다.

  • PDF

GIL-가공송전선로 연계시 개폐과전압 검토 (Analysis of Switching Overvoltage for GIL System between Overhead Transmission Lines by EMTP)

  • 박흥석;강지원;장태인;김형호;석광현;최경규;오장만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.264_265
    • /
    • 2009
  • 최근 국내에서 가스절연송전선(GIL : Gas Insulated Transmission Line)의 실계통 도입을 위하여 345kV급 GIL의 개발 및 적용을 위한 연구 및 검토가 수행되고 있다. 가공선로의 일부구간을 GIL로 대치하는 데 있어서, 변전소측이 원거리일 경우에는 변전소 내부의 차단기나 단로기 등 개폐 써지에 의한 과전압의 영향은 감쇄효과로 인하여 그다지 크지 않지만, 현재 설치 예정선로와 같이 변전소 측과의 거리가 약 2.6[km]로 짧을 경우 차단기 동작에 의한 개폐써지의 영향을 무시할 수 없게 된다. 따라서 본 논문에서는 GIL 시스템이 가공송전선로와 연계된 경우 근접한 변전소단에서 개폐를 가정하였을 때, GIL 시스템과 가공송전선로에서 발생할 수 있는 개폐과전압에 대하여 과도해석 프로그램인 EMTP를 이용하여 검토하였다.

  • PDF

가스절연 송전선로 부분방전 진단을 위한 내장형 센서 개발 (Development of internal sensor to detect partial discharge in gas insulated transmission line)

  • 김영홍;남석현;김충식;김지홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.83-84
    • /
    • 2008
  • 인구의 증가로 인한 전력수요의 증가는 가공 및 지중 송진설비의 대용량화로 이어져왔다. 그러나 최근 도시 경관과 전자파로 인한 건강 등에 대한 관심이 급증하면서 주거지 주변 송전선로 실리에 대한 민원이 증가하고 있다 을에 대한 대안으로 대용량 전력송전이 가능하고 가공 및 지중송전의 단점을 보완한 가스결연 송전선로(Gas Insulated Transmission Line, GIL)가 개발되었다. 선진국에서는 가스 절연으로 우수한 절연성능과 안정성을 가지며, 기존 교통용 터널 또는 지하 전력구에 설치함으로써 주변 경관을 해치지 않고 낮은 전계 형성 등의 장점을 가진 가스절연송전선로의 연구와 개발에 많은 노력 기울이고 있다[$1{\sim}5$]. 본 논문에서는 전력기기들의 결함진단에 많이 사용되는 부분방전 측정을 가스절연 송전선로에 적용할 수 있는 최적의 측정용 센서를 개발하여 유사한 구조를 가지는 75kV GIS Mock-up과 Free moving particle 모의 방전 셀을 이용하여 발생시킨 부분방전 신호를 측정하여, 광대역 특성을 보이는 대수주기 패치 안테나와의 성능을 비교하였다.

  • PDF

Analysis on Temperature Distribution and Current-Carrying Capacity of GIL Filled with Fluoronitriles-CO2 Gas Mixture

  • Chen, Geng;Tu, Youping;Wang, Cong;Cheng, Yi;Jiang, Han;Zhou, Hongyang;Jin, Hua
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2402-2411
    • /
    • 2018
  • Fluoronitriles-$CO_2$ gas mixtures are promising alternatives to $SF_6$ in environmentally-friendly gas-insulated transmission lines (GILs). Insulating gas heat transfer characteristics are of major significance for the current-carrying capacity design and operational state monitoring of GILs. In this paper, a three-dimensional calculation model was established for a GIL using the thermal-fluid coupled finite element method. The calculated results showed close agreement with experimentally measured data. The temperature distribution of a GIL filled with the Fluoronitriles-$CO_2$ mixture was obtained and compared with those of GILs filled with $CO_2$ and $SF_6$. Furthermore, the effects of the mixture ratio of the component gases and the gas pressure on the temperature rise and current-carrying capacity of the GIL were analyzed. Results indicated that the heat transfer performance of the Fluoronitriles-$CO_2$ gas mixture was better than that of $CO_2$ but worse than that of $SF_6$. When compared with $SF_6$, use of the Fluoronitriles-$CO_2$ gas mixture caused a reduction in the GIL's current-carrying capacity. In addition, increasing the Fluoronitriles gas component ratio or increasing the pressure of the insulating gas mixture could improve the heat dissipation and current-carrying capacity of the GIL. These research results can be used to design environmentally-friendly GILs containing Fluoronitriles-$CO_2$ gas mixtures.