• Title/Summary/Keyword: GIC

Search Result 110, Processing Time 0.022 seconds

A New Porous Carbon via an Exfoliation of n-Octylammonium Tetrachloroferrate(III)-Graphite Intercalation Complex

  • 권채원;김동훈;최진호
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.10
    • /
    • pp.1113-1116
    • /
    • 1998
  • A new graphite intercalation compound (GIC), n-octylammonium tetrachlorofeffate(Ⅲ)-graphite, has been derived from well-known ferric chloride graphite intercalation compound. X-ray diffration study shows that the basal spacing of this new GIC is 20.8 Å. In order to investigate the local geometry around the iron atom in the graphite layers, X-ray absorption spectroscopy experiments were performed. The first discharge capacity of its exfoliated form is found to be 862 mAh/g, which is more than double the value of pristine graphite (384 mAh/g). Such a drastic increase implies that the exfoliated graphite is a promising electrode material.

A STUDY ON THE BOND STRENGTHS OF LIGHT-CURING GLASS IONOMER CEMENTS TO DENTAL AMALGAM (광중합 Glass Ionomer Cement와 Amalgam의 결합강도에 관한 연구)

  • Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.357-364
    • /
    • 1996
  • The purpose of this study was to asses the shear bond strengths of 3 types of light-curing Glass Ionomer cement to dental amalgam with or without an intermediary agent. 60 amalgam adherent specimens were prepared and aged in water at $37^{\circ}C$ for 3 days. Before bonding, the amalgam surfaces were finished flat on 600-grit silicon carbide paper. 30 specimens among 60 were used for bonding in this condition, and the other 30 were covered with a thin layer of light-curing intermediary agent. Shear bond strengths were measured with universal testing machine (Instron, Model 4301) and statistically processed by ANOVA and t-test. On completion of bond test, the fracture surfaces were examined under light microscope so that the mode of bond failure could be assessed The results were as follows : 1. Bond strength of Fuji II LC group showed the hightest value and was followed by Vitremer, Vitrebond groups (p<0.05). 2. The bond strengths achieved without an intermediary agent were higher than those obtained with intermediary agent (p<0.05). 3. For the specimens bonded with intermediary agent, bond failures occured mostly at the agent-amalgam interface. So, the use of intermediary bonding agent was thought not recommendable at glass ionomer-amalgam interface.

  • PDF

STUDY ON THE INTERFACE BETWEEN LIGHT-CURED GLASS IONOMER BASE AND INDIRECT COMPOSITE RESIN INLAY AND DENTIN (기저재용 광중합형 글래스아이오노머의 치질 및 복합 레진 인레이에 대한 접착양상)

  • Lee, Song-Hee;Kim, Dong-Jun;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.158-169
    • /
    • 2005
  • This study was done to evaluate the shear bond strength between light-cured glass ionomer cement (GIC) base and resin cement for luting indirect resin inlay and to observe bonding aspects which is produced at the interface between them by SEM. Two types of light cured GIC (Fuji II LC Improved, GC Co. Tokyo, Japan and Vitrebond$^{TM}$, 3M, Paul Minnesota U.S.A) were used in this study. For shear bond test, GIC specimens were made and immersed in 37$^{\circ}C$ distilled water for 1 hour, 24 hours, 1 week and 2 weeks. Eighty resin inlays were prepared with Artglass$^{(R)}$ (Heraeus Kultzer Germany) and luted with Variolink$^{(R)}$ II (Ivoclar Vivadent, Liechtenstein). Shear bond strength of each specimen was measured and fractured surface were examined. Statistical analysis was done with one-way ANOVA. Twenty four extracted human third molars were selected and Class II cavities were prepared and GIC based at axiopulpal lineangle. The specimens were immersed in 37$^{\circ}C$ distilled water for 1 hour, 24 hours, 1 week and 2 weeks. And then the resin inlays were luted to prepared teeth. The specimens were sectioned vertically with low speed saw. The bonding aspect of the specimens were observed by SEM (JSM-5400$^{(R)}$, Jeol, Tokyo, Japan) .There was no significant difference between the shear bond strength according to storage periods of light cured GIC base. And cohesive failure was mostly appeared in GIC On scanning electron micrograph, about 30 - 120 $\mu$m of the gaps were observed on the interface between GIC base and dentin. No gaps were observed on the interface between GTC and resin inlay.

Frequency Controllable Wide-Beam Ultrasonic Transducer with Transverse Mode (압전 횡효과를 이용한 무지향성 주파수가변 초음파트랜스듀서)

  • Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol;Kang, Kab-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.417-423
    • /
    • 2004
  • In order to obtain wide-beam characteristics and variable resonant frequency of a ultrasonic transducer for the array source, an electrode of transverse mode piezoelectric vibrator is divided, and an electronic inductance is connected to the divided electrodes. The electronic inductance is made by GIC (General Impedance Converter) circuit. Because the GIC circuit is made of OP-Amps and other passive elements, the value of the inductance can be selected easily. As the results, the electronic inductance is variable in the range from 0.2 mH to 1.2 mH. Using the inductance, the resonance frequency of the transducer can be changed in the range from 73 kHz to 86 kHz. In the directivity of the transducer, it is confirmed that the beam width of the transducer is wider than $80^{\circ}$ at -3 dB in water.

Comparison of Shear Bond Strength of Different Restorative Materials to Tricalcium Silicate-Based Pulp Capping Materials (Tricalcium Silicate-Based 치수복조재에 대한 수 종 수복재의 전단결합강도 비교)

  • Jeong, Hwakyong;Lee, Nanyoung;Lee, Sangho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.2
    • /
    • pp.200-209
    • /
    • 2017
  • The aim of this study was to evaluate the shear bond strength (SBS) of three typical restorative materials - glass ionomer cement (GIC), resin-modified glass ionomer (RMGIC) and composite resin (CR) - to different pulp capping materials, i.e., Theracal $LC^{TM}$ (TLC), $Biodentine^{TM}$ (BD), and $ProRoot^{TM}$ white MTA (WMTA). 90 acrylic blocks with a center hole were prepared. The holes were completely filled with three pulp capping materials (TLC, BD, and WMTA), with 30 specimens per capping material. The samples were then randomly divided into 3 subgroups of 10 specimens each and were overlaid with GIC, RMGIC, or CR. A total 9 specimen groups were prepared. The SBS was assessed using a universal testing machine. Kruskal-Wallis test and Mann-Whitney's test were performed to compare the SBS among the subgroups (p < 0.05). After the SBS test, the fractured surfaces were examined under a stereomicroscope at a magnification of $25{\times}$. The highest and lowest SBS values were recorded for TLC-CR and TLC-GIC, respectively. With regard to the SBS to the three pulp capping materials, CR was found to be superior to RMGIC and GIC. BD showed a higher SBS compared to TLC and WMTA when used with GIC.

Antibacterial and Mechanical Properties of Glass Ionomer Cements Containing Functionalized Multi-wall Carbon Nanotube(MWCNT) (기능화 다중벽 탄소나노튜브를 첨가한 글라스아이오노머 시멘트의 항균효과 및 기계적 성질)

  • Jeong, Mi-Ae;Kim, Dong-Ae
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.300-306
    • /
    • 2017
  • The purpose of this study was to investigate the antibacterial effect of functional multiwall carbon nanotube (MWCNT) on the conventional glass ionomer cement(GIC). The MWCNT was incorporated into a commercial powder at 0.125, 0.25, 0.5 and 1.0 wt%. Specimens for vickers hardness(VHN) disks(Ø$10mm{\times}2mm$) each were prepared. Indention were made using a load of 200 N and 20 s dwell on four specimens for each distilled water storage time 1d, 7d, and 14days. The antibacterial effects using agar diffusion test with S. mutans and S. aureus. The diameters of the inhibition zones produced around the materials were measured. The results revealed that all the vickers hardness values were increase significantly with incubation time(p<0.05). Regarding the antibacterial effect for S. mutans, all the tested groups showed a slightly higher value not significantly with the control group(p<0.05). However S. aureus statistical analysis indicated a significant difference for antibacterial agents between control and MWCNT containing 0.25 wt%(p<0.05). These results of this study provide that the conventional GIC with containing MWCNT show good antibacterial effect against and favorable mechanical properties. Further this study on the efficient functionalization of multiwall carbon nanotube will be needed.

Synthesis and Characterization of Li-Graphite intercalation Compounds (리튬-흑연 층간 화합물의 합성 및 특성)

  • Oh, Won-Chun;Kim, Myung-Kun;Ko, Young-Shin
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.315-320
    • /
    • 1994
  • Li-GICs as a high performance energy storager were synthesized as a function of the Li content by the admixture and add-pressure method. The characteristics of these prepared compounds have been determined from the studies by X-ray diffraction, UV-VIS spectrometry and CHN analysis. It follows from the results of X-ray diffraction that the lower-stage intercalation compounds are formed as the Li contents increase, however the mixed stages in these compounds are also observed. In the case of the $Li_{40wt%}$, the compound with the structure of stage 1 has been predominently, but the structure of only stage 1 is not obtained. The $d_{001}$ value of stage 1 was determined to be ca. $3.70{\AA}$. An analysis of spectrometric data shows that each of the compounds gives distingushible energy state spectra. It is seen from the spectra that the positions of $R_{min}$ values, with increase in the Li contents, are shifted in the region of higher energy state. Such a result can be attributed to the formation of stable stages. The results of CHN analysis allow us to find the mixing state related to chemical compositions of the intercalated compounds and the superiority to admixture and add-pressure method. From the results determined, it reveals that $Li_{10wt%}$-GIC and $Li_{20wt%}$-GIC can be utilized for an anode of rechargable battery.

  • PDF

The Method for Harmonics Elimination of a Single Phase Current by the Analog Relay Control Circuit and Passive Filters (릴레이 구동회로 및 수동필터를 이용한 단상 전원의 부하 적응형 고조파 전류 제거 기법)

  • Park, Jong-Yeon;Lee, Hu-Chan;Lee, Bong-Jin;Choi, Won-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.6
    • /
    • pp.292-298
    • /
    • 2006
  • Because of the high cost for the active power filter, passive filters have been widly used to eliminate harmonic currents of nonlinear load and can also improve the power factor. They are not often optimal filters because the passive filters are designed under the fixed load conditions. In this paper we proposed the method which only the necessary harmonic filters are operated by detecting the various harmonic current components. We presents the new control method of passive filter selection type with the relay control circuit which is consist of analog GIC, comparater, flip-flop and etc. By the experimental results using the proposed system for the rectifier load, we concluded that the researched method is cost effective and the performance is better than the passive filter.

Design Method and Characteristics of WDF based on VGIC (전압 변환 GIC에 의한 WDF의 설계 방법 및 특성)

  • 박종연;장목순
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.9
    • /
    • pp.45-53
    • /
    • 1993
  • In this paper the voltage controlled GIC is classified into two structures, one has the dependent port conductance and the other has the independent port conductance. Nine kinds of configuration for the WDF with two voltage controlled GICs have been found and the design method for WD-LPF has been shown as an example. Their hardware complexity and amplitude characteristics are nearly same as the existing ones, but amplitude error according to coefficient quantization is reduced to about 5% of the error in existing structures. As the result of the numerical analysis of the RPSD to check up the product quantization effect at the WDF output, four kinds of proposed structures have about 10dB less RPSD than existed ones for 6 bits .leq.B .leq.20 bits.

  • PDF

Oil Adsorption of Exfoliated Graphite Prepared by Direct Reaction between $SO_3$ Gas and Graphite

  • Lee, Beom-Jae;Kwon, Young-Bae
    • Carbon letters
    • /
    • v.2 no.1
    • /
    • pp.55-60
    • /
    • 2001
  • Graphite intercalation compounds (GIC) were prepared by direct reaction of $SO_3$ gas with flake graphite. The intercalated $SO_3$ molecules were ejected by rapid heating to $950^{\circ}C$ under an oxidizing atmosphere for about 1 minute, resulting in surprisingly high expansion in the direction of c-axis. The characteristics of the micro-structure and pore size distribution were examined with a SEM and mercury intrusion porosimetry. The XRD analysis and spectroscopic analysis were used for the identification of the graphite and surface chemistry state. The pore size distribution of the exfoliated graphite (EG) was a range of $1{\sim}170{\mu}m$. The higher expanding temperature the higher expanded volume, so oil sorption capacities were 58.8 g of bunker-C oil and 34.7 g of diesel oil per 1 g of the the EG. The sorption equilibrium was achieved very rapidly within several minutes. As the treatment temperature increases, bulk density decreases.

  • PDF