• Title/Summary/Keyword: GFRP composite

Search Result 324, Processing Time 0.033 seconds

Stress-strain Relations of Concrete Confined with Tubes Having Varying GFRP Layers (수적층 및 필라멘트 와인딩을 이용한 GFRP튜브로 구속된 콘크리트의 압축 거동)

  • Lee, Sung Woo;Choi, Sokhwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6A
    • /
    • pp.861-872
    • /
    • 2008
  • Concrete-filled glass fiber reinforced polymer tubes are often used for marine structures with the benefit of good durability and high resistance against corrosion under severe chemical environment. Current research presents results of a comprehensive experimental investigation on the behavior of axially loaded circular concrete-filled glass fiber reinforced polymer tubes. This paper is intended to examine several aspects related to the usage of glass fiber fabrics and filament wound layers used for outer shell of piles subjected to axial compression. The objectives of the study are as follows: (1) to evaluate the effectiveness of filament winding angle of glass fiber layers (2) to evaluate the effect of number of GFRP layers on the ultimate load and ductility of confined concrete (3) to evaluate the effect of loading condition of specimens on the effectiveness of confinement and failure characteristics as well, and (4) to propose a analytical model which describes the stress-strain behavior of the confined concrete. Three different types of glass fiber layers were chosen; fabric layer, ${\pm}45^{\circ}$ filament winding layer, and ${\pm}85^{\circ}$ filament winding layer. They were put together or used independently in the fabrication of tubes. Specimens that have various L:D ratios and different diameters have also been tested. Totally 27 GFRP tube specimens to investigate the tension capacity, and 66 concrete-filled GFRP tube specimens for compression test were prepared and tested. The behavior of the specimens in the axial and transverse directions, failure types were investigated. Analytical model and parameters were suggested to describe the stress-strain behavior of concrete under confinement.

A Study on the Dielectric Strength of Composite Materials(I) (복합재료의 전기적 절연특성과 개발에 관한 연구(I))

  • 정은식;강창남;박정후
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.8
    • /
    • pp.323-330
    • /
    • 1985
  • Dielectric loss tangent and ac dielectric strength of GFRP (Glass Fiber Reinforced Plastics, G-10)was investigated as parameters of mechanical and thermal stresses, in order to study the basic dielectrical characteristics of composite insulating materials. The dielectric loss tangent was increased and the ac dielectric strength was decreased with increase in the mechanical stresses beyond the mechanical yield point on account of fiber-matrix debonding, but the dielectric constant was not varied sigificantly. the dielectric strength of G-10 was about 2 MV/cm and the dielectric constant was about 4.8.

  • PDF

Development of Composite Deck with Vertical Snap-Fit Connection for its Application to Pedestrian Bridges (수직결합형 복합소재 데크 개발과 보도교 바닥판 적용 연구)

  • Lee, Sung-Woo;Hong, Kee-Jeung;Kim, Hyoung-Taek;Cho, Sung-Hwan;Sim, Young-Sik
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.539-544
    • /
    • 2007
  • Glass fiber reinforced composite decks have high-strength, light-weight and high durability. The composite decks having vertical snap-fit connections are designed for pedestrian bridges and their structural behaviour are studied. The existing connection method of the composite decks in horizontal direction is replaced by the developed snap-fit connection method in vertical direction. The section shape of the composite decks having the vertical snap-fit connection is designed. The safety of the vertical snap-fit connection is verified by finite element analysis.

  • PDF

Viscoelastic behavior on composite beam using nonlinear creep model

  • Jung, Sung-Yeop;Kim, Nam-Il;Shin, Dong Ku
    • Steel and Composite Structures
    • /
    • v.7 no.5
    • /
    • pp.355-376
    • /
    • 2007
  • The purpose of this study is to predict and investigate the time-dependent creep behavior of composite materials. For this, firstly the evaluation method for the modulus of elasticity of whole fiber and matrix is presented from the limited information on fiber volume fraction using the singular value decomposition method. Then, the effects of fiber volume fraction on modulus of elasticity of GFRP are verified. Also, as a creep model, the nonlinear curve fitting method based on the Marquardt algorithm is proposed. Using the existing Findley's power creep model and the proposed creep model, the effect of fiber volume fraction on the nonlinear creep behavior of composite materials is verified. Then, for the time-dependent analysis of a composite material subjected to uniaxial tension and simple shear loadings, a user-provided subroutine UMAT is developed to run within ABAQUS. Finally, the creep behavior of center loaded beam structure is investigated using the Hermitian beam elements with shear deformation effect and with time-dependent elastic and shear moduli.

Cyclic behavior of steel I-beams modified by a welded haunch and reinforced with GFRP

  • Egilmez, O. Ozgur;Alkan, Deniz;Ozdemir, Timur
    • Steel and Composite Structures
    • /
    • v.9 no.5
    • /
    • pp.419-444
    • /
    • 2009
  • Flange and web local buckling in beam plastic hinge regions of steel moment frames can prevent beam-column connections from achieving adequate plastic rotations under earthquake-induced forces. Reducing the flange-web slenderness ratios (FSR/WSR) of beams is the most effective way in mitigating local member buckling as stipulated in the latest seismic design specifications. However, existing steel moment frame buildings with beams that lack the adequate slenderness ratios set forth for new buildings are vulnerable to local member buckling and thereby system-wise instability prior to reaching the required plastic rotation capacities specified for new buildings. This paper presents results from a research study investigating the cyclic behavior of steel I-beams modified by a welded haunch at the bottom flange and reinforced with glass fiber reinforced polymers at the plastic hinge region. Cantilever I-sections with a triangular haunch at the bottom flange and flange slenderness ratios higher then those stipulated in current design specifications were analyzed under reversed cyclic loading. Beam sections with different depth/width and flange/web slenderness ratios (FSR/WSR) were considered. The effect of GFRP thickness, width, and length on stabilizing plastic local buckling was investigated. The FEA results revealed that the contribution of GFRP strips to mitigation of local buckling increases with increasing depth/width ratio and decreasing FSR and WSR. Provided that the interfacial shear strength of the steel/GFRP bond surface is at least 15 MPa, GFRP reinforcement can enable deep beams with FSR of 8-9 and WSR below 55 to maintain plastic rotations in the order of 0.02 radians without experiencing any local buckling.

Effect to Material Strength Recovery of Stepped Patch Repair with Epoxy based Particle Reinforced GFRP Composites under Hygrothermal Environment (에폭시 기지 입자 강화 GFRP를 사용한 계단형 패치 보수법이 고온 고습 환경하에서 재료의 물성 회복에 미치는 영향)

  • Jung, Kyung-Seok;Park, Soo-Jeong;Kim, Yun-Hae
    • Composites Research
    • /
    • v.31 no.3
    • /
    • pp.88-93
    • /
    • 2018
  • In this study, damaged composite laminates were repaired by a stepped patch repair method using halloysite nanotube(HNT) and milled carbon(MC) reinforced composite materials with different amount of the particles. And the mechanical and structural effects of the particles on the interface between the damaged and repair surfaces were analyzed. At this time, after exposing them to a harsh environment of high temperature and humidity for a long time, the recovery rate of the material properties relative to the material forming the damaged plate was compared. As a result, at $70^{\circ}C$ high temperature distilled water, the hygroscopicity of the HNT/GFRP composites was significantly different from that of the MC/GFRP composites. Especially, 0.5, 1 wt. % HNT was added, the moisture absorption rate was the lowest and this was the factor that contributed to the mechanical strength increase. On the other hand, MC showed a high hygroscopic resistance only with a small amount, and the strength was different according to the action direction of the load, and the addition amount was also different.

Performance Evaluation of Bending Strength of Curved Composite Glulams Made of Korean White Pine (잣나무 만곡 복합집성재의 휨강도 성능평가)

  • Song, Yo-Jin;Jung, Hong-Ju;Lee, In-Hwan;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.4
    • /
    • pp.463-469
    • /
    • 2015
  • In this study, to improve bending strength performance of Korean white pine, we made the curved composite glulam that was reinforced with glass fiber materials and larch lamina. Five types of Korean white pine curved glulams were made depending on whether they had been reinforced or not and how they had been reinforced. Type-A, reference specimen, was produced only with Korean white pine lamina, and Type-B was with larch lamina in the same thickness. Type-C was made by inserting a glass fiber cloth of textile shape between the each layer. Type-D was reinforced with two glass fiber cloths, which were placed inside and outside of the outermost lamina. Type-E was reinforced with GFRP sheet in the same way as Type-D. As a result of this bending strength test, the modulus of rupture (MOR) of Type-B, Type-C and Type-E were increased by 29%, 6%, and 48% in comparison with Type-A. However, MOR of Type-D was decreased by 2% in comparison with Type-A. In the failure modes, Type-A, Type-B and Type-C were totally fractured at the maximum load. However, load values of Type-D and Type-E decreased slowly because of reinforcement of fracture suppression, and the GFRP sheet (Type-E) had better reinforcing effect on compressive stress and tensile stress than the glass fiber cloth (Type-D).

Characteristics of a CFRP Cruiser's Windage Area by Stability Assessment (탄소섬유강화복합재료(CFRP) 레저선박의 횡요저항력 평가에 의한 상부구조물 풍압면적 특성)

  • Kim, Do-Yun;Lee, Chang-Woo;Lee, Dong-Kun;Oh, Dae-Kyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.6
    • /
    • pp.774-780
    • /
    • 2014
  • This research aims to investigate the superstructure characteristics of the CFRP-yachts whose hulls are made of the light-weight material CFRP. CFRP-yachts, which belong to light-weight yachts, have a tendency of having very small superstructures compared to other vessels of the same length, and such a tendency is closely related to stability. In this research, a comparison of shape characteristics was made between common composite-plastic yachts and CFRP-yachts to find out the shape characteristics of CFRP-yacht. In the meantime, a case study was conducted concerning shape changes in superstructure to understand the effect of such changes on stability. For this purpose the shapes of a total of 10 GFRP-yachts and CFRP-yachts were comparatively analyzed, and the result showed the tendency of their hulls and superstructures. Whereas the case study on stability assessment involved various superstructure shapes of CFRP yachts, for assessment by superstructure size. Stability assessment was according to ISO 12217 (Small craft Stability and buoyancy assessment and categorization). A program was also developed based on stability assessment process due to rolling in beam waves and wind, and it was applied to the case study. The result of the case study showed that the windage area distribution tendency of the yachts whose hulls were made of the light-weight material CFRP was similar to that of the GFRP-yachts, but that the superstructure shapes of the CFRP-yachts were about 50% smaller than those of the GFRP-yachts. In addition, the stability assessment involving various superstructure areas of the CFRP-yachts showed that problems with stability occurred when their superstructure sizes were similar to, or larger by about 10% than, those of the GFRP-yachts.

Analysis of Defect Signals Inside Glass Fiber Reinforced Polymer Through Deconvolution of Terahertz Wave (테라헤르츠파의 디컨벌루션을 통한 유리섬유 복합재 내부 결함 신호 분석)

  • Kim, Heon-Su;Park, Dong-Woon;Kim, Sang-Il;Lee, Jong-Min;Kim, Hak-Sung
    • Composites Research
    • /
    • v.35 no.1
    • /
    • pp.8-12
    • /
    • 2022
  • Analysis of defect signals inside glass fiber reinforced polymer (GFRP) was conducted through deconvolution of terahertz (THz) wave. The GFRP specimen with internal defects was manufactured and the THz signal was measured through the reflection mode of the Terahertz Time-Domain Spectroscopy (THz-TDS) system. For deconvolution of the measured THz signal, the peak position of the THz signal was amplified through Normalized Cross Correlation (NCC) of the incident and detected THz signals. The position and intensity of the amplified peak were extracted as impulse, and the extracted signal of the impulse position was removed from the THz original signal. By repeating the process, the critical impulses, which represent boundary of the specimen, were derived. The deconvolution process was verified by confirming that the original THz signal without noise can be restored through the convolution of the critical impulses and the incident signal. From the derived critical impulses, the thickness of the internal defect in the GFRP was calculated through the detection time of impulses within 15 ㎛ accuracy.