• Title/Summary/Keyword: GC-determination

Search Result 479, Processing Time 0.028 seconds

Simultaneous Determination of Octylphenol, Nonylphenol and Bis(2-ethylhexyl)phthalate in Fish Samples Using Two Internal Standards (2가지 내부표준물질을 이용하여 어류시료 중 Octylphenol, Nonylphenol, Bis(2-ethylhexyl)phehalate의 동시정량)

  • Kim, Jong-Hun
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.244-252
    • /
    • 2001
  • A comprehensive analytical method of endocrine distruptors[i.e., nonylphenol(NP), octylphenol(OP), bis(2-ethylhexyl)phthalate(BEHP)] is fish samples was developed using two internal standards. This method employed closed culture tube extraction with dichloromethane and solvent exchange to iso-hexane and SPE(2g) aminopropyl column, followed by determination on gas chromatograph linked to mass spectrometer(GC/MS) operated in the single ion monitoring(SIM) mode. The recoveries of nonylphenol and octyphenol in the range of $0.2{\sim}20{\mu}g/g$ using 1-phenyl decanol as one internal standard were over 75%, and recovery of bis(2-ethylhexyl)phthalate in the range of $0.4{\sim}40{\mu}g/g$ using bis(2-ethylbutyl)phthalate(BEBP) as the other internal standards was showed over 102%. The present method was applied to fish samples from Korea and UK. The range of concentrations for nonylphnol(NP) and bis(2-ethylhexyl)phthalate in Korean fish were $0.02{\sim}0.06{\mu}g/g$ in 2 samples and $0.18{\sim}2.03{\mu}g/g$ in 9 samples respectively, but bis(2-ethylhexyl)phthalate(BEHP) in UK samples was found $2.99{\mu}g/g$ in just 1 sample. But octylphenol(OP) was not dected in any samples by this method. This two internal standard method provides a more precise analytical tool to investigate endocrine disruptors in a biological matrices of limited quantity.

  • PDF

Studies on the Analysis of Benzo(a)pyrene and Its Metabolites on Biological Samples by Using High Performance Liquid Chromatography/Fluorescence Detection and Gas Chromatography/Mass Spectrometry

  • Lee, Won;Shin, Hye-Seung;Hong, Jee-Eun;Pyo, Hee-Soo;Kim, Yun-Je
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.5
    • /
    • pp.559-565
    • /
    • 2003
  • An analytical method the determination of benzo(a)pyrene (BaP) and its hydroxylated metabolites, 1-hydroxybenzo(a)pyrene (1-OHBaP), 3-hydroxybenzo(a)pyrene (3-OHBaP), benzo(a)pyrene-4,5-dihydrodiol (4,5-diolBaP) and benzo(a)pyrene-7,8-dihydrodiol (7,8-diolBaP), in rat urine and plasma has been developed by HPLC/FLD and GC/MS. The derivatization with alkyl iodide was employed to improve the resolution and the detection of two mono hydroxylated metabolites, 1-OHBaP and 3-OHBaP, in LC and GC. BaP and its four metabolites in spiked urine were successfully separated by gradient elution on reverse phase ODS $C_{18}$ column (4.6 mm I.D., 100 mm length, particle size 5 ㎛) using a binary mixture of MeOH/H₂O (85/15, v/v) as mobile phase after ethylation at 90 ℃ for 10 min. The extraction recoveries of BaP and its metabolites in spiked samples with liquid-liquid extraction, which was better than solid phase extraction, were in the range of 90.3- 101.6% in n-hexane for urine and 95.7-106.3% in acetone for plasma, respectively. The calibration curves has shown good linearity with the correlation coefficients (R²) varying from 0.992 to 1.000 for urine and from 0.996 to 1.000 for plasma, respectively. The detection limits of all analytes were obtained in the range of 0.01-0.1 ng/mL for urine and 0.1-0.4 ng/mL for plasma, respectively. The metabolites of BaP were excreted as mono hydroxy and dihydrodiol forms after intraperitoneal injection of 20 mg/kg of BaP to rats. The total amounts of BaP and four metabolites excreted in dosed rat urine were 3.79 ng over the 0-96 hr period from adminstration and the excretional recovery was less than 0.065% of the injection amounts of BaP. The proposed method was successfully applied to the determination of BaP and its hydroxylated metabolites in rat urine and plasma for the pharmacokinetic studies.

Establishment of an Analytical Method for Prometryn Residues in Clam Using GC-MS (GC-MS를 이용한 바지락 중 prometryn 잔류분석법 확립)

  • Chae, Young-Sik;Cho, Yoon-Jae;Jang, Kyung-Joo;Kim, Jae-Young;Lee, Sang-Mok;Chang, Moon-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.531-536
    • /
    • 2013
  • We developed a simple, sensitive, and specific analytical method for prometryn using gas chromatography-mass spectrometry (GC-MS). Prometryn is a selective herbicide used for the control of annual grasses and broadleaf weeds in cotton and celery crops. On the basis of high specificity, sensitivity, and reproducibility, combined with simple analytical operation, we propose that our newly developed method is suitable for use as a Ministry of Food and Drug Safety (MFDS, Korea) official method in the routine analysis of individual pesticide residues. Further, the method is applicable in clams. The separation condition for GC-MS was optimized by using a DB-5MS capillary column ($30m{\times}0.25mm$, 0.25 ${\mu}m$) with helium as the carrier gas, at a flow rate of 0.9 mL/min. We achieved high linearity over the concentration range 0.02-0.5 mg/L (correlation coefficient, $r^2$ >0.998). Our method is specific and sensitive, and has a quantitation limit of 0.04 mg/kg. The average recovery in clams ranged from 84.0% to 98.0%. The reproducibility of measurements expressed as the coefficient of variation (CV%) ranged from 3.0% to 7.1%. Our analytical procedure showed high accuracy and acceptable sensitivity regarding the analytical requirements for prometryn in fishery products. Finally, we successfully applied our method to the determination of residue levels in fishery products, and showed that none of the analyzed samples contained detectable amounts of residues.

Determination of Volatile Flavor Compounds during Storage of Cereal Added Yogurt using HS-SPME (곡류 첨가 발효유의 저장 중 HS-SPME를 이용한 휘발성 향기성분 정량분석)

  • Lim, Chan-Mook;Jhoo, Jin-Woo;Kim, Gur-Yoo
    • Food Science of Animal Resources
    • /
    • v.33 no.5
    • /
    • pp.646-654
    • /
    • 2013
  • In this study, quantitative analysis of major volatile flavor compounds from yogurt was conducted using headspace-solid phase microextraction (HS-SPME) GC-FID analysis technique, and the changes of volatile aroma compounds during the storage period were evaluated. The yogurt was prepared with the addition of 2% cereals, such as, white rice (WR), brown rice (BR), germinated brown rice (GBR) and saccharified germinated brown rice (SGBR). After fermentation, the products were stored at $5^{\circ}C$for 15 d. The major volatile aroma compounds in yogurt, such as acetaldehyde, acetone, diacetyl and acetoin were able to be extracted using HS-SPME technique efficiently. The regression ($r^2$) value of standard curve prepared with various concentrations of individual flavor chemicals was analyzed over 0.9975, and reproducibility was acceptable to apply quantitative analysis. The analysis of volatile components of control sample during storage showed that the acetaldehyde on 0 d was 10.83 ppm, and that contents were increased to 15.67 ppm after 15 d of storage. However, addition of BR, GBR and SGBR decreased the acetaldehyde contents during storage periods. The acetone content of all treatments during storage was not significantly different. The diacetyl content of all treatments were increased during storage and the addition of SGBR showed the highest amount of diacetyl (0.84 ppm) among treatments on 15 d of storage. The acetoin content of yogurt added with grains was higher than that of control during storage. As a result, the content of volatile aroma compounds in yoghurt during storage period could be analyzed HS-SPME extraction technique effectively, and HS-SPME/GC analysis can be considered for quality control of fermented milk products.

Determination of homogentisic acid in human plasma by GC-MS for diagnosis of alkaptonuria (GC-MS를 이용한 혈장 중 호모겐티식산의 분석;알캅톤뇨증의 진단)

  • Thapa, Maheshwor;Yu, Jundong;Lee, Wonjae;Islam, Fokhrul;Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.323-330
    • /
    • 2015
  • Alkaptonuria, a rare inherited metabolic disease, is characterized by a lack of homogentisate dioxygenase and accumulation of homogentisic acid (HGA), leading to homogentisic aciduria, arthritis, and ochronosis. In this study, a rapid analytical method, without an expensive and tedious solid phase extraction step, was developed to quantify HGA in plasma using GC-MS. HGA-spiked pooled plasma samples were subjected to liquid-liquid extraction (LLE) with ethyl acetate, followed by trimethylsilyl derivatization (TMS) and GC-MS quantification using selected ion monitoring. The formation of TMS derivative of the 1 carboxylic and 2 hydroxyl functional groups was performed by reacting BSTFA (with 10% TMCS) for 5 min at 80 ℃. For selected ion monitoring, quantification and confirmation ions were determined based on specific ions (m/z 384, m/z 341 and m/z 252) of the TMS derivative of HGA. Calibration curves of pooled normal plasma specimens showed a linear relationship in the range of 1-100 ng/µL. The precision and accuracy were within a relative standard deviation (RSD) of 1 to 15% and a bias of -5 to 25%. Recoveries were obtained in the range of 99-125% and 95-115% for intra-day and inter-day assay, respectively, at 2, 20 and 80 ng/µL. The limit of detection (LOD) and limit of quantification (LOQ) were 0.4 ng/µL and 4 ng/µL, respectively. No homogentisic acid was excreted from normal Korean plasma samples. Collectively, the results from the present study suggest that this method could be useful for routine diagnosis and therapeutic monitoring of alkaptonuria patients with excellent sensitivity and rapidity.

Determination of metabolites of prostanozol in human urine by LC/ESI/MS and GC/TOF-MS (LC/ESI/MS와 GC/TOF-MS를 이용한 인체뇨시료에서의 Prostanozol 대사체 검출)

  • Yum, Tae-Woo;Paeng, Ki-Jung;Kim, Yun-Je
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.173-182
    • /
    • 2011
  • This research examined prostanozol and its metabolites in urine of women who took the medicine (prostanozol). Prostanozol and its metabolites were successfully separated and detected by using LC/ESI/MS and GC/TOF-MS. Mass spectrum of LC/ESI/MS estimated molecular weight of Prostanozol and its metabolites and that of GC/TOF-MS verified them. For M1, carbon number 17 of Prostanozol substituted to a keto group and it is called 17-keto-Prostanozol. M2 turned out to be hydroxy-17-keto-Prostanozol. It came from substitution of one hydroxyl group of pyrazole nucleus and A-ring of M1. Substitution of one hydroxyl group of B-ring or C-ring became M3, hydroxy-17-keto-Prostanozol. M4 was found to be a hydroxy-17-keto-Prostsnozol transposed from one hydroxyl group to a D-ring. M5 has a hydroxyl group of carbon number 17. One hydroxyl group is substituted from B-ring or C-ring and it is assumed to be hydroxy-17-hydroxy-Prostanozol. M6 was turned out to be dihydroxy-17-keto-Prostanozol transposed from one hydroxyl group to pyrazole nucleus or A-ring and to B-ring or C-ring. Like M6, M7 has a keto group at carbon number 17 and was identified as dihydroxy-17-keto-Prostanozol. M7 has one hydroxyl group at pyrazole nucleus or A-ring and also at D-ring. At last M8 was found to be dihydroxy-17-hydroxy-Prostanozol. Pyrazole nucleus or A-ring has got one hydroxyl group and other rings were substituted to another hydroxyl group. From above, M5, M7 and M8 were verified as new metabolites that were not discovered yet. Prostanozol and all of the 8 metabolites formed glucuronic conjugates as a result of conjugation reaction test in human body. Some of 8 metabolites were excreted without forming conjugates. Particularly M6 and M7 were excreted as sulfate conjugates.

Comparative Evaluation of the Analytical Methods used to Determine Pesticide Residues in Milk via Dispersive Solid Phase Extraction (Dispersive Solid Phase Extraction을 사용한 우유 내 잔류농약 다성분 동시 분석법 비교연구)

  • Oh, Nam Su;Shin, Yong Kook;Lee, Ji Young;Baick, Seung Chun
    • Journal of Dairy Science and Biotechnology
    • /
    • v.33 no.1
    • /
    • pp.27-34
    • /
    • 2015
  • The aim of this study was to optimize a simple, fast, and economic analytical method for the simultaneous determination of various pesticides (aldrin, p,p'-DDT, o,p'-DDT, p,p'-DDE, ${\alpha}$-endosulfan, ${\beta}$-endosulfan, dieldrin, heptachlor, permethrin, chlordane, deltamethrin, diazinon, bifenthrin, methoprene, propargite, fenpropathrin, cypermethrin, fenvalerate, and fenpropathrin) in milk by using dispersive solid phase extraction (SPE). In this study, two different extraction methods (low temperature cleanup and liquid-liquid partitioning), which were followed by a cleanup process based on dispersive-SPE, were evaluated and compared for the 19 pesticides. The results for all the pesticides were determined by gas chromatography mass spectrometry (GC/MS) with selected-ion monitoring mode, and the matrix effect of the method was evaluated. Comparison of these approaches yielded higher and more consistent recoveries of most pesticides at fortification levels of $1{\mu}g/mL$ using low-temperature fat precipitation, followed by cleanup process based on dispersive-SPE with PSA and C18 as sorbents, than other preparation process. The relative standard deviation was <20 % and the combination of this method were very effective for the cleanup.

  • PDF

Simultaneous determination of 37 volatile organic compounds at ng/L concentration level in surface water by HS-SPME-GC/MS (HS-SPME-GC/MS에 의한 지표수에서 ng/L 농도 수준의 37개 휘발성유기화합물의 동시 분석)

  • Kim, Tae-Seung;Hong, Suk-Young;Kim, Jong-Eun;Lim, Hyun-Hee;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.39-49
    • /
    • 2012
  • A method to detect 37 volatile organic compounds (VOCs) in surface water was described based on headspace solid-phase micro extraction and gas chromatography-mass spectrometry. VOCs in water were vaporized for 30 min at 40 $^{\circ}C$ in a headspace vial and adsorbed on 85 ${\mu}m$ carboxen-polydimethylsiloxane. Under the established condition, the lowest quantification limit was 4.1-96 ng/L by using 4.0 mL water sample, and the relative standard deviation was less than 15% at concentrations of 0.05 and 0.50 ${\mu}g/L$. The detection limits meet lower concentration than 1/10 of the water quality criteria for VOCs established by the US EPA or Germany. The LOQ is a sensitivity which the monitoring for the establishing water quality criteria requires. When the proposed method was used to analyze the target compounds in sixteen surface water samples and total 16 VOCs were detected in surface water samples collected from Gum-River. Maximum concentrations of VOCs detected were not exceeded the EPA or Germany guidelines in any of the samples.

The Volatile Organic Compounds Released from PVC Food Wrapping Film at Normal Use Condition (식품용 PVC 포장필름의 실생활 사용환경에서 방출되는 휘발성 유기화합물)

  • Nam, Sung-Hyun;Kim, Man-Goo;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.683-692
    • /
    • 2000
  • The volatile organic compounds emitted from food wrapping films when it was used at high temperatures. However, the testing method based on solvent extraction may not be suitable for determination of volatile organic compounds from food wrapping films. Therefore, thermal extraction device was investigated in the study for reflection of actual usage conditions at home and restaurant. In this study, PVC food wrapping films were exposed to normal use condition controlled from $50^{\circ}C$ to $120^{\circ}C$ and collected on sorbent trap. Then, emitted VOCs from the films were analyzed with On-column cryofocusing-GC/MS system. The major VOCs emitted from films were $C_{12}-C_{18}$ paraffinic hydrocarbons, dimethylphthalate, alkylphenols, known as endocrine disrupting chemical, such as tetramethylbutylphenol, tert-butylphenol, and nonylphenol. The concentration of tetramethylbutylphenol emitted from PVC films was $0.07ng/cm^2$ at $50^{\circ}C$, rapidly increased with temperature, $3.94ng/cm^2$ at $100^{\circ}C$.

  • PDF

Establishment of a library of fragments for the rapid and reliable determination of anabolic steroids by liquid chromatography-quadrupole time of flight-mass spectrometry

  • Do, Jung-Ah;Noh, Eunyoung;Yoon, Soon-Byung;Choi, Hojune;Baek, Sun-Young;Park, Sung-Kwan;Lee, Sang-Gyeong
    • Analytical Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.10-19
    • /
    • 2017
  • Anabolic steroids have similar structures to testosterone, both of which promote the growth of muscle mass and increase strength. However, the side effects of anabolic steroid use may lead to heart attacks or strokes. Additionally, the excessive use of steroids inhibits the production of the sex hormones in the body via a negative feedback loop, which results in testicular atrophy in males and amenorrhea in females. Currently, the method of choice used to test for the presence of anabolic steroids is GC-MS. However, GC-MS methods require chemical derivatization of the steroid sample to ensure compatibility with the analytical method; therefore, analysis of many different samples is difficult and time consuming. Unlike GC-MS, the liquid chromatography-quadrupole-time of flight mass spectrometry (LC-Q-TOF-MS) method is suitable for many samples. Twenty-two different anabolic steroids were analyzed by LC-Q-TOF-MS with various collision energies (CE). Accurate mass spectral data were obtained using a Q-TOF-MS equipped with an electro-spray ionization source and operated in the positive MS/MS mode for several classes of steroids that are often the targets of testing. Based on the collected data, fragmentation pathways were carefully elucidated. The high selectivity and sensitivity of the LC-Q-TOF-MS instrument combined with these fragmentation pathways offers a new approach for the rapid and accurate screening of anabolic steroids. The obtained data from the 22 different anabolic steroids will be shared with the scientific community in order to establish a library to aid in the screening of illegal anabolic steroids.