• 제목/요약/키워드: GC-MS/MS

검색결과 2,429건 처리시간 0.027초

GC-MS를 이용한 식물홀몬 분석 (Analysis of Plant Hormones using GC-MS)

  • 조광연
    • 한국작물학회지
    • /
    • 제34권s01호
    • /
    • pp.26-32
    • /
    • 1989
  • The analytic principles of GC and MS were explained in relation to plant hormone analyses and the characteristics of two instruments were compared. The selection of column, condition of measurement and the method of ionization to get a good spectrum were also briefly described. Finally, the pre-treatment of sample by solvent extraction method to remove the unnecessary part of sample and the synthetic method, especially reagents and reaction condition, for the preparation of ether or ester derivative which can be easily vaporized in GC were explained.

  • PDF

EI-GC/MS/MS를 이용한 니트로사민류의 수질분석 (Determination of N-nitrosamines in Water by Gas Chromatography Coupled with Electron Impact Ionization Tandem Mass Spectrometry)

  • 이기창;박재형;이원태
    • 대한환경공학회지
    • /
    • 제36권11호
    • /
    • pp.764-770
    • /
    • 2014
  • 본 연구는 electron impact-gas chromatography/mass spectrometer (EI-GC/MS)를 이용하여 N-nitrosamines 분석하는 방법의 분리성, 정성 및 정량적 유효성을 평가하였다. 극미량의 검출을 위해 시료전처리는 자동고상추출과 질소농축과정을 거쳐 수행하였다. 표준시료를 전처리 없이 EI-GC/MS (SIM)와 EI-GC/MS/MS (MRM)를 이용하여 직접 분석한 결과, 두 방법 모두 유사한 감응도를 보였다. 반면, 전처리한 표준시료를 EI-GC/MS로 분석한 경우 불순물 피크에 의한 간섭영향에 의해 낮은 ng/L 수준의 정량은 어려운 것으로 나타났다. 8종의 N-nitrosamines에 대한 EI-GC/MS/MS 분석결과, 방법검출한계 및 정량한계는 각각 0.76~2.09 ng/L, 2.41~6.65 ng/L 수준으로 기존 분석방법에 비하여 낮게 나타났다. 첨가농도 10, 20, 100 ng/L에 대한 실험에서 정밀도(1.2~13.6%)와 정확도(80.4~121.8%) 모두 만족하였으며, 검량선의 직선성에 대한 결정계수($R^2$)도 0.999 이상이었다. 환경시료에 대한 대체표준물질(NDPA-$d_{14}$)의 회수율도 86.2~122.3%을 나타내어, 본 연구에서 평가된 방법으로 N-nitrosamines의 정밀분석이 가능함을 검증하였다.

LC-MS/MS와 GC-MS를 이용한 세신 추출물 중 7종 성분의 함량분석 (Quantitative Analysis of the Seven Marker Components in Asarum sieboldii using the LC-MS/MS and GC-MS)

  • 서창섭;신현규
    • 생약학회지
    • /
    • 제44권4호
    • /
    • pp.350-361
    • /
    • 2013
  • Asarum sieboldii has been used for treatment of fever, pain, common cold, and chronic sinusitis in Korea. In this study, we performed quantification analysis of seven major constituents including aristolochic acid I, aristolochic acid II, ${\alpha}$-asarone, ${\beta}$-asarone, elemicin, methyl eugenol, and safrole in the 70% ethanol extract of Asarum sieboldii and its solvent fractions, n-hexane, ethylacetate, n-butanol, and water ones using a ultra-performance liquid chromatography-electrospray ionization-mass spectrometer(UPLC-ESI-MS) and gas chromatography-mass spectrometer(GC-MS). Regression equations of seven components were acquired with $r^2$ values >0.99. The values of limit of detection(LOD) and quantification(LOQ) were 0.1-3.9 ng/mL and 0.3-11.7 mg/mL, respectively. The amount of the seven compounds in Asarum sieboldii were not detected -143.66 mg/g. The established LC-MS/MS and GC-MS methods will be helpful to improve quality control of Asarum sieboldii.

Analysis of Agrochemical Residues in Tobacco Using QuEChERS Method by GC-MS/MS

  • Lee, Jeong-Min;Jang, Gi-Chul;Hwang, Keon-Joong
    • 한국연초학회지
    • /
    • 제29권2호
    • /
    • pp.132-139
    • /
    • 2007
  • This study was performed to apply the more rapid and accurate sample preparation, and the high selectivity and sensitivity of the analyte detection by gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS). QuEChERS (quick, easy, cheap, effective, rugged and safe) method was validated for 49 agrochemicals in the CORESTA Agrochemical Advisory Committee guide and amenable to GC-MS/MS determination. In QuEChERS method, the effects of sorbents (PSA, $C_{18}$ and GCB) and matrix of the analytes in tobacco types (flue-cured, burley and oriental) were investigated. MS/MS acquisition provided high specificity and selectivity for agrochemicals and low limit of quantification. QuEChERS by using PSA alone and the matrix-matched standards gave good recoveries and RSD values in three types of tobaccos. QuEChERS method was no needed to be complex clean-up procedure and would be used as the fast and easy method for agrochemical residue analysis in tobacco.

생약 중 잔류 농약의 분석법: GC/MS에 의한 27종 잔류 규제 농약의 분석 (Analysis of Residual Pesticides in Herbal Drugs: GC/MS Analysis of 27 Controlled Pesticides)

  • 박만기;박정일;윤혜란;윤인병;조술연;황귀서
    • 약학회지
    • /
    • 제40권2호
    • /
    • pp.141-148
    • /
    • 1996
  • GC/MS analysis of 27 controlled pesticides in herbal drugs was studied. Selected ion monitoring(sim) technique was applied to increase the GC/MS sensitivity. Typical peaks in th e mass spectrum of each pesticides were selected as quantitation, comfirmation or alternate ion. Twenty seven pesticides were divided into five groups according to their retention time and the peaks for SIM were programmed accordingly. The combination of two ionization methods, electron impact(EI)-SIM-MS and negative ion chemical ionization(NCI)-SIM-MS, were well-fitted for the detection, confirmation and quantitation of multiclass residual pesticides in herbal drugs.

  • PDF

GC/FID와 GC/MS 분석법에 의한 목질제품에서의 VOC 방출특성 비교 (The Comparison of VOC Characteristics Emitted from Wood-based Panels Using GC/FID and GC/MS)

  • 황윤서;박현주;손윤석;김조천
    • 한국대기환경학회지
    • /
    • 제27권4호
    • /
    • pp.436-442
    • /
    • 2011
  • In this study, the Total Volatile Organic Compounds (TVOC) emitted from wood-based panels were compared by two analytical methods using the GC/FID and the GC/MS. Japanese Larch, Yellow Poplar, Particle Board (PB) and Medium Density Fiberboard (MDF) were selected as target materials. Major compounds emitted from the panels were Toluene, ${\alpha}$-pinene, ${\beta}$-pinene and limonene. In case of TVOC using GC/FID method, MDF E2 (1,497 ${\mu}g/m^3$) revealed the highest concentration among all wood-based panels, while Japanese Larch (1,772 ${\mu}g/m^3$) showed the highest value with respect to GC/MS method. Furthermore, it was found that the amount of VOC emitted from panels was different depending upon analytical methods. This significant difference was attributed to analytical sensitivities of GC/FID and GC/MS for various VOC. Besides, it was found that the composition ratios of main VOC compounds were not significantly different.

GC/MS와 GC/ECD를 이용한 한약재 중 잔류 농약의 분석 (GC/MS and GC/ECD Analysis of Residual Pesticides in Herbal drugs)

  • 김호경;박소연;고병섭
    • 대한한의학회지
    • /
    • 제20권1호
    • /
    • pp.44-51
    • /
    • 1999
  • Analysis of residual pesticides in herbal drugs was performed by GC-ECD and GC-MS. Especially, selected ion monitoring(SIM) technique was applied to increase the GC/MS sensitivity. Analysis of residual pesticides was determined sensitivity and selectively without any internal standard by setting the SIM technique to their characteristic fragments for quantitation ion and confirmation ion. The combination of two detector, GC-ECD and MS-SIM technique, is abailable for determining a multiclass residual pesticides in herbal drugs. The average recoveries through the method were $65.9%{\sim}99.7%$ in herbal drugs. The data of gas chromatographic analysis was compared with the limits of residual pesticides in herbal drugs and agricultural foods. 4. 4-DDT was detected above the limits to the residual pesticides in herbal drugs. Diazinon and EPN were detected, but the limits of residual pesticides were less than that of agricultural foods.

  • PDF

GC/MS를 이용한 소변중의 Cyclofenil 및 그 대사체의 분석 (Analysis of Cyclofenil and its Metabolites in Human Urine using GC/MS)

  • 명승운;민혜기;조현우;김동현;김명수
    • 분석과학
    • /
    • 제15권3호
    • /
    • pp.185-189
    • /
    • 2002
  • Cyclofenil은 국제올림픽위원회(IOC)에서 금지약물로 규정하고 있다. 이에 따라 본 실험에서는 GC/MS를 사용하여 소변으로부터 cyclofenil의 복용여부를 검사할 수 있는 방법을 만들었다. 이를 위하여 cyclofenil 및 그 대사체들의 추출 회수율을 측정하였는데 pH 5-9 사이가 최적의 추출 조건이었으며, 소변으로는 모 약물인 cyclofenil은 배설되지 않아서 검출하지 못하였고 대신에 그 대사체들을 검출함으로써 cyclofenil의 복용여부를 검출할 수 있었다. 따라서 대사체들은 가수분해 후 pH 9.6에서 에테르로 추출하여 MSTFA로 유도체화시켜서 GC/MS로 분석하였다.

TDU-GC/MS를 이용한 한국품종 참당귀 국산 판별 기법 (Geographical origin discrimination of Korean variety, Angelica gigas Nakai by using TDU (Thermal Desorption Unit)-GC/MS)

  • 이미나;김윤석;김원일;김정규;권오경
    • Journal of Applied Biological Chemistry
    • /
    • 제63권1호
    • /
    • pp.29-33
    • /
    • 2020
  • 한약재의 불법 유통을 방지하기 위해 신속 정확한 원산지 판별방법 개발이 필요함에 따라 TDU-GC/MS를 이용하여 한국품종 당귀와 외국품종 당귀를 판별함과 동시에 한국품종 당귀의 재배지가 한국인지를 판별할 수 있는 기법을 연구하였다. 당귀추출물을 열탈착 시킨 후 냉각응축시스템에서 응축시켜 일시에 GC/MS로 분석한 결과 국산 품종 당귀(참당귀)는 TIC의 RT 26.9-27.2에서 coumarin 유도체인 decursin과 decursinol peak가 확인되었다. 중국 품종 당귀(중당귀)의 경우 RT 17.2 부근에서 ligustilide의 peak가 검출되었다. 국산 품종 참당귀 원산지에 따른 휘발성분의 차이를 알아보기 위하여 twister로 흡착하여 TDU-GC/MS로 m/z 40-400 amu 범위에서 mass spectrum을 측정하였다. 참당귀의 국내 및 중국 재배 시료 TIC는 전반적으로 같은 경향을 냈으나 TIC를 부분 scan한 결과 RT 15.4-16.1에서 국내 및 중국 재배의 peak pattern 차이를 확인할 수 있었다. Peak A (RT 15.54)과 B (RT 16.05)의 비율은 국내 재배는 0.0-0.2, 중국 재배의 경우 0.5-2.8으로서 TDU-GC/MS의 TIC peak pattern 비교를 통한 원산지 판별 가능성을 확인하였다.

교반막대 추출법과 GC-MS/MS를 이용한 수중의 합성 향물질류 분석 (Analysis of Synthetic Fragrances (SFs) in Water Using Stir Bar Sorptive Extraction (SBSE) and GC-MS/MS)

  • 서창동;손희종;염훈식;최진택;류동춘;권기원;장성호
    • 대한환경공학회지
    • /
    • 제36권6호
    • /
    • pp.387-395
    • /
    • 2014
  • 본 연구에서는 SBSE 전처리 장치와 GC-MS/MS를 이용하여 합성 향물질 11종을 동시 분석할 수 있는 분석법을 개발하기 위해 흡착 bar의 교반시간, 교반속도, 시료수의 pH, 시료수 용량, 염석제 투입량 및 메탄올 주입량 변화 등 SBSE (stir bar sorptive extraction) 전처리 조건과 GC-MS/MS (gas chromatography/tandem mass spectrometry)의 기기조건을 다양하게 변화시켜 SBSE-GC-MS/MS를 이용한 분석법을 개발하였다. 11종의 합성 향물질들에 대한 검출한계(LOD)는 2.1~4.1 ng/L였으며, 정량한계(LOQ)는 6.6~12.9 ng/L였다. 수돗물, 낙동강 원수, 하수처리장 최종방류수 및 해수를 이용하여 시료수의 matrix 영향을 살펴본 결과, 11종의 합성 향물질들의 회수율 및 RSD의 경우 각각 88%~119% 및 0.8%~7.5%로 양호한 결과를 나타내어 시료수의 matrix 영향을 받지 않는 것으로 나타났다. 본 연구에서 개발된 SBSE-GC-MS/MS 분석법은 40 mL 정도의 적은 시료수량으로도 고감도 분석이 가능하며, 용매류를 사용하지 않기 때문에 분석자의 건강 및 환경친화적인 분석법이라는 장점뿐만 아니라 간편하고, 빠르며 자동화된 방법이라는 장점을 가진다.