• 제목/요약/키워드: GC-${\mu}ECD$

Search Result 40, Processing Time 0.02 seconds

Applicability of Using GC-PDD (Pulsed Discharge Detector) for Multiresidual Pesticides Analysis

  • Oh, Chang-Hwan
    • Food Science and Biotechnology
    • /
    • v.15 no.6
    • /
    • pp.959-966
    • /
    • 2006
  • The electron-capture detector (ECD) of gas chromatographs (GC) has been used widely in pesticide analysis. However, as ECD relies on radioactive material, it is troublesome to purchase and maintain. Therefore, potent replacements for ECD were investigated. A Pulsed-discharge detector (PDD) for ECD was tested and the analytical results of PDD (ECD mode), ${\mu}ECD$, and nitrogen-phosphorus detector (NPD) were compared for 107 pesticides including organochroline, organophosphorus, pyrethroids etc. The number of pesticides identified at the lowest limit of detection (LOD) was 36, 29, and 2 for PDD, ${\mu}ECD$, and NPD, respectively. The remaining pesticides showed same response to PDD and ${\mu}ECD$. The GC-PDD analysis of pesticides spiked into representative agricultural products (brown rice, spinach, and mandarin oranges) also showed good and/or equivalent recoveries using $GC-{\mu}ECD$.

Analytical method of the polychlorinated biphenyls in soil using GC/ECD and GC/MS (GC/ECD 및 GC/MS을 이용한 토양 중 PCBs 분석방법 고찰)

  • Kim, Tae-Seung;Shin, Sun-Kyoung;Yoon, Jeong-Ki;Kim, Jong-Ha;Kim, Hyoung Seop;Lee, Jeong Ah
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.91-108
    • /
    • 2007
  • This study was investigated both the Korean official soil test method and the international various methods for PCBs in soil sample. The analytical guideline of PCBs in contaminated soil were proposed based on the official soil test methods by discussing the extraction, column cleanup, instrumental conditions, quantification methods of peak matching and individual isomers. The total 28 soil samples were selected by consideration of PCBs-contamination, land use etc., and then analyzed using gas chromatography/electron capture detection (GC/ECD) and gas chromatography/mass spectrometry(GC/MS). In this study, the PCBs were not detected as peak matching method using GC/ECD, but PCBs detected $0.002{\sim}0.487{\mu}g/kg$ using GC/MS in background concentrations.

Multi-residue Analysis of Pesticides using GC-TOF/MS, ECD, NPD with QuEChERS Sample Preparation (QuEChERS 전처리법과 GC-TOF/MS, ECD, NPD를 이용한 잔류농약 다성분분석)

  • Park, Jungwook;Kim, Aekyung;Kim, Jongpil;Lee, Hyanghee;Park, Duckwoong;Moon, Sujin;Ha, Dongryong;Kim, Eunsun;Seo, Kyewon
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.278-295
    • /
    • 2014
  • Fast and accurate multi-residue pesticides inspecting method needs in Agro-Fishery Products Inspection Center. So, We tried to seek the optimum method using GC-TOF/MS, GC-ECD, GC-NPD after QuEChERS sample preparation. In GC-TOF/MS, 138 kinds of pesticide were spiked at 0.3 and $0.5{\mu}g/g$for the identification and quantification in lettuce sample. Recoveries of 77 pesticides were between 70 and 130% with RSD (relative standard deviation lower than 20% at $0.3{\mu}g/g$. In GC-ECD, NPD, 146 kinds of pesticide were spiked for the identification and quantification in lettuce. Recoveries of 61 species were between 70 and 130% with lower than 20%. These results indicated that GC-TOF/MS, GC-ECD, NPD analysis with the QuEChERS sample preparation can be partly applied to multi-residue pesticides in vegetables.

Determination of the Homocysteine, Cysteine and Methionine in Human Plasma by Gas Chromatography with Electron Capture Detector (기체크로마토그래피-전자포획검출기를 이용한 혈장 중의 Homocysteine, Cysteine 및 Methionine의 동시 분석법)

  • Myung, Seung-Woon;Chang, Yoon-Jung;Yoo, Eun-Ah;Park, Joon-Ho;Min, Hye-Ki;Kim, Myung-Soo
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.408-414
    • /
    • 1999
  • A selective and sensitive method for the derivatization of total homocysteine (Hcy) and the related compounds in plasma by gas chromatograph (GC)-electron capture detector (ECD) has been developed. To determine total homocysteine, cysteine (Cys), and methionine (Met) in human plasma using GC-ECD, analytes were reduced and converted into their N(O,S)-ethylearbonyl pentafluoropropyl (PFP) ester by derivatization with ethyl chloroformate and pentafluoropropyl alcohol (PFP-OH) in plasma. The best derivatizing agent N(O,S)-ethyl carbonyl PFP ester, was chosen by comparing the sensitivity of derivatized analysis in GC-ECD. The derivatized analytes in plasma were extracted by chloroform, and subsequently back-extracted with hexane and analyzed by GC-ECD. The calibration carves ($R^2$ > 0.990) were linear over the range $5-50{\mu}mol/L$ of Hcy and Met, $40-400{\mu}mol/L$ of Cys spiked in plasma. The detection limit observed by the established method was below $0.5{\mu}mol/L$. This method is highly sensitive and specific in the analysis of Hcy, Cys, and Met. Therefore, we suggest that this method is appropriate in the analysis of trace concentration of Hcy, Cys, and Met in biological fluids.

  • PDF

Finite Element Analysis on the Strength Safety of a Fuel Tank for Highly Compressed Gas Vehicle (수술실 내의 아산화질소($N_2O$) 노출평가)

  • Baek, Jong-Bae;Uhm, Min-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.34-38
    • /
    • 2009
  • Nitrous oxide, which is used as an anesthetic gas, has been shown to be a chronic health hazard. It is necessary to monitor and control the nitrous oxide exposure of the operating theaters staff. In this study, N2O exposure level of the operating nurses is assessed with a GC-ECD. The nitrous oxide gas is collected on a molecular sieve 5A contained in a glass tube and desorbed for 12 hours at $100^{\circ}C$ in heating block. As a result of the test using GC-ECD, calibration curve's $R^2$ of $N_2O$ is 0.9992, LOD is $0.96{\mu}g$/injection, LOQ is $3.21{\mu}g$/injection, desorption efficiency is 94.78 4.50% in average and break through is within 10% compared with the concentration. The average concentration before operation is 5.12ppm and it is 42.3ppm during operation. There are a significant difference showing that the P value is lower than 0.05. Assessing exposure level to nitrous oxide based on nurses' working positions, the exposure levels do not show significant difference( P>0.005). And $N_2O$ in active sampling method is higher than passive sampling method(P<0.05).

  • PDF

Simultaneous Analytical Method of Organochlorine and Pyrethroid Pesticides using GC(ECD) (GC-ECD를 이용한 유기염소계 밑 Pyrethroid계 농약 동시 분석법)

  • 김우성;이선화;김재이;정지윤;이명자;박영채;이영자;정성욱;이봉헌
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.477-480
    • /
    • 2003
  • Pesticides were extracted from samples with 70% acetone and methylene chloride in order, and then cleaned up via open-column chromatography apparatus packed with florisil, and finally analyzed simultaneously the organochlorine and pyrethroid pesticides using GC(ECD). An ultra-2 fused silica capillary column was used to separate and identify the products. The resolution between the last isomeric peak of cypermethrin(59.987min) and the first isomeric peak of flucythrinate(60.043min) was not satisfactory. The last isomeric peak of fenvalerate(62.344min) and the first isomeric peak of fluvalinate(62.397min) were overlapped. Recoveries of soybean sample fer the most pesticides were 73.3% to 102.4%. Detection limits were between 0.004 and 0.063 ${\mu}$g/mg when this method was used.

Derivatization and Residual Determination of MCPP in Soil Leachate (토양 침투수중 MCPP의 유도체화 및 잔류분석)

  • Hong, Moo-Ki;Smith, Albert E.
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.199-208
    • /
    • 1994
  • Analytical methods for the determination of the derivatives of the herbicide (${\pm}$)-2-(4-chloro-2-methylphenoxy)propionic acid (MCPP) by capillary column gas chromatography with mass spectrometer (GC-MS) and electron-capture detection (GC-ECD) were studied. A successful procedure was introduced for the ester preparation using $H_2SO_4$, as the catalyst and the alcohol 2,2,2-trichloroethanol (TCE) or 2,2,2-trifluoroethanol (TFE). The identificaiton and elucidation of MCPP by GC-MS spectrometry following the esterification with diazomethane, $BF_3$/methanol, $H_2SO_4$/methanol, TCE, TFE, or pentafluorobenzyl bromide (PFB) were carried out. A comparison of the response-sensitivities among those MCPP esters was made with GC-ECD. Although the methylation product of MCPP was confirmed by GC-MS, its low sensitivity to the ECD limited the detection of MCPP. TCE, TFE, and PFB derivatization methods resulted in a high rate of MCPP esterifications and very sensitive ECD molecular responses. Based on efficiency, convenience, worker safety, and least sample contamination, TFE esterificaiton was considered as the superior method for MCPP analysis to the other methods of derivatization. An accurate method is described for quantifying MCPP in soil leachates by GC-ECD at very low concentrations without the requirement of a complicated clean-up process. As a result, MCPP residues at concentrations of less than $0.1{\mu}g$ in 100ml soil leachate were detected.

  • PDF

Screening procedure for organochlorinated pesticide residues in meat fat using a matrix solid phase dispersion(MSPD) extraction and GC/ECD (MSPD법과 GC/ECD를 이용한 식육중의 잔류농약 분석)

  • 백미순;이영철;박병옥;김창수;박유순
    • Korean Journal of Veterinary Service
    • /
    • v.22 no.1
    • /
    • pp.15-23
    • /
    • 1999
  • A multiresidue, simple and rapid isolation technique known as matrix-solid phase dispersoin (MSPD) for the extraction and quantitative gas chromatographic/electron capture detection (GC/ECD) determination of 14 organochlorinated pesticides($\alpha$-BHC, ($\beta$-BHC, ($\gamma$-BHC, aldrin, dieldrin, endrin, heptachlor, ($\alpha$-endosulfan, ($\beta$-endosulfan, endosulfan sulfate, p,p'-DDE, o,p'-DDD, p,p'-DDD, p,p'-DDT) from meat fats. The 14 pesticide were fortified into meat fat(0.5g) and blend with 2g $C_{18}$, $C_{18}$meat fat matrix blend and 2g activated florisil comprise an extraction column from which the pesticides are eluted by adding 8ml acetonitrile. Then 2${\mu}\ell$ of the eluate is analyzed by GC/ECD. Unfortified blank controls are tested similarly. The eluate contained all the pesticide analytes and was free of interfering coextractants. Recovery rate(31.3-500ng/g) were ranged from 80$\pm$4% to 97$\pm$4%. Any organochlorinated pesticides were not detected in 120 samples of beef and pork collected from slaughter houses in Kyeonggi province.

  • PDF

PCBs concentration and congener distribution in transformer insulation oil samples using GC/ECD and HRGC/HRMS analysis (GC/ECD와 HRGC/HRMS 분석을 이용한 변압기 절연유 중 PCBs 농도 및 이성체 분포)

  • Kim, Kyoung-Soo;Kim, Hyoung-Seop;Song, Byung-Joo;Jeong, Mi-Jeong;Kim, Jong-Guk;Park, Seok-Un;Shin, Sun-Kyoung
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.232-240
    • /
    • 2005
  • The total PCBs level in the transformer insulation oil samples using GC/ECD and HRGC/HRMS were ranged from 0.087 to $223.6{\mu}g/g$ and ranged from N.D. to $154.04{\mu}g/g$, respectively. The calculated TEQ values were ranged from 0.00067 to 6.8 ng WHO-TEQ/g. Among the samples, 6 samples showed higher than 2 ppm concentration (specific waste criterion of Korea). A variety in the concentration of total PCBs were observed between ECD and HRMS analysis. This is maybe due to quantification mehtod. The Aroclor 1248 wasn't present in the samples. The distribution pattern of Co-PCB congeners showed that the ratio of monoortho substituted congeners were higher than non-ortho substituted congeners. Among that, PCB-167 congener was predominant. In addition, the distribution of Co-PCBs congeners was different with that of flue gas and ambient air samples as well as commercial PCB formulations (Aroclor, Kanechlor).

폐기물 매립지 토양에서의 PCBs 분석법

  • Lee Jeong-Hwa;Jeon Chi-Wan;Jeong Yeong-Uk
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.199-201
    • /
    • 2005
  • This paper describes a simple procedure for the quantitative analysis of 7 PCBs (polychlorinated biphenyls) in soils on the waste reclaimed land, The procedure involved sample clean up using silicagel column, acetonitrile partition and sulfuric acid procedures. The instrumental technique is applied GC/PDD(gas chromatography/pulsed discharge detector) and GC/ECD(gas chromatography/electron capture detector). Concentration of $sub-{\mu}g/g$ level was attainable with 20g soils on the waste reclaimed land.

  • PDF