• 제목/요약/키워드: GC/MS spectrometry

검색결과 749건 처리시간 0.022초

Mass Spectrometry-Based Metabolite Profiling and Bacterial Diversity Characterization of Korean Traditional Meju During Fermentation

  • Lee, Su Yun;Kim, Hyang Yeon;Lee, Sarah;Lee, Jung Min;Muthaiya, Maria John;Kim, Beom Seok;Oh, Ji Young;Song, Chi Kwang;Jeon, Eun Jung;Ryu, Hyung Seok;Lee, Choong Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권11호
    • /
    • pp.1523-1531
    • /
    • 2012
  • The metabolite profile of meju during fermentation was analyzed using mass spectrometry techniques, including GC-MS and LC-MS, and the bacterial diversity was characterized. The relative proportions of bacterial strains indicated that lactic acid bacteria, such as Enterococcus faecium and Leuconostoc lactis, were the dominant species. In partial least-squares discriminate analysis (PLS-DA), the componential changes, which depended on fermentation, proceeded gradually in both the GC-MS and LC-MS data sets. During fermentation, lactic acid, amino acids, monosaccharides, sugar alcohols, and isoflavonoid aglycones (daidzein and genistein) increased, whereas citric acid, glucosides, and disaccharides decreased. MS-based metabolite profiling and bacterial diversity characterization of meju demonstrated the changes in metabolites according to the fermentation period and provided a better understanding of the correlation between metabolites and bacterial diversity.

GC/MS에 의한 오미자 Lignan성분의 동정 (Identification of Lignan Compounds in Fruits of Schisandra chinensis BAILLON by Gas Chromatography/Mass Spectrometry)

  • 손현주;복진영
    • Applied Biological Chemistry
    • /
    • 제32권4호
    • /
    • pp.344-349
    • /
    • 1989
  • GC/MS를 이용하여 오미자의 chloroform-methanol 추출물로부터 11종의 lignan 성분을 동정하였다. GC column은 SPB-1 fused silica capillary $(0.25mm\;ID{\times}30m,\;Supelco)$를 사용하였고 column oven의 온도는 $200^{\circ}C$부터 $300^{\circ}C$까지 분당 $4^{\circ}C$씩 승온하였으며 MS의 ionization voltage는 70eV (El mode)이었다. 동정된 lignan 성분은 gomisin J, deoxyschizandrin, gomisin N, schizandrin, wuweizisu C, gomisin A, angeloylgomisin H, tigloylgomisin H, angeloylgomisin Q, gomisin B 및 benzoylgomisin H이었으며, GC chromatogram 상에서 이들 화합물의 분리상태는 양호하였다.

  • PDF

Identification of Coffee Fragrances Using Needle Trap Device-Gas Chromatograph/Mass Spectrometry (NTD-GC/MS)

  • Eom, In-Yong;Jung, Min-Ji
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1703-1707
    • /
    • 2013
  • A fast and simple sampling and sample preparation device, (NTD) has been developed and applied to sample and analyze volatile components from ground coffee beans. Coffee fragrances and other volatile organic compounds (VOCs) were sampled by the NTD and then analyzed by gas chromatograph-mass spectrometry (GC/MS). Divinylbenzene (DVB) particles (80/100 mesh size) were the sorbent bed of the NTD. More than 150 volatile components were first identified based on the database of the mass library and then finally 30 fragrances including caffeine were further confirmed by comparing experimental retention indices (i.e. Kovat index) with literature retention indices. Total sampling time was 10 minutes and no extra solvent extraction and/or reconstitution step need. Straight n-alkanes (C6-C20) were used as retention index probes for the calculation of experimental retention indices. In addition, this report suggests that an empty needle can be an alternative platform for analyzing polymers by pyrolysis-GC/MS.

Determination of panthenol, cholecalciferol and tocopherol in cosmetic products by gas chromatography-mass spectrometry in SIM mode

  • Hye-Jin Jeong;Myo
    • 대한화장품학회지
    • /
    • 제22권2호
    • /
    • pp.153-160
    • /
    • 1996
  • A novel simple method to detect vitamins in cosmetic products by gas chromatography-mass spectrometry(GC-MS) has been developed. Three vitamins(panthenol, cholecalciferol and tocopherol) were used for this study. Vitamins were prepared by dissolving in tetrahydrofuran(THF), and silylated with bis-trimethylsilyltrifluoroacetamide-trichloromethylsilane(BSTFA). Silated vitamins were separated on a fuses-silica capillary column coated with DB-5. The identification of each vitamin was accomplished by retention time and mass spectrum library search with a computer, and the quantitation was made in the selected-ion monitoring(SIM) mode of GC-MS. SIM mode had given sensitivity to determine 50pg of panthenol, 285pg of cholecalciferol and 130pg of tocopherol. Linearity was maintained over the range 0.005-0.20% for each vitamin. Each cosmetic product(i.e. hair tonic and lotion) was found to contain amounts of the vitamins. This method was sensitive and gave 77.5-99.9% recovery of each vitamin from these cosmetic products. From these results, we concluded that silylation with BSTFA followed by GC-MS analysis allows the simple, covenient and exact determination of panthenol, cholecalciferol and tocopherol.

  • PDF

GC/MS를 이용한 모발 중 MDMA(Methylendedioxymethamphetamine)의 분석 (Analysis of 3,4-Methylendedioxymethamphetamine (MDMA) in Human Hair by Gas Chromatography/Mass Spectrometry)

  • 박미정;김은미;임미애;정희선
    • 약학회지
    • /
    • 제47권4호
    • /
    • pp.195-199
    • /
    • 2003
  • An analysis method for the determination of methylendedioxymethamphetamine (MDMA) and its metabolite methylendedioxymethamphetamine (MDA) in hair by gas chromatography/mass spectrometry was proposed. For MDMA and MDA analysis, hair samples were incubated in MeOH (1% HCl), derivatized with trifluoroacetic anhydride and assayed by GC/MS. Hair of 18 subjects for drug abuse was analyzed for MDMA and MDA. Calibration curves for the determination of MDMA and MDA in hair showed a good linearity at a concentration range from 0.5 ng to 250 ng ($r^2$=0.999) The extraction recovery was determined from hair blanks at 50, 100 ng. The percentage of recovery were found to be 96.08∼103.48 with CV value of 1.62∼3.89. The concentrations of MDMA and MDA ranged 1.14∼38.06 ng/mg and 0.07∼3.91 ng/mg, respectively in 18 hair samples from MDMA abusers. The ratio of MDMA to MDA ranged from 9.65∼28.46 in all specimen. Hair analysis for MDMA is a useful method for identification of long-term drug abuser.

Headspace-Solid Phase Microextraction (HS-SPME) Analysis of Korean Fermented Soybean Pastes

  • Lee, Seung-Joo
    • Food Science and Biotechnology
    • /
    • 제18권3호
    • /
    • pp.700-705
    • /
    • 2009
  • In this study, the volatile compounds in 9 commercial fermented soybean pastes were extracted and analyzed by headspace-solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS), respectively. A total of 63 volatile components, including 21 esters, 7 alcohols, 7 acids, 8 pyrazines, 5 volatile phenols, 3 ketones, 6 aldehydes, and 6 miscellaneous compounds, were identified. Esters, acids, and pyrazines were the largest groups among the quantified volatiles. About 50% of the total quantified volatile material was contributed by 5 compounds in 9 soybean paste samples; ethyl hexadecanoate, acetic acid, butanoic acid, 2/3-methyl butanoic acid, and tetramethyl-pyrazine. Three samples (CJW, SIN, and HAE) made by Aspergillus oryzae inoculation showed similar volatile patterns as shown in principal component analyses to GC-MS data sets, which showed higher levels in ethyl esters and 2-methoxy-4-vinylphenol. Traditional fermented soybean pastes showed overall higher levels in pyrazines and acids contents.

Screening of Nitrosamine Impurities in Sartan Pharmaceuticals by GC-MS/MS

  • Chang, Shu-Han;Ho, Hui-Yu;Zang, Chi-Zong;Hsu, Ya-Hui;Lin, Mei-Chih;Tseng, Su-Hsiang;Wang, Der-Yuan
    • Mass Spectrometry Letters
    • /
    • 제12권2호
    • /
    • pp.31-40
    • /
    • 2021
  • Probable human carcinogenic compounds nitrosamines, have been detected as by-product impurities in sartan pharmaceuticals in recent years which has drawn worries for medication safety. To provide a sensitive and effective method for the quality control of sartan pharmaceuticals, this study established a feasible gas chromatography-tandem mass spectrometry (GC-MS/MS) method for simultaneous determination of 13 nitrosamines. The target analytes were separated on a DB-WAX Ultra Inert column (30 m × 0.25 mm; i.d., 0.25 ㎛) and were then subjected to electron impact ionization in multiple reaction monitoring mode. The established method was validated and further employed to analyze authentic samples. Limits of detection (LODs) and limits of quantification (LOQs) of the 13 nitrosamines were 15-250 ng/g and 50-250 ng/g, respectively, which also exhibited intra-day and inter-day accuracies of 91.4-104.8%, thereby satisfying validation criteria. Five nitrosamines, viz., N-nitrosodiethylamine, N-nitrosodimethylamine, N-nitrosodiphenylamine, N-nitrosomorpholine, and N-nitrosopiperidine were detected at concentrations above their LODs in 68 positive samples out of 594 authentic samples from seven sartans.

Quality Assessment of Curcuma longa L. by Gas Chromatography-Mass Spectrometry Fingerprint, Principle Components Analysis and Hierarchical Clustering Analysis

  • Li, Ming;Zhou, Xin;Zhao, Yang;Wang, Dao-Ping;Hu, Xiao-Na
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권10호
    • /
    • pp.2287-2293
    • /
    • 2009
  • Gas Chromatography-Mass Spectrometry (GC-MS) fingerprint analysis, Principle Components Analysis (PCA), and Hierarchical Cluster Analysis (HCA) were introduced for quality assessment of Curcuma longa L. (C. longa). The GC-MS fingerprint method was developed and validated by analyzing 33 batches of samples of C. longa from different geographic locations. 18 chromatographic peaks were selected as characteristic peaks and their relative peak areas (RPA) were calculated for quantitative expression. Two principal components (PCs) were extracted by PCA. C. longa collected from Guizhou and Fujian were separated from other samples by PC1, capturing 71.83% of variance. While, PC2 contributed for their further separation, capturing 11.13% of variance. HCA confirmed the result of PCA analysis. Therefore, GC-MS fingerprint study with chemometric techniques provides a very flexible and reliable method for quality assessment of C. longa.

Diagnostic Evaluation of Enzyme Activity Related to Steroid Metabolism by Mass Spectrometry-Based Steroid Profiling

  • Choi, Man Ho;Chung, Bong Chul
    • Mass Spectrometry Letters
    • /
    • 제5권2호
    • /
    • pp.35-41
    • /
    • 2014
  • Gas chromatography-mass spectrometry (GC-MS) methods have been used extensively in clinical steroid analyses. Evaluating the metabolic ratios of precursors to products by accurate quantification of individual steroid levels in biological samples can reveal the activities of enzymes associated with steroid metabolism. This review article discusses the impact of GC-MS-based steroid profiling on our understanding of the biochemical role of steroids and their metabolic enzymes in hormone-dependent diseases, such as congenital adrenal hyperplasia (CAH), cortisol-mediated hypertension, apparent mineralocorticoid excess (AME), male-pattern baldness, and breast and thyroid cancers. Steroid profiling is a comprehensive analytical technique that can be applied whenever the highest specificity is required and may be a reasonable initial diagnostic approach.

Gas Chromatography/Mass Spectrometry를 이용한 팔강약침액 성분에 대한 연구 (The Study on the Composition in Pharmacopunctures of Eight Principles by Gas Chromatography/Mass Spectrometry)

  • 김협;안병수
    • 대한약침학회지
    • /
    • 제11권3호
    • /
    • pp.79-91
    • /
    • 2008
  • Objective: The purpose of this study was to investigate the composition for pharmacopunctures of eight principles hydrodistillation layer. Methods: The study was determined the hydrodistillation layer for pharmacopunctures of eight principles by hydrodistillation method. The effective components in hydrodistillation layer for pharmacopunctures of eight principles were extracted with ethyl ether or dichloromethane, and then analyzed by Gas Chromatography/Mass Spectrometry(GC/MS). Results: 1. Analyzed pharmacopunctures of eight principles by GC/MS, a lot of differences according to extraction solvent by each pharmacopunctures of eight principles and specific peak patterns were seen. 2. The main compound in pharmacopunctures of eight principles was a kind of hexaoxacyclohydrocarbon that has long hydrocarbon chain.