• Title/Summary/Keyword: GC(Gas Chromatography)

Search Result 1,281, Processing Time 0.03 seconds

Analysis of Mint Essential Oils from Jeju Island, Korea by Gas Chromatography-mass Spectrometry and Headspace-Gas Chromatography-mass Spectrometry (Gas Chromatography-mass Spectrometry와 Headspace-Gas Chromatography-mass Spectrometry를 이용한 제주산 민트 에센셜오일 성분 분석)

  • Hyun, Ho Bong;Boo, Kyung Hwan;Kang, Hye Rim;Kim Cho, Somi
    • Journal of Applied Biological Chemistry
    • /
    • v.58 no.2
    • /
    • pp.175-181
    • /
    • 2015
  • Compositions of essential oils extracted from mint herb such as Mentha piperita, Mentha spicata, and Mentha ${\times}$ piperita var. citrate produced in Jeju were analyzed using gas chromatography-mass spectrometry (GC-MS) and headspace-GC-MS (HS-GC-MS). By the GC-MS analysis, 13 compounds were tentatively identified in Mentha piperita, Mentha spicata, and Mentha ${\times}$ piperita var. citrate, respectively. Peperitenone oxide, carvone, and linalool were detected as major compounds in Mentha piperita, in Mentha spicata, in Mentha ${\times}$ piperita var. citrate, respectively, based on the ratio of peak intensity in the total ion chromatogram. The greater number of compounds, including volatile alcohols and acetates were identified by HS-GC-MsS than by GC-MS in these all three essential oils. Similar patterns of composition were detected in both Mentha spicata and Mentha ${\times}$ piperita var. citrate by either one of GC-MS methods. However, in case of Mentha piperita, $\small{L}$-(-)-menthol, which was identified as the major compound by HS-GC-MS was detected in dramatically reduced quantity by GC-MS. Interestingly, we found that both linalyl acetate and linalool were identified as the dominant compounds in the essential oil of Mentha ${\times}$ piperita var. citrate.

Simultaneous Gas Chromatographic Analysis of Ethanol and Acetic Acid in Vinegar (식초의 에탄올 및 초산 함량의 동시분석)

  • Yoon, Hee-Nam
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.1247-1251
    • /
    • 1998
  • A method is developed for simultaneously determining ethanol and acetic acid in vinegars by quantitative packed-column gas chromatography. Vinegars were filtrated and directly chromatographed on a $2\;m{\times}2\;mm$ stainless steel column packed with Tenax-GC, 80/100. Ethanol, isopropy alcohol as an internal standard, and acetic acid were completely separated within 20 min of running time without any interfering peaks. The accuracy of packed column gas solid chromatography (PCGSC) was discussed compared to the analytical data by titration, high performance liquid chromatography and capillary column gas liquid chromatography (CCGLC).

  • PDF

Determination of $\beta$-Lactam Antibiotics by Gas Chromatography with Flame Photometric Detector (I) (GC/FPD를 이용한 $\beta$-락탐계 항생물질의 분석(I))

  • 박만기;조영현;양정선
    • YAKHAK HOEJI
    • /
    • v.28 no.1
    • /
    • pp.25-27
    • /
    • 1984
  • Some $\betha$-lactam antibiotics-penicillins and cephalosporins-were determined by gas chromatography (GC) with flame photometric detector (FPD) which was selective and sensitive to sulfur-containing compounds. Methyl ester derivatives of carboxyl group in $\betha$-lactam antibiotics were prepared using 0.5Mmethyl iodide in methylene chloride and were taken for gas chromatography with 0.9% or 0.6% QF-1 on Chromosorb WAW-DMCS. We have found that it is possible to determine methyl esters of $\betha$-lactam antibiotics by GC/FPD.

  • PDF

Analytical method for analyzing formaldehyde using 2, 4-DNPH and gas chromatography/FID, NPD (2,4-DNPH와 가스크로마토그래프를 이용한 포름알데히드 분석방법)

  • Jeong, Jee Yeon;Park, Seung Hyun;Yi, Gwang Yong;Oh, Se Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.126-146
    • /
    • 2000
  • To develop and evaluate formaldehyde measurement method using 2,4-dinitro-phenylhydrazine (2,4-DNPH) coated sampler and gas chromatography, laboratory test and field test were conducted. Results of this study are as follows. Limit of detection(LOD) of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is $0.008{\mu}g/m{\ell}$ $0.060{\mu}g/m{\ell}$, $0.472{\mu}g/m{\ell}$ respectively. Coefficiency of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is 0.008, 0.009, 0.020 respectively. Desorption efficiency of sep-pak xposure aldehyde sampler and sorbent sample tube is 1.05(range : 0.99 - 1.12), 1.02(range : 0.99 - 1.06) respectively. Samples of sorbent sample tube and sep-pak xposure aldehyde sampler turned out to be stored at refrigerator, according to storage test results. Measurement methods of HPLC-UVD, GC-NPD, GC-FID, according to results of precision for the combined sampling and analytical procedure, became acceptable to OSHA evaluation standard. Field test using exposure chamber met the NIOSH overall uncertainty recommendation(less than 25%). Overall uncertainty of Sepak-HPLC(UVD), Tube-GC(NPD), Tube-GC(FID) is 11.0% - 17.0%. Consequently gas chromatography(GC-NPD, GC-FID) and high performance liquid chromatography(EPA TO-11) using 2,4-DNPH coated sampler for formaldehyde measurement turned out to be suitable to measure personal formaldehyde exposure at workplaces.

  • PDF

Study on the Development of Analytical Method (Multi-Pesticide Residue Method) for Organophosphate Pesticides (유기인제 농약 분석 방법 (Multi-Pesticide Residue Method) 개발에 관한 연구)

  • 이봉헌;김우성
    • Journal of Environmental Science International
    • /
    • v.6 no.2
    • /
    • pp.183-187
    • /
    • 1997
  • Organophosphate pesticides were extracted with 70% acetone and then transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil. The florial extract was analyzed by gas chromatography with nitrogen-phosphorus detector(GC/NPD). Recoveries of the 18 organophosphate pesticides were ranged from 88.7% to 100. 0% for the narrow-bore capillary GC(Ultra-21. The minimum detectable level of this analytical method was 0.019 - 0.035 mg/kg. Sample throughput(extraction, open-column chro- matography, and GC analysts) was decreased considerably (8h per sample).

  • PDF

Analysis of Benzophenone in Sediment and Soil by Gas Chromatography/Mass Spectrometry (기체크로마토그래피/질량분석기에 의한 저질 및 토양시료 중 벤조페논의 분석법 연구)

  • 권오승;김은영;류재천
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.3
    • /
    • pp.121-126
    • /
    • 2001
  • Analytical method of benzophenone (BP) in sediment and soil was developed by gas chromatography/mass selective detector/selected ion monitoring (GC/MSD/SIM). The ultrasonic extraction of US EPA (method 3550B) method and liquid-liquid extraction for sediment and soil samples were used for the analysis of BP from sediment and soil. BP was extracted with n-hexane. Organic layer was washed with 5% sodium chloride solution. 1∼2 l of the concentrated solution of organic layer was applied to GC/MSD. The retention time of BP peak was 11.10 min. Recovery (%) of BP by ultrasonication from sediment and soil samples was 96.0∼100.6% and 40.0∼83.0%, respectively. Recovery of BP by liquid-liquid extraction was 51∼59% in soil samples. The detection limit of BP in sediment and soil samples were determined to 0.1 ng/g.

  • PDF

Multi-Pesticide Residue Method for Organopesticide Analysis (유기농약 분석을 위한 Multi-Pesticide Residue Method)

  • 김우성;이봉헌
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.385-389
    • /
    • 1997
  • Pesticide residues were extracted with 70% acetone and transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil and alumina-N. The final extract was analyzed by gas chromatography with electron-capture detector(GC /ECD) and nitrogen-phosphorus detector(GC/NPD). Recoveries of the 17 organochlorine pegticides were ranged from 60.8 to 84.9% and those of 15 organophosphate pesticides, from 70.5% to 100.0%(except phosmet and azlnphos-methyls. The minimum detectable levels of this analytical method were low(0.021-0.058mg/kg).

  • PDF

The Study on the Composition of Rehmanniae Radix Extracts by Supercritical Carbon Dioxide Extraction and by Hydrodistillation Extraction (생지황(生地黃) 증류 추출 약침액과 초임계 유체 추출물의 성분 연구(硏究))

  • Heo, Jong-Won;Yook, Tae-Han
    • Journal of Acupuncture Research
    • /
    • v.28 no.2
    • /
    • pp.89-95
    • /
    • 2011
  • Objectives : The purpose of this study was to investigate the composition of Rehmannia glutinosa's essential oils with Rehmanniae Radix herbal acupuncture Methods : I obtained the essential oils of Rehmannia Radix by hydrodistillation extraction method and supercritical fluid extraction(SFE) method, and then I analyzed those by GC/MS(gas chromatography/mass spectrum). Results : 1. With GC(gas chromatography) and GC/MS(gas chromatography/mass spectrum) analysis. I identified 9 compounds in the Rehmanniae Radix's essential oil obtained through the SFE method. The main compounds were as follows : Hexachloroethane(2.24%), N-Butyl-benzenesulfonamide(2.05%), hexadecanoic acid(1.93%), hexadecanoic acid, ethyl ester(3.49%), 9,12-Octadecadienoic acid(z,z)(2.70%), (9E)-9-Octadecenoic acid(6.14%), ethyl linoleate(4.43%), ethyl oleate(5.80%). 2. I failed to get Rehmanniae Radix's essential oil obtained through the hydrodistillation method. 3. With GC(gas chromatography) and GC/MS(gas chromatography/mass spectrum) analysis. I identified 4 compounds in the Rehmanniae Radix's essential oil obtained through the hydrodistillation method. The main compounds were as follows : Ethylbis(trimethylsilyl)amine(1.04%), 2-(Trimethylsiloxy)benzoic methyl ester(2.65%), Hexadecanoic acid trimethylsilyl ester(12.61%), octadecanoic acid, trimethylsilyl ester(6.28%). Conclusions : The substances by hydrodistillation method may not perfectly match with the substances by supercritical fluid extraction(SFE) method in essential oils extracted form Rehmanniae Radix. But, the main substances was assumed Hexadecanoic acid and octadecanoic acid.

Gas Chromatography-High Resolution Tandem Mass Spectrometry Using a GC-APPI-LIT Orbitrap for Complex Volatile Compounds Analysis

  • Lee, Young-Jin;Smith, Erica A.;Jun, Ji-Hyun
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.29-38
    • /
    • 2012
  • A new approach of volatile compounds analysis is proposed using a linear ion trap Orbitrap mass spectrometer coupled with gas chromatography through an atmospheric pressure photoionization interface. In the proposed GC-HRMS/MS approach, direct chemical composition analysis is made for the precursor ions in high resolution MS spectra and the structural identifications were made through the database search of high quality MS/MS spectra. Successful analysis of a complex perfume sample was demonstrated and compared with GC-EI-Q and GC-EI-TOF. The current approach is complementary to conventional GC-EI-MS analysis and can identify low abundance co-eluting compounds. Toluene co-sprayed as a dopant through API probe significantly enhanced ionization of certain compounds and reduced oxidation during the ionization.

Analysis of lipopolysaccharides of Pasteurella multocida and several Gram-negative bacteria by gas chromatography on a capillary column (Gas chromatography의 capillary column을 이용한 Pasteurella multocida 및 기타 그람음성 세균의 lipopolysaccharide 분석)

  • Ryu, Hyo-ik;Kim, Chul-joong
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.1
    • /
    • pp.72-80
    • /
    • 2000
  • Lipopolysaccharides (LPS) of Pasteurella multocida (P multocida) and several Gram-negative bacterial pathogens were analyzed by methanolysis, trifluoroacetylation and gas chromatography (GC) on a fused-silica capillary column. The GC analysis indicated that LPS prepared from a strain of P multocida by phenol-water (PW) or trichloroacetic acid (TCA) extraction were quite different in chemical composition. However, LPS prepared from Salmonella enteritidis by the two extraction methods were very similar. PW-LPS extracts from different Pasteurella strains of a serotype had essentially identical GC patterns. Endotoxic LPS extracted from 16 different serotypes of P multocida by PW or by phenol-chloroform-petroleum ether procedures yielded chromatograms indicating similar composition of the fatty acid moieties but minor differences in carbohydrate content. When the chemical composition of endotoxic LPS extracted from several Gram-negative bacteria (P multocida, Pasteurella hacmolytica, Haemophilus somnus, Actinobacillus ligniersii, Brucella abortus, Treponema hyodysenteriae, Escherichia coli, Bacteriodes fragilis, Salmonella abortus equi and Salmonella enteritidis) were examined, each bacteria showed a unique GC pattern. The carbohydrate constituents in LPS of various Gram-negative bacteria were quite variable not only in the O-specific polysaccharides but also in the core polysaccharides. The LPS of closely related bacteria shared more fatty acid constituents with each other than with unrelated bacteria.

  • PDF