• Title/Summary/Keyword: GB

Search Result 1,352, Processing Time 0.03 seconds

Investigating the Potential of Lipids for Use as Biomarkers for Glioblastoma via an Untargeted Lipidomics Approach

  • Burcak Soylemez;Zekeriya Bulut;Serap Sahin-Bolukbasi
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.2
    • /
    • pp.133-143
    • /
    • 2023
  • Objective : The types and functions of lipids involved in glioblastoma (GB) are not well known. Lipidomics is a new field that examines cellular lipids on a large scale and novel aplication of lipidomics in the biomedical sciences have emerged. This study aimed to investigate the potential of blood lipids for use as biomarkers for the diagnosis of GB via untargated lipidomic approach. Gaining a deeper understanding of lipid metabolism in patients with GB can contribute to the early diagnosis with GB patiens and also development of novel and better therapeutic options. Methods : This study was performed using blood samples collected from 14 patients (eight females and six males) and 14 controls (eight females and six males). Lipids were extracted from blood samples and quantified using phosphorus assay. Lipid profiles of between patients with GB and controls were compared via an untargeted lipidomics approach using 6530 Accurate-Mass Q-TOF LC/MS mass spectrometer. Results : According to the results obtained using the untargeted lipidomics approach, differentially regulated lipid species, including fatty acid (FA), glycerolipid (GL), glycerophospholipid (PG), saccharolipid (SL), sphingolipid (SP), and sterol lipid (ST) were identified between in patients with GB and controls. Conclusion : Differentially regulated lipids were identified in patients with GB, and these lipid species were predicted as potential biomarkers for diagnosis of GB.

Hepatoprotective effect of electroacupuncture at GB34 (Yangreungcheon) in $CCl_4$-intoxicated rats (양릉천 저주파 전침자극이 $CCl_4$로 유발된 흰쥐의 간 손상에 미치는 영향)

  • Chae, Choong-Heon;An, Taek-Won;Yim, Yun-Kyung
    • Korean Journal of Acupuncture
    • /
    • v.25 no.2
    • /
    • pp.211-224
    • /
    • 2008
  • Objectives : To investigate the effect of electro-acupuncture (EA) at GB34 on hepatotoxicity in $CCl_4$-intoxicated rats. Methods : Rats were injected with $CCl_4$ and treated with acupuncture or 2 Hz electro-acupuncture (EA) at left GB34 three times a week for 10 weeks. A non-acupoint in left gluteal area was selected as a sham point. To estimate the effects of EA on hepatotoxicity in rats, body weight, liver weight and liver index were measured, and biochemical assays for serum ALT, AST, ALP and total cholesterol, and hematological analysis for RBC, WBC, PLT, hemoglobin, lymphocytes, neutrophils and monocytes, and histology analysis of liver tissue were performed. Results : 1. Lymphocyte level in blood was significantly decreased by $CCl_4$-intoxication and significantly increased by acupuncture and 2 Hz EA at left GB34. 2. Neutrophill and monocyte level in blood was increased by $CCl_4$-intoxication and significantly reduced by acupuncture and 2 Hz EA at left GB34. 3. Acupuncture and 2 Hz EA at left GB34 significantly reduced serum ALT and AST which were increased by $CCl_4$-intoxication. 4. EA at GB34 significantly reduced serum ALT and AST as compared with EA at sham point in $CCl_4$-intoxicated rat. 5. No significant difference was found between the effects of acupuncture and that of 2 Hz EA on $CCl_4$-induced liver damage in rats. Conclusions : 2 Hz EA at GB34 has hepatoprotective effects on $CCl_4$-induced liver damage in rats and the point-specificity of GB34 may be involved in these effects.

  • PDF

A 1.88-mW/Gb/s 5-Gb/s Transmitter with Digital Impedance Calibration and Equalizer (디지털 임피던스 보정과 이퀄라이저를 가진 1.88mW/Gb/s 5Gb/s 송신단)

  • Kim, Ho-Seong;Beak, Seung-Wuk;Jang, Young-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.110-116
    • /
    • 2016
  • This paper describes 1.2-V 5-Gb/s scalable low voltage signaling(SLVS) differential transmitter(TX) with a digital impedance calibration and equalizer. The proposed transmitter consists of a phase-locked loop(PLL) with 4-phase output clock, a 4-to-1 serializer, a regulator, an output driver, and an equalizer driver for improvement of the signal integrity. A pseudo random bit sequence generator is implemented for a built-in self-test. The proposed SLVS transmitter provides the output differential swing level from 80mV to 500mV. The proposed SLVS transmitter is implemented by using a 65-nm CMOS with a 1.2-V supply. The measured peak-to-peak time jitter of the implemented SLVS TX is about 46.67 ps at the data rate of 5Gb/s. Its power consumption is 1.88 mW/Gb/s.

Vasodilation Effect of the Water Extract of Gingko biloba, Acanthopanax senticosus and Augmented Four-Substance Decoctions in Rat Thoracic Aorta (백과엽(白果葉) 및 자오가(刺五加) 가미사물탕(加味四物湯)이 백서(白鼠)의 흉부대동맥(胸部大動脈) 혈관이완(血管弛緩)에 미치는 영향)

  • Kim Hyung-Hwan;Park Soo-Yeon;Kang Soon-Ah;Kim Hong-Yeoul;Ahn Duk-Kyun;Park Seong-Kyu
    • Herbal Formula Science
    • /
    • v.11 no.2
    • /
    • pp.125-134
    • /
    • 2003
  • We have examined the relaxational response to the water extract of Angelica gigas $N_{AKAI}$ (AG), Gingko biloba $L_{INNE}$ (GB), Acanthopanax senticosus $H_{ARMS}.$ (AP) and Augumented-Four-Substance Decoction (AG-FSD, GB-FSD, AP-FSD) in isolated thoracic aorta from sprague dawley(SD) rat. Rat thoracic aorta was investigated in vessel segments suspended for isometric tension recording by polygraph. Responses to AG, GB, AP and AG-FSD, GB-FSD, AP-FSD were investigated in vessels precontracted with 5-hydroxytryptamine(5-HT) were compared in vasodilation effect. We found that the thoracic aorta segments responded to AG, GB, AP and AG-FSD, GB-FSD, AP-FSD with a dose-dependent vasodilation. The 5-hydroxytryptamine induced contraction at $10^{-4}M$ were inhibited by 26.3%, 75.8%, 87.5% and 6.9%, 22.6%, 30.8% after addition of the 0.1 g/mL water extract of AG, GB, AP and AG-FSD, GB-FSD, AP-FSD. In conclusion, AG, GB, AP and AG-FSD, GB-FSD, AP-FSD induced relaxation in the isolated rat thoracic aorta were composed of dose-dependent relaxation. AP-FSD has very potent vasodilation.

  • PDF

A 2.5Gb/s 2:1 Multiplexer Design Using Inductive Peaking in $0.18{\mu}m$ CMOS Technology (Micro spiral inductor를 이용한 2.5Gb/s급 2:1 Multiplexer 설계)

  • Kim, Sun-Jung;Choi, Jung-Myung;Burm, Jin-Wook
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.22-29
    • /
    • 2007
  • A 2.5Gb/s 2:1 multiplexer(MUX) IC using $0.18{\mu}m$ CMOS was designed and fabricated. Inductive peaking technology was used to improve the performance. On-chip micro spiral inductor was designed to maximize the inductive peaking effect without increasing the chip area much. The designed 4.7 nH micro-spiral inductor was $20\times20{\mu}m2$ in size. 2:1 MUX with and without micro spiral inductors were compared. The rise and fall time was improved more than 23% and 3% respectively using the micro spiral inductors for 1.25Gb/s signal. For 2.5 Gb/s signal, fall and rise time was improved 5.3% and 3.5% respectively. It consumed 61mW and voltage output swing was 1$180mV_{p-p}$ at 2.5Gb/s.

All Flash Array Storage Virtualisation using SCST (SCST를 이용한 All Flash Array 스토리지 가상화)

  • Heo, Huiseong;Pirahandeh, Mehdi;Lee, Kwangsoo;Kim, Deokhwan
    • KIISE Transactions on Computing Practices
    • /
    • v.20 no.10
    • /
    • pp.525-533
    • /
    • 2014
  • SCST(The generic SCSI target subsystem for Linux) enables developers to make SCSI target storage and supports various SCSI network protocol such as iSCSI, FC, SRP. In this paper, we propose storage virtualization method using SCST and virtualize all flash array as high performance storage through 4Gb Fiber Channel, 10Gb Ethernet and 40Gb Infiniband and evaluate their performance, respectively. Experimental result shows that 40Gb infiniband network appliance have better performance than others. In case of sequential/random read, 40Gb infiniband network appliance shows 78% and 79% of local all flash array performance attached to SCSI target system. In case of sequential/random write, it shows 83% and 88% of local flash array performance attached to SCSI target system.

Comparison Study for Analgesic Effects of Electroacupuncture on Surgical Ankle Sprain Model Classified as Grade 3 in Rats (수술적 방법으로 유도된 3단계 고도(高度) 발목염좌 모델에서 혈위(穴位)에 따른 전침효과의 비교)

  • Yang, Seung-Bum;Sohn, In-Chul;Lee, Sung-Ho;Cho, Sang-Hoon;Kim, Jaehyo
    • Korean Journal of Acupuncture
    • /
    • v.30 no.1
    • /
    • pp.47-55
    • /
    • 2013
  • Objectives : The purpose of this study was to determine whether electroacupuncture(EA) is effective in reducing pain on the severe ankle sprain classified as grade 3 in rats. Methods : The severe(grade 3) ankle sprain model was induced surgically by ankle ligament injury(the anterior talofibular, the calcaneofibular and the posterior talofibular) in the Sprague-Dawley rats(180~250 g). The effects of EA on weight bearing forces(WBR) of the affected foot were examined in a rat model of ankle sprain. EA was applied to either SI6, ST37, GB34, GB39 or GB42 acupoints by trains of electrical pulses(2 Hz, 1 ms pulse width, 2 mA intensity) for 15 min. Results : Cutting of the lateral ankle ligament complex produced the severe ankle sprain symptoms as grade 3. EA of the contralateral SI6 resulted in more analgesic effect than one of ipsilateral SI6 even though there was significant effect. EA of the ipsilateral GB34 and GB39 produced potent analgesic effects on the surgical ankle sprained pain behaviors. However, there were no significant analgesic effects in the contralateral GB34 and GB39 EA groups. In addition, both side of ST37 and GB42 did not result in analgesic effect on the surgical ankle sprained rat. Conclusions : The data suggest that EA induced analgesia shows point specificity on the severe ankle sprained pain model classified as grade 3.

Analgesia of Electroacupuncture and Radio-Frequency Warm Needling in Acupoint Combination on Ankle Sprain in Rats (발목염좌에 배혈에 따른 전침과 고주파온침의 진통효과)

  • Yang, Seung-Bum;Kim, Min-Su;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.35 no.1
    • /
    • pp.27-35
    • /
    • 2018
  • Objectives : The purpose of this study was to investigate the analgesic effect of electroacupuncture(EA) and radio-frequency warm needling(RFWN) stimulation in acupoint combination on ankle sprained pain in rats. Methods : The lateral ligaments of the Sprague-Dawley rats ankle were injured surgically resulting in sprain, of which was divided into EA, RFWN treatment groups and control group without treatment. The level of pain was measured through foot weight bearing force ratio followed by calculating pain relief. To stimulate proximal or distal area in ankle sprain, combination of proximal acupoints(GB34-GB39) and distal acupoints(GB39-GB42) from sprain area were applied, respectively, to either EA or RFWN stimulation. In addition, naltrexone or phentolamine was injected intraperitoneally before the stimulation to observe the pathway of analgesic effects. Results : In the proximal combination of GB34-GB39, EA and RFWN significantly increased pain relief compared to the control group (p<0.05). However, in distal combination with GB39-GB42, both EA and RFWN stimulation did not relieve pain due to ankle sprains. In the combination of GB34-GB39, the analgesia of EA was inhibited by blockade of the ${\alpha}$-adrenoceptor receptor. The analgesia of RFWN was inhibited by blockade of the ${\alpha}$-adrenoceptor receptor as well as ${\mu}$-opioid receptor. Conclusions : We observed that the proximal combination was effective in relieving pain when the treatment by acupoint combination was applied to the ankle sprain pain. Also, it was confirmed that this analgesia was also related to the pathways of ${\mu}$-opioid receptors and/or ${\alpha}$-adrenoceptors.

Effects of Laser Acupuncture Therapy According to the Wavelength at GB34·GB39 on Neuropathic Pain Rat Induced by Tibial and Sural Nerve Transection (양릉천(GB34)·현종(GB39)에 대한 파장대별 레이저침 시술이 동통에 미치는 영향)

  • Youn, Daehwan;Yoo, Pyungsik;Kim, Wangin;Kim, Mirea;Choi, Donghee;Na, Changsu
    • Korean Journal of Acupuncture
    • /
    • v.31 no.4
    • /
    • pp.195-207
    • /
    • 2014
  • Objectives : The purpose of this study is to examine the effects of laser acupuncture according to the wavelength(532 nm, 650 nm, 830 nm, 904 nm, and 1064 nm) at the acupoint of GB34 GB39 on neuropathic pain rat induced by tibial and sural nerve transection(TST). Methods : Neuropathic pain in rats was induced by tibial nerve and sural nerve transection. The rats were divided into the intact group, the TST control group, and the laser acupuncture therapy group. The laser acupuncture therapy groups were then divided into subgroups with 532 nm(L532), 650 nm(L650), 830 nm(L830), 904 nm(L904), and 1064 nm(L1064) laser acupuncture therapy. The acupoint of GB34 GB39 was selected, and laser acupuncture therapy was provided on both sides alternatively twice a week in a total of 6 sessions. Results : All the laser acupuncture groups showed a significant decrease in reaction time and force intensity. L532, L904, and L1064 groups showed a significant decrease in Bax, the L532 group showed a significant increase in Bcl-2, L532 and L1064 groups showed a significant decrease in the Bax/Bcl-2 ratio, and L532 and L650 groups showed a significant increase in mGluR5, as compared with the TST control group, among nerve tissue reaction. Conclusions : These results showed that laser acupuncture therapy at each of the wavelengths had some significance on neuropathic pain.

A Philological Study on the Acupuncture treatment of Sciatica (좌골신경통(坐骨神經痛)의 침구치료(鍼灸治療)에 관(關)한 문헌적(文獻的) 고찰(考察))

  • Moon, Ja-Young;Lee, Jun-Hee;Park, Chul-Jin
    • Korean Journal of Acupuncture
    • /
    • v.26 no.2
    • /
    • pp.177-195
    • /
    • 2009
  • Objectives : This study is performed to investigate the acupuncture on Sciatica through the literature of oriental medicine. Methods : We collected the oriental medical literature from ancient to modern times, and extracted the causes, symptoms, treatments and acupoints of sciatica. Results : The findings of this study are as follows: 1. The etiology of Sciatica is differentiated into the exogenous pathogenic factors(wind, cold, dampness, trauma, bad posture) and the internal pathogenic factors(deficiency of the kidney energy, congenital debility). 2. The symptoms of Sciatica are pain, weakness and dysesthesia in the low back, hip and lower limb. 3. In the treatment of Sciatica, The Leg Greater Yang Bladder (BL) Meridian and The Leg Lesser Yang Gall Bladder (GB) Meridian out of 12 meridians were mainly used and the acupoint GB30(Hwando) was most frequently used in the acupuncture literature. 4. The number of acupoints used for sciatica was 95, and those acupoints in the order of frequency were GB30(Hwando), GB34(Yangnungch'on), BL40(Wijung), BL60(Kollyun), GB31(P'ungshi), GB39(Hyonjong), BL57(Sungsan), ST36(Chok-samni). Conclusion : The most frequently used acupoints for the treatment of sciatica are as follows; GB30(Hwando), GB34(Yangnungch'on), GB31(P'ungshi), GB39(Hyonjong) of The Leg Lesser Yang Gall Bladder Meridian, BL40(Wijung), BL60(Kollyun), BL57(Sungsan) of The Leg Greater Yang Bladder Meridian.

  • PDF